• 제목/요약/키워드: Soft plate

검색결과 240건 처리시간 0.028초

Displacement pattern of the anterior segment using antero-posterior lingual retractor combined with a palatal plate

  • Seo, Kyung-Won;Kwon, Soon-Yong;Kim, Kyung A;Park, Ki-Ho;Kim, Seong-Hun;Ahn, Hyo-Won;Nelson, Gerald
    • 대한치과교정학회지
    • /
    • 제45권6호
    • /
    • pp.289-298
    • /
    • 2015
  • Objective: To evaluate and compare the effects of two appliances on the en masse retraction of the anterior teeth anchored by temporary skeletal anchorage devices (TSADs). Methods: The sample comprised 46 nongrowing hyperdivergent adult patients who planned to undergo upper first premolar extraction using lingual retractors. They were divided into three groups, based on the lingual appliance used: the C-lingual retractor (CLR) group (group 1, n = 16) and two antero-posterior lingual retractor (APLR) groups (n = 30, groups 2 and 3). The APLR group was divided by the posterior tube angulation; posterior tube parallel to the occlusal plane (group 2, n = 15) and distally tipped tube (group 3, n = 15). A retrospective clinical investigation of the skeletal, dental, and soft tissue relationships was performed using lateral cephalometric radiographs obtained pretreatment and post en masse retraction of the anterior teeth. Results: All groups achieved significant incisor and canine retraction. The upper posterior teeth did not drift significantly during the retraction period. The APLR group had less angulation change in the anterior dentition, compared to the CLR group. By changing the tube angulation in the APLR, the intrusive force significantly increased in the distally tipped tube of group 3 patients and remarkably reduced the occlusal plane angle. Conclusions: Compared to the CLR, the APLR provides better anterior torque control and canine tipping while achieving bodily translation. Furthermore, changing the tube angulation will affect the amount of incisor intrusion, even in patients with similar palatal vault depth, without the need for additional TSADs.

골연부 종양에서 저온 열처리한 자가골을 이용한 재건술 (Autogenous Low Heat Treated Bone Graft for Bone Reconstruction in Bone and Soft Tissue Tumors)

  • 전대근;이종석;김석준;조완형;곽봉준;이수용
    • 대한골관절종양학회지
    • /
    • 제4권2호
    • /
    • pp.81-87
    • /
    • 1998
  • Although autoclaved autogenous bone reconstruction is one of the established procedures, it may have some problems in bone regeneration and mechanical property. The purpose of this study is to evaluate the efficacy of more biologic and anatomical reconstruction where allograft is not readily available. From Aug.1991 to Feb. 1996 the authors analyzed 32 cases of reconstruction with autogenous low heat treated bone. Autogenous graft sites were humerus 4, tibia 4, pelvis 9, and 15 femur. Average follow-up period was 23(range;12-51) months. There were 49 graft-host junctional sites. Diaphysis was 22, metaphysis 10, and flat bone 17. Average duration of healing for the 38 united sites was 7 months. Average union time for each anatomical area 8 months in 19 diaphysis, 12 months in 7 metaphysis, and 12.7 months in 12 flat bone(pelvis). Eleven nonunion sites consisted of 3 diaphysis(3/22), 3 metaphysis(3/10), and 5 flat bone(5/17). Complications other than nonunion were local recurrence(4), bone resorption(3), graft fracture(2), osteomyelitis(1), metal failure(2), and wound infection(1). Initial bone quality and stable fixation technique was important for union rate. Plate and screw is a good method for diaphyseal lesion. Metaphyseal and flat bone are weak area for rigid fixation and one stage augmentation with iliac bone graft can be a salvage procedure.

  • PDF

SVR model reconstruction for the reliability of FBG sensor network based on the CFRP impact monitoring

  • Zhang, Xiaoli;Liang, Dakai;Zeng, Jie;Lu, Jiyun
    • Smart Structures and Systems
    • /
    • 제14권2호
    • /
    • pp.145-158
    • /
    • 2014
  • The objective of this study is to improve the survivability and reliability of the FBG sensor network in the structural health monitoring (SHM) system. Therefore, a model reconstruction soft computing recognition algorithm based on support vector regression (SVR) is proposed to achieve the high reliability of the FBG sensor network, and the grid search algorithm is used to optimize the parameters of SVR model. Furthermore, in order to demonstrate the effectiveness of the proposed model reconstruction algorithm, a SHM system based on an eight-point fiber Bragg grating (FBG) sensor network is designed to monitor the foreign-object low velocity impact of a CFRP composite plate. Simultaneously, some sensors data are neglected to simulate different kinds of FBG sensor network failure modes, the predicting results are compared with non-reconstruction for the same failure mode. The comparative results indicate that the performance of the model reconstruction recognition algorithm based on SVR has more excellence than that of non-reconstruction, and the model reconstruction algorithm almost keeps the consistent predicting accuracy when no sensor, one sensor and two sensors are invalid in the FBG sensor network, thus the reliability is improved when there are FBG sensors are invalid in the structural health monitoring system.

개에서 요골쪽앞발목굽힘근과 얕은앞발가락굽힘근을 이용한 앞발목 부위의 연부조직 결손 재건 증례 (Transposition of Flexor Carpi Radialis and Superficial Digital Flexor Muscles for Reconstruction of Carpal Injury in a Dog)

  • 소경민;김주호;이해범;허수영;고재진;이철호;전승기;김남수
    • 한국임상수의학회지
    • /
    • 제24권2호
    • /
    • pp.276-279
    • /
    • 2007
  • A 2-year-old male, 3 kg body weight Japanese Chin was injured in the automobile accident three months ago. The dog became antebrachiocarpal joint instability, and performed pancarpal arthrodesis using 3 K-wires in localanimal hospital. But, the result was failure. Therefore the dog was referred to Chonbuk Animal Medical Center, Chonbuk National University. In physical examination, right carpal joint instability, knuckling sign and pain were evident. In radiography, sclerosis was observed on the 4th carpal bone. Complete blood count (CBC), serum chemistry and urinalysis finding were within reference ranges. Pancarpal arthrodesis was re-performed using 7-hole plate. However, mild skin and muscle defects was appeared by skin tension of extremity. We expected that granulation would fill the defect, but inflammation was continued on the lesions for 3 days. So, operation which is filling it was done by using the muscle flap and tubed skin flap. The donor muscles were flexor carpi radialis and superficial digital flexor muscles. After 7 days, the muscle flap was survived, but tubed skin flap was necrosed. After 20 days, the skin defect was substituted with granulation tissues. The flexor carpi radialis muscle and superficial digital flexor muscle transposition can be a useful procedure for reconstructing soft tissue defects in the carpal and metacarpal areas.

Clinical courses and degradation patterns of absorbable plates in facial bone fracture patients

  • Kim, Young Min;Lee, Jong Hun
    • 대한두개안면성형외과학회지
    • /
    • 제20권5호
    • /
    • pp.297-303
    • /
    • 2019
  • Background: Absorbable plates are widely used in open reduction and internal fixation surgeries for facial bone fractures. Absorbable plates are made of polyglycolic acid (PGA), polylactic acid (PLA), polydioxane (PDS), or various combinations of these polymers. The degradation patterns of absorbable plates made from different polymers and clinical courses of patients treated with such plates have not been fully identified. This study aimed to confirm the clinical courses of facial bone fracture patients using absorbable plates and compare the degradation patterns of the plates. Methods: A retrospective chart review was conducted for 47 cases in 46 patients who underwent open reduction and internal fixation surgery using absorbable plates to repair facial bone fractures. All surgeries used either PLA/PGA composite-based or poly-L-lactic acid (PLLA)/hydroxyapatite (HA) composite-based absorbable plates and screws. Clinical courses were confirmed and comparisons were conducted based on direct observation. Results: There were no naturally occurring foreign body reactions. Post-traumatic inflammatory responses occurred in eight patients (nine cases), in which six recovered naturally with conservative treatment. The absorbable plates were removed from two patients. PLA/PGA compositebased absorbable plates degraded into fragments with non-uniform, sharp surfaces whereas PLLA/HA composite-based absorbable plates degraded into a soft powder. Conclusion: PLA/PGA composite-based and PLLA/HA composite-based absorbable plates showed no naturally occurring foreign body reactions and showed different degradation patterns. The absorbable plate used for facial bone fracture surgery needs to be selected in consideration of its degradation patterns.

저온 분사를 이용한 Cu계 비정질 코팅층의 제조 및 특성 연구 (Fabrication and Characterization of Cu-based Amorphous Coatings by Cold Spray Process)

  • 정동진;박동용;이진규;김형준;이기안
    • 대한금속재료학회지
    • /
    • 제46권5호
    • /
    • pp.321-327
    • /
    • 2008
  • Cu based amorphous ($Cu_{54}Zr_{22}Ti_{18}Ni_6$) coating was produced by cold spraying as a new fabrication process. The microstructure and macroscopic properties of amorphous coating layer was investigated and compared with those of cold sprayed pure Cu coating. Amorphous powders were prepared by gas atomization and Al 6061 was used as the substrate plate. X-ray diffraction results showed that Cu based amorphous powder could be successfully deposited by cold spraying without any crystallization. The Cu based amorphous coating layer ($300{\sim}400{\mu}m$ thickness) contained 4.87% porosity. The hardness of Cu based amorphous coating represented $412.8H_v$, which was correspond to 68% of the hardness of injection casted bulk amorphous material. The wear resistance of Cu based amorphous coating was found to be three times higher than that of pure Cu coating. The 3-point bending test results showed that the adhesion strength of Cu based amorphous coating layer was higher than that pure Cu coating. It was also observed that hard Cu base amorphous particle could easily deform soft substrate by particle collisions and thus generated strong adhesion between coating and substrate. However, the amorphous coating layer unexpectedly represented lower corrosion resistance than pure Cu coating, which might be resulted from the higher content of porosity in the cold sprayed amorphous coating.

Correlation analysis of periodontal tissue dimensions in the esthetic zone using a non-invasive digital method

  • Kim, Yun-Jeong;Park, Ji-Man;Cho, Hyun-Jae;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • 제51권2호
    • /
    • pp.88-99
    • /
    • 2021
  • Purpose: Direct intraoral scanning and superimposing methods have recently been applied to measure the dimensions of periodontal tissues. The aim of this study was to analyze various correlations between labial gingival thickness and underlying alveolar bone thickness, as well as clinical parameters among 3 tooth types (central incisors, lateral incisors, and canines) using a digital method. Methods: In 20 periodontally healthy subjects, cone-beam computed tomography images and intraoral scanned files were obtained. Measurements of labial alveolar bone and gingival thickness at the central incisors, lateral incisors, and canines were performed at points 0-5 mm from the alveolar crest on the superimposed images. Clinical parameters including the crown width/crown length ratio, keratinized gingival width, gingival scallop, and transparency of the periodontal probe through the gingival sulcus were examined. Results: Gingival thickness at the alveolar crest level was positively correlated with the thickness of the alveolar bone plate (P<0.05). The central incisors revealed a strong correlation between labial alveolar bone thickness at 1 and 2 mm, respectively, inferior to the alveolar crest and the thickness of the gingiva at the alveolar crest line (G0), whereas G0 and labial bone thickness at every level were positively correlated in the lateral incisors and canines. No significant correlations were found between clinical parameters and hard or soft tissue thickness. Conclusions: Gingival thickness at the alveolar crest level revealed a positive correlation with labial alveolar bone thickness, although this correlation at identical depth levels was not significant. Gingival thickness, at or under the alveolar crest level, was not associated with the clinical parameters of the gingival features, such as the crown form, gingival scallop, or keratinized gingival width.

Development of Three-Dimensional Deformable Flexible Printed Circuit Boards Using Ag Flake-Based Conductors and Thermoplastic Polyamide Substrates

  • Aram Lee;Minji Kang;Do Young Kim;Hee Yoon Jang;Ji-Won Park;Tae-Wook Kim;Jae-Min Hong;Seoung-Ki Lee
    • 한국전기전자재료학회논문지
    • /
    • 제37권4호
    • /
    • pp.420-426
    • /
    • 2024
  • This study proposes an innovative methodology for developing flexible printed circuit boards (FPCBs) capable of conforming to three-dimensional shapes, meeting the increasing demand for electronic circuits in diverse and complex product designs. By integrating a traditional flat plate-based fabrication process with a subsequent three-dimensional thermal deformation technique, we have successfully demonstrated an FPCB that maintains stable electrical characteristics despite significant shape deformations. Using a modified polyimide substrate along with Ag flake-based conductive ink, we identified optimized process variables that enable substrate thermal deformation at lower temperatures (~130℃) and enhance the stretchability of the conductive ink (ε ~30%). The application of this novel FPCB in a prototype 3D-shaped sensor device, incorporating photosensors and temperature sensors, illustrates its potential for creating multifunctional, shape-adaptable electronic devices. The sensor can detect external light sources and measure ambient temperature, demonstrating stable operation even after transitioning from a planar to a three-dimensional configuration. This research lays the foundation for next-generation FPCBs that can be seamlessly integrated into various products, ushering in a new era of electronic device design and functionality.

암버력 매립층의 동치환공법 현장 적용성 및 개량효과에 관한 연구 (Improvement Effect and Field Application of Dynamic Replacement Using Crushed Rock)

  • 이인환;이철희;신은철
    • 한국지반신소재학회논문집
    • /
    • 제18권4호
    • /
    • pp.1-13
    • /
    • 2019
  • 본 연구는 건설현장에서 발생하는 암버력을 재활용하여 연약지반 개량재료로 활용가능한 동치환공법의 적용성과 연약지반 개량효과를 고찰하는 것을 목적으로 하고 있다. 암버력 매립층에서 동치환공법 적용시 지반보강 효과를 파악하기 위하여 현장지반 조사를 통해 수집한 암버력과 현장시료를 바탕으로 실내실험 및 현장시험을 수행하였다. 암버력의 전단시험을 통해 내부마찰각과 겉보기 점착력을 도출하였으며, 현장시료의 적용성과 문제점을 확인하고 동치환공법 적용시 필요한 중추의 무게, 낙하고, 타격횟수 등을 분석하여 동치환 특성을 파악하였다. 현장 평판재하시험과 밀도시험을 통하여 개량된 지반의 지지력과 침하량을 계측하였으며, 수치해석을 통해 개량지반의 거동을 예측하였다. 본 연구를 통해서 암버력 매립층의 동치환공법시 지반 실험계수 CDR은 0.3~0.5로 수정 제안하였고, 100mm 이하 D90은 80mm이하, D15는 30mm이상의 입도범위를 가지는 암버력을 사용할 것을 제안하였다.

기계공학과에서 제시하는 Hands-on Experience 중심의 "엔지니어링 디자인" 교과목의 강의사례 (A Case Study of "Engineering Design" Education with Emphasize on Hands-on Experience)

  • 김홍찬;김지훈;김관주;김정수
    • 공학교육연구
    • /
    • 제10권2호
    • /
    • pp.44-61
    • /
    • 2007
  • 본 논문은 공학 교육에서 강조하고 있는 창의력, 협업 능력 및 의사소통능력의 함양을 주 목적으로 홍익대학교 기계 시스템디자인공학과에서 새로이 개발한 교과목에 관하여 소개하고자 한다. '기계 시스템 디자인공학과'는 엔지니어링 디자인을 강조하는 새로운 교과목을 갖춘, 기존 홍익대학교 기계공학과의 새로운 이름이다. 급변하는 교육환경과 산업계의 요구에 부응하기위해서 기계공학과는 아날로그 기반, 산업중심의 하드한 관점에서 디지털 기반, 인간 중심의 소프트한 가치 중심으로 그 교육 접근방식을 전환하였다. 이러한 관점에서 새로이 개설된 세 가지 학과목인 기계 시스템디자인 개론, 창의적 공학 설계, 제품디자인은 공통적으로 팀 프로젝트를 통해서 손으로 직접 만들고 대화하고 표현하는(이하 Hands-on experience)경험을 중요시 하고 있다. 또한 이들 과정에서는 브레인스토밍(Brain Storming)과 스케치를 통한 시제작(Prototyping) 과정을 강조하고 있으며, 전통적으로 다루기 힘들고 무거운 금속 소재 대신에 폴리스티렌 블록이나 카드보드와 같은 가볍고 유연성 있는 소재를 사용하여 가능한 다양하고 창의적인 원형(Prototype)을 만들고, 팀원들간의 활발한 의사소통을 체험 할 수 있도록 유도하였다. Hands-on experience 중심 프로그램들은 학생들로 하여금 협업능력을 강조한 학과목들을 통해 시각적이며 구체적인 체험을 하게 하여 전통적으로 분석적이고 수학적이며 추상적인 사고에 초점을 맞춘 공학과목들을 균형적으로 보완하는 역할을 할 것으로 보이며, 졸업 후 그들이 산업현장에서 접하게 될 복잡하고 구체적인 엔지니어링 과제들을 해결하는 엔지니어링 감각과 창의력을 개발하는데 중요한 역할을 할 수 있을 것으로 예상된다.