• Title/Summary/Keyword: Soft stabilization

Search Result 104, Processing Time 0.029 seconds

Estimation of shear strength parameters of lime-cement stabilized granular soils from unconfined compressive tests

  • Azadegan, Omid;Li, Jie;Jafari, S. Hadi
    • Geomechanics and Engineering
    • /
    • v.7 no.3
    • /
    • pp.247-261
    • /
    • 2014
  • Analytical and numerical modeling of soft or problematic soils stabilized with lime and cement require a number of soil parameters which are usually obtained from expensive and time-consuming laboratory experiments. The high shear strength of lime and cement stabilized soils make it extremely difficult to obtain high quality laboratory data in some cases. In this study, an alternative method is proposed, which uses the unconfined compressive strength and estimating functions available in literature to evaluate the shear strength parameters of the treated materials. The estimated properties were applied in finite element model to determine which estimating function is more appropriate for lime and cement treated granular soils. The results show that at the mid-range strength of the stabilized soils, most of applied functions have a good compatibility with laboratory conditions. However, application of some functions at lower or higher strengths would lead to underestimation or overestimation of the unconfined compressive strength.

Mechanical characteristics of cement-stabilized kaolin by SEM analysis (SEM 해석을 이용한 시멘트 안정처리 카올린의 공학적 특성)

  • Lee, Kyu-Hwan;Jung, Dae-Suck
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1142-1147
    • /
    • 2006
  • Cement-stabilized clay has widespread applications in Deep Mixing projects, whereby soft deep clay deposits are improved through the addition of cement. While much research on this subject has taken place over the past decade, the strength and deformation behaviour of cement-stabilized clay is still not well understood. An extensive laboratory program was conducted on kaolin stabilized with up to 10% cement. Water curing was employed for durations up to 112 days. To study the microstructure of raw and stabilized soil, use is made of SEM. Micrographs of selected raw and stabilized soil were obtained. These micrographs were closely analyzed for any change in the microstructure of the soil as a result of stabilization.

  • PDF

EFFECTIVENESS ANALYSIS OF GROUND IMPROVEMENT TREATED BY DYNAMIC CONSOLIDATION (동압밀공법을 이용한 지반개량 사례연구)

  • 양정수;손준익
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1992.10a
    • /
    • pp.137-144
    • /
    • 1992
  • This paper reports a case study of dynamic consolidation. The objective of the study is to evaluate the effectiveness of ground improvement at the site for Hyundai Petrochemical Compound constructed at Daesan-Myeon, Seosan-Gun in the western shores of Korea. The site ground was prepared by filling on the existing soft marine deposit which consists of a loose granular soil layer and a medium stiff clay layer. For the stabilization of site ground, the compaction was executed in three different procedures with same pounder weigh, drop height and imprint spacing. The post investigation showed that the object was successfully achieved indicating a significant increase of bearing capacity of the treated ground. In this study the effectiveness of dynamic consolidation is evluated for various factors the applied energy, temping sequences, the radial distance from the imprint location and the depth of bed rock.

  • PDF

Phenolic Compounds in Persimmon Fruits and Stabilization of Discoloring Compounds (감의 페놀성 화합물과 변색관련 물질의 안정화)

  • 박용곤;김홍만;강윤한
    • The Korean Journal of Food And Nutrition
    • /
    • v.13 no.2
    • /
    • pp.103-110
    • /
    • 2000
  • This study was conducted to determine changes in phenolic compounds of astrigent persimmons before and after softening process and evaluate discoloring properties of major phenolic compounds. Phenolic compounds in soft persimmons were mainly composed of catechins and chlorogenic acid. Although contents of phenolic compounds were reduced during the softening process, little change in the ratio of catechins to total phenolic compounds was observed. Most of phenolic compounds in damaged astringents persimmons were existed in the high molecular weight fraction and more phenolic compounds were extracted at the temperature higher than room temperature. To evaluate discoloring abilities of phenolic compounds, phenolic compounds were dissolved separately into water or 80% methanol. With presence of various amounts of anti-discoloring agents such as vitamin C, citric acid, and L-cystein, (+)catechin was significantly reduced.

  • PDF

Tension Modeling and Looper-Tension ILQ Servo Control of Hot Strip Finishing Mills (열간 사상압연기의 장력 연산모델과 루퍼-장력 ILQ 서보 제어)

  • Hwang, I.C.;Park, C.J.
    • Journal of Power System Engineering
    • /
    • v.12 no.1
    • /
    • pp.72-79
    • /
    • 2008
  • This paper designs a looper-tension controller for mass-flow stabilization in hot strip finishing mills. By Newton's 2nd law and Hooke's law, nonlinear dynamic equations on the looper-tension system are firstly derived, and linearized by a linearization algorithm using a Taylor's series expansion. Moreover, a tension calculation model is obtained from the nonlinear dynamic equations which is called as a soft sensor of strip tension between two neighboring stands. Next, a looper-tension servo controller is designed by an ILQ(Inverse Linear Quadratic optimal control) algorithm, and it is combined with a minimal disturbance observer which to attenuate speed disturbances by AGC and operator interventions, etc.. Finally, it is shown from by a computer simulation that the proposed ILQ controller with a disturbance observer is very effective in stabilizing the strip mass-flow under some disturbances, moreover it has a good command following performance.

  • PDF

PDMS Nanoslits without Roof Collapse

  • Lee, Jin-Yong;Yun, Young-Keu;Kim, Yoo-Ri;Jo, Kyu-Bong
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.8
    • /
    • pp.1793-1797
    • /
    • 2009
  • Soft lithography of polydimethyl-siloxane (PDMS), an elastomeric polymer, has enabled rapid and inexpensive fabrications of microfluidic devices for various biochemical and bioanalytical applications. However, fabrications of nanostructured PDMS components such as nanoslits remain extremely challenging because of deformation of PDMS material. One of the well-known issues is the unwanted contact between the surfaces of PDMS roof and bottom substrate, called ‘roof collapse’. Here we have developed a novel approach for the facile stabilization of PDMS nanoslits in the low height (130 nm)/width (100 $\mu$m) ratio without roof-collapse. Within 130 nm high nanoslits, we demonstrate the confinement of single DNA molecules. We believe that this approach will serve as a key to utilize PDMS as nanoslits for integrated microfluidic devices.

A Correlation between Axis-Rotation and Corneal Astigmatism in Toric Soft Contact Lens Fitting (토릭소프트렌즈 피팅 시 축 회전과 각막난시와의 상관관계)

  • Park, Hyung Min;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.189-198
    • /
    • 2014
  • Purpose: The present has analyzed the correlation between the direction of lens and the amount of rotation upon soft toric contact lens fitting after classifying the corneal astigmatism. Methods: Soft toric contact lens was fitted on 114 with-the-rule astigmatic eyes with total astigmatism of at least -0.75 D in their 20s and 30s according to the fitting guideline of the manufacturer and the correlation between the astigmatic degree and the rotational direction/amount of rotation was analyzed by when keeping the eyes on the front and by changing the direction of gaze. As for re-orientation movement. The speed of lens re-orientation and total amount of lens rotation was compared and analyzed by corneal astigmatism after mis-location of lens of $45^{\circ}$ to temporal and nasal direction, respectively. Results: The positive correlations were shown between corneal astigmatism and the direction of lens rotation and between corneal astigmatism and the amount of lens rotation. Meanwhile, the amount of lens rotation was different by the direction of gaze however, there was no correlation with corneal astigmatism. The speed of lens re-orientation was fastest in the group of high astigmatic degree when the lens was mis-located to both temporal and nasal directions. Conclusions: For optimal axis stabilization of toric soft lens, it is proposed that the adjustment of fitting guideline considering corneal astigmatism is necessary since the current fitting guideline is only based on total astigmatism.

Study on Applicability of Simultaneous Multiple Compaction Grouting Method in Soft Clay Ground (점성토 연약지반에서의 다중 동시주입 컴팩션 그라우팅 공법 적용성 연구)

  • Lee, Hyobum;Jung, Hyun-Seok;Jung, Eui-Youp;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.779-788
    • /
    • 2019
  • The compaction grouting method is one of the conventional ground improvement methods, which consolidates and compacts the surrounding ground through the injection of grout materials with low mobility. Injecting the grout into the ground can improve the soil properties, as well as form a composite of soil-grout columns. However, the conventional grout pumping is not applicable to handle multiple injection holes at the same time, which may diminish its constructability when the construction time is not enough. This paper proposes a simultaneous multiple compaction-grouting method using a new pump system developed to cover up simultaneously three injection holes at a time. Field injection tests with a single injection hole and with triangular arrangement of injection holes were conducted to evaluate the applicability of the proposed method to soft clay ground. In addition, a series of standard penetration tests (SPTs) were performed to assess the efficiency of each arrangement in improving the soft ground. It is noted from the in-situ test results that the interval distances between injection holes and the elapse time for ground stabilization are the crucial factors governing the applicability of the simultaneous multiple compaction-grouting method to improve the soft clay ground.

Superior Gluteal Artery Perforator Turn-Over Flap Coverage for Lumboscaral Soft Tissue Defect in Ambulatory Patient (보행 환자에서의 위볼기동맥천공지뒤집기피판을 이용한 허리엉치 부위 연부조직 결손의 치료)

  • Moon, Suk-Ho;Kim, Dong-Seok;Oh, Deuk-Young;Lee, Jung-Ho;Rhie, Jong-Won;Seo, Je-Won;Ahn, Sang-Tae
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.712-716
    • /
    • 2010
  • Purpose: Extensive lumbosacral defects after removal of spinal tumors have a high risk of wound healing problems. Therefore it is an effective reconstructive strategy to provide preemptive soft tissue coverage at the time of initial spinal surgery, especially when there is an instrument exposure. For soft tissue reconstruction of a lumbosacral defect, a variation of the gluteal flap is the first-line choice. However, the musculocutaneous flap or muscle flap that is conventionally used, has many disadvantages. It damages gluteus muscle and causes functional disturbance in ambulation, has a short pedicle which limits areas of coverage, and can damage perforators, limiting further surgery that is usually necessary in spinal tumor patients. In this article, we present the superior gluteal artery perforator turn-over flap that reconstructs complex lumbosacral defects successfully, especially one that has instrument exposure, without damaging the ambulatory function of the patient. Methods: A 67 year old man presented with sacral sarcoma. Sacralectomy with L5 corpectomy was performed and resulted in a $15{\times}8\;cm$ sized complex soft tissue defect in the lumbosacral area. There was no defect in the skin. Sacral stabilization with alloplastic fibular bone graft and reconstruction plate was done and the instruments were exposed through the wound. A $18{\times}8\;cm$ sized superior gluteal artery perforator flap was designed based on the superior gluteal artery perforator and deepithelized. It was turned over 180 degrees into the lumbosacral dead space. Soft tissue from both sides of the wound was approximated over the flap and this provided in double padding over the instrument. Results: No complications such as hematoma, flap necrosis, or infection occurred. Until three months after the resection, functional disturbances in walking were not observed. The postoperative magnetic resonance imaging scan shows the flap volume was well maintained over the instrument. Conclusion: This superior gluteal artery perforator turn-over flap, a modification of the conventional superior gluteal artery perforator flap, is a simple method that enabled the successful reconstruction of a lumbosacral defect with instrument exposure without affecting ambulatory function.

Percutaneous Vertebroplasty in Spinal Metastasis and Myeloma : 25 Cases Experience (척추 전이암 및 골수종 환자를 대상으로 시행한 경피적 척추체 성형술)

  • Park, Woo-Min;Jang, Jee-Soo;Rhee, Chang-Hun;Gwak, Ho-Shin;Lee, Seung-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.11
    • /
    • pp.1484-1490
    • /
    • 2000
  • Objectives : In spinal metastasis and myeloma, percutaneous vertebroplasty could be an effective treatment method to provide spinal stabilization and to relief pain for early rehabilitation. The authors report twenty-five cases the clinical results of percutaneous vertebroplasty for twenty-five cases of spinal metastasis and myeloma. Materials and Methods : From September 1998 to December 1999, seventy percutaneous vertebroplasties(PVP) were performed for spinal metastases and myeloma in 25 patients, sixteen women and nine men ranging in age from 34 to 74. The primary malignancies were 6 multiple myelomas, and in metastatic tumore from various origin. All patients complained of severe pain and had osteolytic vertebral body destructions without spinal cord compression. To evaluate clinical improvement, suObjective verbal analogue pain score(VAS) and Karnofsky performance scale(KPS) were used. Thin sliced(2mm-thickness) sectional computed tomography(CT) was performed before and after PVP. Plain X-ray film was followed up every 1 month to assess the vertebral column stability. Results : In 25 patients, a total of seventy PVPS were performed successfully : 6 cervical, 33 thoracic and 31 lumbar vertebrae. Most patients had clear improvement of pain after PVP ; mean as score was 8.1 and 2.9 before and after PVP, respectively. Improvement was maintained in most patients. No further collapse of treated vertebrae was observed(mean follow-up, 7 months). Leakage of PMMA was notod in the spinal canal(13 levels), neural foramen (2 levels), adjacent disk(15 levels), paravertebral soft tissue(14 levels) and vein(8 levels). Pulmonary embolism was detected in three patients after the procedure, but was not associated with clinical symptoms. Conclusion : These results indicate that percutaneous vertebroplasty can be valuable treatment method in osteolytic spinal metastasis and myeloma, providing immediate pain relief and spinal stabilization and contributing to early rehabilitation.

  • PDF