• Title/Summary/Keyword: Soil-resistivity

Search Result 260, Processing Time 0.022 seconds

Frequency-Dependent Resistivity and Relative Dielectric Constant of Soil on Water Content (수분함유량에 따른 토양의 저항률 및 비유전율의 주파수의존성)

  • Choi, Jong-Hyuk;Cha, Eung-Suk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.98-104
    • /
    • 2010
  • In order to evaluate the performance of a grounding system against lightning or fault currents including high frequency components, the grounding impedance should be considered rather than the steady state ground resistance. To evaluate the ground impedance, the frequency dependence of resistivity and relative dielectric constant of the soil have to be analyzed. This paper deals with the frequency dependence of the resistivity and relative dielectric constant of three types of soil on water content. As a result, the resistivity of soil is getting lower with increasing of water content. It is nearly independent of the frequency in the range less than 1[MHz], and is decreased over the frequency range above 1[MHz]. On the other hand, the relative dielectric constant is rapidly decreased with the frequency in the range less than 1[MHz], but it is nearly independent on the frequency over the range of 1[MHz]. It was found from the experiments that the frequency-dependant resistivity and relative dielectric constant of soil should be considered when designing the grounding systems for protection from lightning or switching surges.

A Study on the Applicaton of Electrical Resistivity Survey in the Contaminated Soil and Groundwater Site (토양 및 지하수 오염지역에 대한 전기비저항탐사의 적용성 연구)

  • Chae, Seungheon;Lee, Sangeun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.525-539
    • /
    • 2020
  • A site containing buried solid waste and treated water and oil storage containers from a leather manufacturing plant was studied through soil and groundwater pollution and electrical resistivity surveys with the aim of identifying areas polluted by leachate generated by landfilling with leather waste and leakage wastewater. It was found that TPH and Zn exceeded environmental standards for soil pollution and, for leachate and groundwater, Cr(VI) concentrations exceeded standard levels for groundwater quality. An electrical resistivity survey was used to elucidate soil and groundwater pollution characteristics and diffusion pathways. Ten survey lines were set up with an electrode spacing of 5 m in a dipole-dipole array. The hydraulic characteristics of soil determined by groundwater contamination surveys matched well the low-resistivity-anomaly zones. Electrical resistivity surveys of areas containing contaminated soil and groundwater that have irregular strata due to waste reclamation are thus useful in highlighting vertical and horizontal pollutant diffusion pathways and in monitoring contaminated and potentially contaminated areas.

Study of oversampling algorithms for soil classifications by field velocity resistivity probe

  • Lee, Jong-Sub;Park, Junghee;Kim, Jongchan;Yoon, Hyung-Koo
    • Geomechanics and Engineering
    • /
    • v.30 no.3
    • /
    • pp.247-258
    • /
    • 2022
  • A field velocity resistivity probe (FVRP) can measure compressional waves, shear waves and electrical resistivity in boreholes. The objective of this study is to perform the soil classification through a machine learning technique through elastic wave velocity and electrical resistivity measured by FVRP. Field and laboratory tests are performed, and the measured values are used as input variables to classify silt sand, sand, silty clay, and clay-sand mixture layers. The accuracy of k-nearest neighbors (KNN), naive Bayes (NB), random forest (RF), and support vector machine (SVM), selected to perform classification and optimize the hyperparameters, is evaluated. The accuracies are calculated as 0.76, 0.91, 0.94, and 0.88 for KNN, NB, RF, and SVM algorithms, respectively. To increase the amount of data at each soil layer, the synthetic minority oversampling technique (SMOTE) and conditional tabular generative adversarial network (CTGAN) are applied to overcome imbalance in the dataset. The CTGAN provides improved accuracy in the KNN, NB, RF and SVM algorithms. The results demonstrate that the measured values by FVRP can classify soil layers through three kinds of data with machine learning algorithms.

Variation of the Electrical Resistivity with ion Components of Pore Water in the Sand (사질토 간극수의 이온 성분들에 따른 전기비저항값의 변화)

  • Yu, Chan;Yoon, Chun-Gyeong;Lee, Young-Nam;Lee, Yong-Gil
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.185-196
    • /
    • 1999
  • A laboratory experiment was performed to examine the relationship between resistivity and ionic components in the pore water of a sand by using soil resistivity test box and STING-Rl. The resistivity measurement was performed with the concentration changes of ionic components. Also, the resistivity change was evaluated for multiple components. The results showed that the resistivity of Arsenic was less than other heavy metals. In the case of complex components, resistivity ranges depended on the resistivity of components existed in the pore water.

  • PDF

The Optimization Grounding Analysis for Soil Resistivity (대지저항률에 따른 최적화 접지 해석)

  • Jung, Yeon-Ha;Jang, Tae-Jun;Kwak, Hee-Ro;Roh, Young-Su;Shong, Kil-Mok
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.241-245
    • /
    • 2004
  • The electric safety tends to be more important according to electric facilities's increase and its use in these days. This paper analyzes soil resistivity of two areas in the country using CDEGS(Current Distribution, Electromagnetic Interference, Grounding and Soil Structure, Canada). We designed rod and mesh grounding system and made a comparative study of ground resistance, GPR(Main Electrode Potential Rin), step voltage and touch voltage. Then we could analyz only the safety but also economical efficiency in elocution of grounding. As a result of simulation, ground resistance, GPR(Main Electrode Potential Rise), step voltage and touch voltage became higher in proportion to soil resistivity. Therefore we expect to estimate the propriety of grounding system design through accumulation and analysis of data in consideration of characteristics of soil.

  • PDF

Investigation of Coring Grounding Construction by Equivalent Radius Concept (등가반경개념에 의한 코어링 접지공사의 고찰)

  • 김세호;김일환;양문길
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.103-110
    • /
    • 2003
  • The grounding system is necessary to provide means to dissipate electric currents into the earth without exceeding any operating and equipment limits. The ground is composed of various soils and the resistivity of the soil depends on many parameters. It depends on the type of soil and varies with distance as well as with depth. Especially, soil resistivity of volcanic area such as Jeju is ve교 high and it is difficult to acquire necessary grounding resistivity. This paper introduces the efficient grounding construction using coring technique for proper grounding resistance in high resistivity area. Because it is difficult to measure the accurate resistivity of soils, their resistivities are estimated using measured value of ground resistance and equivalent radius method. Estimated resistivities are used for grounding resistance in scheduled construction region.

Electrical Characteristics against Frequency and Concentration of Contaminated Soils by Mercury and Arsenic (수은과 비소로 오염된 시료의 측정주파수와 농도 변화에 따른 전기적 특성)

  • Son, Young-Hwan;Bong, Tae-Ho;Chang, Pyoung-Wuck
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.6
    • /
    • pp.15-24
    • /
    • 2008
  • In general, ground pollution can be classified with soil pollution and underground water pollution. And ground pollution contaminates the land with garbage dumps and other harmful waste products as heavy metals that can also eventually enter our water supply. This study was conducted to define a characteristics of the electrical resistivity and the permittivity of weathered soil that was contaminated with heavy metals as Mercury and Arsenic. It is not easy whether contamination of soil as subsurface contamination is decided or not and at an early stage especially do that. Therefore the electrical resistivity and the permittivity were used to make up for this defects. These methods are more economical and more effective than the existing methods. And variation of the electrical resistivity and the permittivity values were found against the change of concentration of Mercury and Arsenic aqueous solutions and measuring frequency. These analyzed results indicate that the electrical resistivity and the permittivity tend to decrease against increasing measuring frequency. The electrical resistivity and the permittivity are also found to show the function of frequency.

A Study on the Applicability of Resistivity Cone for Contaminant Investigation in Farm Land (농경지 오염탐사를 위한 비저항콘의 적용성에 관한 연구)

  • Yu, Chan;Yoon, Chun-Gyeong
    • Journal of Korean Society of Rural Planning
    • /
    • v.5 no.1 s.9
    • /
    • pp.45-55
    • /
    • 1999
  • The applicability of resistivity cone for contaminant investigation in farm land was examined in laboratory and in-situ. To verify the resistivity variations in sand with contaminants, laboratory experiment used soil resistivity test box was performed. Heavy metal and others ions were appeared steep variations in low concentration. Pilot test results were the same as laboratory test results. In the in-situ test used resistivity cone, resistivities of waste landfill layer were low than the common soil layers and resistivities had been difference with concentration of contaminant components. Therefore contaminant investigation in farm land using resistivity cone was expected very effective.

  • PDF

Development and Verification of Resistivity Seismic Dilatometer(RSDMT) System for Characterizing Soft Soil Site (연약지반조사를 위한 전기비저항 탄성파 Flat DMT 장비의 개발 및 검증)

  • Bang, Eun-Seok;Kim, Young-Sang;Sung, Nak-Hun;Park, Sam-Gyu;Seo, Dong-Nam;Lee, Sei-Hyun;Kim, Jung-Ho;Kim, Dong-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.623-634
    • /
    • 2007
  • The aim of this research is development and verification of resistivity seismic dilatometer (RSDMT) system. The resistivity module for obtaining resistivity-depth plot and seismic module for obtaining wave velocity-depth plot are attached to the conventional flat dilatometer testing equipment. To enhance reliability and repeatability of seismic part in RSDMT, automatic testing system including automatic surface source, PC based data acquisition system and operating program were developed. To obtain real resistivity value of soil, geometric factor for the array of electrodes in RSDMT was derived empirically. The verification studies for the developed RSDMT system were performed at the southeast side of Korea where soil improvement work is planned. SPT, CPT, geophysical subsurface imaging techniques and some laboratory tests were performed for the comparisons. As one penetration of RSDMT, various soil parameters could be obtained. The results of field test showed good repeatability and reliability in every part. From these studies, developed RSDMT system was checked and the effectiveness of this system was verified in light of proper evaluation of geotechnical characteristics of soft soil.

  • PDF

STUDYING SOIL THERMAL RESISTIVITY ABOUT CABLE LAYING OF PIPE DUCTING, DIRECT BURYING (관로 및 직매 포설에 대한 토양열저항의 검토)

  • Kim, Y.;Kwon, B.I.;Kwon, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.174-176
    • /
    • 1993
  • Laying up homogeneous power cable in the earth. we sure that one of the most effectest fact is the rising of thermal resistivity. Today, system designing of in and outdoor project, calculating current carrying capacity totally depend on standard of JCS-168D and IEC-287 to applicate. Specially, the formula of calculating soil thermal resistivity is what is based on KENELLY,s is usually used. In this report, Let's study the formula of soil thermal resistivity which was born in the idea of KENELLY.

  • PDF