• Title/Summary/Keyword: Soft contact

Search Result 364, Processing Time 0.021 seconds

Fabrication of Superhydrophobic Film with Uniform Structures Using Two Step Lithography and Nanosilica Coating (Two step lithography와 나노 실리카 코팅을 이용한 초발수 필름 제작)

  • Yu, Chaerin;Lee, Dong-Weon
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.251-255
    • /
    • 2019
  • We propose a two-step lithography process to minimize edge-bead issues caused by thick photoresist (PR) coating. In the conventional PR process, the edge bead can be efficiently removed by applying an edge-bead removal (EBR) process while rotating the silicon wafer at a high speed. However, applying conventional EBR to the production of desired PR mold with unique negative patterns cannot be used because a lower rpm of spin coating and a lower temperature in the soft bake process are required. To overcome this problem, a two-step lithography process was developed in this study and applied to the fabrication of a polydimethylsiloxane (PDMS) film having super-hydrophobic characteristics. Following UV exposure with a first photomask, the exposed part of the silicon wafer was selectively removed by applying a PR developer while rotating at a low rpm. Then, unique PR mold structures were prepared by employing an additional under-exposure process with a second mask, and the mold patterns were transferred to the PDMS. Results showed that the fabricated PDMS film based on the two-step lithography process reduced the height difference from 23% to 5%. In addition, the water contact angle was greatly improved by spraying of hydrophobic nanosilica on the dual-scaled PDMS surface.

Digital Technology Practices and Vaccine Campaign in Korea: International Perceptions on Health Diplomacy amid COVID-19 Crisis

  • Tahira, Iffat
    • Journal of Contemporary Eastern Asia
    • /
    • v.21 no.2
    • /
    • pp.27-46
    • /
    • 2022
  • The purpose of this study is two-fold: first, to discuss the concept of health diplomacy and the Korean government's response to contain the COVID-19 pandemic; second, to assess and compare assumptions of variances about foreigners' perceptions of how Korea is leveraging digital technology in battling the coronavirus spread, and its vaccine campaign; through the lenses of Chinese, Filipino, and Pakistani foreign nationals who are currently living in Korea. A total of 219 foreigners responded to the survey. The collected data were analyzed as percentages, mean averages, t-test, and ANOVA for statistical analysis. Results show that Korea is utilizing its digital technology practices and vaccine campaign in battling the pandemic through efforts of health diplomacy. ANOVA indicated significant results and assumptions of variance across three ethnic groups showing the Pakistani population had higher mean scores than the Chinese and Filipino about Korea's health diplomacy during the pandemic. This study contributes to the literature on Korea's digital technology practices and vaccine campaigns amidst the COVID-19 pandemic by promoting its image through health diplomacy efforts. It projects the country's soft image on a global scale, to save the lives of locals and foreign nationals, by providing insights into health diplomacy in Korea.

Development and Structural Design of Textile Touch Sensor Easily Implemented (구현방식이 용이한 텍스타일 터치센서 개발 및 구조적 설계)

  • Kim, Ji-seon;Park, Jinhee;Kim, Jooyoung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.1
    • /
    • pp.168-179
    • /
    • 2021
  • This study presents and develops a textile type touch sensor structural design that is easy to implement. First, the design of the touch sensor circuit finds the size of the switch with the easiest finger contact and selects a structure with a long circuit with the lowest resistance value. An experiment is performed on a change in an electrostatic capacitance value that accompanies the distance on the electrode and the magnitude of the electrode area of the structure; however, the structure having the distance on the electrode and the large electrode area shows the best resistance change. The laundry assessment was conducted three times at a time and ten times at a time with an average standard deviation less than one ohm, with little change in resistance. Consequently, there were no problems with durability and performance for laundry. Finally, in the bending evaluation, the difference in resistance can be seen between 1-2 ohms and was developed as a smart wearable in the future; in addition, there was no problem as a difference in resistance can be seen between 1 and 2 ohms.

Stress waves transmission from railway track over geogrid reinforced ballast underlain by clay

  • Fattah, Mohammed Y.;Mahmood, Mahmood R.;Aswad, Mohammed F.
    • Structural Monitoring and Maintenance
    • /
    • v.9 no.1
    • /
    • pp.1-27
    • /
    • 2022
  • Extensive laboratory tests were conducted to investigate the effect of load amplitude, geogrid position, and number of geogrid layers, thickness of ballast layer and clay stiffness on behavior of reinforced ballast layer and induced strains in geogrid. A half full-scale railway was constructed for carrying out the tests, the model consists of two rails 800 mm in length with three wooden sleepers (900 mm × 10 mm × 10 mm). The ballast was overlying 500 mm thickness clay in two states, soft and stiff state. Laboratory tests were conducted to investigate the response of the ballast and the clay layers where the ballast was reinforced by a geogrid. Settlement in ballast and clay, soil pressure and pore water pressure induced in the clay were measured in reinforced and unreinforced ballast cases. It was concluded that the effect of frequency on the settlement ratio is almost constant after 500 cycles. This is due to that the total settlement after 500 cycles, almost reached its peak value, which means that the ballast particles become very close to each other, so the frequency is less effective for high contact particles forces. The average maximum vertical stress and pore water pressure increased with frequency.

A study on Monovision of Fitting soft contact lenses for College students (대학생에게 유도된 소프트 콘택트렌즈 모노비전에 관한 연구)

  • Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.181-188
    • /
    • 2004
  • Monovision is defined as correcting one eye for distance vision and the other eye for near vision. Single-vision contact lenses are used for each eye. The patient selectively suppresses one eye while using the other eye. This study was performed to measure binocular function and patient satisfaction with monovision induced by adding +3.00D to spectacle prescription for distance vision in nonpresbyopic students. This study comprised 144 nonpresbyopic students with monovision induced by adding +3.00D to spectacle prescription. Monovision was induced by undercorrecting the nondominant eye by adding 3.00 diopters for near vision and correcting the dominant eye with emmetropia for distance vision. For research of the binocular function on Monovision. This study was tested the obstacle course, water pouring test, catching and throwing, bead classification including the stereopsis test. These tests were comparative to the normal binocular state. As a results, the stereopsis have a significant reductions in Monovision. There was no significantly difference between monovision group and control group in monovision exercise (obstacle course, water pouring test, catching and throwing, and bead sorting) at near and distance. This study indicates that monovision is an effective and reasonable therapeutic modality for correcting presbyopia. By the application of above methods, this study could be used the student for the practical practice and understand on the Monovison.

  • PDF

Use of Piggyback Contact Lens System to GP Lens Wearers (GP렌즈 착용자에게 피기백 콘택트렌즈 시스템의 적용)

  • Kim, Yong Gil;Kim, Soo Hyun;Kim, Jai Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.47-53
    • /
    • 2010
  • Purpose: This study was performed to achieve an acceptable piggyback fit utilizing each subject's own GP lenses, in subjects with regular low myopic astigmatism. Methods: A randomized, prospective study of 15 subjects with the diagnosis of low myopic astigmatism was conducted. Nine subjects were female and 6 were male, and mean age was: 23.73${\pm}$1.68 years. Subjects were evaluated before participate on this study and then also evaluated with period of at two hours and two weeks after obtaining their lenses. All subjects were submitted to the following tests: measurement of comfort level by means of the analogical visual scale, best corrected visual acuity and over-refraction at distance. contrast sensitivity and stereo acuity. After evaluating the fit of plano soft lens, we applied each subject's own GP lens on top. Results: Vision, visual performance and satisfaction of piggyback contact lens system were stable, if not improved, for the 15 subjects when the data was compared to the patients' wear of rigid gas permeable contact lenses. Fit with a piggyback system had the same or improved comfort, visual acuity and contrast sensitivity compared to previous GP lens wear alone. The visual acuity, contrast sensitivity and stereo acuity did not show differences in relation to the studied lens type. Conclusions: These results suggest that it is possible to achieve a successful piggyback lens fitting utilizing a patient's own GP lens. The piggyback lens system satisfied the visual performance and visual requirements of this subject with GP lens alone for the correction of low myopic astigmatism.

Viscosity and Wettability of Carboxymethylcellulose(CMC) solutions and Artificial Saliva (Carboxymethylcellulose(CMC) 용액과 인공 타액의 점도와 습윤성)

  • Park, Moon-Soo;Kim, Young-Jun
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 2007
  • Destruction of oral soft and hard tissues and resulting problems seriously affect the life quality of xerostomic patients. Although artificial saliva is the only regimen for xerostomic patients with totally abolished salivary glands, currently available artificial salivas give restricted satisfaction to patients. The purpose of this study was to contribute to the development of ideal artificial saliva through comparing viscosity and wettability between CMC solutions and human saliva. Commercially-available CMC is dissolved in simulated salivary buffer (SSB) and distilled deionized water (DDW). Various properties of human whole saliva, human glandular saliva, and a CMC-based saliva substitutes known as Salivart and Moi-Stir were compared with those of CMC solutions. Viscosity was measured with a cone-and-plate digital viscometer at six different shear rates, while wettability on acrylic resin and Co-Cr alloy was determined by the contact angle. The obtained results were as follows: 1. The viscosity of CMC solutions was proportional to CMC concentration, with 0.5% CMC solution displaying similar viscosity to stimulated whole saliva. Where as a decrease in contact angle was found with increasing CMC concentration. 2. The viscosity of human saliva was found to be inversely proportional to shear rate, a non-Newtonian (pseudoplastic) trait of biological fluids. The mean viscosity values at various shear rates increased as follows: stimulated parotid saliva, stimulated whole saliva, unstimulated whole saliva, stimulated submandibular-sublingual saliva. 3. Contact angles of human saliva on the tested solid phases were inversely correlated with viscosity, namely decreasing in the order stimulated parotid saliva, stimulated whole saliva, unstimulated whole saliva, stimulated submandibular-sublingual saliva. 4. Boiled CMC dissolved in SSB (CMC-SSB) had a lower viscosity than CMC-SSB (P < 0.01 at shear rate of $90s^{-1}$). 5. For human saliva, contact angles on acrylic resin were significantly lower than those on Co-Cr alloy (P < 0.01). 6. Comparing CMC solutions with human saliva, the contact angles between acrylic resin and human saliva solutions were significantly lower than those between acrylic resin and CMC solutions, including Salivart and Moi-Stir (P <0.01). The effectiveness of CMC solutions in terms of their rheological properties was objectively confirmed, indicating a vital role for CMC in the development of effective salivary substitutes.

The Deposition of Tear Protein according to Soft Lens Materials and The Cleaning Efficacy of Multi-purpose Solution according to the Surfactant Types (소프트렌즈 재질 별 누액단백질 침착 및 계면활성제 종류에 따른 다목적용액의 세척효율)

  • Park, Mijung;Kwon, Young Dae;Lee, Wang Jae;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.179-188
    • /
    • 2014
  • Purpose: The present study was aimed to investigate the cleaning efficacy of multi-purpose solutions containing different types and content of surfactants and their effect on the visible light transmittance of soft lens. Methods: Soft lenses made of different materials (etafilcon A and hilafilcon B) were deposited tear proteins by using the artificial tear and then compared the resulting cleaning efficacy and visible light transmittance after cleaning the lens with 6 types of multi-purpose solutions containing different content of surfactants. Results: The cleaning efficacy of multi-purpose solutions was variously shown as approximately 23~43% according to the active concentration of surfactants and surface tension in multi-purpose solution when etafilcon A lens cleaned with rubbing. The highest cleaning efficacy was detected when cleaned with the multi-purpose solution containing hydrogen peroxide besides surfactant however, the amount of remaining protein was still high on the lens. After washed with multi-purpose solution, the visible light transmittance of lens was in 89.8 to 90.8%. The amount of protein deposited on hilafilcon B lens was very small compared with it on etafilcon A lens even though it was incubated in artificial tears for 7 days, which showed 5~10% of protein amount in etafilcon A lens and the decrease of visible light transmittance was also not significant. In case of rubbing with multi-purpose solution, the cleaning efficacy on hilafilcon B lens was in 45.4 to 67.4% however, the order of cleaning efficacy of multi-purpose solution was different from it on etafilcon A lens. The visible light transmittance of hilafilcon B lens has been restored to the level of new lens. Conclusions: From the result, it is concluded that the appropriate multi-purpose solution should be selected according to the lens material and the amount of protein deposit on the basis of understanding surfactants and active principle for proper care of protein deposit on soft lens and the cleaning with rubbing is more efficient for lens care regardless of manufacturer's guideline.

Analysis of Flavor Components of Coffee Beans in Polyethylene and Polypropylene Packaging Materials during Storage (원두커피 향미 성분의 폴리에틸렌과 폴리프로필렌 포장재에서의 저장 차이 분석)

  • Yu, Ha Kyoung;Lee, Seung Uk;Oh, Jae Young
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.23 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • Although the global coffee market is growing every year and the demand for coffee wrapping paper is increasing accordingly, research on the effect of PE material and PP material on the coffee aroma used in the sealant layer, which will directly contact the product, is lacking. In this study, we studied the change of aroma patterns and flavor materials by adding coffee to PP and PE pouches. In addition, we observed changes in aroma patterns depending on the temperature and the presence of the deoxidizer. As a result, it was found that the PP type packaging material was slightly better than the PE type packaging material, but the performance was hardly changed by the material. Rather, the change in the aroma pattern due to temperature was dominant rather than the material. It is ideal that refrigerated distribution ($4^{\circ}C$) is the best storage temperature and sales are done within a short period of time. Among the indicators, pyridine was the most suitable material to study and there are many data about pyridine. Therefore, it is expected that the results can be derived by using pyridine.

Effect of Everted(inside out) Silicone Hydrogel Lens on Corneal Topographical Changes (역방향으로 착용한 (inside out or everted) 실리콘 하이드로겔 렌즈가 각막형상 변화에 미치는 영향)

  • Kim, Soo-Hyun;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.389-394
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the corneal topographical changes associated with the wearing of everted silicone hydrogel soft lenses. Methods: The shape and fluorescein pattern of everted silicone hydrogel lenses were investigated. The subject wore the silicone hydrogel everted lenses overnight for 8 hours. Objective refractive error and corneal shape were evaluated at baseline, 1, 2, 3, 5, and 7 days after lens wearing and 1,2,3, and 4 days after discontinuation of lens wear. Results: The Fluorescein pattern of everted silicone hydrogel lenses was similar to the reverse geometry lenses with pressure profile. Objective refractive error(sphere power) and corneal refractive power were decreased and corneal shape had changed during the everted silicone hydrogel lenses wear and recovered during the 4 days of discontinuation. Subject experienced no discomfort associated with the everted silicone hydrogel lenses. Conclusions: It appears that everted silicone hydrogel lenses are capable of inducing significant changes in corneal topography, with overnight wear. Further study must be done to help understand these changes to develop a predictable and effective way of using soft contact lenses for corneal reshaping.