• Title/Summary/Keyword: Solar heating & cooling system

Search Result 178, Processing Time 0.029 seconds

The Daylight and Energy Performance Evaluation of Multi-purpose Solar Window System Using Simulaton Program (시뮬레이션에 의한 다기능 복합 솔라윈도우 시스템의 채광과 에너지성능평가)

  • Jeong, Yeol-Wha;Lee, Seun-Myung
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.103-110
    • /
    • 2011
  • The aim of this study was to analysis the Heating/cooling performance and Daylighting performance of Solar Window System built in apartments. the solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system. The process of this study is as follows: 1)Solar Window system was designed through the investigation of previous paper and work. 2)The simulation program(Lightscape3.2) was used in daylighting performance analysis. the reference model of simulation was made up to analysis daylighting performance on Solar Window system. 3)The simulation program(ESP-r, Therm5.0, Window6.0) was used in energy performance analysis. the reference model of simulation was made up to analysis energy and daylighting performance on Solar Window system. 4)The Size of Simulation model for daylighting and heating/cooling energy analysis was $148.5m^2$ 5)The lighting performance analysis was carried out with various variants, such as the size and installed area of Solar Window system. 6)Energy performance simulation was carried out with various variants, such as Integrated U-value of Solar Window system according to its position, installed angle and insulation thickness. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down at the average of $4.1kWh/m^2$ or 4.2%.

A Methodology of Optimal Design for Solar Heating and Cooling System Using Simulation Tool

  • Lee, Dongkyu;Nam, Hyunmin;Lee, Byoungdoo
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.540-543
    • /
    • 2015
  • Solar energy is one of the most important alternative energy sources which have been shown to meet high levels of heating and cooling demands in buildings. However, the efficiencies to satisfy these demands using solar energy significantly vary based on the characteristics of individual building. Therefore, this paper is focused on developing the methodology which can help to design optimal solar system for heating and cooling to be in cooperated within the existing buildings according to their load profiles. This research has established the Solar Heating and Cooling (SHC) system which is composed of collectors, absorption chiller, boiler and heat storage tank. Each component of SHC system is analyzed and made by means of Modelica Language and Pistache tool is verified the results. Sequential approximate optimization (SAO) and meta-models determined to 15 design parameters to optimize SHC system. Finally, total coefficient of performance (COP) of the entire SHC system is improved approximately 7.3% points compared to total COP of the base model of the SHC system.

  • PDF

A Study on the Economic Analysis of Cooling-Heating System Using Ground Source Heat in a public library (공공도서관에 지열시스템 적용시 경제성에 관한 연구)

  • Choi, Chang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.1
    • /
    • pp.56-66
    • /
    • 2012
  • This study evaluated the economic benefits by comparing Cooling-Heating System with the existing system in the public library. The building's annual energy consumption was measured by adding the figures of the absorber chillers, the air conditioners and heaters in the building. The total amount of annual energy consumption was 143.51RT in air-conditioning and 83.66RT in heating. So, We made the capacity of geothermal heat pumps three 50RTs in order to check up this system. In order to estimate each construction and equipment cost and to evaluate economical efficiency, LCC(Life Cycle Cost) method was used and the service life of the building was sixty years. The result of analysis was that the geothermal cooling-heating system was more efficient than the existing system in public library.

Estimation of Indoor Environment using CFD of Multi-Purpose System with a Solar Collector -Part 1, focused on floor area and number of ventilation- (태양열온수기 적용 냉난방시스템의 CFD를 이용한 실내환경 평가 -제1보 바닥면적과 환기횟수를 중심으로-)

  • Kim, Jong-Ryeol;Choi, Kyang-Hyan
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.55-61
    • /
    • 2007
  • This paper has been conducted to estimate cooling capacity of the dehumidification tower using hot water from a solar water heating system as a energy source of regeneration process when the dehumidification and drying system is applied to room cooling. A solar water heating system was operated and indoor temperature distributions were simulated according to weather conditions when the concerned solution was used to dehumidify room air in the dehumidification tower. Through this simulation researches we found th following results ; It was found that air velocity through supply and return diffusers should be controlled because it can cause uncomfort in dwelling area. It was found that in the sunny morning temperatures of dwelling area 1 and 2 are higher than those of dwelling area 3 and 4. In this research all the calculation results of heating and cooling system supported by solar water heater have confirmed that its cooling capacity could not reach PMV 0, thermal comfort.

The performance evaluation of outdoor unit cooling system in a residential apartment complex (주상복합의 실외기 형태에 따른 냉방시스템 성능 평가)

  • Kyung, Seo-Kyung;Kim, Yun-Jin;Lim, Jung-Hee;Kim, Byung-Seon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.263-268
    • /
    • 2008
  • In a residential complex case, the efficiency of land use are maximized, but a variation of external condition such as load in-equality, the increase in wind velocity and solar radiation by a height causes increasing energy in a building. Besides, because of increasing window size for a lighting and a view, it comes heating load in winter and cooling load in summer. A choice of cooling-system is important for this reason. Recently an internal high-rise residential complex installs an air-cooling system and operates individual heating. However, this study applies water-cooling used one public cooling-tower instead of an air-cooling system, also with an efficiency test of an air and a water-cooling system, consider an internal applicability.

  • PDF

Evaluation of Heating and Cooling Thermal Output Characteristics of Prefabricated Steel Wall Panel System for Radiant Heating and Cooling (강판 마감형 조립식 벽패널 복사냉난방시스템의 냉난방 방열 특성 평가)

  • Lim, Jae-Han;Koo, Bo-Kyoung;Kim, Sung-Im;Song, Seung-Yeong
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.70-77
    • /
    • 2013
  • Recently the radiant panel heating and cooling system has been regarded as an alternative of low temperature heating and high temperature cooling by applying the renewable energy sources to the heating and cooling of buildings. Especially this system can be used as HVAC system alternatives in super high-rise buildings for energy saving and thermal comfort. Also it can be possible to reduce the plenum space because the minimum ventilation air will be supplied into the space. This study focused on the evaluation the basic characteristics of thermal output in prefabricated steel wall panel system for radiant heating and cooling. In order to evaluate the thermal output according to both various supply water temperatures and supply water flow rates, three-dimensional dynamic heat transfer analysis was performed. As results, for the heating mode, thermal output increased by 26% with the supply temperature increasing by $5^{\circ}C$. The surface temperature of panels range within $1{\sim}3^{\circ}C$. For the cooling mode, thermal output decreased by 18.2% with the supply temperature increasing by $2^{\circ}C$. The surface temperature of panels range within $0.5{\sim}1^{\circ}C$ and it was shown the even temperature distribution.

TRNSYS Dynamic Simulation for Solar Heating and Cooling Load Estimations (태양열 냉난방 부하산정을 위한 TRNSYS 동적 시뮬레이션)

  • Choi, Chang-Yong;Ko, Sang-Cheol;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • This paper presents the heating and cooling load estimations for the library of a cultural center building located in Gwangju Korea by TRNSYS with Type 56 of multi-zone building components. In this study, energy rate control mode is selected and the design temperatures for heating and cooling are specified respectively as 20oC and 26oC. Reading rooms of the library are located on the third floor of the cultural center building, and this third floor space is modeled as the five thermal zones for the TRNSYS simulation. Among the five zones, attention is given to the two zones which are the reading rooms 1 and 2. Since these two zones are to be heated and cooled by the solar thermal system which is planned to be installed in the building, dynamic thermal behaviors of the two zones are analyzed by the heating and cooling load estimations.

A Study on the Application of the Solar Energy Seasonal Storage System Using Sea water Heat Source in the Buildings (해수냉열원을 이용한 태양열계간축열시스템의 건물냉방 적용에 관한 연구)

  • Kim, Myung-Rae;Yoon, Jae-Ock
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.56-61
    • /
    • 2009
  • Paradigm depending only on fossil fuel for building heat source is rapidly changing. Accelerating the change, as it has been known, is obligation for reducing green house gas coming from use of fossil fuel, i.e. reaction to United Nations Framework Convention on Climate Change. In addition, factors such as high oil price, unstable supply, weapon of petroleum and oil peak, by replacing fossil fuel, contributes to advance of environmental friendly renewable energy which can be continuously reusable. Therefore, current new energy policies, beyond enhancing effectiveness of heat using equipments, are to make best efforts for national competitiveness. Our country supports 11 areas for new renewable energy including sun light, solar heat and wind power. Among those areas, ocean thermal energy specifies tidal power generation using tide of sea, wave and temperature differences, wave power generation and thermal power generation. But heat use of heat source from sea water itself has been excluded as non-utilized energy. In the future, sea water heat source which has not been used so far will be required to be specified as new renewable energy. This research is to survey local heating system in Europe using sea water, central solar heating plants, seasonal thermal energy store and to analyze large scale central solar heating plants in German. Seasonal thermal energy store necessarily need to be equipped with large scale thermal energy store. Currently operating central solar heating system is a effective method which significantly enhances sharing rate of solar heat in a way that stores excessive heat generating in summer and then replenish insufficient heat for winter. Construction cost for this system is primarily dependent on large scale seasonal heat store and this high priced heat store merely plays its role once per year. Since our country is faced with 3 directional sea, active research and development for using sea water heat as cooling and heating heat source is required for seashore villages and building units. This research suggests how to utilize new energy in a way that stores cooling heat of sea water into seasonal thermal energy store when temperature of sea water is its lowest temperature in February based on West Sea and then uses it as cooling heat source when cooling is necessary. Since this method utilizes seasonal thermal energy store from existing central solar heating plant for heating and cooling purpose respectively twice per year maximizing energy efficiency by achieving 2 seasonal thermal energy store, active research and development is necessarily required for the future.

  • PDF

Simnlation of a Thermal Behavior in Solar Heating and Cooling System with respect to Demand Room Temperature (실내 설정온도에 따른 태양열 냉난방 시스템의 동적 거동 해석)

  • Jang, H.Y.;Lee, S.B.;Chung, K.T.;Suh, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3446-3451
    • /
    • 2007
  • The thermal behavior of a building in response to heat input from an active solar space heating system is analysed to determine the effect of the variable storage tank temperature on the cycling rate, on and off temperature of a heating cycle and on the comfort characteristics of room air temperature. A computer simulation of the system behavior has been performed and verified by comparisons with various parameters. Especially, this study is focused on the effect of the system's performance when subjected to dynamic cooling loads. The heat input to the absorption system is provided by an array of solar collectors that coupled to a thermal storage tank.

  • PDF

Solar Absorption System Analysis with Spreadsheet Models (태양열 이용 흡수식 냉난방시스템의 스프레드쉬트 모델)

  • Choi, Hong-Kyu;Fazzolari, Rocco A.
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.15-24
    • /
    • 1992
  • An hourly simulation model of a solar LiBr-water absorption cooling and heating system (for brevity, solar absorption system) is presented, based on SuperCalc spreadsheet computational procedures. This paper demonstrates the value of using spreadsheet simulation techniques by examining the thermal performances of a solar absorption system. The hourly heating and cooling coil loads for a typical office building in Tucson, Arizona are modeled and calculated using ASHRAE methods. The details of the algorithms for the components and control schemes are presented. Two case studies are also presented using real system parameters.

  • PDF