• Title/Summary/Keyword: Soft Surface

Search Result 970, Processing Time 0.026 seconds

A study on Surface Treatment of Dredged fill Ground (준설토의 표층처리에 관한 연구)

  • 정규향;이문수;이광찬;윤석군;오재화
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.569-574
    • /
    • 1999
  • In Soft ground of south-western coast of our country necessity of marine indutrial complex and container facility has been remarkable. Site construction for habor facility is one of the most urgent problems. Consolidation of dredged fill has become important task. In addition, volume change of dredged fill should be examined carefully. This study dealt with consolidation of dredged fill by PCDDF and in order to secure trafficability of heavy equipment for surface treatment should be studied.

  • PDF

Vortex-Shedding-Induced Dissipation of Waves Scattering against Surface-Piercing Vertical Thin Plates (수면에 거치된 수직 다중 판에 의한 산란에서 와류로 인한 파랑 에너지의 소멸)

  • Oh, Mi-Ran;Lee, Jung-Lyul
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.276-282
    • /
    • 2003
  • The breakwater of surface-piercing type has been developed mainly for application within bays or estuaries that are semi-protected from the direct impact of targe waves. Most of bays have soft foundation which is too weak to bear the weight of gravity type breakwater. (omitted)

  • PDF

Design of a Propagation Wave Type Microrobot for Moving on the Slippery Surface

  • Kim, Eui-Jin;Park, Jong-Hyeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2072-2077
    • /
    • 2003
  • Animal-like robots are serving an important role as a linkage between biology and engineering. So, in this paper, we aim to develop a biomimetic microrobot that mimics the locomotion mechanism of a gastropod. This microrobot has 3 DOF (x, y translation and rotation), and has small size, unlimited traveling range, high resolution and low cost. Its movement can be made using propagation wave that is generated by the controllable sinusoidal voltage source and piezoelectric effects. This soft motion that can be generated by propagation wave and piezoelectric mechanism would be useful for the motion on the slippery surface. So we modeled the propagation wave mechanism including piezoelectric effect and friction on the contact surface, and could know the velocity of the microrobot is dependent on the driving frequency, input voltage peak, propagation wavelength and surface friction coefficient. With these results we design the microrobot, and accomplish its fabrication and experimentation. The development of this microrobot shall be aimed to design an autonomous moving actuator like animal. Also it can be used from micromanipulation system technology to biology and medicine.

  • PDF

Vibro-Contact Analysis of AFM Tip on Polymer Surface (폴리머 표면측정을 위한 AFM 팁의 접촉-진동 해석)

  • Hong, Sang-Hyuk;Lee, Soo-Il
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.538-541
    • /
    • 2005
  • In tapping mode atomic force microscopy(TM-AFM). the vibro-contact response of a resonating tip is used to measure the nanoscale topology and other properties of a sample surface. However, the nonlinear tip-surface interact ions can affect the tip response and destabilize the tapping mode control. Especially it is difficult to obtain a good scanned image of high adhesion surfaces such as polymers and biomoleculars using conventional tapping mode control. In this study, theoretical and experimental investigations are made on the nonlinear dynamics and control of TM-AFM. To analyze the complex dynamics and control of the tapping tip, the classical contact models are adopted due to the surface adhesion. Also we report the surface adhesion is an additional important parameter to determine the control stability of TM-AFM. In addition, we prove that it is more adequate to use Johnson-Kendall-Roberts (JKR) contact model to obtain a reasonable tapping response in AFM for the soft and high adhesion samples.

  • PDF

Artificial Intelligence Engine for Numerical Analysis of Surface Waves (표면파의 수치해석을 위한 인공지능 엔진 개발)

  • Kwak Hyo-Gyoung;Kim Jae-Hong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.89-96
    • /
    • 2006
  • Nondestructive evaluation using surface waves needs an analytical solution for the reference value to compare with experimental data. Finite element analysis is very powerful tool to simulate the wave propagation, but has some defects. It is very expensive and high time-complexity for the required high resolution. For those reasons, it is hard to implement an optimization problem in the actual situation. The developed engine in this paper can substitute for the finite element analysis of surface waves propagation, and it accomplishes the fast analysis possible to be used in optimization. Including this artificial intelligence engine, most of soft computing algorithms can be applied on the special database. The database of surface waves propagation is easily constructed with the results of finite element analysis after reducing the dimensions of data. The principal wavelet-component analysis is an efficient method to simplify the transient wave signal into some representative peaks. At the end, artificial neural network based on the database make it possible to invent the artificial intelligence engine.

  • PDF

Changes in Optical and Surface Properties of Contaminated Soft Contact Lenses (표면 오염시 소프트콘택트렌즈의 재질에 따른 가시광선투과도 및 표면 변화)

  • Kim, Jungeun;Jung, Boyoung;Noh, Hyeran
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.83-89
    • /
    • 2012
  • Purpose: This article was to study the optical and surface properties of soft contact lenses (SCL) exposed to eye make-ups. Methods: Rates of the light transmission of etafilcon A (HEMA based hydrogel lens) and lotrafilcon B (silicone based hydrogel lens) exposed to four different cosmetics over time were investigated. After cleansed with multi-purpose solution (MPS), rates of the light transmission and surface change of lens that were exposed to the cosmetics for 7 consecutive days were analyzed. Results: Visible light transmissions of all lenses exposed to cosmetics decreased to 93.35% (HEMA based hydrogel lens) and 90% (silicone based hydrogel lens) compared with those of the fresh SCLs, such as 97.8% and 96.4%, respectively. It was found that cosmetic residues from powder eye shadow and mascara attached to the lenses were not removed completely when cleansed with MPS. Especially with silicone based hydrogel lens, we found a decrease in visible light transmission of the lens and noticeable particles on lens surface imaged by SEM. Conclusions: Depending on types of eye make-ups and contact lens materials, make-ups were not completely eliminated with current cleansing methods and that caused a decrease in optical property and a change in surface property of the lenses.

Tissue integration of zirconia and titanium implants with and without buccal dehiscence defects

  • Lim, Hyun-Chang;Jung, Ronald Ernst;Hammerle, Christoph Hans Franz;Kim, Myong Ji;Paeng, Kyeong-Won;Jung, Ui-Won;Thoma, Daniel Stefan
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.3
    • /
    • pp.182-192
    • /
    • 2018
  • Purpose: The purpose of the present study was to validate an experimental model for assessing tissue integration of titanium and zirconia implants with and without buccal dehiscence defects. Methods: In 3 dogs, 5 implants were randomly placed on both sides of the mandibles: 1) Z1: a zirconia implant (modified surface) within the bony housing, 2) Z2: a zirconia implant (standard surface) within the bony housing, 3) T: a titanium implant within the bony housing, 4) Z1_D: a Z1 implant placed with a buccal bone dehiscence defect (3 mm), and 5) T_D: a titanium implant placed with a buccal bone dehiscence defect (3 mm). The healing times were 2 weeks (one side of the mandible) and 6 weeks (the opposite side). Results: The dimensions of the peri-implant soft tissue varied depending on the implant and the healing time. The level of the mucosal margin was located more apically at 6 weeks than at 2 weeks in all groups, except group T. The presence of a buccal dehiscence defect did not result in a decrease in the overall soft tissue dimensions between 2 and 6 weeks ($4.80{\pm}1.31$ and 4.3 mm in group Z1_D, and $4.47{\pm}1.06$ and $4.5{\pm}1.37mm$ in group T_D, respectively). The bone-to-implant contact (BIC) values were highest in group Z1 at both time points ($34.15%{\pm}21.23%$ at 2 weeks, $84.08%{\pm}1.33%$ at 6 weeks). The buccal dehiscence defects in groups Z1_D and T_D showed no further bone loss at 6 weeks compared to 2 weeks. Conclusions: The modified surface of Z1 demonstrated higher BIC values than the surface of Z2. There were minimal differences in the mucosal margin between 2 and 6 weeks in the presence of a dehiscence defect. The present model can serve as a useful tool for studying peri-implant dehiscence defects at the hard and soft tissue levels.

Microbe Pollution Condition on Soft Contact Lenses (소프트 콘택트렌즈에서의 미생물 오염양상)

  • Han, Sun-Hee;Park, Sung-Min;Yu, Tae-Shick
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.313-321
    • /
    • 2005
  • To know the pollution level concerning the microbes contamination condition in soft contact lenses, 2 experiments were operated with different methods. Firs experiment, we observed lenses surfaces through a scanning electronic microscope after pollution sort contact lenses with the suspensions of Staphylococcus aureus, Pseudomonas aeruginosa and Entrobacter aerogenes which can be major bacteria causing keratitis as wearing on soft contact lenses. As 1 hour after pollution with the soft contact lenses, we observed that many bacteria adhered to the lenses, and the pollution condition got worse with passing time increase(2, 4, 6, 12, and 24 hours, respectively). At 12 hours lapse of polluting soft contact lenses with P. aeruginosa, some bacteria adhered to the lenses. And as 24 hours lapsed after pollution soft lenses with E. aerogenes, bacteria adhered to them, and atypical substance was observed some of the surface of lenses. Second experiment, we observed the microbe pollution condition in soft contact lenses by let 21 people in twenties(men & women), who doesn't eye disorders, wear soft contact lenses during 4 hours. As the result, many kinds of bacterium and fungus were observed, and especially, the bacteria could be identified with their colors and the shapes of colony, so we found that single type, two types, and three types of bacteria adhered to their lenses.

  • PDF

Analysis on the Safety of Structure and Economics of Replacement Method Using Rock Debris in the Soft Ground - Case Study of Miho Stream Crossing Road in Cheongju City (연약지반 암버럭 치환공법의 구조물 안정성과 경제성 분석 - 청주시 미호천 횡단도로를 대상으로)

  • Heo, Kang Kug;Park, Hyung Keun;Ahn, Byung Chul;Min, Byeong Uk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.705-713
    • /
    • 2016
  • For the soft ground construction, the factors not considered in the design stage occurs in the construction stage so that they cause the increase of the construction cost due to the structural stability and the design change. The subject of the study is the construction section of the industrial complex access road made in the Ochang region of Chungcheongbuk-do. The study is concerned with selecting the soft ground handling method such as the replacement method using rock debris and the surcharge reflecting the service load as the soft ground handling measure and analyzing the effect of reducing the construction cost with the stability of structures and the reduction of the construction period. The soft ground in the study section consists of sandy and cohesive soil and is 2.4m to 5.5m deep. It is distributed unevenly between the 1.5m to 5.9m stratums under the ground surface. Settlement is not serious, but the future uneven settlement and difference are expected so that the future settlement behavior is estimated by analyzing the site measurement results after the soft ground treatment. Moreover, in consideration of the regional characteristics and economic efficiency, soil with good quality is replaced with rock debris as the replacement material so that 29% of the construction cost is reduced due to the increase of stability and the reduction of duration. If the estimation of the dispersion of the pore water pressure within the dam body and the change of the underground water level and the relation of the actually measured soft ground with consolidation is studied further on the basis of the study, it is expected that the behavior of the soft ground will be correctly estimated in various site conditions.