• Title/Summary/Keyword: Solar heater

Search Result 122, Processing Time 0.023 seconds

Optimal Design of Cz Process for Increasing a Productivity of Single Crystal Si Solar Cell Ingot (태양전지용 단결정 실리콘 잉곳 생산성 증대를 위한 초크랄스키 공정 최적 설계)

  • Lee, Eunkuk;Jung, Jae Hak
    • Korean Chemical Engineering Research
    • /
    • v.49 no.4
    • /
    • pp.432-437
    • /
    • 2011
  • Recently, industry needs a new design of Czochralski(Cz) process for higher productivity with reasonable energy consumption. In this study, we carried out computational simulations for finding out a new optimal design of Cz process with variables which can be applied in real industry such as location of heater, shape of shield and crucible size. Objective process was Cz process which can be produced 8 inch diameter Si ingot for solar cell and we acquired an optimal design for higher productivity, low power consumption with stable production condition. For higher productivity we also change the crucible diameter from 22 inches to 24 inches with changing insulation thickness only because the process housing size could not be changed in industry.

Operating characteristics of 3RT heat pumps

  • Moon, Chang-Uk;Choi, Kwang-Hwan;Yoon, Jung-In;Jeon, Min-Ju;Heo, Seong-Kwan;Sung, Yo-Han;Park, Sung-Hyeon;Lee, Jin-Kook;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.2
    • /
    • pp.140-145
    • /
    • 2017
  • Newly designed vapor-injection heat pumps have been proposed and analyzed in the present study. An economizer-type vapor-injection (V-I) system has been employed as the standard system because of its reliability and simple control method. The V-I system has a re-cooler and re-heater for cooling and heating, respectively. Solar panels have been installed in the V-I heat pump as well as in the re-heater in order to enhance heating capacity and performance. R410A has been employed as a working fluid and performance analysis has been conducted under various conditions. Results are summarized as follows: (1) The V-I system with the re-cooler yielded a marginally higher coefficient of performance (COP) than the conventional V-I refrigeration system. (2) By increasing the re-cooler cooling capacity, enhanced system performance as compared to the conventional V-I system was observed. (3) The re-heater negatively affected the system performance; hence, the V-I heat pump with the re-heater yielded a lower COP than that of the conventional V-I heat pump used for heating. (4) Although the solar panels increased the system performance, this increase could not offset performance degradation by the re-heater.

Study on Solar Tracker Control Method using AC Motor and CdS Sensor (AC 모터 및 CdS 센서를 이용한 태양 추적 장치 제어 방법에 관한 연구)

  • Kim, Bo-Heon;Kim, Hwang-Rae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.294-301
    • /
    • 2016
  • Recently, the solar tracker has been used to improve the efficiency of solar energy. Solar tracking technologies are classified into the sensor-based method, the program-based method, and the hybrid method. Solar trackers using an AC motor and CdS sensor are low in cost, but the precision of the positions is low, owing to the inertia of the motor and the scattering of sunlight. To compensate for the low precision, we implement a CdS sensor module and propose an AC motor control method using error value. To evaluate the performance of the solar tracker, we implemented a solar water heater. From the experimental results, the solar tracker can achieve ${\pm}2mm$ accuracy for sun, can satisfy ${\pm}15mm$ as a limited error value, and provides a 32% performance enhancement in KSB8202 criteria.

Power System Design for Next Generation LEO Satellite Application (차세대 저궤도 소형위성 적용을 위한 전력시스템 설계)

  • Park, Sung-Woo;Park, Hee-Sung;Jang, Jin-Beak;Jan, Sung-Soo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.283-287
    • /
    • 2005
  • In this paper, one general approach is proposed for the design of power system that can be applicable for next generation LEO satellite application. The power system consists of solar panels, battery, and power control and distribution unit(PCDU). The PCDU contains solar array modules, battery interface modules, low-voltage power distribution modules, high-voltage distribution modules, heater power distribution modules, on-board computer interface modules, and internal DC/DC converter modules. The PCDU plays roles of protection of battery against overcharge by active control of solar array generated power, distribution of unregulated electrical power via controlled outlets to bus and instrument units, distribution of regulated electrical power to selected bus and instrument units, and provision of status monitoring and telecommand interface allowing the system and ground operate the power system, evaluate its performance and initiate appropriate countermeasures in case of abnormal conditions. We review the functional schemes of the main constitutes of the PCDU such as the battery interface module, the auxiliary supply module, solar array regulators with maximum power point tracking(MPPT) technology, heater power distribution modules, spacecraft unit power distribution modules, and instrument power distribution module.

  • PDF

Convective Heat Loss from Solar Tower Receiver with Tilt Angles and Operating Conditions (Solar Tower용 흡수기의 설치 각도 및 작동 조건 변화에 따른 대류 열손실 분석)

  • Kang, Kyung-Mun;Lee, Ju-Han;Kim, Yong;Seo, Tae-Beom;Kang, Yong-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.121-128
    • /
    • 2007
  • Convective heat loss from solar tower receiver is experimentally investigated in wind tunnel with tilt angles and operating conditions. In order to simulate the receiver, an electric heater, which is made of aluminum (width : 100 mm, height : 100mm) is used and installed in the wind tunnel. The convective heat loss from the receiver is dependent on the direction and the velocity of the wind and the surface temperature of the receiver. The tilt angle and surface temperature of the receiver are varied from 0o (cavity facing straight down) and 90o(cavity aligned horizontally) and from $150^{\circ}C$ to $250^{\circ}C$, respectively. Also, the wind speed is changed from 0 to 4m/s. The convective heat loss is obtained by measuring consumed power to the heater to maintain the desired surface temperature. It is concluded that Nusselt number increases with increasing wind speed for all cases. Especially, it is showed that Nusselt number can be maximized when the tilt angle is 30o.

Effect of channel hight on Bubble growth under Saturated Nucleate Pool Boiling for Various Channel Height using Heater with Artificial Cavity (인공 캐비티를 가진 히터를 이용한 가열면의 채널 높이가 풀비등시 기포성장에 미치는 영향에 대한 기초연구)

  • Kim, Jeong-Bae;Park, Moon-Hee;Jeon, Woo-Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.93-99
    • /
    • 2010
  • Nucleate pool boiling experiments with constant heat flux condition were performed using pure R113 for various channel heights under saturated pool condition. A circular heater of 1mm diameter, with artificial cavity in the center, fabricated using MEMS technique and the high-speed controller were used to maintain the constant heat flux. Images of bubble growth were taken at 5,000 frames per second using a high-speed CCD camera. The bubble geometry was obtained from the captured bubble images. The effects of channel height on the bubble growth behaviors were analyzed as dimensional scales for the initial and thermal growth regions. The parameters for the bubble growth behaviors were bubble radius, bubble growth rate, and bubble shapes. These phenomena require further analysis for various surface angles, but this study will provide good experimental data with constant heat flux boundary condition for such works.

Heat Transfer Characteristics under Saturated Nucleate Pool Boiling for Various Heating Surface Angles using Heater with Artificial Cavity (인공 캐비티를 가진 히터를 이용한 가열면 경사각에 따른 포화상태 풀 핵비등 열전달 기초연구)

  • Kim, Jeong-Bae
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.4
    • /
    • pp.7-14
    • /
    • 2009
  • Nucleate pool boiling experiments with constant heat flux condition were performed using pure R11 and R113 for various surface angles under saturated pool condition. A circular heater of 1 mm diameter, with artificial cavity in the center, fabricated using MEMS technique and the high-speed controller were used to maintain the constant heat flux. Images of bubble growth were taken at 5,000 frames per second using a high-speed CCD camera. The bubble geometry was obtained from the captured bubble images. The effects of surface angles on the bubble growth behaviors were analyzed as dimensional scales for the initial and thermal growth regions. The parameters for the bubble growth behaviors were bubble radius, bubble growth rate, sliding velocity, bubble shape and advancing and receding contact angles. These phenomena require further analysis for various surface angles, but this study will provide good experimental data with constant heat flux boundary condition for such works.

Experimental Studies for Solar Drying System of Agricultural Products(I) - Solar drying characteristics for radish - (태양열 건조 시스템에 관한 실험적 연구(I) - 무우절편의 태양열 건조 특성 -)

  • Koh, Hak-Kyun;Kim, Yong-Hyeon;Song, Dae-Bin;Kim, Man-Soo
    • Solar Energy
    • /
    • v.11 no.3
    • /
    • pp.9-20
    • /
    • 1991
  • Experiments for drying radish were carried out to analyze the drying characteristics and quality evaluation between solar heated-air drying and natural air drying system. Solar heated-air drying system consists of a small fan, a solar air heater and a tunnel dryer. Simulation model for thermal environments of solar collector was developed to investigate the effect of solar radiation and airflow rate on thermal performance.

  • PDF

A Computer Simulation of the Combustion and Flueway of a Pulse Combustion Water Heater (맥동연소온수기의 연소실과 노도의 컴퓨터 시뮬레이션)

  • Kang, Kun;Shin, Sei-Kun;Kim, Min-Sik
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.64-72
    • /
    • 1989
  • In this study, the computer simulation for the heat transfer in pulse combustion water heater is performed. The attention is focused to the effects of the installation of corebuster in the flue tube on heat transfer. The energy equations are established for both wall and gas side in the combustion chamber, flue way, exhaust chamber and muffler, and the numerical calculation is executed. Zone method takes longer computer calculation time compared with semi-zone method. Semi-zone method is chosen for numerical calculation. As a result of this study, it is found that the installation of the core buster in flue tube increases total heat transfer. It is also found that the total heat transfer is increased with the increasing of the ratio of the cross section area of corebuster to that of the flue tube. However, the heat transfer effect is negligible for the area ratio above 0.5.

  • PDF

Experimental Study on Heat Losses from Receiver of Solar Thermal Power (태양열발전용 흡수기 설게 및 열손실 특성실험)

  • Kim, Jong-Kyu;Kang, Yong-Heack;Kim, Jin-Soo;Lee, Sang-Nam;Yu, Chang-Kyun;Yun, Hwan-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.672-675
    • /
    • 2007
  • Experimental data are presented which describe heat losses of cavity type receiver in wind tunnel. Experiments are conducted at various conditions such as the heater temperature in cavity changes from 300, 400, and 500 oC, wind speed in tunnel from 2 to 8 m/s, and four different tilt angle of 30, 50, 70, 90o. The power consumption including temperature, voltage and current for each experimental conditions are measured and stored in data logger at everyone second interval. The experimental results show that heat losses increase with increasing wind speed and with tilt angle. However, heat losses for the tilt angle of 70 and 90o is almost same at each heater temperature. In addition, the effects of natural convection in combined convection heat losses vary in according to the tilt angle.

  • PDF