• Title/Summary/Keyword: Solar Thermal Apartment

Search Result 47, Processing Time 0.022 seconds

A Study on the optimized Performance Designing of the Window of the Apartment based on the Annual Energy Demand Analysis according to the Azimuth Angle applying the Solar Heat Gain Coefficient of the Window (창호에 SHGC를 반영한 공동주택의 방위각별 에너지 효율성 평가를 통한 합리적인 창호 계획 방안 연구)

  • Lee, Jang-bum
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.11
    • /
    • pp.25-34
    • /
    • 2019
  • It is important to design windows in a reasonable way considering the performance characteristics of the elements of the window rather than just to increase the thermal energy performance of the window. In this study, the Heat-transfer Coefficient as insulation performance of the windows and together with the grade of the glass's SHGC (Solar Heat Gain Coefficient) were analyzed to relate to the energy efficiency performance of the building by azimuth angle. Based on this basic study, the Heat-transfer Coefficient of windows and the SHGC rating of glass were applied to the unit plan of apartment building, and the Heating and Cooling Demand were analyzed by azimuth angle. Apartment plan types were divided into 2 types of Non-extension and extension of balcony. The designPH analysis data derived from the variant of the Heat-transfer Coefficient and SHGC, were put into PHPP(Passive House Planning Package) to analyze precisely the energy efficiency(Heating and Cooling Demands) of the building by azimuth angle. In addition, assuming the 'ㅁ' shape layout, energy efficiency performance and potential of PV Panel installation also were analyzed by floors and azimuth angle, reflecting the shading effects by surrounding buildings. As the results of the study, the effect of Heat Gain by SHGC was greater than Heat Loss due to the Heat-transfer Coefficient. So it is more effective to increase SHGC to satisfy the same Heating Demand, and increasing SHGC made possible to design windows with low Heat-transfer Coefficient. It was also revealed that the difference in annual Heating and Cooling Demands between the low, mid and high floor households is significantly high. In addition to it, the installation of PV Panel in the form of a shading canopy over the window reduces the Cooling Load while at the same time producing electricity, and also confirmed that absolute thermal energy efficiency could not be maximized without controlling the thermal bridge and ventilation problems as important heat loss factors.

The Building Energy Efficiency Rating Evaluation of Apartment depending on SC and Window area ratio (차폐계수와 창면적비에 따른 공동주택의 건물에너지효율등급 평가)

  • Jang, Cheol-Yong;Han, Hye-Sim;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.38-43
    • /
    • 2010
  • Enhancement of exterior's insulation performance like wall or window etc. is general way for building's energy efficient and thermal performance. But exterior's opening plan is important for minimizing the energy consumption and heat loss. In this paper, energy saving rate will be analyzed and compared considering the window area's rate and window's SC(Shading Coefficient) in a apartment with Building Energy Efficiency Rating System's evaluation tool. In the process of evaluation, energy saving rate is measured at each stage of the window area's rate from 20% to 60% every 10% term and the shading coefficient value from 1.0 to 0.6. As a result of this research, energy saving evaluation could not be measured exactly with existing evaluation tool. Accord this research, Building Energy Rating System's evaluation range is needed to be broaden for exact evaluation of energy saving rate.

A Study on the Energy Performance Evaluation of Window System with the Balcony Types of Apartments (공동주택 세대내 발코니 유형별 창호의 냉난방 에너지 성능분석 연구)

  • Yoon, Jong-Ho;An, Young-Sub;Kim, Byoung-Soo;Hwang, Sang-Kun
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.83-90
    • /
    • 2007
  • Apartment balcony has been indiscreetly remodeled since the government permitted remodeling on January 2006. But remodeled balcony has a few problems such as increase of heating energy, surface condensation and cold draft. The reason of thermal problem is mainly caused by the window system in a extended balcony. The purpose of this study is to analyze heating and cooling energy and propose the efficient window types for the extended balcony area of a apartment building. 4 types of window system which have fairly high U value in Korea are investigated as follows ; double clear glass, double low-e glass, triple clear glass and triple low-e glass. Comparing double clear 91ass with double low-e glass, triple clear glass and triple low-e glass, simulation results show that 10%, 7% and 15% saving of total primary energy can be expected.

A Study on the Improvement of Cross Ventilation Efficiency in a Tower Type Apartment in Summer Season (탑상형 아파트의 여름철 통풍성능 개선에 대한 연구)

  • Cho, Keun-Je;Chang, Hyun-Jae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.299-304
    • /
    • 2012
  • In terms of plane structure, tower-type apartments have several disadvantages compared to flat-type apartments in the aspect of ventilation rate. Such disadvantages may not produce good indoor cooling effects with natural ventilation inside the heated apartments in hot summer days, so they may cause high energy consumption by an increase in cooling load. The purpose of this study is to investigate ways for improving the indoor thermal environment of tower-type apartments in summer by conducting quantitative evaluations of the airflow distribution in households.

  • PDF

A Study on the Importance Analysis of Environmentally-Friendly Planning Factors Using Analytic Hierarchy Process (계층분석법을 이용한 환경친화 계획요소의 중요도 분석에 관한 연구)

  • 류지원;김정환;정응호
    • Journal of Environmental Science International
    • /
    • v.12 no.9
    • /
    • pp.897-903
    • /
    • 2003
  • This study focuses on importance level analysis of environmentally-friendly planning factors using Analytic Hierarchy Process(AMP). This study verify different planning principle makes comparison matrix by a relative comparison value, verified consistency after yield weight to analyze more objective importance for apartment complex estate environmentally-friendly planning factor. In order to decide importance of apartment complex estate environmentally-friendly planning factors multiplying weight of verified planning principle with weight of planning factors. The results are as follows; First, importance of preservation of green tract of lands, Preparation of Biotop, Tree planting of sites, Propriety of development density high except Circulation and practical use of water. Next, valued planning factors constituent appeared to Energy efficient building plan, Rubbish recycling, thermal utilization of solar energy, Artificial tree planting of buildings etc. importantly. Finally, plan constituent that importance is underrated most appeared by Practical use of building materials and equipment, Centralization of energy and resources, Preservation of corridor etc.

Assessment on Thermal Environment and Human Thermal Comfort in Residential Building Block through Field Measurement (실측을 통한 공동주택 단지 내에서의 온열환경 및 거주자 쾌적감 평가에 관한 연구)

  • Lim, Jong-Yeon;Hwang, Hyo-Keun;Song, Doo-Sam;Kim, Tae-Yeon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.311-317
    • /
    • 2008
  • As outdoor environment become worse due to concentration of population in large cities, the importance of environmental control strategies such as the arrangement of green space or water space and ventilation paths, has been increasingly recognized. However, most of the studies focus on the assessment on outdoor thermal environment, few studies focus on the interrelationship between thermal environment in residential block and human thermal comfort. The aims of this study is to develop the outdoor planning method to reduce the heating/cooling load in an apartment unit or entire block by the sustainable approaches in outdoor environmental design. In this paper, on the basis of the prior studies, the effect of the outdoor thermal environment on human thermal comfort will be analysed.

  • PDF

The Measurement of Airtightness Performance of Multi-Family Housing (다가구 및 다세대 원룸주택의 기밀성능 실측연구)

  • Baek, Nam-Choon;Han, Seung-Hyeon;Lee, Wang-Je;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.14 no.5
    • /
    • pp.117-121
    • /
    • 2014
  • Even though a study of airtightness performance of apartment and detached house have been done constantly, there are few of studies of multi-family housing which increasing every year. Therefore, this study analyzed airtightness performance of 20 households of one room in Daejeon to investigate airtightness performance standard. All experiments were performed under the same conditions except sealing windows to investigate airtightness performance without sealing windows (natural condition) and airtightness performance with sealing windows of studio apartment. As results, (1) average ACH50 without sealing windows was 19.2/h for pressurization, and 12.8/h for depressurization and (2) average ACH50 with sealing windows was 16.0/h for pressurization, and 10.7/h for depressurization and ACH50 in both condition, ACH50 under pressurization was about 50% higher than that under depressurization. Throughout this experiment, we can figure out that about 16% of air infiltration rate is occurred in windows, and the other 84% is occurred in rest of places such as Junction structure, socket and ventilating opening.

Case Study on the Energy Consumption Unit of District Apartments (지역난방 공동주택의 에너지원별 원단위 사례분석)

  • Lee, Wang-Je;Kang, Eun-Chul;Lee, Euy-Joon;Oh, Byung-Chil;Shin, U-Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.10
    • /
    • pp.474-480
    • /
    • 2014
  • This study investigated the total energy consumption and the energy consumption by type of 31 apartment complexes in Daejeon. The energy is supplied to the apartments from district heating, and can be divided into hot water, electricity, and gas. Hot water is used in for space heating and for domestic hot water (DHW), and electricity is used for plugs, cooling, ventilation, and public utilities (street lights, pumps, elevators, etc.). All gas supplied from district heating is used for cooking. As a result, the consumption unit of each energy source of independent dwelling areas was calculated to be $103.7kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$) for thermal energy, $48.0kWh/m^2{\cdot}a$ ($4,646kWh/H{\cdot}a$) for electricity, and $10.5kWh/m^2a$ ($1,015kWh/H{\cdot}a$) for gas, so the entire consumption was calculated to be $162.3kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$).

A Study on the Energy Performance Renovation for the Sustainable the Residential Houses (친환경주거단지를 위한 에너지 성능개선에 관한 연구)

  • Park, Jin-Chul;Kim, Ki-Hoon;Song, Gook-Sup;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.89-96
    • /
    • 2003
  • In planning a building retrofit, energy conservation, thermal comfort and economic benefits should be considered. In this study, retrofit effects of exterior insulating method on preventing condensation, saving energy were analyzed through the heat transfer simulation, energy simulation in the apartment house retrofitted by exterior insulating method cheaper than other retrofit methods. The results of this study show that the retrofit using exterior insulating method can prevent the condensation at the corner walls and save about 20% of annual heating load. The LCC analysis revealed to be effective to select a dryvit system for a building retrofit.

Overall Heat Transfer Coefficients and Thermal Performance Evaluation through Heat Flux Measurement at Nakseonjae in Changdeokgung (창덕궁 낙선재 외피 열류량 실측을 통한 열관류율 산정 및 열 성능 해석)

  • Kim, Min-Hwi;Kim, Jin-Hyo;Kwon, Oh-Hyun;Han, Wook;Jeong, Jae-Weon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.190-195
    • /
    • 2008
  • The objective of this research is to determine overall heat transfer coefficients (K-value) of exterior wall, floor, and roof of Nakseonjae, a Korean traditional residence via field measurement of transient heat flow and temperature difference across each envelope component. Heat flow sensors and T-type thermocouple were attached on the internal and the external surface of each building component, and real-time measurement data were collected for the three consecutive summer days. The K-values determined in this research showed good agreement with other results from open literature. Peak and annual thermal loads of the traditional residence estimated by a commercial energy simulation program were compared with those for a current apartment house. The traditional house showed lower annual cooling load than that of the current building. It may caused by the fact that the traditional building has less air-tight envelopes and no fenestration passing direct solar radiation into the space.

  • PDF