• Title/Summary/Keyword: Solar Cycle

Search Result 380, Processing Time 0.025 seconds

A Study on the Heat-Storage/-Release Characteristics of a Regenerative Heat Exchanger Utilizing the Reversible Thermochemical Reaction of $Ca(OH)_2/CaO$ ($Ca(OH)_2/CaO$ 계의 가역 열화학 반응열을 이용한 축열식 열교환기의 축열 및 방열특성에 관한 연구)

  • Lee, Soo-Kag;Kim, Hong-Jea;Lee, Jin-Kook
    • Solar Energy
    • /
    • v.9 no.2
    • /
    • pp.22-30
    • /
    • 1989
  • Since the energy storage method by means of the thermochemical reaction has no heat loss by separating the reactants under the storage period, it is remarked as one of promising means particularly for long-term heat storage. In this study, the heat-storage/-release characteristics of the reversible chemical reaction cycle, $Ca(OH)_2/CaO$, is numerically analysed by a mathematical modelling. As a result, the effectiveness of the heat exchanger by the chemical heat storage method is considerably higher than that by the sensible heat storage method. It is found that the major parameters, which determines the effectiveness of the heat exchanger, are the mass flow rate and inlet temperature of fluid, the residence time, etc.. The heat-storage/-release period can be controlled by changing the operation conditions. It is expected that the results obtained here will supply useful informations in designing a regenerative heat exchanger utilizing the thermochemical reaction.

  • PDF

A Study on the Energy Performance Renovation for the Sustainable the Residential Houses (친환경주거단지를 위한 에너지 성능개선에 관한 연구)

  • Park, Jin-Chul;Kim, Ki-Hoon;Song, Gook-Sup;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.89-96
    • /
    • 2003
  • In planning a building retrofit, energy conservation, thermal comfort and economic benefits should be considered. In this study, retrofit effects of exterior insulating method on preventing condensation, saving energy were analyzed through the heat transfer simulation, energy simulation in the apartment house retrofitted by exterior insulating method cheaper than other retrofit methods. The results of this study show that the retrofit using exterior insulating method can prevent the condensation at the corner walls and save about 20% of annual heating load. The LCC analysis revealed to be effective to select a dryvit system for a building retrofit.

A Study on Comparison between Korea Green Building Rating System and LEED 2009 in Office Building (국내 친환경건축물 인증제도와 LEED의 평가항목 비교 연구-업무시설을 중심으로)

  • Lee, Hyun-Woo;Choi, Chang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.78-86
    • /
    • 2011
  • Recently due to the crisis of environment and resources, construction industry that effects a lot on nature than any other industries is essentially required to consider environment element through the life cycle. With the increase in the demand for sustainable and environmentally-friendly development, Green Building Certification System came into force in 2002. Lots of advanced countries and Korea have been running green building certification system. But many people of Korea is getting interested in LEED. We spend too much money to get a LEED Certification. So we need to develop our own green building certification that fits our environment. In this study, we are going to compare GBCC with LEED to develop our Green Building Rating System.

Optical and Electrical Properties of $Ti_xSi_{1-x}O_y$ Films

  • Lim, Jung-Wook;Yun, Sun-Jin;Kim, Je-Ha
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.675-679
    • /
    • 2009
  • $Ti_xSi_{1-x}O_y$ (TSO) thin films are fabricated using plasma-enhanced atomic layer deposition. The Ti content in the TSO films is controlled by adjusting the sub-cycle ratio of $TiO_2$ and $SiO_2$. The refractive indices of $SiO_2$ and $TiO_2$ are 1.4 and 2.4, respectively. Hence, tailoring of the refractivity indices from 1.4 to 2.4 is feasible. The controllability of the refractive index and film thickness enables application of an antireflection coating layer to TSO films for use as a thin film solar cell. The TSO coating layer on an Si wafer dramatically reduces reflectivity compared to a bare Si wafer. In the measurement of the current-voltage characteristics, a nonlinear coefficient of 13.6 is obtained in the TSO films.

Statistical studies of trough at middle latitudes observed by DMSP F15

  • Park, Sarah;Kil, Hyosub;Kim, Khan-Hyuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.126.1-126.1
    • /
    • 2012
  • The middle-latitude ionization trough, the plasma density depletion in the subauroral region, has been extensively studied since its discovery in the 1960s. Our knowledge of the variability of the trough is mostly based on the observations in the northern hemisphere. Recently, the COSMIC observations enabled the investigation of the trough in both hemispheres at all local time. However, the investigation was limited to the period of the low solar activity. In this study, we investigate the variability of the trough location and morphology with local time, solar cycle, magnetic activity, and interplanetary magnetic field. For this purpose, we analyze the DMSP F15 data acquired during 2000-2010.

  • PDF

Characteristics Evaluation of Absorption Cycles using the Waste Heat (배열 이용형 흡수식 사이클 특성평가)

  • Yoon, J.I.;Kwon, O.K.;Moon, C.G.
    • Solar Energy
    • /
    • v.18 no.4
    • /
    • pp.23-32
    • /
    • 1998
  • Fuel cells supply electric power and heat at work, and their exhaust gas is comparatively clear. So they are in the limelight as one of the co-generation systems which behave friendly with the environment. Fuel cells discharge both steam and hot water. Accordingly, if we combine absorption heat pump driven by waste heat with fuel cells, we can construct an advanced energy conserving system. The purpose of this study is the objective for evaluating the possibilities of effectively utilizing waste heat of fuel cells as a heat source for the single and double effect absorption systems. Simulation studies on single and double effect absorption have been performed for water/lithium-bromide pair. The effectiveness of introducing a waste heat source of fuel cells is demonstrated. The result of this study showed that total efficiency was about 85% at rated operation and about 75% at 75% load operation. Absorption cycle moved to more strong concentration when fuel cell operated at 75% load.

  • PDF

A Study on the Economic Analysis of Cooling-Heating System Using Ground Source Heat in a public library (공공도서관에 지열시스템 적용시 경제성에 관한 연구)

  • Choi, Chang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.1
    • /
    • pp.56-66
    • /
    • 2012
  • This study evaluated the economic benefits by comparing Cooling-Heating System with the existing system in the public library. The building's annual energy consumption was measured by adding the figures of the absorber chillers, the air conditioners and heaters in the building. The total amount of annual energy consumption was 143.51RT in air-conditioning and 83.66RT in heating. So, We made the capacity of geothermal heat pumps three 50RTs in order to check up this system. In order to estimate each construction and equipment cost and to evaluate economical efficiency, LCC(Life Cycle Cost) method was used and the service life of the building was sixty years. The result of analysis was that the geothermal cooling-heating system was more efficient than the existing system in public library.

Development of Solar Lighting Controller and Monitoring System (태양광 가로등 제어장치 및 모니터링 시스템 개발)

  • Kim, Tae-Yeop;Jung, Maeng-Hwa;Goh, Kwon-Sung;Yoo, Kwang-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.331-333
    • /
    • 2001
  • The flooded type battery is used for solar lighting system. Because the characteristic of flooded type battery is the short life time, the maintenance cost is high. So the using floe fed type battery in this system is inappropriate. The valve regulated lead acid batter(VRLA) is the maintenance free and cycle service purpose. This paper presents the development of control system and monitoring system to applied VRLA battery for maintenance free and long life time in system.

  • PDF

Development of Simulation Program for Multi-Air conditioner (멀티에어컨의 성능해석 프로그램 개발)

  • Jeong, B.Y.;Koh, J.Y.;Park, B.D.;Yim, C.S.
    • Solar Energy
    • /
    • v.20 no.1
    • /
    • pp.63-72
    • /
    • 2000
  • In this study, theoretical simulation method for the steady state characteristics of a refrigeration cycle which consists of one condenser and multi-evaporator (Multi-air conditioner) is presented. The simulation was performed for a typical multi-air conditioning system consisted one outdoor unit with air-cooled condenser, compressor, linear electric expansion valve and bypass circuit and connected three-evaporators (three indoor units). The simulation results are good agreement with those of experiments within 5 $\sim$ 10% at the given system operation conditions which are condensing pressure, evaporating pressure, sub-cooled degree of condenser, superheated degree, discharge temperature of compressor and pulse of linear electric expansion valve.

  • PDF

Analysis of Power Generation Characteristics according to the MPPT Algorithm Period (MPPT 알고리즘의 주기에 따른 발전 영향 분석)

  • Min, Joonki;Choi, Wonseok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.4
    • /
    • pp.233-237
    • /
    • 2018
  • In this paper, we compared power generation characteristics of two MPPT algorithms, P & O and InC, applied to grid-connected solar inverters. The MPPT detects the voltage and current of the solar module string and transfers the power to the DC link. Since the grid is connected by the power conversion circuit, the grid connection control and the MPPT control influence each other. The power generation characteristics were analyzed by Psim simulation according to the MPPT cycle in the weak grid conditions.