• Title/Summary/Keyword: Socket Interface Pressure

Search Result 7, Processing Time 0.023 seconds

Relationships Between the Transfemoral Socket Interface Pressure and Myoelectric Signal of Residual Limb During Gait

  • Hong, J.H.;Lee, J.Y.;Chu, J.U.;Lee, J.Y.;Mun, M.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1070-1073
    • /
    • 2002
  • The biomechanical interaction between the stump and the prosthetic socket is critically important to achieve close-to-normal ambulation. Many investigators suggested that the pressure changes during gait of transfemoral amputees are closely related to the prosthetic alignment, the socket shape, the stump size, and the residual muscle activity. The effects of the prosthetic alignment, the socket shape, and the stump size on the interface pressure were investigated previously. However, there is no report how the residual muscle activities in the transfemoral stump affect the socket interface pressure characteristics during gait. Since designs of socket fur lower limb amputees need to consider the socket interface pressure characteristics, the interface pressure patterns by the residual muscle activities during gait should be investigated. In this study, myoelectric signals (MES) and socket interface pressure in residual limb of transfemoral amputees were measured during the stance and swing phases of gait. For the purpose, specially designed quadrilateral sockets that MES electrodes could be instrumented were fabricated. A total of two transfemoral amputees were participated in the experiments. The measured temporal MES amplitude and interface pressure in knee flexor (biceps femoris) and extensor (rectus femoris) had significant correlations (P < 0.05). Based on the test results, It was suggested that the residual muscle activity of transfemoral amputees stump is an important factor affecting socket pressure changes during walk.

  • PDF

Pressure Distribution in Stump/Socket Interface in Response to Socket Flexion Angle Changes in Trans-Tibial Prostheses With Silicone Liner

  • Kang, Pil;Kim, Jang-Hwan;Roh, Jung-Suk
    • Physical Therapy Korea
    • /
    • v.13 no.4
    • /
    • pp.71-78
    • /
    • 2006
  • This study examined the effects of socket flexion angle in trans-tibial prosthesis on stump/socket interface pressure. Ten trans-tibial amputees voluntarily participated in this study. F-socket system was used to measure static and dynamic pressure in stump/socket interface. The pressure was measured at anterior area (proximal, middle, and distal) and posterior area (proximal, middle, and distal) in different socket flexion angles ($5^{\circ}$, $0^{\circ}$, and $10^{\circ}$). Paired t-test was used to compare pressure differences in conventional socket flexion angle of $5^{\circ}$ with pressures in socket flexion angles of $0^{\circ}$ and $10^{\circ}$ (${\alpha}$=.05). Mean pressure during standing in socket flexion angle of $10^{\circ}$ decreased significantly in anterior middle area (19.7%), posterior proximal area (10.4%), and posterior distal area (16.3%) compared with socket flexion angle of $5^{\circ}$. Mean pressure during stance phase in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (19.3%) and decreased significantly in anterior distal area (19.7%) compared with socket flexion angle of $5^{\circ}$. Mean pressure during stance phase in socket flexion angle of $10^{\circ}$ decreased significantly in anterior proximal area (19.6%) and increased significantly in anterior distal area (8.2%) compared with socket flexion angle of $5^{\circ}$. Peak pressure during gait in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (23.0%) compared with socket flexion angle of $5^{\circ}$ and peak pressure during gait in socket flexion angle of $10^{\circ}$ decreased significantly in anterior proximal area (22.7%) compared with socket flexion angle of $5^{\circ}$. Mean pressure over 80% of peak pressure ($MP_{80+}$) during gait in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (23.9%) and decreased significantly in anterior distal area (22.5%) compared with socket flexion angle of $5^{\circ}$. $MP_{80+}$ during gait in socket flexion angle of $10^{\circ}$ decreased significantly in anterior distal area (34.1%) compared with socket flexion angle of $5^{\circ}$. Asymmetrical pressure change patterns in socket flexion angle of $0^{\circ}$ and $10^{\circ}$ were revealed in anterior proximal and distal region compared with socket flexion angle of $5^{\circ}$. To provide comfortable and safe socket for trans-tibial amputee, socket flexion angle must be considered.

  • PDF

Socket Pressure Distribution of the Uni-Lateral Trans-Femoral Amputee with a Suction Socket (흡착식 소켓을 착용한 일측 대퇴절단환자의 소켓내부압력분포)

  • Chang, Y.H.;Kim, Y.H.;Yang, G.T.;Lim, S.H.;Mun, M.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.249-252
    • /
    • 1997
  • A study on static and dynamic socket pressure distributions on a trans-femoral amputee with a suction socket was performed in order to assess an optimal socket fitting and function. Even for the amputee's static neutral position, pressure concentrations were observed in the lateral, medial, and posterior planes of the socket. During free walking, a significant movement of pressure concentration areas was observed. Large socket pressure was observed in the lateral, medial-anterior and posterior walls during mid-stance or push-off period. Socket pressure measurement will be one of the good tool to determine the optimal socket-limb interface.

  • PDF

Socket Pressure Distribution of the Uni-Lateral Trans-Femoral Amputee with a Suction Socket (흡착식 소켓을 착용한 일측 대퇴절단환자의 소켓내부압력분포)

  • Jang, Yun-Hui;Yang, Gil-Tae;Im, Song-Hak;Mun, Mu-Seong;Kim, Yeong-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.417-422
    • /
    • 1998
  • The study was explored socket pressure distributions on a trans-femoral amputee with a suction socket in static and dynamic situations. Even when the amputee stood in the anatomically neutral position, significant pressure concentrations were observed in the lateral, medial, and posterior planes of the socket. During free level walking, a significant shifting pattern of pressure concentration areas was observed. High socket pressure was observed in the lateral, medial-anterior and posterior walls during mid-stance or push-off period. Socket pressure measurement will be one of the good tool to determine the optimal socket-limb interface.

  • PDF

Influence on amputee gait by the ankle joint alignment (발목관절 조절각도가 절단환자의 보행에 미치는 영향)

  • Kim, Y.H.;Yang, G.T.;Lim, S.H.;Chang, Y.H.;Mun, M.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.369-372
    • /
    • 1997
  • Socket pressure distributions with gait analyses of a transfemoral and a transtibial prostheses were measured in order to assess an optimal socket fitting and unction. Ankle joint was aligned by the neutral and the dorsi/plantar flexed positions. Compared to dorsi and plantar flexed positions of ankle joint, cadence and walking speed increased with the neutral ankle joint alignment. Other gait parameters were close to the normative data with the neutral ankle joint alignment. For the transfemoral amputee, dorsiflexed alignment of the ankle joint created high pressure on the lateral aspect of the socket, on the other hand, plantarflexed alignment resulted in increased pressure on the medial aspect of the socket. For the transtibial amputee, dorsiflexed alignment of the ankle resulted in high pressure on the antero-lateral aspect of the socket during mid-stance, but plantarflexion of the ankle joint showed slight increases in pressure at the same location in the socket. The present study clearly demonstrated that malalignment of a prosthesis results in localized increasing pressure within the socket. Proper alignment of the prosthesis is required in order to acquire an appropriate socket-limb interface as well as the proper gait.

  • PDF

Influence on Amputee Gait by the Ankle Joint Alignment (발목관절 조절각도가 절단환자의 보행에 미치는 영향)

  • Jang, Yun-Hui;Yang, Gil-Tae;Im, Song-Hak;Mun, Mu-Seong;Kim, Yeong-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.403-416
    • /
    • 1998
  • Socket pressure distributions with gait analysis of a trnsfemoral and a transtibial prostheses were measured in order to assess an optimal socket fitting and function. Ankle joint was aligned by the neutral and the dorsi/plantar flexed positions. Compared to dorsi and plantar flexed positions of ankle joint, cadence and walking speed increased with the neutral ankle joint alignment. Other gait parameters were close to the normative data with the neutral ankle joint alignment. For the transfemoral amputee, dorsiflexed alignment of the ankle joint created high pressure on the lateral aspect of the socket, on the other hand, plantarflexed alignment resulted in increased pressure on the medial aspect of the socket. For the transtibial amputee, dorsiflexed alignment of the ankle resulted in high pressure on the antero-lateral aspect of the socket during mid-stance, but apltarflexion of the ankle joint showed slight increases in pressure at the same location in the socket. The present study clearly demonstarted that malalignment of a prosthesis results in localized increasesing pressure within the socket. Proper slignment of the prosthesis is required in order to acquire an appropriate socket-limb interface as well as the proper gait.

  • PDF

A Study of Service Middleware for Application Based on USN/RFID/GPS (USN/RFID/GPS 응용을 위한 서비스 미들웨어 연구)

  • Moon, Kyeung-Bo;Lee, Chang-Young;Kim, Do-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1284-1288
    • /
    • 2008
  • Recently, there is increasing the development requirement of middleware and interface for GPS(Global Positioning System), RFID(Radio Frequency IDentification), sensor networks. GPS supports a useful location based service. RFID supports products logistic and distribution services through the identification. A sensor network collects a context information, such as humidity, temperature and atmospheric pressure. This paper implements and verifies a integrated service middleware for supporting efficiently process of sensing data collected from RFID, GPS and sensor network. This middleware have the temporary store function, the redundancy exclusion function, certification function, the classification function and the database storage function. Additionary, this middleware connects with low-level adaptor using socket interface and supports the high-level application services using database connection. Therefore, user can develop easily various many ubiquitous application system using proposed middleware instead of each RFID middleware, GPS middleware and, middleware based on sensor network.