A Study of the Effect of Acoustic Noise Attenuator on Auditory Functional MRI

소음 감쇠기를 이용한 청각의 뇌기능 자기공명영상

  • Kim, S.H. (Dept. of Medical & Biological Engineering, Graduate, Kyungpook National University) ;
  • Kim, I.S. (Dept. of Medical & Biological Engineering, Graduate, Kyungpook National University) ;
  • Lee, J.J. (Dept. of Medical & Biological Engineering, Graduate, Kyungpook National University) ;
  • Park, J.A. (Dept. of Medical & Biological Engineering, Graduate, Kyungpook National University) ;
  • Lee, Y.J. (Dept. of Medical & Biological Engineering, Graduate, Kyungpook National University) ;
  • Yeo, J.R. (Dept. of Medical & Biological Engineering, Graduate, Kyungpook National University) ;
  • Bae, S.J. (Dept. of Medical & Biological Engineering, Graduate, Kyungpook National University) ;
  • Lee, S.H. (Dept. of Otolaryngology, College of Medicine, Kyungpook National University) ;
  • Chang, Y. (Dept. of Medical & Biological Engineering, Graduate, Dept. of Diagnostic Radiology, College of Medicine, Kyungpook National University)
  • 김상환 (경북대학교 대학원 의용생체공학과) ;
  • 김인성 (경북대학교 대학원 의용생체공학과) ;
  • 이재준 (경북대학교 대학원 의용생체공학과) ;
  • 박지애 (경북대학교 대학원 의용생체공학과) ;
  • 이영주 (경북대학교 대학원 의용생체공학과) ;
  • 여종록 (경북대학교 대학원 의용생체공학과) ;
  • 배성진 (경북대학교 대학원 의용생체공학과) ;
  • 이상흔 (경북대학교 의과대학 이비인후과학교실) ;
  • 장용민 (경북대학교 대학원 의용생체공학과, 의과대학 진단방사선과학교실)
  • Published : 2005.12.01

Abstract

Purpose : To evaluate the usefulness of acoustic noise attenuator on auditory fMRI examination. Materials and methods : The acoustic noise attenuator consists of mask, earmuff and silicon earplug. The soft polyurethane sheet and polyurethane form , which has a good soundproof characteristic were used for mask and earmuff. Auditory fMRI experiments of 500 Hz pure tone stimulation were performed in three different cases; first all of mask, earmuff and earplug, secondly earmuff and earplug only and finally without attenuator in 4 normal hearing volunteers. For data acquisition, BOLD MR imaging technique was employed at a 1.5T MR scanner equipped with high performance gradient system. The raw data were analyzed using a SPM-99 analysis software and the activation maps were obtained. Results : In case of all items of acoustic attenuator used, the results revealed that activation was focused on primary auditory area. When only earmuff and earplug were used, the results showed that the activation spread over primary auditory and secondary associative areas. Last, when no device used, only weak activation was observed on the right auditory cortex. Conclusion : It is expected that the acoustic noise attenuator, which consists of earplugs, earmuffs and mask, is a very useful device in auditory fMRI study.

목적 : 청각의 뇌기능 영상 검사 시 소음 감쇠기의 유용성을 알아보고자 하였다. 대상 및 방법 : 소음 감쇠기는 실리콘 이어폰, 귀마개 그리고 마스크로 구성하였다. 마스크와 귀마개는 방음효과가 크다고 알려져 있는 부드러운 재질의 폴리우레탄 시트와 폴리우레탄 폼을 사용하여 제작하였다. 500 Hz의 순음 자극에 대한 청각의 뇌기능 자기공명영상 실험은 4명의 지원자를 대상으로 다음의 세가지 경우로 구별하여 시행하였다: 첫째, 마스크와 귀마개, 이어폰을 모두 착용한 경우, 둘째, 귀마개와 이어폰만을 착용한 경우 그리고 마지막으로 소음 감쇠기를 착용하지 않은 경우 이다. 데이터 획득을 위하여 고성능 경사자계 시스템이 갖추어진 1.5 T 자기공명영상장치에서 BOLD 자기공명 영상기법을 사용하였다. 영상 데이터는 SPM 99 분석프로그램을 이용하여 분석하여 활성화 지도를 획득하였다. 결과 : 소음감쇠기의 모든 구성요소를 사용한 경우 활성화는 주로 일차 청각중추에서만 집중되어 나타나는 결과를 얻었다. 귀마개와 이어폰만을 착용했을 때는 청각의 뇌 활성화 영역이 일차 청각중추와 이차 청각 영역에 분산되어 나타는 결과를 얻었으며 마지막으로 소음감쇠기를 사용하지 않은 경우 청각영역이 오른쪽의 일부만이 활성화 되었다. 결론 : 마스크, 귀마개, 이어폰으로 구성된 소음 감쇠기는 청각의 뇌기능 영상 검사 시 매우 유용할 것으로 기대된다.

Keywords