• 제목/요약/키워드: Solar Heat Flux

검색결과 138건 처리시간 0.022초

반사경 배치와 흡수기 형상에 따른 접시형 고온 태양열 시스템 성능비교 (Performance Comparison of Dish Solar Collector With Mirror Arrays & Receiver Shapes)

  • 마대성;김용;서태범
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.29-38
    • /
    • 2007
  • In order to analyze the performance comparison of dish solar collector with mirror arrays and receiver shapes, the radiative heat flux distribution inside the cavity receiver is numerically investigated. The solar irradiation reflected by dish solar collector is traced using the Monte-Carlo method. Five different dish solar collectors and three different cavity receivers are considered. A parabolic-shaped perfect mirror of which diameter is 1.5 m is considered as a reference dish solar collector and four different arrays of twelve identical parabolic-shaped mirror facets of which diameter are 0.4 m are used. Their reflecting areas, which are $1.5\;m^2$, are the same. Three different cavity receiver shapes are dome, conical, and cylindrical. In addition, the radiative properties of the concentrating surfaces can vary the thermal performance of the cavity receiver so that variation of the surface reflectivity of each mirror is considered. Based on the calculation, the design information of dish solar collector for producing the electric power can be obtained. The results show that the dome type has the best performance in receiver shapes and the 2AND4 INLINE has the best performance in mirror arrays except perfect mirror.

熱다이오식 밀폐공간의 熱傳達 特性에 關한 實驗的 硏究 (An Experimental Study on Heat Transfer Characteristics of Thermal Diode Type Enclosure Cavity)

  • 장영근;김석현
    • 설비공학논문집
    • /
    • 제12권12호
    • /
    • pp.1073-1080
    • /
    • 2000
  • Thermal diode is a device which allows heat to be transferred in one direction by convection due to density difference of fluid ,and blocks heat flow in the opposite direction. It is simple in construction and low in cost. And so, it is used as heat collection system of solar energy. In order to acquire a basic design data, thermal diode heat collection system has been studied experimentally for flux Rayleigh numbers from $2\times10^8\;to\;8\times10^8$. The heat transfer rate of this system is shown 10~47% higher than that of other earlier research results. He correlation obtained in this study is Nu=0.0037(Ra^*)^{0.429}(d^*)^{0.05}\frac{(Lr)}{H}^{0.415}$.

  • PDF

다수의 장애물을 가진 유동채널에서의 강제 대류에 관한 연구 (Forced Convection in a Flow Channel with Multiple Obstacles)

  • 남평우;조성환
    • 태양에너지
    • /
    • 제9권1호
    • /
    • pp.62-69
    • /
    • 1989
  • This analysis is to investigate the influence of inflow angle when cooling air flows into PC (Printed Circuit) board channels. Flow between PC board channels with heat generating blocks is assumed laminar, incompressible, two-dimensional. Geometric parameters (block spacing (S), block height (H), block width (W) and channel height (L)) are held fixed. Inflow angle variations are $-10^{\circ},\;0^{\circ},\;10^{\circ}$, where uniform heat flux per unit axial length Q (W/m) from heated block surfaces is generated. The governing equations for velocity and temperature are solved by SIMPLE (Semi-Implicit Method Pressure for Linked Equation) algorithm. Nusselt number on each block surfaces is analyzed after a numerical calculation result. The result shows that the assumption on parallel inflow (inflow angle to channel, $0^{\circ}$) to PC board channels can be used without large error even when inflow' angle is varied.

  • PDF

지붕 증발냉각시스템의 열성능 해석 (Analysis of Thermal Performance in Roof Evaporative Cooling System)

  • 신우철
    • 한국태양에너지학회 논문집
    • /
    • 제21권3호
    • /
    • pp.9-18
    • /
    • 2001
  • This paper reports on an theoretical study of heat transfer from evaporative cooling system by the flow of recirculated water over the roof. In this system tile water is distributed at the top of the pitched roof, collected at the bottom by a gutter and recirculated by a pump. To analysis the system, the energy balance equations are developed and solved using a finite difference method. The calculation results show a good agreement with the measured ones obtained from our experiment. Based on the results, it was seen that the roof-evaporative cooling system reduced the heat flux significantly compared with the conventional roof structure even in the hot-humid summer climate of Korea.

  • PDF

상부채널을 갖는 사각공간에서 열유속 변화에 따른 공기대류의 속도와 온도 가시화 (Velocity and Temperature Visualization of Air Convection in Differently Heated Rectangular Cavity with Upper Channel)

  • 이철재
    • 태양에너지
    • /
    • 제20권4호
    • /
    • pp.53-60
    • /
    • 2000
  • An experimental study was carried out in a cavity with upper channel and square heat surface by visualization equipment with Mach-Zehnder interferometer and laser apparatus. The visualization system consists of 2-dimensional sheet light by Argon-Ion Laser with cylindrical lens and flow picture recording system. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system(CACTUS'2000). Obtained result showed various flow patterns. Severe unsteady flow fluctuation within the cavity are remarkable and sheared mixing layer phenomena are also found at the region where inlet flow is collided with the counter-clockwise rotating main primary vortex. Photographs of Mach-Zehnder are also compared in terms of constant heat flux.

  • PDF

An Experimental Study on Heat Transfer Characteristics of a Thermal Diode Type Enclosure with a Guide Vane

  • Kim, Suk-Hyun;Jang, Young-Keun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권4호
    • /
    • pp.10-16
    • /
    • 2001
  • An experimental study for free convective heat transfer in a thermal diode type enclosure is presented. The thermal diode is a device which allows heat to be transferred in one direction by convection due to density difference of the fluid, and consists of a rectangular-paralle-logrammic enclosure with a guide vane. It is used as heat collection system of solar energy due to its simple construction and low cost. Experimental parameters were guide vane thickness, the inclination angles of the parallelogrammic enclosure, and the lengths of the rectangular enclosure part. The parameter range of the flux Rayleigh numbers was $2.4\times{10}^8$~$9.8\times{10}^8$. The heat transfer rate of this system was shown 10~47% higher than that of other earlier research results without the guide vane. The correlation for fixed $\phi=60^\circ$ was obtained, Nu=0.0037(Ra^*)^{0.429}(d^*)^ {0.050}(Lr/H)^{0.0415}$.

  • PDF

강제순환 방식의 공기가열식 태양열 집열기의 성능분석에 관한 수치해석 연구 (A Numerical Study on the Performance Analysis of a Solar Air Heating System with Forced Circulation Method)

  • 박형수;김철호
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.122-126
    • /
    • 2017
  • 태양열 에너지를 이용하여 단순한 형태의 공기가열식 집열기를 이용하여 공기를 가열하고 이를 활용하여 생활공간의 난방문제를 해결하기 위한 장치를 개발하는데 목적을 두고 진행되고 있다. 현 시점에서 연구는 모델로 개발한 공기가열식 태양열에너지 집열기의 크기 변화에 따른 가용한 에너지의 량을 이론적으로 산출해 보고 이를 통해 개발 시스템의 가능성을 판단하고자 한다. 본 연구에서는 공기가열식 태양열 집열기의 공기가열성능을 판단하기 위하여, 특정 크기의 태양열 집열기에 일정한 일사량을 투하하였을 때, 모델 집열기 내부에서의 열전달 특성변화와 이를 통해 생산되는 공기의 온도($^{\circ}C$)와 생산량(kg/h)을, 유한체적법(Finite Volume Method)을 적용한 범용 열유동해석(CFD) 프로그램인 영국 CHAM사의 PHOENICS(1)를 이용하여, 분석한 결과를 구하였다. 분석한 결과에서 알 수 있듯이 집열기의 크기가 ($1.2m{\times}1.1m{\times}0.19m$)의 집열기에서 알루미늄으로 제작하는 내경 0.1m의 공기 가열관을 이용하여 가열할 수 있는 공기의 온도는 약 $40.5^{\circ}C$이며 이때 생산되는 공기의 생산량은 약 $161m^3/h$으로 산출되었다. 본 모델장치는 충분히 태양의 열에너지를 이용하여 실내공간의 온도를 인간이 활동하기에 적합한 활동의 환경을 유지하는데 활용할 수 있다고 판단된다.

보일러 내부 고온가스에 노출된 전열 튜브에서의 열유속 평가 방법 (Estimation method of heat flux at tube bank exposed to high temperature flue gas in large scale coal fired boilers)

  • 정재진;송정일
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.259-264
    • /
    • 2009
  • Most of the fossil power plants firing lower grade coals are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. The poor combustion conditions are directly related to the gas flow deviation in upper furnace and convection tube-bank but a less reported issue related to in large-scale oppose wall fired boilers. In order to develop a on-line combustion monitoring system and suggest an alternative heat flux estimation method at tube bank, which is very useful information for boiler design tool and blower optimizing system, field test was conducted at operating power boiler. During the field test the exhaust gases' temperature and tube metal temperature were monitored by using a spatially distributed sensors grid which located in the boiler's high temperature vestibule region. At these locations. the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. Test results showed that the flue gas monitoring method is more proper than metal temperature distribution monitoring for real time combustion monitoring because tube metal temp. distribution monitoring method is related to so many variables such as flue gas, internal flow unbalance, spray etc., Heat flux estimation at the tube bank with flue gas temp. and metal temp. data can be alternative method when tube drilling type sensor can't able to use.

  • PDF

달 표면온도 예측을 위한 집중계 해석방법과 하부 열유속 모델의 적용 (Lumped System Analysis on the Lunar Surface Temperature Using the Bottom Conductive Heat Flux Model)

  • 김택영
    • 한국항공우주학회지
    • /
    • 제47권1호
    • /
    • pp.66-74
    • /
    • 2019
  • 달 표면 전체에 걸쳐 열물성치를 확보하는 대신 단위 면적당 열질량을 이용하여 달 표면온도를 정확히 예측할 수 있는 개선된 집중계(Lumped System Model, LSM) 해석방법을 제시하였다. 최근에 발표된 연구에 기초하여 표토층 최상단의 단위 면적당 열 질량이 균일하다고 가정하고, 하부면 전도열유속 방정식을 이론적인 근거 하에 도입함으로써 DLRE 측정온도와 상당한 정도 잘 일치하는 달 표면의 온도지도를 구하였다. LSM 온도예측은 태양복사가 약한 황혼, 새벽 및 고위도 지역을 제외하면 DLRE 측정과 잘 일치하며, 이러한 지역에서의 온도 불일치는 하부 전도열유속 모델의 한계에 기인한다. 표면 지형과 열물성치가 매우 불균일한 지역에서 나타나는 비정상온도 영역을 제외하고 LSM 분석으로 생성된 달 표면 온도지도는 DLRE 측정 결과와 유사하다.

V 형 rib과 dimple로 구성된 SAH 덕트에서의 총괄 열성능에 대한 수치적 연구 (Numerical study on overall thermal performance in SAH duct with compound roughness of V-shaped ribs and dimples)

  • 아닐 쿠마르;김만회
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.43-55
    • /
    • 2015
  • This paper presents the thermal hydraulic performance of a three dimensional rib-roughened solar air heater (SAH) duct with the one principal wall subjected to uniform heat flux. The SAH duct has aspect ratio of 12.0 and the Reynolds number ranges from 2000 to 12000. The roughness has relative rib height of 0.045, ratio of dimple depth to print diameter of 0.5 and rib pitch ratio of 8.0. The flow attack angle is varied from $35^{\circ}$ to $70^{\circ}$. Various turbulent flow models are used for the heat transfer and fluid flow analysis and their results are compared with the experimental results for smooth surfaces. The computational fluid dynamics (CFD) results based on the renormalization k-epsilon model are in better outcomes compared with the experimental data. This model is used to calculate heat transfer and fluid flow in SAH duct with the compound roughness of V-shaped ribs and dimples. The overall thermal performance based on equal pumping power is found to be the highest (2.18) for flow attack angle of $55^{\circ}$. The thermo-hydraulic performance for V-pattern shaped ribs combined with dimple ribs is higher than that for dimple rib shape and V-pattern rib shape air duct.