• Title/Summary/Keyword: Solar Thermal Cooling

Search Result 226, Processing Time 0.018 seconds

Optimal Thermal Design of a Single Heat Source in a Cavity (Cavity내의 단일 열원에 대한 최적 열적설계)

  • Yae, Y.T.;Choo, H.L.;Kim, H.W.
    • Solar Energy
    • /
    • v.19 no.1
    • /
    • pp.77-86
    • /
    • 1999
  • The optimal thermal design of a single heat source on one wall of a vertical open top cavity was studied experimentally. The temperature and flow fields in the cavity were visualized. The objectives of this study is to obtain the best location of the single heat source and to examine the effects of heat source protrusion, substrate thermal conductivity and cavity aspect ratio on the natural convection cooling due to a single heat source. As the results, the cooling effect for the copper substrate is superior to that of the epoxy-resin substrate and is improved with increasing cavity width. For the epoxy-resin substrate of lower conductivity, the protrusion of the heaters plays a role in decreasing the cooling effect. The best location was the mid-height of the substrate.

  • PDF

Energy Generating Self-cooling Greenhouse (열-전기 병합 에너지 생산 겸 자체 냉각 온실)

  • Kleinwachter, Jurgen;Chung, Mo;Kim, Jong-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.584-587
    • /
    • 2006
  • An energy generating greenhouse based on fluoropolymer envelope and fresnel lens is proposed. The outstanding properties of the fluoropolymer films make them very suitable for large scale solar applications. Extremely high optical transmission over the whole solar spectrum, combined with mechanical strength, and durability allows us to design a highly optimized greenhouses for both plant growing and energy generation. Systems such as photovoltaic triple junction cells are especially attractive since they have up to 35% efficiency with much less cell material when the sun beam is focused with concentrators such as fresnel lenses. Cooling such devices will enhance the efficiency and provide useful thermal energy that could be further utilized for various applications depending on the local demands. This article introduces the basic ideas and principles of the energy generating greenhouses as a first step towards the actual deployment of such systems under Korean environment.

  • PDF

A Study on the Heat Exchange Performance for the Liquid Based Solar Thermal Storage (Liquid Based Solar Thermal Storage를 위한 열교환성능(熱交換性能)에 관한 연구(硏究))

  • Kim, Byung-Chul;Jung, Hyun-Chai
    • Solar Energy
    • /
    • v.5 no.2
    • /
    • pp.35-45
    • /
    • 1985
  • A solar hot water storage tank was designed and constructed to examine the heat exchange performances on load side for the solar thermal storage in a single loop solar water heating system. In the tank helically coiled tube was immersed. The hot water was circulated from either top or bottom. The circulation flow rate was varied from 500 ml/min to 20,000 ml/min. The effect of flow rate was observed. The thermal performances according to the flow rate and flow direction were examined. The temperature distributions in the tank and inside of the tubes were plotted along the process of cooling.

  • PDF

Analysis of Thermal Performance of Ground-Source Heat Pump System (지열 이용 히트펌프 시스템의 열성능 해석)

  • Shin, U-Cheul;Baek, Nam-Choon;Kim, Ook-Joong;Koh, Deuk-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.2
    • /
    • pp.95-101
    • /
    • 2006
  • The purpose of this study is to present the simulation results and an overview of the performance assessment of the Ground-Source Heat Pump(GSHF) system. The calculation was performed for two design factors: the spacing between boreholes and the depth of the vertical ground heat exchangers. And the simulation was carried out using the thermal simulation code TRNSYS with new model of water to water heat pump developed by this study. As a result, it was anticipated that the yearly mean COPs of heat pump for heating and cooling are about 3.7 and 5.8 respectively and the heat pump can supply 100% of heating and cooling load all the year around.

A Comparative Analysis of Energy Simulation Results and Actual Energy Consumption on Super High-rise Apartments (초고층 공동주택의 세대별 냉난방부하 시뮬레이션 결과 및 에너지 실사용량과의 비교 분석)

  • Suh, Hye-Soo;Kim, Byung-Seo
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.34-40
    • /
    • 2011
  • Apartment Housing has been increasing steadily, particularly our current super high-rise apartment houses that represent the culture has become a trend in Korea. These super high-rise apartment houses' curtain wall system increases heating and cooling loads, it is expected to vary by each unit's thermal properties. In this study, measured indoor environment and energy simulation results were compared to actual energy consumption. As a result, the various factors that affect heating and cooling loads, such as direction, plan type and glazing area, influence each unit's load characteristic. In particular, according to the electricity costs savings behavior, the occupant's thermal discomfort is expected to be large in summer. Therefore, to reduce heating and cooling load for each unit requires a reasonable plan.

Thermal and Fluid Flow of the Air Layer in a Flat Type Solar Collector (평판형 태양열 집열판 공기층의 열 및 유체유동)

  • Bae, K.Y.;Yi, C.S.;Lee, K.S.;Chung, H.S.;Jeong, H.M.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.3
    • /
    • pp.61-68
    • /
    • 2001
  • This study represents numerical analysis on the thermal and fluid flow of the air layer in a solar collector. The boundary conditions was assumed that the top and bottom wall of the air layer have a heating and cooling surface, respectively, and this calculation model have a solid body with a cooling temperature of $20^{\circ}C$. As the results of simulations, the magnitudes of the velocity vectors and isotherms are increased proportionally to the tilt angles. As the tilt angle is increased, the mean Nusselt numbers are increased and the maximum value of the mean Nusselt number was appeared at tilt angle $\theta=75^{\circ}$.

  • PDF

Additional power conservation in 200W power plant with the application of high thermal profiled cooling liquid & improved deep learning based maximum power point tracking algorithm

  • Raj G. Chauhan;Saurabh K. Rajput;Himmat Singh
    • Advances in Energy Research
    • /
    • v.8 no.3
    • /
    • pp.185-202
    • /
    • 2022
  • This research work focuses to design and simulate a 200W solar power system with electrical power conservation scheme as well as thermal power conservation modeling to improve power extraction from solar power plant. Many researchers have been already designed and developed different methods to extract maximum power while there were very researches are available on improving solar power thermally and mechanically. Thermal parameters are also important while discussing about maximizing power extraction of any power plant. A specific type of coolant which have very high boiling point is proposed to be use at the bottom surface of solar panel to reduce the temperature of panel in summer. A comparison between different maximum power point tracking (MPPT) technique and proposed MPPT technique is performed. Using this proposed Thermo-electrical MPPT (TE-MPPT) with Deep Learning Algorithm model 40% power is conserved as compared to traditional solar power system models.

Evaluation on the Cooling Performance of Geothermal-energy Using Heat Pump System in Mixed-use Residential Building (주상복합 건축물에 적용된 지열이용 히트펌프 시스템의 냉방성능 평가)

  • Kim, Yong-Shik;Kim, Jung-Heon;Hwang, Kwang-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.9-16
    • /
    • 2006
  • Geothermal-energy has been getting popular as a natural energy source for green buildings these days. Public building with gross area more than $3000m^2$, planned after March, 2005, should spend about 5% of total building cost for equipment run by natural energy source (e.g. geothermal, solar heat, solar power, etc) according to renewable energy promotion law in Korea. As a result geothermal-energy using heat pump system is emerging as a effective alternative for realistic and economic plan although design guidelines and construction code for the system is in progress and technical data is far from sufficient. The quantitative analysis on the performance of geothermal-energy using heat pump system is insufficient for appropriate design of it. In this paper, cooling performance of geothermal-energy using heat pump system of residential and retail etc. mixed-use building has been analyzed on the basis of temperature comparison between inlet and outlet of heat exchangers of the operating system. Additionally, dry-bulb temperature and relative humidity have been measured and analyzed together as an index of indoor thermal environment.

A Study on the Operating Characteristics of Solar Collecting System in Solar Thermal/Geothermal Hybrid System with Facade Integrated Solar Collector (Facade 일체형 태양열 집열기를 갖는 태양열/지열 하이브리드 시스템의 태양열 집열시스템 작동특성 연구)

  • Baek, Nam-Choon;Lee, Jin-Kook;Yu, Chang-Kyun;Yoon, Eung-Sang;Yoon, Jong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.69-76
    • /
    • 2010
  • In this study, the solar thermal and geo-source heat pump(GSHP) hybrid system for heating and cooling of Zero Energy Solar House(ZESH) was analyzed by experiment. The GSHP in this hybrid system works like as aback-up device for solar thermal system. This hybrid system was designed and installed for Zero Energy Solar House (KIER ZeSH) in Korea Institute of Energy Research. The purpose of this study is to find out that this system is optimized and operated normally for the heating load of ZeSH. The analysis was conducted as followings ; - the thermal performance of facade integrated solar collector - the on/off characteristics of solar system and GSHP - the contribution of solar thermal system. - the performance of solar thermal and ground source heat pump system respectively. - the meet of thermal load (space and water heating load). This experimental study could be useful for the optimization of this system as well as its application in house. This hybrid system could be commercialized for the green home if it is developed to a package type.

Comparison of Annual Heating and Cooling Loads of Internally and Externally Insulated Apartment Buildings According to the Location of Thermal Mass (내, 외단열 공동주택의 축열체 위치 차이에 따른 동단위 연간 냉난방부하 비교평가)

  • Koo, Bo-Kyoung;Lee, Beung-In;Choi, Doo-Sung;Song, Seung-Yeong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.42-49
    • /
    • 2010
  • The IIS(Internal Insulation System) is applied in most Korean apartment buildings which are the most common type of residential buildings. Consequently, there are many cases in which the layer of insulation is disconnected by the structural components at the wall-slab and wall-wall joints in the envelope. These joints become thermal bridges where the risk of heat loss increases. It is expected that the EIFS(External Insulation and Finish System) is the solution to this problem. In this study, annual heating and cooling loads of apartment buildings with IIS and EIFS were compared using Design Builder program in order to evaluate the thermal storage effect of EIFS where the concrete thermal mass is located inside of the insulation material. As results, the apartment building with EIFS could reduce annual heating and cooling loads by 2.4% and 4.1%, respectively.