• Title/Summary/Keyword: Solar Heating system

Search Result 492, Processing Time 0.022 seconds

A Study on the Design and Analysis of District Solar Heating and Cooling System with Preheating of Returning District Heating Water (지역난방수 환수 승온방식의 태양열 지역냉난방 시스템 분석)

  • Baek Nam-Choon;Shin U-Cheul;Lee Jin-Kook;Yoon Eung-Sang;Yoon Suk-Man
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.433-437
    • /
    • 2005
  • This study was carried out the design and analysis of solar thermal system with preheating of returning district heating water for the Chung-ju district heating and cooling system. Two different types of solar collectors are used for this system. TRNSYS simulation program was used for the analysis. As a results, the solar system efficiency is $35.8\%$ for the plate type and $45.1\%$ for the evacuated type solar collector in the case of $50^{\circ}C$ for the returning district heating water temperature. The returning district heating water temperature is on of the very important factors that is influence on the system efficiency. So the effect of the returning district heating water temperature on the system efficiency is analyzed in this study.

  • PDF

The Study of Thermal Performance on Solar Window (다기능 솔라윈도우의 열성능 연구)

  • Cho, YilSik;Kim, Janghoi;Yang, Yoonsub;Kim, ByoungSoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.65.2-65.2
    • /
    • 2010
  • The aim of this study was to analysis the Heating/cooling performance of Solar Window built in apartments. The solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system and allows more control due to the possibility to close the reflectors. However, there can be a conflict between the desire for on one hand daylight and view and on the other hand optimal energy conversion for the PV/Solar Collector system. The process of this study is as follows: 1) The Solar Window system is designed through the investigation of previous paper and work. 2)The simulation program(ESP-r, Therm5.0, Window6.0) was used in Heating/cooling performance analysis. The reference model of simulation was made up to analysis Heating/cooling performance on Solar Window. 3)Selected reference model(Floors:15, Area of Unit:$148.5m^2$) for heating energy analysis, Energy performance simulation with various variants, such as U-value of Solar Window system according to its position and angle. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down about 5%~11%.

  • PDF

Active Solar Heating System Design & Analysis Program (설비형 태양열시스템 설계분석 프로그램 개발)

  • Shin, U-Cheul;Baek, Nam-Choon
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.11-20
    • /
    • 2003
  • This study aims to develop the program for active solar heating system design & analysis. The program, named ASOLis, is consisted of three user's interface like as system input/output, library, and utilities and used TRNSYS as a calculation engine for the system analysis. ASOLis simplifies user's input data through the database and can design 37 different types of solar systems. Solar system is configurated by two separated parts "solar thermal collecting part" and "load supplying part". Due to the user-friendly layout, all design parameters can be changed quickly and easily for the influence on system efficiency. For the reliability, ASOLis compared with experimental result. As a result, ASOLis is expected to be used as a vital tool for the design and analysis of active solar heating system.

A study on the solar assisted heating system with refrigerant as working fluid (냉매를 작동유체로 사용하는 태양열 난방시스템에 관한 연구)

  • Kim, Ji-Young;Ko, Gawng-Soo;Park, Youn-Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.37-44
    • /
    • 2005
  • An experimental study was conducted to analyze performance of a heating system with variation of control logic of the system. The system uses a solar as heat source and composed with heat pump that uses R-22 as working fluid. The difference between the developed system and the commercially available heating system is working fluid. The solar assisted heating system which was widely distributed in the market uses water as a working fluid. It could be freezing in case of the temperature drops down under freezing point. The anti-freezing fluids such as methyl-alcohol or ethylene-glycol are mixed with the water to protect the freezing phenomena. However, the system developed in this study uses a refrigerant as a working fluid. It makes the system to run under zero degree temperature conditions. Another difference of the developed system compare with commercial available one is auxiliary heating method. The developed system has removed an auxiliary electric heater that has been used in conventional solar assisted heating system. Instead of the auxiliary electric heater, an air source heat exchanger which generally used as an evaporator of a heat pump was adapted as a backup heating device of the developed system. As results, an efficiency of the developed system is higher than a solar assisted heat pump with auxiliary electric heater. The merit of the developed system is on the performance increment when the system operates at a lower solar energy climate conditions. In case of the developed system operates at a normal condition, COP of the solar collector driven heat pump is higher than the air source heat exchanger driven heat pump's.

A Study on The Characteristics of Heat Pump Heating System Utilizing Heat Storage Tank (축열수조를 이용하는 열펌프식 난방의 특성에 관한 연구)

  • Kim H.K.;Lee G.Y.;Park M.S.;Hwang I.S.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.4
    • /
    • pp.392-405
    • /
    • 1987
  • A study of appling solar assisted heat pump heating system to Korean climatic charac-teritics has been undertaken through computer simulation using TRNSYS (A Transient System Simulation Program). It is insufficient for heating system composed of each of solar and heat pump system to supply heat met with heating load. So SAHP (Solar Assisted Heat Pump) heating systems which combined solar system with heat pump system are analized using the standard weather data of Korea. And SAHP heating systems are categorized into the series system in which the solar storage is used as the source for the heat pump, the parallel system in which ambient air is used as the source for the heat pump, and the dual source system in which the storage or ambient is used as the source depending on which source yields the lowest work input. These combined system are better than each of solar and heat pump heating system in view of thermal performance, and parallel system is most effective among these combined systems.

  • PDF

Analysis of Long-term Thermal Performance of Solar Thermal System Connected to District Heating System (지역난방 적용 태양열시스템의 장기 열성능 분석)

  • Baek, Nam-Choon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.167-173
    • /
    • 2007
  • This study analyzed by simulation using TRNSYS as well as by experiment on the solar district heating system installed for the first time for the district heating system in Bundang. Simulation analysis using TRNSYS focused on the thermal behavior and long-term thermal efficiency of solar system. Experiment carried out for the reliability of simulation system. This solar system where the circuits of two different collectors, flat plate and vacuum tube collector, are connected in series by a collector heat exchanger, and the collection characteristics of each circuit varies. Therefore, these differences must be considered for the system's control. This system uses variable flow rate control in order to obtain always setting temperature of hot water by solar system. Specifically, this is a system that heats returning district heating water (DHW) at approximately $60^{\circ}C$ using a solar collector without a storage tank, up to the setting temperature of approximately $85{\sim}95^{\circ}C$ To realize this, a flat plate collector and a vacuum tube collector are used as separate collector loops. The first heating is performed by a flat plate collector loop and the second by a vacuum tube collector loop. In a gross collector area basis, the mean system efficiency, for 4 years, of a flat plate collector is 33.4% and a vacuum tube collector is 41.2%. The yearly total collection energy is 2,342GJ and really collection energy per unit area ($m^2$) is 1.92GJ and 2.37GJ respectively for the flat plate vacuum tube collector. This result is very important on the share of each collector area in this type of solar district heating system.

A Study on the Field Test of the Solar Heating System with Parabolic Solar Collectors Integrated the Roof of a Residential Building (지붕대체형 집광집열기를 이용한 태양열 난방시스템의 동절기 성능 평가)

  • Kim, Yong-Ki;Lee, Tae-Won;Yoon, Kwang-Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.61-69
    • /
    • 2007
  • The final energy consumption in the building sector in Korea represents almost 20% of the total energy consumption. Besides, Space heating and hot water generation in Korea are based on fossil fuels, with a serious environmental impact. Despite the popularity of simple solar domestic hot water systems, active solar space heating remains, for various reasons, marginal. And thus, the aim of this paper is to demonstrate potentialities of solar assisted space heating systems, both technically and economically. From this study found that the solar heating system with CPC solar collectors integrated the roof of a single-story residential building shares $50{\sim}55%$ of the annual heating load.

A Computer Code for an Optimum Design of Solar Space and Domestic Hot Water Heating System (태양열주택 및 가정용 태양 온수시스템의 설계용 전산코드)

  • Im, D.J.;Chun, M.H.;Yoon, S.B.
    • Solar Energy
    • /
    • v.4 no.2
    • /
    • pp.37-42
    • /
    • 1984
  • A computer code for an optimum design of solar space and domestic hot water heating system has been developed. The f-chart method developed by S.A. Klein et al. has been incorporated in the present computer code. The main conclusions obtained from the present work may be summarized as follows: (1) In Seoul area, about 46% of the total heating load can be obtained from the solar collectors whose total surface area is about one-third of the total heating floor area. (2) In Pusan area, total area of solar collectors should be about half of the total heating floor area in order to obtain an equivalent solar fraction of Seoul. (3) In cheju area, on the other hand, only about 42% of the total heating floor area of solar collectors is needed to get the same solar fraction as in Seoul and Pusan. (4) In order to get the first 50% solar fraction, only about 10-14 collectors ($4'{\times}8'$ collectors) are required, whereas about 48 collectors are needed to obtain the solar fraction of 100%. That is, roughly 3.5-4.5 times greater number of collectors are required to increase the solar fraction from 50% to 100%. Therefore, it can be concluded that it is relatively inefficient and less economical to build a solar system whose solar fraction exceeds more than 50%.

  • PDF

The Development of Analysis Program of Solar Heating System for District Heating System (지역난방 태양열시스템 해석 프로그램 개발)

  • Back, Nam-Choon;Shin, U-Cheul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.190-195
    • /
    • 2008
  • This study aims to develop the thermal performance and economic analysis program of solar heating system applied to district heating systems. The program, named SOLAN-DHS, is consisted of four modules like as user's interface for system input/output, library, and utilities and a calculating engine. SOLAN-DHS simplifies user's input data through the database and can design 5 different types of solar systems. Due to the user-friendly layout, all design parameters can be changed quickly and easily for the influence on system efficiency. The reliability of SOLAN-DHS was finally verified by the experiments.

  • PDF

A Study on the Thermal Performance of a Solar House by a F-chart Method (F-chart 설계법(設計法)에 의한 태양열주택(太陽熱住宅)의 난방성능(暖房性能)에 관(關)한 연구(硏究))

  • Lee, Young-Soo;Seoh, Jeong-Ill;Yim, Jang-Soon
    • Solar Energy
    • /
    • v.2 no.2
    • /
    • pp.1-9
    • /
    • 1982
  • This paper presents a method. for estimating the useful output of solar heating sys-terns. Heating load calculations, climatic data and various conditions are used in this procedure to estimate the fraction of the monthly heating load supplied by solar energy for a particular system the design procedure presented in this paper referred to the f-chart method. The results of this study are as follows; 1) The collected energy is not rised lineary to collector area. 2) If the heating area has equivalent solar collector area, the solar energy utilization for space heating is over 90%. 3) Transmittance- absorptance product for radiation at normal incidence, (${\tau}{\alpha}$)/(${\tau}{\alpha}$)n, during most of the heating season is 0.92 for a two-cover collector. 4) Orientation of the collector has little effect on the annual performance of solar heating system within the $15^{\circ}$.

  • PDF