• Title/Summary/Keyword: Solar Fraction

Search Result 147, Processing Time 0.023 seconds

Study on Efficiency of Flat-Plate Solar Collector Using Nanofluids (나노유체를 이용한 평판형 태양열 집열기의 효율에 관한 연구)

  • Lee, Seung-Hyun;Jang, Seok Pil
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.9
    • /
    • pp.799-805
    • /
    • 2013
  • An analytical study is conducted to assess the efficiency of a flat-plate solar collector using nanofluids. The nondimensionalized 2D heat diffusion equation is solved by assuming a wavelength-independent extinction coefficient and intensity to obtain the analytical solution of the temperature distribution in the flat-plate solar collector. The dimensionless temperature distribution is investigated as functions of the volume fraction of the nanofluids, magnitude of heat loss, and collector's depth based on the analytical solution when using water-based single-walled carbon nanohorn (SWCNH) nanofluids as a working fluid. Finally, the efficiency of the flat-plate solar collector using the nanofluids is predicted and compared with that of the conventional solar collector. The results indicate that the efficiency of the nanofluid solar collector is better than that of the conventional solar collector under specific geometrical conditions.

Heteroface p-$Al_{x}Ga_{1-x}As/p-GaAs/n-GaAs/n^{+}$-GaAs Solar Cell Grown by MOCVD (MOCVD를 이용한 Heteroface p-$Al_{x}Ga_{1-x}As/p-GaAs/n-GaAs/n^{+}$-GaAs 태양전지의 개발)

  • 창기근;임성규
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.1
    • /
    • pp.30-39
    • /
    • 1991
  • The influence of physical parameters (Al mole fraction, thickness, doping concentration) in the window and emitter on the efficiency characteristics of heteroface p-$Al_{x}Ga_{1-x}As/p-GaAs/n-GaAs/n^{+}$-GaAs solar cell is investigated. The maximum efficiency theoretically calculated in this device is obtained when a thickness of the window is in a range of (400-1000))$\AA$and a thickness/doping concentration of the emitter is in a range of (0.5-0.8)$\mu$m/(1-7)${\times}10^{17}cm^{-3}$, respectively. Also is the efficiency improved according to the increase of Al mole fraction in the indirect gap window(0.41${\le}x{\le}1.0$). The optimum designed heteroface cell with an area of 0.165cm$^2$fabricated using MOCVD exhibits an active area conversion efficiency of 17%, having a short circuit current density of 21.2mA/cm\ulcorner an open circuit voltage of 0.94V, and a fill factor of 0.75 under ELH-100mW/cm$^2$illumination.

  • PDF

An Empirical Study on the Thermal Performance and Dynamic Behavior of Wall Integrated Thermosiphon Solar Water Heater (벽체일체형 자연순환 태양열온수기의 동적거동과 열성능에 관한 실증연구)

  • Baek, Nam-Choon;Kim, Sung-Bum;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.25-35
    • /
    • 2016
  • In this study, the evaluation of the dynamic behavior and thermal performance of the "Façade integrated Natural circulation Solar Water Heating System" installed in the residential house was carried out. Experimental tests were performed during the all year around in the rural houses of $166m^2$ in size. Facade integrated solar collector of $5m^2$ were installed on the south-facing. Electrical heater of 1 kW capacity as an auxiliary heater was installed at the upper part of the heat storage tank. The analyzing results are as follows. (1) Monthly average solar fraction was 51 to 87% and yearly average value is 64%. (2) Hot water supply temperature in December which has the lowest solar altitude is 37 to $76^{\circ}C$. The highest working fluid temperature of solar collector in this period was below $84^{\circ}C$. The temperature difference of working fluid between the collector inlet and outlet has been shown to be around 9 to $26^{\circ}C$. (3) Overheating which is one of the biggest problems during summer did not appear at all, but rather had hot water supply temperature is rather low as $30{\sim}47^{\circ}C$ in summer than winter, which is supplied by a small solar load. The solar collecting temperature has been shown to maintain below $55^{\circ}C$. (5) The thermal performance of Facade integrated solar collector can be increase due to the reduction of heat loss to the back of the collector wall integration of the collector is reduced. As a conclusion, Facade integrated natural circulation type Solar Water Heating System is a well-functioning without any pumps or controllers, and it was found that the disadvantages of conventional solar water heaters, hot water or hot water system can be greatly improved.

Mechanochemically Synthesized Cu2Zn(Sn,Ge)S4 Nanocrystals and Their Application to Solar Cells (기계화학적 방법으로 합성한 Cu2Zn(Sn,Ge)S4 나노결정과 이를 이용하여 제조한 태양전지)

  • Park, Bo-In;Lee, Seung Yong;Lee, Doh-Kwon
    • Current Photovoltaic Research
    • /
    • v.4 no.3
    • /
    • pp.114-118
    • /
    • 2016
  • $Cu_{1.8}Zn_{1.2}(Sn_{1-x}Ge_x)S_4$ (CZTGeS) nanocrystals were mechanochemically synthesized from elemental precursor powders without using any organic solvents and any additives. The composition of CZTGeS nanocrystals were systematically varied with different Ge mole fraction (x) from 0.1 to 0.9. The XRD, Raman spectroscopy, high-resolution TEM, and diffuse reflectance studies show that the as-synthesized CZTGeS nanocrystals exhibited consistent changes in various structural and optical properties as a function of x, such as lattice parameters, wave numbers for $A_1$ Raman vibration mode, interplanar distances (d-spacing), and optical bandgap energies. The bandgap energy of the synthesized CZTGeS nanocrystals gradually increases from 1.40 to 1.61 eV with increasing x from 0.1 to 0.9, demonstrating that Ge-doping is useful means to tune the bandgap of mechanochemically synthesized nanocrystals-based kesterite thin-film solar cells. The preliminary solar cell performance is presented with an efficiency of 3.66%.

Conceptual Design Strategy of Renewable Energy Application for Building Certification and Mandatory System (신재생에너지설비 건물설치 의무화 및 인증제를 고려한 용량설계 방안)

  • Lee, Kyoung-Ho;Lee, Dong-Won;Kown, Hyeok-Min;Lee, Chang-Jun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.99-104
    • /
    • 2011
  • This paper describes a design strategy at conceptual design stage using RETScreen software tool for building application of renewable energy resources. Currently, government and public buildings are required to adopt renewable energy systems with a minimum requirement for the amount of renewable energy supply. Meanwhile, there is a certificate program for private office buildings to enhance propagation of renewable energy systems. When considering application of renewable energy systems to a building, it is worthwhile developing a method to determine optimal design sizes of renewable energy systems. In the paper, a design strategy is introduced with a couple of case studies to determine optimal capacities of each renewable energy system in a building and suggest to use the method to evaluate the system for the building certificate program and the mandatory renewable target program. Objective functions considered in the study are initial system cost and reduction of CO2 emissions from the system. In the optimization study, it is assumed that solar thermal collectors are installed to satisfy solar fraction of 60%. Other renewable energy systems such as ground-source heat pump, solar PV and non-renewable systems such as electric chiller and gas-fired boiler are sized using an optimal sizing method with RETScreen suggested the authors previously.

  • PDF

High frequency and high power PECVD를 이용한 thin film solar cell용 microcrystalline Si 증착

  • Lee, Seung-Mu;Kim, Yeong-Seok;Han, Mun-Hyeong;Byeon, Dong-Jin
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.52.2-52.2
    • /
    • 2009
  • Si 박막형 solar cell은 Si 결정형 solar cell대비 cost 및 대면적화 측면에서 장점을 가지고 있다. 그러나 amorphous Si의 경우 light soacking에 의한 열화 문제가 있고, microcrystalline Si의 경우 요구되는 효율 확보를 위하여 $1.5{\mu}m$ 이상 두께가 필요하며, 증착율이 $5{\AA}/sec$.이하인 단점이 있다. 본 연구에서는 high deposition rate로 microcrystalline Si를 증착하기 위하여 high frequency, high power PECVD를 이용하였으며, RF power, 증착온도, H2/SiH4 ratio의 3인자를 3수준으로 변화시킨 완전요인배치 실험을 실시하였다. 실험결과 증착율은 $8.0{\AA}/sec.{\sim}52.8{\AA}/sec$ 범위, crystalline fraction은 0%~83.3% 범위의 결과를 얻었으며, 결정이 형성된 조건에서는 XRD분석결과 $2\theta=28.5$ 및 47.5에서 Si (111), (220) peak을 확인할 수 있었다. Surface Profilometer 를 이용한 surface roughness의 경우 $6.3{\AA}\sim32.4{\AA}$ 범위의 결과를 얻었으며, crystalline Portion이 높을수록 surface roughness가 증가함을 알 수 있었다.

  • PDF

Enhancement of Stratification for Solar Water Storage Tank with Spiral Jacket and Coil(Part 1:Verification Experiment) (나선유로에 의한 태양열 축열조 성층화 촉진(제1보 실증실험))

  • Kwon, Jae-Wook;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.336-342
    • /
    • 2012
  • Large-scale active solar heat systems are generally using heat exchanger between collector and storage tank loops to prevent damage by freezing. It is difficult to maintain stratification in a storage tank in the system owing to greater flow rate enhancing heat transfer. In the previous study, we introduced a spiral-jacketed storage tank and obtained good results to keep system performance of general level without better stratification. We added a scroll-shaped heat exchanger coil on the upper part in the spiral-jacketed storage tank. As a result of the experiment, it was verified that degree of stratification of the new type storage tank is higher than that of the previous one with a possibility of better collector efficiency and solar fraction.

A Study on Thermally Stratied Hot Water Storage Tank in A Solar Heating System (태양열 난방 시스템에 적용되는 축열조의 성층화에 관한 연구)

  • Hong, Hi-Ki;Kim, Hyo-Kyung
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.1
    • /
    • pp.87-96
    • /
    • 1986
  • An experiment on the devices that enchance the stratification of storage tanks in a solar heat ins system has been carried out. The benefits of thermal stratification in sensible heat storage are to increase the system performance such as the collector efficiency or the fraction of the total load supplied by solar energy. Using the diffuser and the distributor as the stratification enchancement device, the expeliments were perfomed in the different condition of diameter and material of the distributor. As a result of experiments, there exists the diameter of distributor in which the stratification is made maximum under certain design and operation condition. Also it was identified that the kind of distributor material influenced the degree of stratification. Comparing the experimental result to the computational results calculated under the same conditions, the node number N(stratification index) was determined. The results of computer simulation that was performed about the actual solar heating system in Seoul for 24 hours show the relative advantage of stratified over well-mixed storage and the significant improvements in system performance.

  • PDF

Advanced Forecasting Approach to Improve Uncertainty of Solar Irradiance Associated with Aerosol Direct Effects

  • Kim, Dong Hyeok;Yoo, Jung Woo;Lee, Hwa Woon;Park, Soon Young;Kim, Hyun Goo
    • Journal of Environmental Science International
    • /
    • v.26 no.10
    • /
    • pp.1167-1180
    • /
    • 2017
  • Numerical Weather Prediction (NWP) models such as the Weather Research and Forecasting (WRF) model are essential for forecasting one-day-ahead solar irradiance. In order to evaluate the performance of the WRF in forecasting solar irradiance over the Korean Peninsula, we compared WRF prediction data from 2008 to 2010 corresponding to weather observation data (OBS) from the Korean Meteorological Administration (KMA). The WRF model showed poor performance at polluted regions such as Seoul and Suwon where the relative Root Mean Square Error (rRMSE) is over 30%. Predictions by the WRF model alone had a large amount of potential error because of the lack of actual aerosol radiative feedbacks. For the purpose of reducing this error induced by atmospheric particles, i.e., aerosols, the WRF model was coupled with the Community Multiscale Air Quality (CMAQ) model. The coupled system makes it possible to estimate the radiative feedbacks of aerosols on the solar irradiance. As a result, the solar irradiance estimated by the coupled system showed a strong dependence on both the aerosol spatial distributions and the associated optical properties. In the NF (No Feedback) case, which refers to the WRF-only stimulated system without aerosol feedbacks, the GHI was overestimated by $50-200W\;m^{-2}$ compared with OBS derived values at each site. In the YF (Yes Feedback) case, in contrast, which refers to the WRF-CMAQ two-way coupled system, the rRMSE was significantly improved by 3.1-3.7% at Suwon and Seoul where the Particulate Matter (PM) concentrations, specifically, those related to the $PM_{10}$ size fraction, were over $100{\mu}g\;m^{-3}$. Thus, the coupled system showed promise for acquiring more accurate solar irradiance forecasts.

Columnar Aerosol Properties at Yongin According to Transport Paths of Back Trajectories (역궤적 이동경로별 용인지역의 컬럼에어로졸 특성)

  • Park, Jisoo;Choi, Yongjoo;Ghim, Young Sung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.2
    • /
    • pp.97-107
    • /
    • 2017
  • Columnar aerosol properties retrieved from solar radiation were investigated at the Yongin (YGN) SKYNET site over seven years from October 2008 to October 2015. Hourly averages were calculated when the data were available, and back trajectories were calculated to examine the effects of regional transport. Data recovery rate was low at 6.6%, primarily because solar radiation was measured only under daytime clear-sky conditions. Mean values of the fine-mode volume fraction (FMVF) as well as its seasonal variation were similar to those of $PM_{2.5}/PM_{10}$ although the coarse-mode fraction of column aerosols tended to be slightly larger. The values of single scattering albedo (SSA) and FMVF were lower in spring due to the effects of mineral dust, and higher in summer due to secondarily-formed inorganic ions. Back trajectories were grouped into five clusters according to the directions of transport paths. Aerosol loading was highest for Cluster 2 from the northwest, but SSA and FMVF were not particularly high or low because aerosols were composed of various materials with different properties. Aerosol loading was lowest for Cluster 5 from the Pacific Ocean passing through the south end of Japan, whose SSA and FMVF were highest as secondarily-formed inorganic ions were mixed.