• Title/Summary/Keyword: Snubbers

Search Result 45, Processing Time 0.028 seconds

Development of Wire Rope Snubbers (Wire Rope형 진동완충장치 개발)

  • Park, Jong-Beom;An, Yong-Ho;Bae, Byung-Hong;Kim, Min-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.334-336
    • /
    • 1999
  • Piping systems of the power generating stations have been generally protected by hydraulic and mechanical snubbers which can allow large displacements arising from temperature change while those can reduce or absorb stresses due to vibrations. However these snubbers require amounts of budget for maintenance or replacement because of the leakage, lubrication and finally short life cycle. Recently the snubbers consisted of wire rope have been proved to reduce vibrations of piping systems. While the wire rope snubbers are free of maintenance such as leakage and lubrication imported price are so high. Now it is necessary to design. manufacture and certificate these wire rope snubbers.

  • PDF

Design of Wire Rope snubbers (Wire Rope형 진동완충장치 설계)

  • Park, Jong-Beom;Yoon, Gi-Gab;Bae, Byung-Hong;Lee, Sang-Guk;Lee, Seung-Hak
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1192-1197
    • /
    • 2000
  • Piping systems of the power generating stations have been generally protected by hydraulic and mechanical snubbers which can allow large displacements arising from temperature change while those can reduce or absorb stresses due to vibrations. However these snubbers require amounts of budget for maintenance or replacement because of the leakage, lubrication and finally short life cycle. Recently the snubbers consisted of wire rope have been proved to reduce vibrations of piping systems. While the wire rope snubbers are free of maintenance such as leakage and lubrication, imported price are so high. Now it is necessary to design, manufacture and certificate these wire rope snubbers.

  • PDF

Design Optimization for High Power Inverters

  • Schroder D.;Kuhn H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.713-717
    • /
    • 2001
  • This paper focuses on a network model for GCTs which can be used to investigate high power circuits with or without using RC-snubbers. The series connection of GCTs is commonly applied in the high power inverter field. Here expensive and space-consuming snubbers are applied, to overcome the problem of an asymmetric distribution of the blocking voltage among the single GCTs. As an alternative to large snubbers, a new active gate drive concept is proposed and investigated by simulation.

  • PDF

Status of Inspection and Management for Nuclear Power Plants Snubbers (원전 방진기 검사 및 관리 현황)

  • Cho, Yong-Bae;Moon, Gyoon-young;Yoo, Hyun-Joo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.20-24
    • /
    • 2014
  • Recently, it is getting more and more important ensuring the integrity for the equipment degradation according to the increase of nuclear power plant operating period. In many equipment of the nuclear power plant, snubbers mainly installed in reactor coolant pumps, steam generators and piping protected the equipment and piping from the occurrence of transient dynamic loads such as the earthquake, thermal load during the plant operation. This report describes the function, regulation, inspection requirements and management status of the snubbers installed in domestic nuclear power plants.

Friction Snubber Development Using Sponge Iron (환원분철을 이용한 마찰식 완충기 개발)

  • 김병삼
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.10
    • /
    • pp.1021-1028
    • /
    • 2004
  • Developed friction snubbers changes the shock or vibration into a heat energy by mechanical friction. Snubber is divided into friction snubbers and hydraulic snubbers according to the operation types. However, hydraulic snubber has a lot of problems caused by temperature, humidity, radioactivity, and viscosity of hydraulic fluid. In these respects, to solve these problems, not only do friction snubber supplement lacks of hydraulic snubber but has also simpler structure than hydraulic snubber. In this paper, friction snubber used sponge iron by friction material is experimentally compared with general friction snubber In this results, the experiment verifies friction function and produce the manufacture condition for the effective friction snubber development.

Design of the Wire Rope Type Snubber for Earthquake and Vibration of Piping System (Wire Rope형 배관 지진$\cdot$진동완충기의 설계)

  • 김영중
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.173-179
    • /
    • 1998
  • The piping system of a power plant suffers not only thermal expansion according to the temperature variation, but also many kinds of load: steady state vibrations due to the equipment operation or fluid flow, and transient vibrations due to the earthquake or explosion, etc. The snubbers are usually installed on the piping system to allow thermal expansion, and to reduce dynamic responses. Most snubbers are kinds of hydraulic and mechanical type, which can be degraded by leakage and abrasion, and required much cost for maintenance and replacement. Recently the wire rope type snubbers are developed and applied to the power plant, and proved as effective to reduce piping system vibration. Wire rope type snubber uses the bending rigidity and energy dissipation properties of ropes. This paper presents the procedure of design, and the method to apply hysteresis curve to the dynamic response analysis. Experiments were also conducted to confirm design results.

  • PDF

Soft Switching Forward Converter Using Non-Dissipative Snubber (무손실 스너버 적용 소프트 스위칭 Forward 컨버터)

  • 김은수;김태진;최해영;조기연;김윤호
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.256-260
    • /
    • 1997
  • To achieve high efficiency in high power and high frequency applications, reduction of switching losses and noise is very important. In this paper, an improved soft switching forward converter is proposed. The proposed converter is constructed by using non-dissipative snubbers in parallel with the main switch and output diode of the conventional forward converter. Due to the use of the non-dissipative snubbers in the primary and secondary, the proposed converter achieves zero-voltage and zero-current switching for all switching devices without switching losses and output diode recovery losses. The complete operating principles, theoritical analysis, experimental results will be presented.

  • PDF

High Frequency Soft Switching Forward DC/DC Converter (고주파 소프트 스위칭 Forward DC/DC 컨버터)

  • 김은수;최해영;조기연;김윤호
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.409-412
    • /
    • 1998
  • In this paper, an improved soft switching forward dc/dc converter is proposed. The proposed converter is constructed by using non-dissipate snubbers in parallel with the main switch and output diode of the conventional forward converter. Due to use of the non-dissipative snubbers, the proposed converter achieves zero-voltage switching for all switching devices and output diodes without switching losses. The complete operating principles and experimental results will be presented.

  • PDF

A Novel Prototype of Duty Cycle Controlled Soft-Switching Half-Bridge DC-DC Converter with Input DC Rail Active Quasi Resonant Snubbers Assisted by High Frequency Planar Transformer

  • Fathy, Khairy;Morimoto, Keiki;Suh, Ki-Young;Kwon, Soon-Kurl;Nakaoka, Mutsuo
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.89-97
    • /
    • 2007
  • This paper presents a new circuit topology of active edge resonant snubbers assisted half-bridge soft switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed half-bridge high frequency PWM inverter with a high frequency planar transformer link in addition to input DC busline side power semiconductor switching devices for PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC buslines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, a high switching frequency IGBTs can be actually selected in the frequency range of 60 kHz under the principle of soft switching. The performance evaluations of the experimental setup are illustrated practically. The effectiveness of this new converter topology is proved for such low voltage and large current DC-DC power supplies as DC bus feeding from a practical point of view.

Design of A 2KW Soft-Switching ZVT Power Factor Correction Converter With Active Snubbers

  • Park, Kyoung-Soo;Kim, Yoon-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.790-794
    • /
    • 2001
  • In this paper a soft switching ZVT power factor converter using active snubbers is designed to improve efficiency and reduce voltage spike and parasitic ringing. The main switch achieves ZVT and the auxiliary switch performs with ZCS. A 2KW soft switching ZVT converter is designed with switching frequency 100kHz, output voltage 400VDC. Then the designed system is realized and experimental results show that the measured efficiency and power factor are over $97.45\%$ and 0.997 respectively with an input current THD less than $3\%$.

  • PDF