• 제목/요약/키워드: Solar radiation shield

검색결과 10건 처리시간 0.031초

메쉬 스크린을 적용한 해양구조물용 방풍 및 복사열 차단막 열유동특성에 관한 연구 (A Study on the Thermal and Flow Characteristics of Wind and Radiant Heat Shield for Offshore by using Mesh Screen)

  • 이중섭;진도훈
    • 한국기계가공학회지
    • /
    • 제11권3호
    • /
    • pp.166-173
    • /
    • 2012
  • This study is about comparison of thermal and flow characteristics on the wind & radiant heat shield with STS mesh type screen for offshore. Numerical analysis was conducted to find transmission coefficient in the mesh and then analyse the flow characteristics about wind & radiant heat shield. The experiment method of solar radiation has been used as thermal radiation source to get the performance of radiant heat shield measurement. The sensor radiation device has been used to measure the reduction of solar radiation with various size of cells and at a distance of 0.5m and 1m from the cold face of the wind & radiant heat shield.

Effects of Fan-Aspirated Radiation Shield for Temperature Measurement in Greenhouse Environment

  • Yang, Seung-Hwan;Lee, Chun-Gu;Kim, Joon-Yong;Lee, Won-Kyu;Ashtinai-Araghi, A.;Rhee, Joong-Yong
    • Journal of Biosystems Engineering
    • /
    • 제37권4호
    • /
    • pp.245-251
    • /
    • 2012
  • Purpose: Provision of accurate temperature measurement is an essential element to ensure a precise control in greenhouse environment. This study was organized to compare the effects of six solar radiation shields with different shapes for temperature measurement and find the most appropriate shield for greenhouse environment. Methods: A fan-aspirated radiation shield was designed and manufactured. Using the fan-aspirated radiation shield and five other shapes i.e., the cup shape, horizontal pipe, vertical pipe, parallel boards and commercial shields, temperature measurement was conducted over the lawn surface as well as greenhouse indoor environment. The measurement height varied at 0.5, 1.0 and 1.5 m from the floor. Results: The measured temperatures by the fan-aspirated radiation shield were 1.30-$1.49^{\circ}C$ lower than the values recorded by other different-shaped shields at 1.5 m of measurement height. As the measurement height decreases, observed differences between measured temperatures of the fan-aspirated radiation shield and other shields demonstrate a declining trend. However, at low measurement heights, the radiation emitted from the bottom surface would be the source of error in temperature measurement. Conclusions: The fan-aspirated radiation shield is a required tool for exact measurement of air temperature in greenhouse temperature control.

SYSTEM TRADE-OFF STUDY AND OPTO-THERMO-MECHANICAL ANALYSIS OF A SUNSHIELD ON THE MSC OF THE KOMPSAT-2

  • Kim, Young-Soo;Lee, Eung-Shik;Woo, Sun-Hee
    • Journal of Astronomy and Space Sciences
    • /
    • 제20권4호
    • /
    • pp.393-402
    • /
    • 2003
  • The Multi-Spectral Camera (MSC) is the payload of KOMPSAT-2 which is designed for earth imaging in optical and near-infrared region on a sun-synchronous orbit. The telescope in the MSC is a Ritchey-Chretien type with large aperture. The telescope structure should be well stabilized and the optical alignment should be kept steady so that best images can be achieved. However, the MSC is exposed to adverse thermal environment on the orbit which can give impacts on optical performance. Solar incidence can bring non-uniform temperature rise on the telescope tube which entails unfavorable thermal distortion. Three ways of preventing the solar radiation were proposed, which were installing external mechanical shield, internal shield, and maneuvering the spacecraft. After trade-off study, internal sun shield was selected as a practical and optimal solution to minimize the effect of the solar radiation. In addition, detailed designs of the structure and sunshield were produced and analyses have been performed. The results were assessed to verify their impacts to the image quality. It was confirmed that the internal sunshield complies with the requirements and would improve image quality.

System Design of Sunshield on the MSC

  • Kim, Young-Soo;Lee, Eung-Shik;Woo, Sun-Hee
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.815-820
    • /
    • 2002
  • MSC as a payload of KOMPSAT-2 is an optical telescope for earth imaging on a sun-synchronous orbit. The MSC is a Ritchey-Chretien type telescope composed of hyperbolic primary and secondary mirrors with focal correcting lenses. Their relative positions should be kept aligned during imaging operation. However, the MSC is exposed to adverse thermal environment on orbit which can have some impacts on optical performance as well as structural endurance. Solar incidence can cause non-uniform temperature rise on the tube which entails unfavorable thermal distortion. Three options were proposed, which were internal shield, external mechanical shield and spacecraft maneuvering. After the trade-off studies, internal sun shield was selected as a realistic and optimal solution to minimize the effect of the solar radiation. In this paper, pros and cons are explained for the three possible choices and a design of the internal shield is discussed.

  • PDF

수치표고모델, 3차원 카메라이미지자료 및 복사모델을 이용한 Sky Line과 Skyview Factor에 따른 강릉원주대학교 복사관측소 관측환경 분석 (Analysis of Observation Environment with Sky Line and Skyview Factor using Digital Elevation Model (DEM), 3-Dimensional Camera Image and Radiative Transfer Model at Radiation Site, Gangneung-Wonju National University)

  • 지준범;조일성;김부요;이규태;장정필
    • 대기
    • /
    • 제29권1호
    • /
    • pp.61-74
    • /
    • 2019
  • To investigate the observational environment, sky line and skyview factor (SVF) are calculated using a digital elevation model (DEM; 10 m spatial resolution) and 3 dimensional (3D) sky image at radiation site, Gangneung-Wonju National University (GWNU). Solar radiation is calculated using GWNU solar radiation model with and without the sky line and the SVF retrieved from the 3D sky image and DEM. When compared with the maximum sky line elevation from Skyview, the result from 3D camera is higher by $3^{\circ}$ and that from DEM is lower by $7^{\circ}$. The SVF calculated from 3D camera, DEM and Skyview is 0.991, 0.998, and 0.993, respectively. When the solar path is analyzed using astronomical solar map with time, the sky line by 3D camera shield the direct solar radiation up to $14^{\circ}$ with solar altitude at winter solstice. The solar radiation is calculated with minutely, and monthly and annual accumulated using the GWNU model. During the summer and winter solstice, the GWNU radiation site is shielded from direct solar radiation by the west mountain 40 and 60 minutes before sunset, respectively. The monthly difference between plane and real surface is up to $29.18M\;m^{-2}$ with 3D camera in November, while that with DEM is $4.87M\;m^{-2}$ in January. The difference in the annual accumulated solar radiation is $208.50M\;m^{-2}$ (2.65%) and $47.96M\;m^{-2}$ (0.63%) with direct solar radiation and $30.93M\;m^{-2}$ (0.58%) and $3.84M\;m^{-2}$ (0.07%) with global solar radiation, respectively.

시험용 달 궤도선의 광학탑재체 시스템 열설계에 대한 수치해석적 연구 (Numerical Study on the Thermal Design of Lunar Terrain Imager System Loaded on the Korea Pathfinder Lunar Orbiter)

  • 김택영;장수영;허행팔
    • 한국항공우주학회지
    • /
    • 제47권4호
    • /
    • pp.309-318
    • /
    • 2019
  • 한국형 달 궤도선(Korea Pathfinder Lunar Orbiter, KPLO)에 탑재되는 달 표면지형 광학관측기(Lunar Terrian Imager, LUTI)의 열설계를 수행하고, 열해석을 통하여 열설계의 건전성을 검증하였다. 달 임무궤도의 열환경은 지구궤도와 달리 달 표면의 IR 복사가 중요하므로 이를 열설계에 반영하여야 한다. 위성 외부에 노출되는 부품이나 모듈은 가능한 MLI로 단열시키지만 경통이나 방열판은 기능상 노출되므로 복사형상계수의 개념을 이용한 thermal shield를 전면에 장착함으로써 IR 복사를 완화시킨다. 태양복사를 거의 받지 않는 방열판의 전면부는 IR 방사율이 중요하며, 경통과 같이 열변형에 취약한 부품은 복사히터를 사용하여 온도구배를 최소화시킨다. 열해석 결과분석을 통하여 LUTI의 열설계는 다양한 상황에서 안정적임을 확인하였다.

딸기재배 온실용 온습도 계측시스템의 성능개선 (Performance Improvement of a Temperature and Humidity Measuring System for Strawberry Cultivation Greenhouse)

  • 정영균;이종구;안은기;서재석;윤용철
    • 생물환경조절학회지
    • /
    • 제29권2호
    • /
    • pp.110-119
    • /
    • 2020
  • 본 연구는 기존에 사용하여 왔고, 최근에 온습도의 정확도를 검증하였던 강제 흡출식 복사선 차폐장치(Aspirated Radiation Shield; ARS)를이용하여 모 기업(A 회사)에서 개발한 시스템의 성능을 개선하고, ARS 장치의 풍속이 온습도에 미치는 영향에 대해서도 시험적으로 검토하였다. 그 결과를 요약하면 다음과 같다. A 회사 제품의 시스템을 개선하기 전, A 회사 시스템의 온도는 ARS 장치로 측정한 온도보다 최대 10.2℃정도 높았고, 상대습도는 20.0%정도 낮게 나타났다. 시스템을 개선한 후, 노드 1, 2의 온도 및 상대습도는 거의 일치하는 것으로 나타났다. 개선 후의 노드 2와 ARS 장치로 측정한 온도간의 최고, 평균 및 최저온도를 포함한 온도편차는 각각 0.2~0.7℃정도로써 ARS 장치가 약간 낮거나 높게 나타나는 경향이 있었다. 상대습도의 경우, 일몰 직후 ARS 장치의 상대습도가 약 10.0%정도 높게 나타나는 경향이 있었지만, 그 이외에는 평균적으로 1.9%정도 ARS 장치가 약간 낮게 나타나는 경향이 있었다. 그리고 노드 1을 최소-중간 사이, 중간-최대 사이 및 최대로 설정한 경우, 노드 1, 2의 최고, 평균 및 최저온도를 포함한 편차는 각각 0.1~0.4℃, 0.0~0.2℃ 및 0.0~0.5℃정도였다. 그리고 노드 1의 3개 측점과 ARS 장치의 최고, 평균 및 최저온도를 포함한 편차는 각각 0.2~0.5℃, 0.1~2.2℃ 및 0.1~1.1℃정도의 범위로써 풍속의 크기에 따른 온도편차는 아주 미미한 것으로 나타났다. 또한 선행연구 및 본 연구의 결과를 종합하여 보면, 온도오차를 개선하기 위한 적정 풍속은 1.0~2.0m·s-1 정도의 범위일 것으로 판단되었다.

딸기재배 스마트 온실용 온습도 계측시스템의 성능평가 (Analyzing the Performance of a Temperature and Humidity Measuring System of a Smart Greenhouse for Strawberry Cultivation)

  • 정영균;이종구;안은기;서재석;김현태;윤용철
    • 생물환경조절학회지
    • /
    • 제28권2호
    • /
    • pp.117-125
    • /
    • 2019
  • 본 연구는 기존에 사용하여 왔고, 최근에 온습도의 정확도를 검증하였던 강제 흡출식 복사선 차폐장치(Aspirated Radiation Shield; ARS)와 모 기업(A 회사)에서 개발한 시스템으로 측정한 온습도를 비교하여 성능을 검토한 후, 시스템의 성능을 개선할 목적으로 수행되었다. 그 결과를 요약하면 다음과 같다. 딸기의 무성도가 두 계측시스템에 영향을 미친 경우를 제외하면, 전체적으로 볼 때 플레이트 2개의 시스템이 1개보다 복사선 차폐효과가 미미하지만 좋은 것으로 나타났다. 그리고 A회사의 시스템과 ARS장치로 측정한 최고온도의 전체적인 범위는 각각 $20.5{\sim}53.3^{\circ}C$$17.8{\sim}44.1^{\circ}C$정도로써 A사 제품이 $2.7{\sim}9.2^{\circ}C$정도 높게 나타났고, 일별 최대 편차는 $12.2^{\circ}C$ 정도였다. 평균온도의 경우, 두 기관의 전체적인 범위는 각각 $12.4{\sim}38.6^{\circ}C$$11.8{\sim}32.7^{\circ}C$정도로써 A사 시스템이 $0.6{\sim}5.9^{\circ}C$정도 높게 나타났고, 일별 최대 편차는 $6.7^{\circ}C$정도였다. 최저온도의 경우도 각각 $4.2{\sim}28.6^{\circ}C$$2.9{\sim}26.4^{\circ}C$정도로써 A사 제품이 $1.3{\sim}2.2^{\circ}C$정도 높게 나타났고, 일별 최대 편차는 $2.9^{\circ}C$정도로써 두 기관의 장치로 측정한 온도에 편차가 있는 것으로 나타났다. 또한 상대습도의 경우, A회사와 ARS장치로 측정한 평균상대습도의 전체적인 범위는 각각 52.9~93.3% 및 55.3~96.5%정도로써 A회사의 시스템이 ARS장치보다 2.4~3.2%정도 낮게 나타나는 경향을 보였다. 그러나 일별로 비교하여 보면, 최대 18.0%정도 A회사의 시스템이 낮게 나타나는 날도 있었다. 결국 상대습도도 온도와 마찬가지로 미미하긴 하지만 두 기관의 장치로 측정한 온도에 편차가 있는 것으로 나타났다.

5 L급 액체수소 저장용기의 성능특성 연구 (Performance of a 5 L Liquid Hydrogen Storage Vessel)

  • 강상우;나다니엘 가르소;임창무;백종훈;김서영;오인환
    • 한국수소및신에너지학회논문집
    • /
    • 제26권3호
    • /
    • pp.234-240
    • /
    • 2015
  • In the face of the world's growing energy storage needs, liquid hydrogen offers a high energy density solution for the storage and transport of energy throughout society. A 5 L liquid hydrogen storage tank has been designed, fabricated and tested to investigate boil-off rate of liquid hydrogen. As the insulation plays a key role on the cryogenic vessels, various insulation methods have been employed. To reduce heat conduction loss, the epoxy resin-based insulation supports G-10 were used. To minimize radiation heat loss, vapor cooled radiation shield, multi-layer insulation, and high vacuum were adopted. Mass flow meter was used to measure boil-off rate of the 5 L cryogenic vessel. A series of performance tests were done for liquid nitrogen and liquid hydrogen to compare with design parameters, resulting in the boil-off rate of 1.7%/day for liquid nitrogen and 16.8%/day for liquid hydrogen at maximum.

고온기 멜론 시설재배 시 자재별 차광 효과 (Effects of Shield Materials on the Growth and Yield Characteristics of Melon Grown inside a Plastic Greenhouse in Summer Season)

  • 이재한;이중섭;권준국;여경환;방지웅;김진현;이충근;박경섭;명동주
    • 생물환경조절학회지
    • /
    • 제30권4호
    • /
    • pp.304-311
    • /
    • 2021
  • 고온기 시설멜론 재배 시 저비용 고효율의 개발하기 위하여 차광 자재별 이용 효과를 구명하고자 수행하였다. 차광처리에 따른평균온도는 무차광이 36.6℃, 차광도포제는 34.5℃, 백색차광망은 34℃로 조사되었다. 도포제 살포 직후에 투광률이 무차광에 비해서 차광 도포제 처리구는 69%, 백색차광망 처리구는 75% 이었으나, 40일 및 80일 후 차광 도포제 처리구의 투광률이 각각 92% 및 98%로 높아져 처리된 차광도포제가 서서히 제거되는 것을 알 수 있었으며, 백색차광망 처리구는 시간의 경과에 따른 투광률의 변화가 거의 없었다. 생육에 있어 엽수는 처리 간에 차이가 없었고, 초장은 무차광에 비해 백색차광망과 차광도포제 처리구에서 높게 나타났다. 엽중, 생체중, 건물중의 경우 차광 처리구에 비해서 무차광에서 정식 42일 후에는 더 무거운 것으로 나타났다. 총 상품수량은 무차광에 비해서 백색차광망과 차광도포제가 각각 6% 및 5% 증수되었다. 따라서 고온기 간편하게 온도를 낮출수 있는 방법으로 차광도포제는 효과적이나 서서히 제거되기 때문에 재배 시기를 고려해서 사용하는 것이 바람직하다고 생각되었다.