• Title/Summary/Keyword: Solar Heating Cooling

Search Result 284, Processing Time 0.038 seconds

A Study on the Operating Characteristics of Solar Collecting System in Solar Thermal/Geothermal Hybrid System with Facade Integrated Solar Collector (Facade 일체형 태양열 집열기를 갖는 태양열/지열 하이브리드 시스템의 태양열 집열시스템 작동특성 연구)

  • Baek, Nam-Choon;Lee, Jin-Kook;Yu, Chang-Kyun;Yoon, Eung-Sang;Yoon, Jong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.69-76
    • /
    • 2010
  • In this study, the solar thermal and geo-source heat pump(GSHP) hybrid system for heating and cooling of Zero Energy Solar House(ZESH) was analyzed by experiment. The GSHP in this hybrid system works like as aback-up device for solar thermal system. This hybrid system was designed and installed for Zero Energy Solar House (KIER ZeSH) in Korea Institute of Energy Research. The purpose of this study is to find out that this system is optimized and operated normally for the heating load of ZeSH. The analysis was conducted as followings ; - the thermal performance of facade integrated solar collector - the on/off characteristics of solar system and GSHP - the contribution of solar thermal system. - the performance of solar thermal and ground source heat pump system respectively. - the meet of thermal load (space and water heating load). This experimental study could be useful for the optimization of this system as well as its application in house. This hybrid system could be commercialized for the green home if it is developed to a package type.

An Analysis of Heating and Cooling Energy and Effect on Outdoor Air Cooling according to Building Type of Apartment Complex (공동주택 단지의 주동형식에 따른 냉난방 에너지 및 외기냉방 효과 분석)

  • Roh, Ji-Woong
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.31-38
    • /
    • 2014
  • This study makes three apartment building complex an object of analyzing representative building types and energy consumption rate of house holds, and effect of outdoor air cooling. Recently created apatrment complex is composed of very various types of building, plan, and orientation etc. But, it is difficult to remark conclusively that these various types of buildings are designed energy-effectively. Because architects are hard to find useful energy design guideline for decision making. By the preceding study, the present condition and problem about this subject is grasped, apartment building types were examined and representative types were extracted. In this study, energy simulation was conducted, and the effect to outdoor air cooling was analyzed about representative types of the subject apartment complex. It is expected that this analysed results will be basic data for the more integrated study. Research consequence can be summarized as follow: 1) Besides solar gain, household layout of building, orientation, and plan etc. effects compositively on energy consumption rate. 2) The effect of ourdoor air cooling in building of tower type can be improved by arranging households appropriately.

A study on analysis of energy consumption of Detached house by U-value and SCs of windows and Building Orientation (창의 종류 및 차폐계수 변화와 건물 향에 따른 단독주택의 에너지요구량 분석)

  • Jeong, Su-Hui;Park, Hyo-Sun;Lee, Byung-Yun
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.96-103
    • /
    • 2012
  • Annual energy consumption in detached houses are affected mainly by thermal performance of envelope. In particular the performance of glasses are critical due to global wanning and climatic change. Therefore, this research analyzes annual consumption of cooling and heating energy with various combination of U-value, shading coefficient and building orientation. The simulation results shows that shading coefficient of glazing contributes to the changes of proportion of heating and cooling energy demand and the optimized shading coefficient for minimizing energy consumption varies with buildings orientation.

Building Energy Demand Models for Offices in Korea (업무용 건물의 에너지 부하 모델)

  • Park, Hwa-Choon;Chung, Mo
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.1-7
    • /
    • 2009
  • Energy demands for offices in Korea are surveyed and analyzed to generate communicational models for simulations. Daily energy loads of 13 office buildings scattered in the 6 largest cities in the country are surveyed and analyzed based on energy consumption log sheets. Detailed hourly loads that are frequently required when a detailed operation simulation is performed are measured using remote data acquisition processes for 3 offices. The complete load demand models of electricity, cooling, heating and hot water are established by combining the daily and hourly patterns based on the statistical behavior of the hourly patterns.

A Study on Heating and Cooling Degree-Days Calculation Methods with NCDC Data (NCDC데이터를 활용한 냉난방도일 산정 및 계산방법에 관한 연구)

  • Seo, Dong-Hyun;Song, Yujin
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.77-84
    • /
    • 2013
  • Degree-day method is very simple but essential index to estimate heating and cooling energy demand in buildings. It has been neglected, however, for the simplicity so it is difficult to find any DB for south Korean cities. Even meteorological department of S. Korea doesn't report the data officially. In this study, current methods that are being used in many countries are investigated and used to calculate degree-days of 35 south Korean cities with 30 years(1981~2010) historical data. The calculation result indicates that the error among 4 major methods are dependent on how daily or hourly temperature are treated in the calculation and how balance point temperature is defined. The errors of the methods are no larger than 6% relative to hourly degree-day method.

A Case Study on the Design Variables Evaluation of Green Roof System effecting on Building Energy Conservation (건물 에너지 소비량에 영향을 미치는 옥상녹화시스템 설계변수 평가에 관한 사례 연구)

  • Choi, Jeong-Min
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.41-48
    • /
    • 2015
  • This study is to find out the major design variables of Green roof system effecting on the building energy consumption. Therefore, in three categories of green roof system, namely, foliage layer, soil layer and irrigation, 10 design variables are selected and simulated with one-story case building. Simulation is carried out with Design Builder and EnergyPlus. Finally, it was found out the effects of major variables affecting on the building heating and cooling energy and how they are affecting on the heating and cooling seasons respectively.

Experimental Study on the Cooling and Heating Operation Characteristics of a Sea Water Source Heat Pump (해수열원 히트펌프 시스템의 냉난방 운전 특성에 관한 실증 연구)

  • Kim, Ji-Young;Baik, Young-Jin;Chang, Ki-Chang;Ra, Ho-Sang
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.544-549
    • /
    • 2009
  • The purpose of this study is to investigate the field Operation Characteristics of a sea water heat source cascade heat pump system and system applicable to Building. Cascade heat pump system is composed R410A compressor, R134a compressor, EEV, cascade heat exchanger, Plate heat exchanger etc. Building area is $890m^2$ and has five floors above ground. R410A is used for a low-stage working fluid while R134a is for a high-stage. The system could runs at dual mode. One is mode of general R410A refrigeration cycle in summer and the other is cascade cycle. In order to gain a high temperature supply water in winter season, the system is designed to perform a cascade cycle. The filed test results show that the sea water heat source heat pump system exhibits a COP of about 5.5 in cooling mode along with a heating COP of about 4.0 in 1-stage heating mode. Cascade 2-stage heat pump system is enough to supply $60^{\circ}C$ water and heating COP is about 3.0

  • PDF

A Case Study on Thermal Performance for Transparent Glazing Space Considering Solar Radiation in Summer (여름철 일사를 고려한 투명 투과체 공간의 열환경 특성에 관한 사례연구)

  • Ryu, Young-Hee;Seo, Hye-Soo;Lee, Min-Jung;Nam, Ji-yeon;Song, Mi-Na;Chun, Chung-Yoon
    • KIEAE Journal
    • /
    • v.3 no.1
    • /
    • pp.31-36
    • /
    • 2003
  • Recently, buildings with transparent glazing on exterior walls have increased. The transparent glazing on exterior walls gives an impression of opening through introducing external environment's elements to inside of the building, and has various merits and so on, but has defects in controling indoor environments. Especially, the excess of solar radiation in summer increases cooling load causing discomforts to occupants providing radiant environment with high temperature. Cooling load mainly depends on electricity comparing to heating load and intents to centralize specific time. So it is necessary to work out a countermeasure. In this study, showed P building with transparent glazing on exterior walls as a case, investigated indoor thermal performance, numerical analysis of P building in summer through comparing dry-sauna which is represented as radiant environment with high temperature. In the results of this study, transparent glazing space has radiant environment with high temperature such as dry-sauna because of the excess of solar radiation. Accordingly countermeasures are considered in building planning. As concrete methods, there are adiabatic effects using double glazing, use of sunscreen, blind, ventilation facilitation using natural draft, decrease of surface temperature through evaporation cooling and cooling coils.

The Simulation Approach for the Optimal Design of Small Scale District Heating and Cooling System (소규모 지역냉난방 시스템 최적설계 시뮬레이션)

  • Im, Yong-Hoon;Park, Hwa-Choon;Cho, Soo;Jang, Cheol-Yong;Chung, Mo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.147-154
    • /
    • 2008
  • A simulation program is developed for the optimal design of small scale district heating and cooling system. Main features for the simulation program are the reliability and the easiness for the optimal design of the DHC(District Heating and Cooling) systems. In order for implementing those features, the operational characteristics according to the prime movers is modeled based on the materials of efficiency as a function of operational load. The unit energy load model is also developed extensively for several building types, of which the corresponding district consist, such as apartment complex, hotel, hospital, buildings for business and commercial use respectively. The specific features and the overall procedure of the simulation are described in brief in this paper. The results of the simulation for several test cases will be presented in subsequent study.

  • PDF