• Title/Summary/Keyword: Soft magnetic materials

Search Result 270, Processing Time 0.04 seconds

Hibernoma of Right Shoulder - A Case Report - (우측 견관절 부위에 발생한 동면종 - 증례 보고 -)

  • Kang, Ho-Jung;Hwang, Bo-Hyun;Jung, Min;Koo, Ja-Seung;Shin, Kyoo-Ho;Hahn, Soo-Bong;Kim, Sung-Jae
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.94-97
    • /
    • 2009
  • Purpose: Hibernoma is a very rare benign soft tissue tumor of the hypervascularized brown fat tissue with no malignant potential. Materials and Methods: However, it is difficult to differentiate a hibernoma from other malignant tumors, such as liposarcoma using computed tomography and magnetic resonance imaging, and a surgical resection with histological confirmation is the treatment of choice. Results: Histopathologically, hibernoma is composed of brown adipose cells that are polygonal and multivacuolated with a centrally located nucleus and granular cytoplasm, unlike white adipose cells. Conclusion: This article describes a patient with a histologically-confirmed hibernoma of the right shoulder.

A Study of the Effect of Acoustic Noise Attenuator on Auditory Functional MRI (소음 감쇠기를 이용한 청각의 뇌기능 자기공명영상)

  • Kim, S.H.;Kim, I.S.;Lee, J.J.;Park, J.A.;Lee, Y.J.;Yeo, J.R.;Bae, S.J.;Lee, S.H.;Chang, Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.134-139
    • /
    • 2005
  • Purpose : To evaluate the usefulness of acoustic noise attenuator on auditory fMRI examination. Materials and methods : The acoustic noise attenuator consists of mask, earmuff and silicon earplug. The soft polyurethane sheet and polyurethane form , which has a good soundproof characteristic were used for mask and earmuff. Auditory fMRI experiments of 500 Hz pure tone stimulation were performed in three different cases; first all of mask, earmuff and earplug, secondly earmuff and earplug only and finally without attenuator in 4 normal hearing volunteers. For data acquisition, BOLD MR imaging technique was employed at a 1.5T MR scanner equipped with high performance gradient system. The raw data were analyzed using a SPM-99 analysis software and the activation maps were obtained. Results : In case of all items of acoustic attenuator used, the results revealed that activation was focused on primary auditory area. When only earmuff and earplug were used, the results showed that the activation spread over primary auditory and secondary associative areas. Last, when no device used, only weak activation was observed on the right auditory cortex. Conclusion : It is expected that the acoustic noise attenuator, which consists of earplugs, earmuffs and mask, is a very useful device in auditory fMRI study.

  • PDF

XAS Studies of Ion Irradaited MgO Thin Films

  • Suk, Jae-Kwon;Gautam, Sanjeev;Song, Jin-Ho;Lee, Jae-Yong;Kim, Jae-Yeoul;Kim, Joon-Kon;Song, Jong-Han;Chae, Keun-Hwa
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.312-312
    • /
    • 2012
  • Magnesium oxide has become focus for research activities due to its use in magnetic tunnel junctions and for understanding of do ferromagnetism. Theoretical investigations on such type of system indicate that the presence of defects greater than a threshold value is responsible for the magnetic behaviour. It has also been shown experimentally that by decreasing the film thickness and size of nanoparticles, enhancement/increase in magnetization can be achieved. Apart from the change in dimension, swift heavy ions (SHI) are well known for creating defects and modifying the properties of the materials. In the present work, we have studied the irradiation induced effects in magnesium oxide thin film deposited on quartz substrate via X-ray absorption spectroscopy (XAS). Magnesium oxide thin films of thickness 50nm were deposited on quartz substrate by using e-beam evaporation method. These films were irradiated by 200 MeV Ag15+ ion beam at fluence of $1{\times}10^{11}$, $5{\times}10^{11}$, $1{\times}10^{12}$, $3{\times}10^{12}$ and $5{\times}10^{12}ions/cm^2$ at Nuclear Science Centre, IUAC, New Delhi (India). The grain size was observed (as studied by AFM) to be decreased from 37 nm (pristine film) to 23 nm ($1{\times}10^{12}ions/cm^2$) and thereafter it increases upto a fluence of $5{\times}10^{12}ions/cm^2$. The electronic structure of the system has been investigated by X-ray absorption spectroscopy (XAS) measurements performed at the high energy spherical grating monochromator 20A1 XAS (HSGM) beamline in the National Synchrotron Radiation Research Center (NSRRC), Taiwan. Oxides of light elements like MgO/ZnO possess many unique physical properties with potentials for novel application in various fields. These irradiated thin films are also studied with different polarization (left and right circularly polarized) of incident x-ray beam at 05B3 EPU- Soft x-ray scattering beamline of NSRRC. The detailed analysis of observed results in the wake of existing theories is discussed.

  • PDF

Giant Schwannoma May Mimic Soft Tissue Sarcoma (악성 연부 종양으로 오인하기 쉬운 신경 및 연부조직의 거대 신경초종)

  • Kim, Yongsung;Jeon, Dae-Geun;Cho, Wan Hyeong;Song, Won Seok;Kim, Kyunghoon
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.511-519
    • /
    • 2020
  • Purpose: Schwannoma is a benign tumor that occurs mainly in the peripheral nerve. If the tumor is large or is in areas other than the nerves, it is likely to be mistaken for malignant soft tissue tumors. The authors reviewed 50 cases of giant schwannomas and assessed the distribution of the primary locations, clinical symptoms, radiological and pathological diagnosis, and diagnostic accuracy. Materials and Methods: Of the 214 pathologically confirmed schwannomas, 50 cases with a maximum diameter of 5 cm or more were extracted. The entire cohort was classified into three subgroups (major peripheral nerve, intramuscular, bone) according to the primary location, and the anatomical locations were specified. Results: When the entire cohort was classified according to the primary location, 14 tumors occurred in the major peripheral nerve, 31 cases in the muscle, and 5 cases in the bone. The mean size of the tumor in the entire cohort was 7.0 cm, and the intramuscular subgroup had the largest size with 8.0 cm. The radiological diagnosis revealed 33 out of 50 cases to be benign schwannoma (66.0%), 15 cases as low-grade malignancy (30.0%), and the remaining two cases (4.0%) as a suspicious tuberculosis abscess and tenosynovial giant cell tumor, respectively. On the clinical symptoms, Tinel sign was the most common in the peripheral nerve group with 78.6% (11/14), while 93.5% of the intramuscular group had palpation of the mass with a mean duration of 66.6 months. In the bone group, one out of five cases was reported as a low-grade malignancy. Two cases of postoperative complications were encountered; one was bleeding after tumor excision, which required hemostasis, and the other was peroneal nerve palsy after surgery. Conclusion: When assessing the large-sized soft tissue tumors in the muscles, the possibility of a benign schwannoma should be considered if 1) there is a long period of mass palpation and 2) non-specific findings in MRI. Preoperative pathology confirmation with a biopsy can help reduce the risk of overtreatment.

Differentiation of Recurrent Rectal Cancer and Postoperative Fibrosis: Preliminary Report by Proton MR Spectroscopy (재발성 직장암과 수술 후 섬유화의 감별 진단: 수소 MRS에 의한 예비보고)

  • Jeon Yong Sun;Cho Soon Gu;Choi Sun Keun;Kim Won Hong;Kim Mi Young;Suh Chang Hae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.24-31
    • /
    • 2004
  • Purpose : To know the differences of proton MR spectroscopic features between recurrent rectal cancer and fibrosis in post-operative period, and to evaluate the possibility to discriminate recurrent rectal cancer from post-operative fibrosis by analysis of proton MR spectra. Materials and Methods : We evaluated the proton MR spectra from 25 soft tissue masses in perirectal area that developed in post-operative period after operation for the resection of rectal cancer. Our series included 11 cases of recurrent rectal cancer and 14 of fibrotic mass. All cases of recurrent rectal cancer and post-operative fibrosis were confirmed by biopsy. We evaluated the spectra with an attention to the differences of pattern of the curves between recurrent rectal cancer and post-operative fibrosis. The ratio of peak area of all peaks at 1.6-4.1ppm to lipid (0.9-1.6ppm) [P (1.6-4.1ppm/P (0.9-1.6ppm)] was calculated in recurrent rectal cancer and post-operative fibrosis groups, and compared the results between these groups. We also evaluated the sensitivity and specificity for discriminating recurrent rectal cancer from post-operative fibrosis by analysis of $^1H-MRS$. Results : Proton MR spectra of post-operative fibrosis showed significantly diminished amount of lipids compared with that of recurrent rectal cancer. The ratio of P (1.6-4.1ppm)/P (0.9-1.6ppm) in post-operative fibrosis was much higher than that of recurrent rectal cancer with statistical significance (p < .05) due to decreased peak area of lipids. Mean (standard deviations of P (1.6-4.1ppm)/P (0.9-1.6ppm) in post-operative fibrosis and recurrent rectal cancer group were $2.71{\pm}1.48\;and\;0.29{\pm}0.11$, respectively. With a cut-off value of 0.6 for discriminating recurrent rectal cancer from post-operative fibrosis, both the sensitivity and specificity were $100\%$ (11/11, and 14/14). Conclusion : Recurrent rectal cancer and post-operative fibrosis can be distinguished from each other by analysis of proton MR spectroscopic features, and $^1H-MRS$ can be a new method for differential diagnosis between recurrent rectal cancer and post-operative fibrosis.

  • PDF

Removal of PVC from Mixed Plastic Waste by Combination of Air Classification and Centrifugal Process (풍력(風力) 및 습식비중(濕式比重) 선별(選別)에 의한 혼합(混合)폐플라스틱 종말품(終末品)으로부터 PVC 제거(除去)에 관한 연구(硏究))

  • Choi, Woo-Zin;Yoo, Jae-Myung
    • Resources Recycling
    • /
    • v.16 no.5
    • /
    • pp.71-76
    • /
    • 2007
  • The mixed plastic waste generated from households after hand-picking and/or mechanical sorting processes amounts to 1,750,000 ton in 2006, and most of these waste are finally end up with landfill and/or incineration due to the lacks of separation technologies and economical reasons. The mixed plastic wastes can not be used as raw materials for chemical and/or thermal recycling processes because of their high content of PVC(upto 4.0 wt.%). In the present research, gravity separation system has been developed to remove PVC from the mixed plastic waste and to recover the PO-type plastics. This system mainly consists of air classification, magnetic separation, one-step crushing, feeding system at fixed rate and wet-type gravity separation system. The gravity system based on centrifugal separation has been developed at capacity of 0.5 ton/h and it consists of mixing, precleaning, separation, dewatering, recovery system and wastewater treatment system, etc. The main objective of this process is to achieve high separation efficiency of polyolefins with less than 0.3 wt.% PVC content and less than 10% moisture content in the final products. In addition, a crushing unit of with 8 rotor system is also developed to improve the crushing efficiency of soft-type plastics. The system with a capacity of 1.0 ton/h is developed and operational results are presented.

MRI Evaluation of Suspected Pathologic Fracture at the Extremities from Metastasis: Diagnostic Value of Added Diffusion-Weighted Imaging

  • Sun-Young Park;Min Hee Lee;Ji Young Jeon;Hye Won Chung;Sang Hoon Lee;Myung Jin Shin
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.812-822
    • /
    • 2019
  • Objective: To assess the diagnostic value of combining diffusion-weighted imaging (DWI) with conventional magnetic resonance imaging (MRI) for differentiating between pathologic and traumatic fractures at extremities from metastasis. Materials and Methods: Institutional Review Board approved this retrospective study and informed consent was waived. This study included 49 patients each with pathologic and traumatic fractures at extremities. The patients underwent conventional MRI combined with DWI. For qualitative analysis, two radiologists (R1 and R2) independently reviewed three imaging sets with a crossover design using a 5-point scale and a 3-scale confidence level: DWI plus non-enhanced MRI (NEMR; DW set), NEMR plus contrast-enhanced fat-saturated T1-weighted imaging (CEFST1; CE set), and DWI plus NEMR plus CEFST1 (combined set). McNemar's test was used to compare the diagnostic performances among three sets and perform subgroup analyses (single vs. multiple bone abnormality, absence/presence of extra-osseous mass, and bone enhancement at fracture margin). Results: Compared to the CE set, the combined set showed improved diagnostic accuracy (R1, 84.7 vs. 95.9%; R2, 91.8 vs. 95.9%, p < 0.05) and specificity (R1, 71.4% vs. 93.9%, p < 0.005; R2, 85.7% vs. 98%, p = 0.07), with no difference in sensitivities (p > 0.05). In cases of absent extra-osseous soft tissue mass and present fracture site enhancement, the combined set showed improved accuracy (R1, 82.9-84.4% vs. 95.6-96.3%, p < 0.05; R2, 90.2-91.1% vs. 95.1-95.6%, p < 0.05) and specificity (R1, 68.3-72.9% vs. 92.7-95.8%, p < 0.005; R2, 83.0-85.4% vs. 97.6-98.0%, p = 0.07). Conclusion: Combining DWI with conventional MRI improved the diagnostic accuracy and specificity while retaining sensitivity for differentiating between pathologic and traumatic fractures from metastasis at extremities.

Quantitative Comparisons in $^{18}F$-FDG PET Images: PET/MR VS PET/CT ($^{18}F$-FDG PET 영상의 정량적 비교: PET/MR VS PET/CT)

  • Lee, Moo Seok;Im, Young Hyun;Kim, Jae Hwan;Choe, Gyu O
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.68-80
    • /
    • 2012
  • Purpose : More recently, combined PET/MR scanners have been developed in which the MR data can be used for both anatometabolic image formation and attenuation correction of the PET data. For quantitative PET information, correction of tissue photon attenuation is mandatory. The attenuation map is obtained from the CT scan in the PET/CT. In the case of PET/MR, the attenuation map can be calculated from the MR image. The purpose of this study was to assess the quantitative differences between MR-based and CT-based attenuation corrected PET images. Materials and Methods : Using the uniform cylinder phantom of distilled water which has 199.8 MBq of $^{18}F$-FDG put into the phantom, we studied the effect of MR-based and CT-based attenuation corrected PET images, of the PET-CT using time of flight (TOF) and non-TOF iterative reconstruction. The images were acquired from 60 minutes at 15-minute intervals. Region of interests were drawn over 70% from the center of the image, and the Scanners' analysis software tools calculated both maximum and mean SUV. These data were analyzed by one way-anova test and Bland-Altman analysis. MR images are segmented into three classes(not including bone), and each class is assigned to each region based on the expected average attenuation of each region. For clinical diagnostic purpose, PET/MR and PET/CT images were acquired in 23 patients (Ingenuity TF PET/MR, Gemini TF64). PET/CT scans were performed approximately 33.8 minutes after the beginnig of the PET/MR scans. Region of interests were drawn over 9 regions of interest(lung, liver, spleen, bone), and the Scanners' analysis software tools calculated both maximum and mean SUV. The SUVs from 9 regions of interest in MR-based PET images and in CT-based PET images were compared. These data were analyzed by paired t test and Bland-Altman analysis. Results : In phantom study, MR-based attenuation corrected PET images generally showed slightly lower -0.36~-0.15 SUVs than CT-based attenuation corrected PET images (p<0.05). In clinical study, MR-based attenuation corrected PET images generally showed slightly lower SUVs than CT-based attenuation corrected PET images (excepting left middle lung and transverse Lumbar) (p<0.05). And percent differences were -8.01.79% lower for the PET/MR images than for the PET/CT images. (excepting lung) Based on the Bland-Altman method, the agreement between the two methods was considered good. Conclusion : PET/MR confirms generally lower SUVs than PET/CT. But, there were no difference in the clinical interpretations made by the quantitative comparisons with both type of attenuation map.

  • PDF

Study on Oxidation and Coercivity of Nd2Fe14B Compound Crystal (Nd2Fe14B 화합물 결정의 산화 및 보자력에 관한 연구)

  • Kwon, H.W.;Yu, J.H.
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.3
    • /
    • pp.85-90
    • /
    • 2012
  • Oxidation of the $Nd_2Fe_{14}B$ compound crystal and its effect on the coercivity of the fine $Nd_2Fe_{14}B$ crystal particles were investigated. Oxidation kinetics of the $Nd_2Fe_{14}B$ compound crystal was investigated using an excessively grown $Nd_2Fe_{14}B$ grains in the $Nd_{15}Fe_{77}B_8$ alloy ingot. Oxidation of the $Nd_2Fe_{14}B$ compound crystal occurred by dissociation of the phase into multi-phase mixture of ${\alpha}$-Fe, $Fe_3B$, and Nd oxides. Oxidation rate of the $Nd_2Fe_{14}B$ compound crystal showed no dependence on the crystallographic direction. The oxidation reaction was modeled according to simple linear relationship. Activation energy for the oxidation of $Nd_2Fe_{14}B$ compound crystal was calculated to be approximately 26.8 kJ/mol. Fine $Nd_2Fe_{14}B$ crystal particles in near single domain size was prepared by ball milling of the HDDR-treated $Nd_{15}Fe_{77}B_8$ alloy, and these particles were used for investigating the effect of oxidation on the coercvity. The near single domain size $Nd_2Fe_{14}B$ crystal particles (${\fallingdotseq}0.3\;{\mu}m$) had high coercivity over 9 kOe. However, the coercivity was radically reduced as the temperature increased in air (<2 kOe at $200^{\circ}C$). This radical coercivity reduction was attributed to the soft magnetic phases, ${\alpha}$-Fe and $Fe_3B$, which were formed on the surface of the fine particles due to the oxidation.

Diagnostic Value of MRI in Schwannoma (신경초종 진단에 있어 자기공명영상촬영(MRI)의 진단적 가치)

  • Kim, Jeung Il;Kim, Um Ji;Moon, Tae Yong;Lee, In Sook;Song, You Seon;Choi, Kyung Un
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.20 no.2
    • /
    • pp.60-65
    • /
    • 2014
  • Purpose: To diagnose soft tissue tumor, such as lipoma and Schwannoma, magnetic resonance imaging (MRI) is sufficient in most cases. However, various characteristics are found in MRI images of Schwannoma, thus other type of tumors are often misdiagnosed as Schwannoma with MRI images. In this study, we evaluate the diagnostic value of specific MRI findings of Schwannoma. Materials and Methods: From January 2002 to May 2013, 104 patients who are suspected as Schwannoma rith MRI images are included in data, and the final diagnosis is confirmed with biopsy. Patients are divided into group 1 and group 2 who are confirmed as Schwannoma and other disease with biopsy, respectively. Results: 92 patients were diagnosed as Schwannoma (group 1) and 12 patients were diagnosed as other disease (group 2). We investigate the diagnostic value of specific MRI findings of Schwannoma. 41 patients of group 1 (45%) and 0 patients of group 2 (0%) showed target sign, 47 patients of group 1 (51%) and 2 patients of group 2 (17%) showed fascicular sign, 44 patients of group 1 (48%) and 5 patients of group 2 (42%) showed fat split sign, 28 patients of group 1 (30%) and 1 patients of group 2(9%) showed nerve entering and exiting sign, and 8 patients of group 1 (9%) and 6 patients of group 2 (50%) showed none of four specific findings on their MRI images. 52 patients of group 1 (57%) and 5 patients of group 2 (42%) have tumors on the pathway of nerve. Target sign could be considered as the best diagnostic value of the sign we investigate (p<0.05). Conclusion: Although specific MRI findings have powerful diagnostic value, patients are often misdiagnosed as Schwannoma with MRI findings. Therefore, if patients who are suspected as Schwannoma based on MRI findings have no target sign on their MRI images, we should consider the possibility of other disease.