• Title/Summary/Keyword: Solar radiation rate

Search Result 200, Processing Time 0.031 seconds

A Study of Bleaching Phenomenon of Otter (Lutra lutra) Spraints in Relation to Weather Conditions and Characteristics of Sprainting Sites (기상조건과 배설지 특성에 따른 수달(Lutra lutra) 분변의 표백현상에 관한 연구)

  • Noh, Eun-Young;Han, Sung-Yong;Yoo, Jeong-Chil
    • Journal of Wetlands Research
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 2015
  • The bleaching phenomenon of otter spraints is indicates that the age of spraints (fresh or old spraints). As previous studies on the old otter faeces (spraint) have focused only on the external changes of spraints, it has been difficult to explain the difference of the decomposition rates among old spraints. We hypothesized that the micrometeorology difference caused by various characteristics of sprainting sites such as porosity and consistency of soil could affect the extent of the decomposition rate, the solar bleaching phenomenon of spraints used as a measure of the patterns of old spraints. Sprainting sites were classified into four types (Clay, Sand, Rock and Concrete spot) and each type was divided into two groups according to the sunlight condition (Sunny site and Shady site) to measure the effect of solar radiation. Micrometeorology of the sites were evaluated by measuring temperatures and humidities of the sites during the whole season. The variations in micrometeorology of the sunny sites according to the sprainting site types were examined with correlation analyses between the factors of micrometeorology. The analyses on the bleaching phenomenon of the spraints by micrometeorology showed that the highest rate of bleaching was found at the 'Rock spot' and 'Concrete spot' of the sunny site and especially in summer, the highest rate of bleaching ($63.4{\pm}7.6%$) was found at the 'Clay spot' of the sunny sites. The lowest rate of bleaching was found at the 'Sand spot' of the sunny sites. The above findings show that the difference in bleaching rates among sprainting sites was due to the seasonal or sunny condition. In addition, we found that the differences in thermal conductivity among sprainting site characteristics have resulted in different sprainting site temperature which have affected the rate of bleaching of spraints. In conclusion, this study suggests that studies of otters on their population size and home ranges using spraints as an indirect sign, should consider the effects of sprainting site characteristics and weather conditions.

The Influence of the Landscaping Shade Membrane's Brightness on the Mean Radiant Temperature(MRT) of Summer Outdoor (조경용 차양막 재료의 명도가 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.5
    • /
    • pp.65-73
    • /
    • 2015
  • The purpose of this study was to compare the Mean Radiant Temperature(MRT) under two landscaping shade membranes, white and black, with those of natural outdoor spaces at summer midday. An additional perforated black shading net was applied and compared for the consideration of the practical application. The average MRT at the height of 2.4m, 10cm below the membranes of black, white, and perforated black were $49.1^{\circ}C$, $41.6^{\circ}C$ and $36.8^{\circ}C$ respectively, while that of open sky was $41.8^{\circ}C$. This indicates that a closer position to the darker membrane caused a higher MRT. At the height of 1.1m and 1.7m, the difference of MRT between the black and the white membranes was slight, while the value of white was unexpectedly higher than the black. The MRT of black perforated net showed the lowest value at every height. The black membrane absorbed more solar radiation than the white, which caused the greater release of long wave radiation and higher temperature near the membrane itself. In spite of the higher albedo of the white membrane, the higher solar radiation transmittance rate of which seemed to cause the slightly higher MRT than the black at the hight of 1.1m and 1.7m. In summary, the performance of the black membrane was slightly better than the white in terms of the air conditioning of the human related space around the height of 1.1m and 1.7m, when the shading membranes were at 2.5m height.

A Three-dimensional Numerical Weather Model using Power Output Predict of Distributed Power Source (3차원 기상 수치 모델을 이용한 분산형 전원의 출력 예)

  • Jeong, Yoon-Su;Kim, Yong-Tae;Park, Gil-Cheol
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.4
    • /
    • pp.93-98
    • /
    • 2016
  • Recently, the project related to the smart grid are being actively studied around the developed world. In particular, the long-term stabilization measures distributed power supply problem has been highlighted. In this paper, we propose a three-dimensional numerical weather prediction models to compare the error rate information which combined with the physical models and statistical models to predict the output of distributed power. Proposed model can predict the system for a stable power grid-can improve the prediction information of the distributed power. In performance evaluation, proposed model was a generation forecasting accuracy improved by 4.6%, temperature compensated prediction accuracy was improved by 3.5%. Finally, the solar radiation correction accuracy is improved by 1.1%.

A Comparative Study on the Windchill Indices (체감온도이론의 비교 연구)

  • Park, Jeon-Hwan;Han, Uk;Park, Rae-Seol
    • Journal of the Korean earth science society
    • /
    • v.23 no.8
    • /
    • pp.676-682
    • /
    • 2002
  • The concept of sensible temperature in winter is an attempt to quantify the sensation of cold by dry-bulb temperature combined with wind speed. Siple-Passel’s windchill equivalent temperature originated in experiments that are not conformable to various human conditions. Therefore, many investigators have found the flaws which are listed. Steadman’s model is based on the concept of thermal equilibrium and more sound and more representative of human conditions. But no classifications exist for Steadman’s windchill equivalent temperature, yet. The JAG/TI-model which was developed by US and Canada is more accurate, easy to understand and reflects human beings by conducting experiments using human volunteers but didn't take into account solar radiation, wet condition and physical state of the individual. Because of individual differences in people’s age, activity, health, metabolic rate, etc., no experimental evidence exists to suggest whether Siple-Passel’s, Steadman’s and JAG/TI-model’s windchill equivalent temperature is more applicable to the majority of people. Therefore we need the windchill model which is best applicable to Korean Army.

A Numerical Analysis on Transient Fuel temperatures in a Military Aircraft under Non-operating Ground Static Condition (지상 정적 상태에서의 항공기내 연료온도변화에 대한 수치해석)

  • 김영준;김창녕
    • Journal of Energy Engineering
    • /
    • v.12 no.1
    • /
    • pp.11-16
    • /
    • 2003
  • A numerical study was performed on the transient fuel temperatures of a military aircraft stationed under non-operating static condition. Numerical calculation was peformed by an explicit method using modified Dufort-Frankel scheme. It was assumed that the non-operating aircraft is subjected to repeated daily cycles of air temperature with the solar radiation and wind speed corresponding to the 1 % hot day ambient condition. And, the aircraft was assumed to be in turbulent flow. The convective heat transfer coefficient for turbulent flow on the flat plate suggested by Eckert was employed to calculate heat transfer between the aircraft surface and the ambience. The energy conservation equation on fuel was used as governing equation for this analysis. As a result of this analysis, the wing tank temperature showed the highest temperature and the largest rate of temperature changes among fuel tanks. The results of this analysis could be used as initial foe] temperatures for analysis of the transient fuel temperatures in various flight missions. Also, this analysis method could be used to analysis and design of an aircraft thermal energy management system.

Optimal CO2 Enrichment Considering Emission from Soil for Cucumber Greenhouses

  • Lee, DongHoon;Lee, KyouSeung;Cho, Yong Jin;Choi, Jong-Myoung;Kim, Hak-Jin;Chung, Sun-Ok
    • Horticultural Science & Technology
    • /
    • v.30 no.5
    • /
    • pp.501-508
    • /
    • 2012
  • Reducing carbon dioxide ($CO_2$) exhaust has become a major issue for society in the last few years, especially since the initial release of the Kyoto Protocol in 1997 that strictly limited the emissions of greenhouse gas for each country. One of the primary sectors affecting the levels of atmospheric greenhouse gases is agriculture where $CO_2$ is not only consumed by plants but also produced from various types of soil and agricultural ecosystems including greenhouses. In greenhouse cultivation, $CO_2$ concentration plays an essential role in the photosynthesis process of crops. Optimum control of greenhouse $CO_2$ enrichment based on accurate monitoring of the added $CO_2$ can improve profitability through efficient crop production and reduce environmental impact, compared to traditional management practices. In this study, a sensor-based control system that could estimate the required $CO_2$ concentration considering emission from soil for cucumber greenhouses was developed and evaluated. The relative profitability index (RPI) was defined by the ratio of growth rate to supplied $CO_2$. RPI for a greenhouse controlled at lower set point of $CO_2$ concentration (500 ${\mu}mol{\cdot}mol^{-1}$) was greater than that of greenhouse at higher set point (800 ${\mu}mol{\cdot}mol^{-1}$). Evaluation tests to optimize $CO_2$ enrichment concluded that the developed control system would be applicable not only to minimize over-exhaust of $CO_2$ but also to maintain the crop profitability.

Pbotocatalysis decomposition of TCE in water phase with recirculation photoreactor (Recirculation 광촉매 화학 반응기를 이용한 액상 TCE 분해)

  • 이태규;김동형;조덕기;조서현;오정무
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1993.05a
    • /
    • pp.33-41
    • /
    • 1993
  • The objectives of this experiment performed were to determine the potential using of solar radiation to destroy organic contaminants in water by photolysis and to develop the process and improve its performance. We used lab, scale of recirculation photoreactor with 30, 50, 80ppm initial concentration of TCE and Ti $O_2$ anatase, respectively. Adsorption constant, reaction constant were obtained and compared using the Langmuir-Hinshelwood kinetics equation. Ti $O_2$ anatase demonstrated the highest conversion ratio co TCE among Ti $O_2$ anatase, ZnO and F $e_2$ $O_3$ in this experiment. It was shown that in case of two component system, TCE+ phenol, as the concentration of phenol increased in the feed solution, TCE decomposition rate decreased.

  • PDF

A Study on Isotopic Fractionation between Ice and Meltwater by a Melting Experiment (융해실험에 의한 얼음과 융해수의 안정동위원소분화에 관한 연구)

  • Lee, Jeonghoon;Ham, Ji-Young;Hur, Soon Do
    • Ocean and Polar Research
    • /
    • v.37 no.4
    • /
    • pp.327-332
    • /
    • 2015
  • Isotopic compositions of ice and meltwater play a very crucial role in paleoclimate studies based on ice cores and water resources research conducted in alpine hydrogeology. Better understanding of variations in the stable isotopic compositions of water is required since changes from ice to liquid water are gaining more attention due to recent climate change. In this work, a melting experiment was designed and conducted to investigate how the isotopic compositions of ice vary with time by heat sources, such as solar radiation. We conducted the melting experiment for 22 hours. The discharge rate rose to a maximum value after 258 minutes and gradually declined because we fixed the heat source. The isotopic compositions of meltwater increased linearly or to a second degree polynomial. The linear relationship between oxygen and hydrogen has a slope of 6.8, which is less than that of the Global Meteoric Water Line (8) and higher than a theoretical value (6.3). The deuterium excess decreased when ${\delta}D$ or ${\delta}^{18}O$ increases or vise versa since the slope of the relationship for ice-liquid exchange is less than 8. These findings and the apparatus of the melting experiments will make a helpful contribution to the studies of stable isotopes and the melting process in temperate and polar regions.

Effect of Nitrogen Fertilization on Growth, Forage Yield and Nitrogen Use of Sudangrass (질소시비에 대한 Sudangrass의 생육 및 수량반응과 질소이용성)

  • 윤진일;이호진
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.27 no.1
    • /
    • pp.66-71
    • /
    • 1982
  • Field experiments of nitrogen application (0, 100, 200, 400, 800kg N/ha year) were carried out to study the nitrogen response of Sudangrass at College Farm, Seoul National Univ., in 1979 and 1980. Dry matter yield and leaf area index increased up to 400kg N/ha in 1979 and 800kg N/ha in 1980. The forage yield of 1980 was less than that of 1979, due to the extraordinarily low temperature and the decreased solar radiation during summer. Total nitrogen contents in forage increased with nitrogen application, but maximum contents were found either 400 or 800kg N levels depend on each cutting stages. Nitrate nitrogen content in forage exceded over 2000 ppm at 800kg N application. Overall percentages of N recovery were below 50% with average 34%. Net assimilation rate and nitrogen use efficiency of Sudangrass were improved in higher temperature and more sunlight condition during regrowth period.

  • PDF

Effects of Daylight and Solar Radiation on Indoor Thermal Environment According to Space Structures in Multi-Complex Cultural Center (복합문화시설내 공간 구조에 따른 일조와 일사가 실내 온열환경에 미치는 영향)

  • Choi, Byungbo;Jeon, Hyun Sik;Yoon, Seokil;Kim, Sughwan;Lee, Sang-Jin;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.11
    • /
    • pp.751-758
    • /
    • 2012
  • Recently, people are paying attention to new forms of construction. For example, deviated from an enclosed type space, people have been interested in an atrium type and an arcade type spaces. In this study, we had hypothesis 'Indoor thermal environment will be influenced by the inflow rate of natural lights with temperature and humidity.' We selected a multi-complex cultural center and conducted this study. This place is consisted of atrium, arcade, and enclosed types. The three spaces were classified according to the type of spaces that have own features along with their forms. The atrium type space has ceiling and the side windows, and the arcade type space has ceiling windows. On the other hand, there are no windows or open parts in the enclosed type space. Three measurement points at each space were selected because of their huge space. Intensity of illumination, temperature and humidity were confirmed by the average value of three measurement points. In addition, surveys were conducted regarding indoor comfort elements in each space.