• Title/Summary/Keyword: Soft-Hard

Search Result 1,356, Processing Time 0.034 seconds

The Oral Disease of Inpatient with the Systemic Disease (전신질환으로 입원한 환자의 구강내과 진료실태)

  • Yoo, Sang-Hoon;Jung, Sung-Hee;Auh, Q-Schick;Hong, Jung-Pyo;Chun, Yang-Hyun
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.1
    • /
    • pp.15-26
    • /
    • 2008
  • Purpose : To investigate the actual conditions of diagnosis and treatment of oral medicine inpatient with systemic disease. Methods : A total of 110 subjects, inpatient due to systemic disease for diagnosis and treatment of oral disease was requested to answer the medical history and dental treatment record. Results : Systemic disease is composed of Non-insulin-dependent diabetes mellitus 26%, Cerebral infarction 25.2%, Intracerebral hemorrhage, Polyarthrosis, Coxarthrosis 4.7%, Nerve root and plexus disorders, Hypertensive heart and renal diseases, Ankylosing spondylitis 2.4%. Chief complain of oral disease is composed of toothache 28.6%, routine check 23%, tooth mobility 8.7%, hypersensitivity 7.1%, periodontal bleeding 6.4%. Oral disease is composed of Gingivitis and periodontal diseases 28.9%, Dental caries 17.1%, Diseases of pulp and periapical tissues 15.1%, Diseases of salivary glands 10.5%, Other diseases of hard tissues of teeth 8.6%, Within Normal Limit 5.3%. Treatment of oral disease is composed of periodontal treatment 17.95%, rejection of treatment 16.67%, medication for halitosis & dry mouth 13.46%, extraction 12.18%, prosthetic treatment 8.97%. Chief complain in oral medicine is composed of oral soft tissue problem 6.4%, craniomandibular disorders 5.6%, halitosis 4%, total 16%. Conclusion : These findings indicate that inpatient due to the systemic disease is significantly correlated to the oral disease. The patients of oral disease interrelationship between inpatient and outpatient of systemic disease should be validated by future research.

The experimental study of early loading on the Miniplate in the beagle dog (성견의 하악골에 식립된 Miniplate에 가한 조기 부하의 영향에 관한 실험적 연구)

  • Chung, Yong-Koo;Lee, Young-Jun;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.307-317
    • /
    • 2003
  • Conventional osseointegrated titanium implants have many limitations; large size, limited location for placement of the implant, severity of the surgery, discomfort of initial healing, difficulty of oral hygiene and uncontrollable force direction. Recently titanium miniscrew and miniplate have been used for an alternative to conventional dental implant. But in relation to miniplate, miniscrew has disadvantages in that more potential inflammation, light orthodontic force application and limited orthodontic application. This study was conducted to evaluate the effectiveness of miniplate by observing the reactions of peri-implant tissues to early orthodontic and orthopedic loading of titanium miniplate. In four adult beagle dogs 10 miniplates were inserted into the alveolar bone using 20 osseointegrated titanium screws. 4 miniplates were placed in two dogs(dogA, B) and 6 miniplates in two dogs(dogC, D). In dogA, B miniplates were loaded with 200gm of force immediately after placement for 15 weeks. In dogc, D, miniplates were loaded with 400gm of force immediately after placement for 8 weeks. Miniplates of dogA were removed, dogA was healed for 4 weeks, and the area which was removed of miniscrew was examined. Following an observation period, the miniplates including miniscrews and the surrounding bone of dogB and dogC, D were removed, respectively. Undecalcified section along the long axis of miniscrews were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features there was direct contact between bone and miniscrew in all groups except one, dogC control group. The loaded miniscrew demonstrated only a slight increase of the osseous proximaty when compared with unloaded miniscrew 2. There was no significant difference of the osseointegration of Peri-miniscrew surface between dogB and dogC, D. But dogB showed slightly more increased bone apposition than dogC, D 3. The gingiva overlapping the miniplate and miniscrew showed no inflammatory sign in clinical and histological aspects. 4. The impaled hard and soft tissues at the area which was removed of miniscrews showed good healing without inflammatory reaction. 5. The mobility showed slight increase in un-loaded miniplate but that was insignificant. Based on the results of this study, miniplate(C-tube) can be used as a firm osseous orthodontic and orthopedic anchorage unit immediately after insertion.

Viscosity and Wettability of Carboxymethylcellulose(CMC) solutions and Artificial Saliva (Carboxymethylcellulose(CMC) 용액과 인공 타액의 점도와 습윤성)

  • Park, Moon-Soo;Kim, Young-Jun
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 2007
  • Destruction of oral soft and hard tissues and resulting problems seriously affect the life quality of xerostomic patients. Although artificial saliva is the only regimen for xerostomic patients with totally abolished salivary glands, currently available artificial salivas give restricted satisfaction to patients. The purpose of this study was to contribute to the development of ideal artificial saliva through comparing viscosity and wettability between CMC solutions and human saliva. Commercially-available CMC is dissolved in simulated salivary buffer (SSB) and distilled deionized water (DDW). Various properties of human whole saliva, human glandular saliva, and a CMC-based saliva substitutes known as Salivart and Moi-Stir were compared with those of CMC solutions. Viscosity was measured with a cone-and-plate digital viscometer at six different shear rates, while wettability on acrylic resin and Co-Cr alloy was determined by the contact angle. The obtained results were as follows: 1. The viscosity of CMC solutions was proportional to CMC concentration, with 0.5% CMC solution displaying similar viscosity to stimulated whole saliva. Where as a decrease in contact angle was found with increasing CMC concentration. 2. The viscosity of human saliva was found to be inversely proportional to shear rate, a non-Newtonian (pseudoplastic) trait of biological fluids. The mean viscosity values at various shear rates increased as follows: stimulated parotid saliva, stimulated whole saliva, unstimulated whole saliva, stimulated submandibular-sublingual saliva. 3. Contact angles of human saliva on the tested solid phases were inversely correlated with viscosity, namely decreasing in the order stimulated parotid saliva, stimulated whole saliva, unstimulated whole saliva, stimulated submandibular-sublingual saliva. 4. Boiled CMC dissolved in SSB (CMC-SSB) had a lower viscosity than CMC-SSB (P < 0.01 at shear rate of $90s^{-1}$). 5. For human saliva, contact angles on acrylic resin were significantly lower than those on Co-Cr alloy (P < 0.01). 6. Comparing CMC solutions with human saliva, the contact angles between acrylic resin and human saliva solutions were significantly lower than those between acrylic resin and CMC solutions, including Salivart and Moi-Stir (P <0.01). The effectiveness of CMC solutions in terms of their rheological properties was objectively confirmed, indicating a vital role for CMC in the development of effective salivary substitutes.

Changes in Subjective Symptom, Tear Film Stabilization and Blinking Rates when Wearing RGP Lenses with Different Polishing Conditions for Certain Period of Time (연마상태가 다른 RGP렌즈의 일정기간 착용 시 렌즈착용자의 자각적 증상, 눈물막 안정 및 순목횟수 변화)

  • Park, Mijung;Kim, Hyo Gyum;Bae, Jun Seob;Park, Jung Ju;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • Purpose: The present study was conducted to investigate the effect of the physical properties of RGP lens induced by lens polishing on the actual wearer's subjective comfort, the tear film break-up time and the blinking rate as a follow-up study that revealed the relationship between the lens physical properties during lens manufacturing and lens wearer's factors. Methods: RGP lenses made from the three different polishing conditions (25, 50 and 100 seconds) were applied on 28 eyes of 17 subjects, aged 20 to 29 years, without any known disease and surgical history in the eyes. While the subjects were asked to wear the RGP lenses longer than a week, the questionnaire for the comfortability was administered everyday. Subjective and objective tear break-up time and blinking rate of the wearers were further measured. Results: The wearer's subjective comfortability showed some difference in the type of discomfort and satisfaction score according to the polishing status when wearing RGP lenses made from different polishing conditions longer than a week, and a bigger difference in satisfaction score induced by polishing condition was especially shown in experienced RGP lens wearer rather than un-experienced wearer. In the case of RGP lens wearer compared with the ones without the wearing experience, as the wearing time increased subjective and objective tear break-up time were increased and the blinking rate was decreased. However, subjective and objective tear break-up time were tended to decrease with even longer wearing time when wearing the RGP lens made from the polishment for 100 seconds. Conclusions: These results confirmed that the optimization of physical properties of the lens may not give the same effect on the wearer's subjective and objective symptoms and other factors when actual wearing. From the results, it can suggest that the success rate of RGP lens wear may be changed by physiological factors such as the stabilization of wearer's tear film, comfortability and lens wearing experience when wearing RGP lens based on 'The manufacturing standard for soft contact lens/hard contact lens' provided by Korea Food and Drug Administration.

The Origination and Changes of Street Fashion (스트리트 패션의 발생과 변천)

  • Jung, Kyong-Hee;Yoo, Tai-Soon
    • Journal of Fashion Business
    • /
    • v.1 no.1
    • /
    • pp.71-83
    • /
    • 1997
  • The purpose of this study is to analyze the present fashion phenomenon by considering the types of street fashion, the center of avant-grade modern fashion, that shows the origination background and special feature concretely. The times was defined through the 1980's from World War II that street style originated, so the range of study was the 1990's when the street style was influenced by that of the past and was revived. The ways of study were to analyze the records of ideology, art and music connected with the street style from World War II to the present when it has risen. The summary of result is as follows. (1) In the 1940's, Zooties was the jet of desire suppressed by African-Americans that couldn't receive favors socially and economically and Hipsters pursued reformative bebop that made up of soft Jazz. In the 1950's, Modernists were running after Cool Jazz to the minimum. In the 1970's, Funk appered in the sexual desire and erotic strength, and was surfaced from Negro Getto. In the 1980's B-boys & Flygirls showed the street style by the scribble art of slum in the New York. As mentioned above, In the 1990's, Acid Jazz influenced by the Jazz of Negro has been the fashion added to the tradition of musical form that come from eclecticism of Jazz tended Neo-Jazz. (2) In the 1940's, Western style dreamed the country life because of rapid urbanization. In the 1950's, Beat obtained the feeling of liberation from the dissolute life and activity. In the 1960's, Psychedelics showed the freedom affected by the Pop-art and Op-art, and Hippies pursued the true individuality as 'love & peace' life style and the return to nature. In the 1990's, Grunge look influenced by the above has been fashion that shows the practical use of second-hand clothing or patchwork contrary to elitism. (3) In the 1940's, Caribbean style appered in the typical textile color with the center of West Indies. In the 1960's, Rude boys showed the magnificence and difficulty of Jamaica, and Rastafarians had a tendency to come back to the ancient civilization of America. In the 1970's, Two-tone was the simple clothing for harmonizing among human races. In the 1990's, Jamaica look influenced by the above has been the Lege fashion introduced to a high fashion, appearing in the special bright color, applique, unique hair style, and so on. (4) In the 1950's, Sufers pursued natural rhythm, getting out of everything. In the 1970' s, Skaters enjoyed the speed on the paved road. In the 1980's, Casuals emphasized the spirit of cooperation of young-things. In the 1990's, Casual look Influenced by the above has been the fashion that forms the activity, function and strong spirit of cooperation by pursuing comfortable life and sports in the tension of life and variety of modern society. (5) It was hard for Bikers to adjust themselves in society after the war. In the 1950's, Coffee bar cowboys were the reckless running boys in the leather jacket. In the 1960's, Rockers created the group originality as disobedient outsiders and Greasers imitated Rolling Stones. In the 1980's, Punks resisted the viewpoint of the old generation in offensive fashion. In the 1990's, Cyberpunk influenced by the above has pursued the classless structure, electronic music and metallic clothing that forebodes gloomily as the computer generation of ultra-modern science times. Accordingly, in understanding a complex modern fashion phenomenon, it was analyzed that the street styles of the past, from World War II to the 1980's, were reflected in that of the 1990's dividing into the five types in a word, namely Acid Jazz, Grunge look, Jamaica look, Casual look and Cyberpunk.

  • PDF

EFFECT OF VARIOUS MECHANICAL TREATMENTS ON TITANIUM PLASMA SPRAYED IMPLANT SURFACES (Titanium plasma sprayed implant에 관한 여러가지 기계적 표면처리방법이 implant표면조도에 미치는 영향)

  • Yu, Hyeon-Seok;Park, Jae-Wan;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.493-506
    • /
    • 1993
  • For maintenance of an ailing or failed implant it is essential to treat the implant fixture surface so as to remove bacterial endotoxin and make a surface tolerated by surrounding soft and hard tissue. Thus in this study the method that makes the smoothest surface treated with a high speed diamond bur, a low speed diamond bur, a stone, a rubber point or Jetpolisher was studied. With the profilomenter a mean value of $R_{max}$ was measured. The hight speed diamond, the rubber point and the Jetpolisher showed a mean $R_{max}\;7.77{\mu}m$. The low speed diamond bur, the rubber, point and the Jetolisher made a mean value of $R_{max}\;8.44{\mu}m$. The stone, the rubber point and the Jetolisher showed the smoothest surfaces with a mean value of $R_{max}\;6.24{\mu}m$. TPS (titanium plasma sprayed) areas showed a mean vlaue of $R_{max}\;24.42{\mu}m$, and the smooth surfaced titanium disc manufactured by the company (IMZ, Germany) shows a mean value of $R_{max}\;3.00{\mu}m$. Under the SEM examination the disc treated with a high speed diamond bur, a rubber point and a Jetpolisher showed partially remaining TPS particles, but the height of these particles were reduced remarkably compared with those of the original TPS. The disc treated with a low speed diamond bur, a rubber point and a Jetpolisher showed a rough topography with remaining TPS on the entire surface. A stone, a rubber point and a Jetpolisher removed almost TPS and the bulk titanium metal was exposed and some scratches were made by the stone. All treated discs were revealed as rougher than the smooth surface disc manufactured by the company. An untreated TPS disc shows a very irregular surface and a $40{\mu}m$ height of the plasma sprayed areas.

  • PDF

International Space Law on the Protection of the Environment (환경보호에 관한 국제 우주법연구)

  • Kim, Han-Taek
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.25 no.1
    • /
    • pp.205-236
    • /
    • 2010
  • This article deals with international space law for the environmental protection in outer space especially for space debris arising from space activities. After studying 1967 Outer Space Treaty, 1968 Rescue Agreement, 1972 Liability Convention, 1975 Registration Convention and 1979 Moon Agreement, we could find few provisions dealing with space environment in those treaties. During the earlier stages of the space age, which began in the late 1950s, the focus of international law makers was the establishment of the basic rules of space law governing the states' activities in outer space. Consequently the environmental issues and the risks that might arise from the generation of the space debris did not receive priority attention within the context of the development international space law. Although the phrases such as 'harmful contamination', 'harmful interference', 'disruption of the environment', 'adverse changes in the environment' and 'harmfully affecting' in relation to space environment were used in 1967 Outer Space Treaty and 1979 Moon Agreement, their true meaning was not definitely settled. Although 1972 Liability Convention deals with compensation, whether the space object covers space debris is unclear despite the case of Cosmos 954. In this respect international lawyers suggest the amendment of the space treaties and new space treaty covering the space environmental problems including the space debris. The resolutions, guidelines and draft convention are also studied to deal with space environment and space debris. In 1992 the General Assembly of the United Nations passed resolution 47/68 titled "Principles Relevant to the Use of Nuclear Power Sources in Outer Space" for the NPS use in outer space. The Inter-Agency Space Debris Coordination Committee; IADC) issued some guidelines for the space debris which were the basis of "the UN Space Debris Mitigation Guidelines" approved by COPUOS in its 527th meeting. In 1994 the 66th conference of ILA adopted "International Instrument on the Protection of the Environment from Damage Caused by Space Debris". Although those resolutions, guidelines and draft convention are not binding states, there are some provisions which have a fundamentally norm-creating character and softs laws.

  • PDF

The Design and Application of Vibrator Type(AM) Combination Apparatus for Improving Police Equipment for Fugitive Prevention (도주방지용 경찰장구의 기능개선을 위한 진동자 방식(AM) 결속장치 설계 및 응용)

  • Choi, Ki-Nam;Lee, Seon-Jeh
    • Convergence Security Journal
    • /
    • v.11 no.2
    • /
    • pp.13-24
    • /
    • 2011
  • Policemen judge the situations rationally and use their equipment such as handcuffs and rope within the purview, finding them needed to arrest criminals in the act who commit crimes which conforms to death penalty, life imprisonment or long imprisonment for over 3 years in accordance with Clause 10-2, Article 1 of the Police Mandate Law and prevent fleeing from them, defend their and others' lives and bodies, or if there are probable causes to be recognized that using equipment is necessary to restrain the interference with government officials in the execution of their duties. However, as the cases which the criminals run away in handcuffs or with both hands tied occur, it results in the waste of police force, distrust and enormous trouble in the pursuit of their duties. Therefore, if the way to perceive fleeing of criminals who have already worn the police equipment by some simple assistive devices without developing other new equipment, it will be very effective for police duties. This study is about the combination apparatus for fugitive prevention attached to the existing handcuffs and rope whose alert sounds let the staffs working inside the office perceive the fleeing of wanted criminals and examined suspects who wear the handcuffs or are tied up with rope, providing that they go through the exit where a transmitter and a receiver were set. The combination apparatus for fugitive prevention which the study introduces contains the connecting parts which connect a flexible tube(cognition tags inside of the tube) of connector equipped with the police equipment with the ends of the tube and the part where these two meet and which connect them inside of the tube. The connecting parts are easy to be attached to the police equipment such as handcuffs and rope, but hard to be dismantled by the people tied up with the equipment. It enables watchers to perceive the fleeing of wanted criminals and examined suspects who wear the handcuffs or are tied up with rope, providing that they go through the exit where a transmitter and a receiver were set. Plus, if it is combined together with the portable receiver, it can be installed on the patrol cars and easily adopted to supervise illegally accessing of evidences. It is also avaliable to be adjunctively utilized for the handcuffs provided and the cost is so reasonable. Owing to its snap-on way to the cuffs, it can clear up any invasion of privacy and it can not be used as a self-injury tool because of the soft tube. Using AM Tag minimizes the lack of malfunction.

Biology of Three Species of the Genus Tipula (Diptera: Tipulidae) in Korea (한국산 Tipula속(파리목 : 각다귀과) 3종의 생태)

  • Kim, Dong-Sang;Lee, Jong-Eun
    • Korean journal of applied entomology
    • /
    • v.46 no.2
    • /
    • pp.201-212
    • /
    • 2007
  • This study was conducted to investigate the biology of three species, Tipula latemarginata Alexander, T. nova Walker and T. aino Alexander, of the Genus Tipula in Korea. Field surveys for the biology of the species were carried out at the three sites of Neaseong Stream area in Bongwha County from January 2001 to December 2005. Also many individuals of the species were reared in laboratory to investigate the biology. The larval habitats of the species were streams, rivers, paddy fields, damp earth or leaky revetments. The Tipula larvae were herbivorous. Newly-hatched first instar larvae fed on soft algae, and the larvae gradually fed on leaves, stems and roots of a variety of plants or hard leaf litters, as they grew. During the molting of the larvae their body kept moving from left to right and up and down. Molting usually took not more than 2 hours, and about four hours after molting, the larvae started to eat heavily. The Tipula larvae in aquatic places moved to drier land for pupation and went through short prepupal stage lasting 1-2 days for pupation at fourth instar larval stage. When emerging, the Tipula pupae placed their head and thorax on the earth, but the other parts in the earth. Emergence from the pupal case required about 20 min. to one hour. Mating of Tipula adults took place within 5-7min. after emergence and the duration of mating was about 40 min. The female adults of the species laid eggs by walking with 3 pairs of legs over the damp earth or algal beds. Their body was positioned vertically on the ground with their wings spread $120^{\circ}$ and legs landed on the surface. The oviposition usually took place from one day to 4 days after emergence and the number of eggs carried by female adults were an average of 501-760 per individual. Tipula adults didn't normally feed, and drank water only occasionally. For a few days after emergence, the adults reared in the laboratory rarely drank water. As they neared to death, however, they frequently drank water. The longevity of adults reared in the laboratory with only water during the summer was ca. 4-9 days and males usually survived a little longer than females. The longevity of T. nova was increased 3 times or more as much by feeding them 3% sugar water. Male adults of T. latemarginata outnumbered female adults by 2.6 : 1 in the fields.

Influence of the Food Intake Ability and the Number of Remaining Teeth on Oral Health Related Quality of Life in Some Elderly People (일부 노인의 저작강도별 음식섭취능력과 잔존치아수가 구강건강관련 삶의 질에 미치는 영향)

  • Kim, Da-Hye;Hwang, Soo-Jeong
    • Journal of dental hygiene science
    • /
    • v.16 no.1
    • /
    • pp.53-61
    • /
    • 2016
  • Eating supports to gain energy and nutrition and improves quality of life. Ageing affects the food intake ability due to loss of natural teeth and the progressive muscle degeneration. Our objective was to investigate how the food intake ability (FIA) and the remaining teeth could influence on oral health related quality of life in the elderly. This study was performed with 503 elderly subjects living in Daejeon, Korea. The questionnaire with the FIA with 30 Korean food and Oral Health Impact Profile 14 (OHIP-14) and oral examination were surveyed. The five groups according to cluster analysis of FIA had the different numbers of remaining teeth and functional posterior teeth with opposing teeth or prosthesis significantly: group 1, $21.78{\pm}8.27$ and $2.80{\pm}2.63$; group 2, $16.75{\pm}7.87$ and $2.16{\pm}2.44$; group 3, $14.68{\pm}9.77$ and $1.73{\pm}2.30$; group 4, $9.93{\pm}8.13$ and $0.78{\pm}1.68$; group 5, $10.18{\pm}8.37$ and $0.51{\pm}1.22$. The more foods the subjects could masticate, the better oral health related quality of life they had. The medium FIA, soft FIA and the number of remaining teeth could explain 46% of OHIP-14, but hard FIA could not in the multiple regression model. We suggested to develop the oral health program for the elderly to be able to eat the food with medium physical property at least be helpful to improve oral health related quality of life.