• Title/Summary/Keyword: Solar cell connection

Search Result 61, Processing Time 0.033 seconds

Demonstration Analysis of 3kW Grid Connected PV System (3kW급 계통연계형 태양광발전시스템 실증연구)

  • Choi Y.O.;Piao Z.G.;Jeong S.B.;Cho G.B.;Baek H.L.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.558-560
    • /
    • 2006
  • Solar cell converts sunlight into the electricity that one of the most versatile forms of energy. It has been developed and applied on residental electric power system by urbanized countries as a alternative energy source to overcome energy problem after oil shock. This paper summarizes the results of these efforts by offering a snapshot of the configuration of photovoltaic in residential applications. The status of PV system components and inter-connection and safety equipment will be summarized. Hence this paper discusses only points that might be useful for application.

  • PDF

A study on Generation Efficiency with Variation of Solar Cell Array (태양전지어레이 가변에 의한 발전효율에 관한연구)

  • Kim, K.B.;Choi, Y.O.;Seo, J.Y.;Kim, D.H.;Cho, G.B.;Baek, H.L.
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.247-250
    • /
    • 2002
  • This paper presents a utility interactive photovoltaic generation system with the angle of inclination and direction. This paper summarizes the results of these efforts by offering a snapshot of the configuration of photovoltaic in residential applications. The status of PV system components and inter -connection and safety equipment will be summarized. also, This System is able to variation the angle of inclination and direction. Hence this paper discuss only results that might be useful for generation power.

  • PDF

ESS Design and Performance Evaluation Considering Efficiency of Energy Distribution (에너지 분배의 효율성을 고려한 ESS 설계 및 성능 평가)

  • Kang, Jin-Gu
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2017.07a
    • /
    • pp.392-393
    • /
    • 2017
  • 본 연구에서는 에너지 저장시스템인 ESS 에너지 분배에 관한 시스템을 설계 및 제작하고 성능을 평가하였다. ESS에 충전하는 방법은 현재 기존의 상용전원을 전지에 충전하는 방식과(연계형) 태양광 에너지를 이용한 방법(독립형)으로 나누어져 있다. 본 연구에서는 어느 한쪽을 선택해야하는 번거로움을 줄여 상용전원과 태양광을 동시에 충전할 수 있는 시스템으로 설계하였다. 이러한 방법은 날씨 및 기타 외부적 환경이 좋지 않을 경우 일반 상용전원(AC 220V)를 이용하며 외부적 환경이 좋을 때는 태양전지로 충전이 가능하도록 연계형과 독립형이 동시에 가능하도록 구성하였다. 또한 출력에서 기존의 AC 220V 출력뿐만 아니라 DC12V, 24V의 전압과 USB(5V)도 동시에 출력이 가능하게 설계하므로 필요한 전압을 외부의 인버터나 컨버터가 필요 없이 바로 사용할 수 있도록 배분하였다. 따라서 본 연구에서는 ESS의 전력을 효율적으로 배분하므로 효율성을 증가시키고 내부의 배터리를 보호하는 시스템을 구성하여 그 성능평가를 실시하였으며 실험결과 효율적으로 배분된 전력을 얻을 수 있음을 검증하였다.

  • PDF

Demonstration Analysis of 3kW Integrated PV System (3kW급 일체형 계통연계 태양광발전 시스템 실증연구)

  • Cho, A.O.;Kim, J.H.;Na, J.D.;Choi, M.H.;Park, S.K.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.727-729
    • /
    • 2005
  • Solar cell converts sunlight into the electricity that one of the most versatile forms of energy. It has been developed and applied on residental electric power system by urbanized countries as a alternative energy source to overcome energy problem after oil shock. This paper summarizes the results of these efforts by offering a snapshot of the configuration of photovoltaic in residential applications. The status of PV system components and inter -connection and safety equipment will be summarized. Hence this paper discusses only points that might be useful for application.

  • PDF

Solar Cell Arrays Connection of Large Scale PV System (대규모 PV시스템의 태양전지 어레이 구성법)

  • Yu, Gwon-Jong;Song, Jin-Soo;Ro, Myong-Gun;Sung, Se-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.326-328
    • /
    • 1996
  • The 10kW or 1MW model of a photovoltaic array written in PSPICE is presented in this paper. A problem with this large scale centralized photovoltaic system is the decrease of power due to the resistance of cable connecting individual subarray with inverter. In this paper, we analyzed the relationship between the resistance of cable and subarray output power of 1MW photovoltaic system by the PSPICE modeling. As a result of simulation, we can proved that photovoltaic array output power is limitted by the resistance of cable.

  • PDF

A Study on Grid-connected Photovoltaic Current-Source Inverter using Parallel Connection (병렬연결을 이용한 계통연계형 태양광 전류형 인버터에 관한 연구)

  • Lim, Joung-Min;Cheang, Eui-Heang;Moon, Chae-Joo;Chang, Young-Hak;Kim, Eui-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1222-1223
    • /
    • 2007
  • This paper suggests a 6-pulse-shift converter with PWM current-source inverter based on buck-boost configuration to improve the efficiency and to reduce the switching frequency of inverter for photovoltaic generation system, the device can be operated as interface system between solar module system and power system grid without energy storage cell. the circuit has six current-source buck-boost converter which operate chopper part has one full bridge inverter which make a decision the polarity of AC output. Therefore, the proposed PWM power inverter has advantages such as the reduction of witching loss and realization of unity power factor operation. the theoretical backgrounds are discussed and the input-output characteristics for the implemented prototype inverter using TMS320F2812 are verified experimentally in this paper.

  • PDF

Guard Lamp using Solar Cell (태양광을 이용한 정원등)

  • Kang Byung-Bog;Cha In-Su;Lim Jung-Yeol;Yoon Jeong-Phil;Park Se-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.129-132
    • /
    • 2004
  • A guard lamp system has been installed at the PV positive center, located at Gwangju in Korea. Digital environment that is represented to internet is displacing business way of industry and business achievement way with the fast speed being giving great change on life whole, improve existence business process utilizing internet and Web connection technology, information superhighway to tradition industrialist manufacture and e-transformation's propulsion that wish to maximize productivity and administration efficiency is spread vigorously. In this paper, we wish to accomplish generation equipment's heighten stability and believability through remote monitoring and control of guard lamp system. This paper describes the design of the monitoring system for the sensing data and indirect controlling of the guard lamp system. Most of the conventional monitoring systems depend on the special hardware and software. The essential design of monitoring system is to provide the convenience for the user and the portability for the system. In order for the system to fulfill its requirements, it was designed using Labview GUI facility based on the Windows 2000 environment of IBM PC compatible and Add-oncard based on the TCP/IP protocol. Advantage of the monitoring system are a personnel expenses curtailment effect, of the place restriction and unmanned system of the generationplants, etc..

  • PDF

CHARACTERISTIC ANALYSIS FOR GUARD LAMP USING SOLAR CELL (솔라셀을 적용한 보안등의 특성 분석에 관한 연구)

  • Kang, Byung-Bog;Ji, Woon-Seok;Lim, Jung-Yeol;Yu, Chang-Woo;Kim, Seok-Jong;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.196-200
    • /
    • 2004
  • A guard lamp system has been installed at the PV positive center, located at Gwangju in Korea. Digital environment that is represented to internet is displacing business way of industry and business achievement way with the fast speed being giving great change on life whole, improve existence business process utilizing internet and Web connection technology, information superhighway to tradition industrialist manufacture and e-transformation's propulsion that wish to maximize productivity and administration efficiency is spread vigorously. In this paper, we wish to accomplish generation equipment's heighten stability and believability through remote monitoring and control of guard lamp system. This paper describes the design of the monitoring system for the sensing data and indirect controlling of the guard lamp system. Most of the conventional monitoring systems depend on the special hardware and software. The essential design of monitoring system is to provide the convenience for the user and the portability for the system. In order for the system to fulfill its requirements, it was designed using Labview GUI facility based on the Windows 2000 environment of IBM PC compatible and Add-on card based on the TCP/IP protocol. Advantage of the monitoring system are a personnel expenses curtailment effect, of the place restriction and unmanned system of the generation plants, etc..

  • PDF

THE CHARACTERISTIC OF SOLAR CELL FOR GUARD LAMP (보안등에 적용하기 위한 태양전지의 특성 분석)

  • Kang Byung-Bog;Ji Woon-Seok;Lim Jung-Yeol;Kim Seok-Jong;Yu Chang-Woo;Cha In-Su
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1489-1491
    • /
    • 2004
  • A guard lamp system has been installed at the PV positive center, located at Gwangju in Korea. Digital environment that is represented to internet is displacing business way of industry and business achievement way with the fast speed being giving great change on life whole, improve existence business process utilizing internet and Web connection technology, information superhighway to tradition industrialist manufacture and e-transformation's propulsion that wish to maximize productivity and administration efficiency is spread vigorously. In this paper, we wish to accomplish generation equipment's heighten stability and believability through remote monitoring and control of guard lamp system. This paper describes the design of the monitoring system for the sensing data and indirect controlling of the guard lamp system. Most of the conventional monitoring systems depend on the special hardware and software. The essential design of monitoring system is to provide the convenience for the user and the portability for the system. In order for the system to fulfill its requirements, it was designed using Labview GUI facility based on the Windows 2000 environment of IBM PC compatible and Add-oncard based on the TCP/IP Protocol. Advantage of the monitoring system are a personnel expenses curtailment effect, of the place restriction and unmanned system of the generationplants, etc..

  • PDF

A Study on Power Trading Methods for in a Hydrogen Residential Model (수소주거모델의 전력 거래 참여 방안 고찰)

  • KISEOK JEONG;TAEYOUNG JYUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.2
    • /
    • pp.91-99
    • /
    • 2023
  • Participation in power trading using surplus power is considered a business model active in the domestic energy trade market, but it is limited only if the legal requirements according to the type, capacity, and use of the facilities to be applied for are satisfied. The hydrogen residential demonstration model presented in this paper includes solar power, energy storage system (ESS), fuel cell, and water electrolysis facilities in electrical facilities for private use with low-voltage power receiving system. The concept of operations strategy for this model focuses on securing the energy self-sufficiency ratio of the entire system, securing economic feasibility through the optimal operation module installed in the energy management system (EMS), and securing the stability of the internal power balancing issue during the stand-alone mode. An electric facility configuration method of a hydrogen residential complex demonstrated to achieve this operational goal has a structure in which individual energy sources are electrically connected to the main bus, and ESS is also directly connected to the main bus instead of a renewable connection type to perform charging/discharging operation for energy balancing management in the complex. If surplus power exists after scheduling, participation in power trading through reverse transmission parallel operation can be considered to solve the energy balancing problem and ensure profitability. Consequentially, this paper reviews the legal regulations on participation in electric power trading using surplus power from hydrogen residential models that can produce and consume power, gas, and thermal energy including hybrid distributed power sources, and suggests action plans.