• 제목/요약/키워드: Solar Photovoltaic Energy

검색결과 1,274건 처리시간 0.026초

퍼지제어를 적용한 태양광 발전의 고효율 추적시스템 설계 (High efficiency tracking system design of photovoltaic using fuzzy control)

  • 고재섭;최정식;정철호;김도연;정병진;정동화
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.61-67
    • /
    • 2008
  • In this paper proposed the solar tracking system to use a fuzzy based on PC in order to increase an output of the PV array. The solar tracking system operated two DC motors driving by signal of photo sensor. The control of dual axes is not an easy task due to nonlinear dynamics and unavailability of the parameters. Recently, artificial intelligent control of the fuzzy control, neural-network and genetic algorithm etc. have been studied. The fuzzy control made a nonlinear dynamics to well perform and had a robust and highly efficient characteristic about a parameter variable as well as a nonlinear characteristic. Hence the fuzzy control was used to perform the tracking system after comparing with error values of setting-up. nonlinear altitude and azimuth. In this paper designed a fuzzy controller for improving output of PV array and evaluated comparison with efficient of conventional PI controller. The data which were obtained by experiment were able to show a validity of the proposed controller.

  • PDF

실물옵션을 활용한 RPS 실시에 따른 태양광 발전의 경제성 평가: 공급의무 발전사와 일반 발전사와의 비교 (Evaluating Economic Feasibility of Solar Power Generation Under the RPS System Using the Real Option Pricing Method: Comparison Between Regulated and Non-regulated Power Providers)

  • 김은만;김명수
    • 한국전기전자재료학회논문지
    • /
    • 제26권9호
    • /
    • pp.690-700
    • /
    • 2013
  • This study reviewed how the changes of the government policy on solar power generation projects affected the annual mandatory quotas of the regulated power providers under the RPS (renewable portfolio standard) system and analysed economic feasibility of the investment for meeting their quotas as compared to the case of non-regulated power providers. The analysis results showed that under the discount rate of 7.5%, which was used for the annual national electricity plans for the recent years, both the regulated and non-regulated power providers achieved economic feasibility under both the NPV (net present value) method and the real option pricing method. It was also shown that higher profitability was attained by non-regulated power providers than by their regulated counterparts, which can be attributable to the fact that regulated providers are required to out-source 50% of the total quota. The results of this study are considered to be useful for establishing a meaningful mid term or long term strategy for the future of solar power generation linked to the current RPS system.

천공상태에 따른 박막 BIPV 창호의 온도 및 발전특성 실측연구 (A Study on Optimum of Performance Objectives of Passive House with Load Reduction elements)

  • 김빛나;윤종호;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.171-176
    • /
    • 2012
  • This research on building Integrated Photovoltaic System replacing windows and doors with amorphous silicon thin film PV windows and doors installing same exact mount on Mock-up. The windows and doors should be installed in different angle and bearing so that we can analyse the amount of electricity from them. The objective of the research is to evaluate and investigate the relationship between factors(intensity of solar radiation, PV window surface temporature, incidence angle, and sky conditions) that affects performance of PV window and performance. The range and method of this research is to establish mornitoring system and analysis the date from the mornitoring system to evaluate the performance of PV windows that has thin film of solar battery. We should evaluate the insolation according to the position of PV window, output, and surface temperature according to months and seasons so that we can figure out the relationship between these. And we should investigate the relationship between performance and efficiency according to incidence angle and sky condition so that we can figure out the correlation between factors and performance.

  • PDF

3,6-Carbazole Incorporated into Polymer Effects on Solar Cells

  • Lee, Gang-Young;Cha, Hyojung;Park, Chan Eon;Park, Taiho
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.481.2-481.2
    • /
    • 2014
  • Bulk hetero junction (BHJ) polymer solar cell (PSCs) is one of the most promising fields as alternative energy source. Especially, the development of new p-type conjugated polymer is one of the main issues to get core technology. In this study, we investigated the chemical doping effects of incorporating 3,6-carbazole units into conjugated polymers based on 2,7-carbazole. We assessed the structural effects of this chemical doping by measuring the photovoltaic device performance of the copolymers with and without annealing. Note that the use of nanostructures in the bulk heterojunction layer could be a major obstacle to commercialization because nano-morphologies are frequently unstable at high temperatures. Therefore, the development of thermally stable polymer:fullerene blends with optimized PCEs is an important goal in this area of research. We studied the morphologies of the copolymers incorporating 3,6-carbazole units resulting from thermal annealing to investigate the effects of the difference between the T g values of the 2,7-carbazole unit and the 3,6-carbazole unit.

  • PDF

Synthesis and Application of New Ru(II) Complexes for Dye-Sensitized Nanocrystalline TiO2 Solar Cells

  • Seok, Won-K.;Gupta, A.K.;Roh, Seung-Jae;Lee, Won-Joo;Han, Sung-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권8호
    • /
    • pp.1311-1316
    • /
    • 2007
  • To develop photo-sensitizers for dye-sensitized solar cells (DSCs) used in harvesting sunlight and transferring solar energy into electricity, we synthesize novel Ru(II) polypyridyl dyes and describe their characterization. We also investigate the photo-electrochemical properties of DSCs using these sensitizers. New dyes contain chromophore unit of dafo (4,5-diazafluoren-9-one) or phen-dione (1,10-phenanthroline-5,6-dione) instead of the nonchromophoric donor unit of thiocyanato ligand in cis-[RuII(dcbpy)2(NCS)2] (dcbpy = 4,4'-dicarboxy- 2,2'-bipyridine) coded as N3 dye. For example, the photovoltaic data of DSCs using [RuII(dcbpy)2(dafo)](CN)2 as a sensitizer show 6.85 mA/cm2, 0.70 V, 0.58 and 2.82% in short-circuit current (Jsc ), open-circuit voltage (Voc), fill factor (FF) and power conversion efficiency (Eff), which can be compared with those of 7.90 mA/ cm2, 0.70 V, 0.53 and 3.03% for N3 dye. With the same chelating ligand directly bonded to the Ru metal in the complex, the CN ligand increases the Jsc value by double, compared to the SCN ligand. The extra binding ability in these new dyes makes them more resistant against ligand loss and photo-induced isomerization within octahedral geometry.

수직면 일사량을 고려한 초고층 건축물 적용 Unit형 BIPV 설계 방안에 관한 연구 (A Study on the Unit Type BIPV Design Method for Super-Tall Building Concentrating on the Solar Irradiance Incident on the Building Facades)

  • 류춘덕;서영석;오민석;김회서
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.370-375
    • /
    • 2011
  • BIPV시스템 분야는 다른 PV 적용 기술 분야에 비해 빠르게 성장하고 있으나 소형 건축물 위주로 적용되었으며, 초고층 건축물과 같이 수직적으로 높은 건축물의 외부환경조건에 대응하기 위한 BIPV의 적용 방안은 현재까지 연구되어지지 않았다. 국내의 경우 선진국에 비해 초고층 건축물에 대한 BIPV시스템 적용기술은 아직 초기 연구단계에 불과하다. 초고층 건축물의 고유의 특징을 고려하여 초고층 건축물 파사드에 입사하는 일사량의 분포가 균일하지 않을 것이라고 예측하고 실측을 진행하였으며, 실측 결과의 분석을 통하여 초고층 건축물에서의 BIPV시스템 최적 설계방안을 제시하였다. 결론적으로 본 연구에서는 초고층 건축물의 외벽에 입사하는 일사량을 고려한 Unit형 BIPV설계 방안을 제시하였으며, 특히, 측정된 일사량 데이터를 활용하여 초고층 건축물에 적합한 인버터의 선정의 대안을 제시하였다.

  • PDF

표면냉각시스템을 이용한 PV 모듈의 출력 향상 (Improving the power of PV module by a surface cooling system)

  • 이종환;이재웅;김동준;김대현
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.309-313
    • /
    • 2009
  • This study was conducted to improve the power of PV module using a surface cooling system. One of the unique characteristics of PV module is power drop as a module surface temperature increases due to the characteristics of crystalline silicon used in a solar cell. To overcome the output power reduction by temperature effect, module surface cooling using water circulation was performed. By cooling effect, module surface temperature drops maximally $20.3^{\circ}C$ predicting more than 10% power enhancement. Maximum deviation of voltage and current between a control and cooled module differed by 5.1V and 0.9A respectively. The maximum power enhancement by cooling system was 12.4% compared with a control module. In addition, cooling system can wash the module surface by water circulation so that extra power up of PV module can be achieved by removing particles on the surface which interfere solar radiation on the cells. Cooling system, besides, can reduce the maintenance cost and prevent accidents as a safety precaution while cleaning works. This system can be applied to the existing photovoltaic power generation facilities without any difficulties as well.

  • PDF

분산특성이 향상된 고효율 염료감응형 태양전지 (Enhanced Dispersion of High Performance Dye-sensitized Solar Cells)

  • 김은미;박경희;구할본;박복기
    • 한국전기전자재료학회논문지
    • /
    • 제22권6호
    • /
    • pp.501-505
    • /
    • 2009
  • $TiO_2$ nano-particle paste was prepared by ethyl cellulose, $\alpha$-terpineol and bis(2-ethylhexyl) phthalate (dioxcyl phthalate) for dye-sensitized solar cells (DSSCs). Dispersion and absorbance of $TiO_2$ photoanode films was controlled by adding different amount of ethyl cellulose and $\alpha$-terpineol. The morphology of prepared $TiO_2$ films was studied by field emission scanning electron microscopy (FE-SEM) and the optical properties of $TiO_2$ films were measured by UV/vis spectra. Photovoltaic-current density was observed to determine the electrochemical response of DSSCs. Energy conversion efficiency was obtained about 7.1% at ethyl cellulose and $\alpha$-terpineol at optimal mixed ratio (as ethyl cellulose: 0.1 g; $\alpha$-terpineol: 1.5 ml) under illumination with AM 1.5($100\;Wcm^{-2}$) simulated sunlight.

하이브리드 발전 시스템을 적용한 이동식 하우스 (Transportable House with Hybrid Power Generation System)

  • 박미정;주종율;김응곤
    • 한국전자통신학회논문지
    • /
    • 제18권1호
    • /
    • pp.205-212
    • /
    • 2023
  • 현대사회는 화석연료 등의 사용으로 기후변화로 인한 기상이변이 전 세계가 이례적인 피해가 속출하고, 코로나와 같은 전염병이 인간에게 더욱 생활의 질이 악화되고 있는 실정이다. 온실가스를 줄이고 신재생에너지 사용이 시급한 현실이다. 화석연료의 사용을 줄이고 신재생에너지 사용으로 지구환경 오염을 줄이고자 한다. 본 논문에서는 태양광을 이용해 지능형 CCTV 및 인터넷 WiFi, 냉난방 시스템을 통한 사계절 환경과 안전 및 통신 기능이 가능하고, 스마트폰 앱을 통한 태양광의 생산량과 소비량을 실시간으로 모니터링하여 최적화된 전력관리를 할 수 있는 시스템을 제안한다. 태양광 발전 시스템을 사용할 수 없는 한파, 태풍, 자연재해 등의 계통 정전과 같은 비상시 끊김 없는 디젤 발전을 지원하는 하이브리드 발전시스템을 제안한다.

Structural Response Analysis for Multi-Linked Floating Offshore Structure Based on Fluid-Structure Coupled Analysis

  • Kichan Sim;Kangsu Lee;Byoung Wan Kim
    • 한국해양공학회지
    • /
    • 제37권6호
    • /
    • pp.273-281
    • /
    • 2023
  • Recently, offshore structures for eco-friendly energy, such as wind and solar power, have been developed to address the problem of insufficient land space; in the case of energy generation, they are designed on a considerable scale. Therefore, the scalability of offshore structures is crucial. The Korea Research Institute of Ships & Ocean Engineering (KRISO) developed multi-linked floating offshore structures composed of floating bodies and connection beams for floating photovoltaic systems. Large-scale floating photovoltaic systems are mainly designed in a manner that expands through the connection between modules and demonstrates a difference in structural response with connection conditions. A fluid-structure coupled analysis was performed for the multi-linked floating offshore structures. First, the wave load acting on the multi-linked offshore floating structures was calculated through wave load analysis for various wave load conditions. The response amplitude operators (RAOs) for the motions and structural response of the unit structure were calculated by performing finite element analysis. The effects of connection conditions were analyzed through comparative studies of RAOs and the response's maximum magnitude and occurrence location. Hence, comparing the cases of a hinge connection affecting heave and pitch motions and a fixed connection, the maximum bending stress of the structure decreased by approximately 2.5 times, while the mooring tension increased by approximately 20%, confirmed to be the largest change in bending stress and mooring tension compared to fixed connection. Therefore, the change in structural response according to connection condition makes it possible to design a higher structural safety of the structural member through the hinge connection in the construction of a large-scale multi-linked floating offshore structure for large-scale photovoltaic systems in which some unit structures are connected. However, considering the tension of the mooring line increases, a safety evaluation of the mooring line must be performed.