• Title/Summary/Keyword: Soft plate

Search Result 240, Processing Time 0.023 seconds

Irreducible Spacer Subluxation after Total Ankle Replacement Arthroplasty in a Patient with Rheumatoid Arthritis: A Case Report (류마티스 환자의 발목 인공관절 치환술 이후 발생한 정복되지 않는 충전물의 아탈구: 증례 보고)

  • Seo, Dong-Kyo;Kim, Sang Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.25 no.4
    • /
    • pp.181-184
    • /
    • 2021
  • End-stage ankle arthritis is a debilitating condition that causes functional limitations and consequently a poor quality of life. Total ankle replacement arthroplasty is a good alternative to arthrodesis for preserving the ankle's range of motion. However, many complications can occur in patients with rheumatoid arthritis and with poor soft tissue and bone conditions. A 61-year-old female experienced spacer subluxation after surgery, which was not reduced by medial soft tissue release and spacer change. Buttress plating was found to be a good treatment option to prevent spacer subluxation and can be considered in patients with rheumatoid arthritis with bone erosion and soft tissue damage.

Analysis of Golf Swing Motion and Applied Loads on the Human Body Using Soft-$Golf^{TM}$ Club (소프트 골프 클럽을 이용한 골프 스윙 동작과 인체 작용 하중 분석)

  • Kwak, Ki-Young;So, Ha-Ju;Kim, Sung-Hyeon;Kim, Nam-Gyun;Kim, Dong-Wook
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.472-478
    • /
    • 2011
  • The purpose of this study was to analyze the kinetic effect of Soft-$golf^{TM}$ instrument on the human body structure. To analyze the kinetic effect of Soft-$golf^{TM}$ instrument, Golf swing using Soft-$golf^{TM}$ instrument and regular golf instrument was captured. And then Upper limbs and lumbar joint torques was calculated via computer simulation. Five man participated this study. Subjects performed golf swing using a regular golf and Soft-$golf^{TM}$ instrument. Golf swing motion was captured using three position sensor, active infrared LED maker and force plate. Golf swing model was generated and simulated using ADAMS/LifeMOD program. As a results, joint torque during Soft-golf swing were lower than regular golf swing. Thus soft-golf swing have joint load lower than regular golf swing and contribute to reduce joint injury.

Tip Plasty using Biodegradable Plate as a Columella Strut (비주 버팀목으로 흡수성 고정판을 이용한 비첨 성형술)

  • Kim, Soo-Young;Lee, Soo-Hyang;Hwang, Eun-A;Choi, Hyun-Gon;Kim, Soon-Heum;Shin, Dong-Hyeok;Uhm, Ki-Il
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.259-264
    • /
    • 2010
  • Purpose: Most surgeons have used autogenous cartilage for columella strut graft. But the supply of autogenous cartilage is often limited. So, this study is to investigate the usefulness of biodegradable plate as columella strut material. Methods: We studied 19 patients who have secondary cleft nasal deformity. Patients were divided into two groups. Group A patients who were not closed their growth plate underwent columella strut graft only with biodegradable plate through endonasal approach. The biodegradable plate was inserted between nasal tip and anterior nasal spine. Group B patients were closed their growth plate. They had an operation for columella strut graft with biodegradable plate fixed with autogenous conchal cartilage. If nasal tip projection was insufficient, we performed additionally onlay graft on nasal tip with autogenous soft tissue or remnant cartilage. Results: As a result of mean 14 months follow-up, we achieved a good nasal tip projection, narrowing of interalar distance and symmetrical nostril shape. No specific complications were reported except 2 cases, which were the extrusion of biodegradable plate into the nasal cavity and Staphylococcus aureus infection. Conclusion: The columella strut graft using biodegradable plate is simple and effective method. Biodegradable plate can be a good substitute for columella strut in patients who can not use autogenous cartilages.

Bone Transport over the Plate for the Segmental Bone Defect of Tibia

  • Seo, Il;Oh, Chang-Wug;Kim, Joon-Woo;Park, Kyeong-Hyun
    • Journal of Trauma and Injury
    • /
    • v.31 no.2
    • /
    • pp.107-111
    • /
    • 2018
  • Segmental bone defects of the tibia present a challenging problem for the orthopedic trauma surgeon. These injuries are often complicated by soft tissue defects and infection. Many techniques are reported, from bone graft to bone transport. To our knowledge, bone transport over the plate in the distraction site has not been described for the treatment of tibial bone defect. We report an instance including procedure and subsequent complications after bone transport over the plate, to restore a tibial bone defect.

The Relationship between Loading Velocity and Ground Heaving Characteristics (재하속도와 지반융기 특성의 상호관계)

  • Oh, Se-Wook
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.3
    • /
    • pp.77-83
    • /
    • 2006
  • The purpose of this study is to analyze lateral displacement behavior of clay layers in case of the banking in soft ground through model tests. Seven model tests varying with thickness of soft clay and loading velocity are performed to correlate between ground heaving and loading velocity. In case of low loading velocity, vertical settlement below loading plate and small ground heaving are obviously observed. In case of the high loading velocity, it is shown that both soil displacement at the end of a loading plate and surface heaving are large. In addition, the calculated displacements show good agreement with three cases of field measurements in clay with high moisture contents so that we can predict the range of heaving area and the amount of heaving.

  • PDF

An Experimental Study on the Settlement Characteristics of Soft Ground in the Central West Coast Region (서해안 중부지역 연약지반의 침하특성 분석을 위한 실험적 연구)

  • Kim, Joon-Seok
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.786-793
    • /
    • 2021
  • Purpose: An experiment was conducted to analyze the characteristics of the settlement of soft clay soil in the central region of the west coast of Korea, which has a high silt content and is difficult to predict settlement due to various stress histories. Method: Field experiments were conducted for three cases. The settlement amount of the subsidence plate was measured in each case, and the following conclusions were drawn by analyzing Terzaghi's one-dimensional consolidation settlement amount, both the hyperbolic method and the Asaoka method. Result: The predicted value by Terzaghi was analyzed to be the largest in all cases, and it was predicted to be 111% to 187% larger than the subsidence plate settlement value. That is, the subsidence plate settlement value, which is the amount of settlement of the actual ground, showed a settlement of 53.4~89.9% compared to the predicted value of Terzaghi. Therefore, it was analyzed that the expected settlement of the Terzaghi method in the clay soft ground of the central west coast of Korea is more than the actual settlement. Conclusion: It was analyzed that the Asaoka method and the hyperbolic method presented relatively similar results, and in practice, predicting the settlement amount smaller than the actual settlement amount may cause a risk, so the hyperbola analysis method predicted 6~14% larger than the actual settlement amount can be used as a safety side.

Development of a soft X-ray microscopy system for Biological Application (생물의료용 연 X-선 현미경 시스템 개발)

  • Kim, Gyeong-U;Gwon, Yeong-Man;Kim, Gyu-Gyeom;Min, Jong-Hwan;Park, Jeong-Gwon;Im, Jong-Hyeok;Nam, Gi-Yong;Yun, Gwon-Ha;Min, Jin-Yeong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2005.02a
    • /
    • pp.264-265
    • /
    • 2005
  • In this paper the conceptual design and development of a compact vertical type soft x-ray microscope is described. This x-ray microscope operates in the water window wavelength region(2.3 ${\sim}$ 4.4nm), where natural contrast between carbon(protein) and oxygen(water) allows imaging of unstained biological material their natural, hydrated environment. Until now, operational x-ray microscopes are based on synchrotron radiation sources, which limit their accessibility. Many biologists would benefit from having the x-ray microscope as a tool among other tools in their own laboratory, For this purpose we introduced the compact vertical type soft X-ray microscope with 50 nm resolution for biomedical application. The compact vertical type soft x-ray microscope is based on a laser plasma x-ray source, doubled ellipsoidal condenser reflective optics, diffractive zone plate optics and MCP coupled with CCD to record an x-ray image.

  • PDF

Development of Induction Heated Hot Water Producer using Soft Switching PWM High Frequency Inverter

  • Fujita Kentarou;Moisseev Serguei;Gaimage Laknath;Chandhaket Sarawouth;Muraoka Hidekazu;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.491-494
    • /
    • 2003
  • This paper presents a new conceptual electromagnetic induction eddy current-based stainless steel plate spiral type heater for heat exchanger or Dual Packs Heater in hot water producer, boiler steamer and super heated steamer, which is more suitable and acceptable for new generation consumer power applications. In addition, all active clamped edge resonant PWM high frequency inverter using trench gate IGBTs power module can operate under a principle oi zero voltage soft communication with PWM is developed and demonstrated for a high efficient Induction heated hot water producer and boiler in the consumer power applications. This consumer induction heater power appliance using active clamp soft switching PWM high frequency inverter is evaluated and discussed on the basis of the simulation and experimental results.

  • PDF

Soft Mold Deformation of Large-area UV Impring Process (대면적 UV 임프린팅 공정에서 유연 몰드의 변형)

  • Kim, Nam-Woong;Kim, Kug-Weon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.4
    • /
    • pp.53-59
    • /
    • 2011
  • Recently there have been considerable attentions on nanoimprint lithography (NIL) by the display device and semiconductor industry due to its potential abilities that enable cost-effective and high-throughput nanofabrication. Although one of the current major research trends of NIL is large-area patterning, the technical difficulties to keep the uniformity of the residual layer become severer as the imprinting area increases more and more. In this paper we focused on the deformation of the $2^{nd}$ generation TFT-LCD sized ($370{\times}470mm^2$) large-area soft mold in the UV imprinting process. A mold was fabricated with PDMS(Poly-dimethyl Siloxane) layered glass back plate(t0.5). Besides, the mold includes large surrounding wall type protrusions of 1.9 mm width and the via-hole(7 ${\mu}m$ diameter) patterend area. The large surrounding wall type protrusions cause the proximity effect which severely degrades the uniformity of residual layer in the via-hole patterend area. Therefore the deformation of the mold was calculated by finite element analysis to assess the effect of large surrounding wall type protrusions and the flexiblity of the mold. The deformation of soft mold was verified by the measurements qualitatively.