• Title/Summary/Keyword: Smooth reconstruction

Search Result 81, Processing Time 0.02 seconds

Primary Sternal Tuberculosis with Spontaneous Fracture Treated by Resection and Reconstruction -A Case Report- (원발성 흉골결핵의 외과적 치험 -1례 보고-)

  • 배상일;김미혜;오태윤;장운하
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.190-193
    • /
    • 1998
  • We experienced a case of primary sternal tuberculosis with destroyed midsternum and bony defect. An 22-year-old female was admitted to our hospital two times for severe sternal pain and spontaneous fracture without history of trauma. On hospital admission, chest X-ray and chest CT showed destruction of midsternum and soft tissue swelling. Fine needle aspiration cytology revealed tuberculous osteomyelitis with cold abscess. And the patient was treated with usual anti-tubeculosis medication for preoperative preparation. At operation, we confirmed midsternal destruction with cold abscess and multiple sinus tracts. After removal of diseased sternal segment and cold abscess, we performed sternal reconstruction with autologus iliac bone graft. The pathologic report was compatible with tuberculous osteomyelitis and caseous necrosis The postoperative course was smooth and uneventful, and she remains well without sternal instability two months later.

  • PDF

Evaluation to Obtain the Image According to the Spatial Domain Filtering of Various Convolution Kernels in the Multi-Detector Row Computed Tomography (MDCT에서의 Convolution Kernel 종류에 따른 공간 영역 필터링의 영상 평가)

  • Lee, Hoo-Min;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.71-81
    • /
    • 2008
  • Our objective was to evaluate the image of spatial domain filtering as an alternative to additional image reconstruction using different kernels in MDCT. Derived from thin collimated source images were generated using water phantom and abdomen B10(very smooth), B20(smooth), B30(medium smooth), B40 (medium), B50(medium sharp), B60(sharp), B70(very sharp) and B80(ultra sharp) kernels. MTF and spatial resolution measured with various convolution kernels. Quantitative CT attenuation coefficient and noise measurements provided comparable HU(Hounsfield) units in this respect. CT attenuation coefficient(mean HU) values in the water were values in the water were $1.1{\sim}1.8\;HU$, air($-998{\sim}-1000\;HU$) and noise in the water($5.4{\sim}44.8\;HU$), air($3.6{\sim}31.4\;HU$). In the abdominal fat a CT attenuation coefficient($-2.2{\sim}0.8\;HU$) and noise($10.1{\sim}82.4\;HU$) was measured. In the abdominal was CT attenuation coefficient($53.3{\sim}54.3\;HU$) and noise($10.4{\sim}70.7\;HU$) in the muscle and in the liver parenchyma of CT attenuation coefficient($60.4{\sim}62.2\;HU$) and noise ($7.6{\sim}63.8\;HU$) in the liver parenchyma. Image reconstructed with a convolution kernel led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image scanned with a high convolution kernel(B80) led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image medications of image sharpness and noise eliminate the need for reconstruction using different kernels in the future. Adjusting CT various kernels, which should be adjusted to take into account the kernels of the CT undergoing the examination, may control CT images increase the diagnostic accuracy.

  • PDF

Curve Reconstruction from Oriented Points Using Hierarchical ZP-Splines (계층적 ZP-스플라인을 이용한 곡선 복구 기법)

  • Kim, Hyunjun;Kim, Minho
    • Journal of the Korea Computer Graphics Society
    • /
    • v.22 no.5
    • /
    • pp.1-16
    • /
    • 2016
  • In this paper, we propose and efficient curve reconstruction method based on the classical least-square fitting scheme. Specifically, given planar sample points equipped with normals, we reconstruct the objective curve as the zero set of a hierarchical implicit ZP(Zwart-Powell)-spline that can recover large holes of dataset without loosing the fine details. As regularizers, we adopted two: a Tikhonov regularizer to reduce the singularity of the linear system and a discrete Laplacian operator to smooth out the isocurves. Benchmark tests with quantitative measurements are done and our method shows much better quality than polynomial methods. Compared with the hierarchical bi-quadratic spline for datasets with holes, our method results in compatible quality but with less than 90% computational overhead.

Comparison of irradiated and non-irradiated acellular dermal matrices in breast reconstruction under radiotherapy

  • Woo, Soo Jin;Ha, Jeong Hyun;Jin, Ung Sik
    • Archives of Plastic Surgery
    • /
    • v.48 no.1
    • /
    • pp.33-43
    • /
    • 2021
  • Background Acellular dermal matrices (ADMs) have become an essential material for implant-based breast reconstruction. No previous studies have evaluated the effects of sterility of ADM under conditions of radiation. This study compared sterile (irradiated) and aseptic (non-irradiated) ADMs to determine which would better endure radiotherapy. Methods Eighteen male Balb/C mice were assigned to the control group with no irradiation (group 1) or one of two other groups with a radiation intensity of 10 Gy (group 2) or 20 Gy (group 3). Both sterile and aseptic ADMs were inserted into the back of each mouse. The residual volume of the ADM (measured using three-dimensional photography), cell incorporation, α-smooth muscle actin expression, and connective tissue growth factor expression were evaluated. The thickness and CD3 expression of the skin were measured 4 and 8 weeks after radiation. Results In groups 2 and 3, irradiated ADMs had a significantly larger residual volume than the non-irradiated ADMs after 8 weeks (P<0.05). No significant differences were found in cell incorporation and the amount of fibrosis between irradiated and non-irradiated ADMs. The skin was significantly thicker in the non-irradiated ADMs than in the irradiated ADMs in group 3 (P<0.05). CD3 staining showed significantly fewer inflammatory cells in the skin of irradiated ADMs than in non-irradiated ADMs in all three groups after 4 and 8 weeks (P<0.05). Conclusions Under radiation exposure, irradiated ADMs were more durable, with less volume decrease and less deposition of collagen fibers and inflammatory reactions in the skin than in non-irradiated ADMs.

Characterization and Genetic Profiling of the Primary Cells and Tissues from Mandible of Mouse Fetus and Neonate

  • Kang, Jung-Han;Nam, Hyun;Park, Soon-Jung;Oh, Keun-Hee;Lee, Dong-Seup;Cho, Jae-Jin;Lee, Gene
    • International Journal of Oral Biology
    • /
    • v.32 no.1
    • /
    • pp.13-22
    • /
    • 2007
  • The stem cell research is emerging as a cutting edge topic for a new treatment for many chronic diseases. Recently, dental stem cell would be possible for regeneration of tooth itself as well as periodontal tissue. However, the study of the cell characterization is scarce. Therefore, we performed the genetic profiling and the characterization of mouse fetus/neonate derived dental tissue and cell to find the identification during dental development. We separated dental arch from mandibles of 14.5 d fetal mice and neonate 0 d under the stereoscope, and isolated dental cells primarily from the tissues. Then, we examined morphology and the gene expression profiles of the primary cells and dental tissues from fetus/neonate and adult with RT-PCR. Primary dental cells showed heterogeneous but the majority was shown as fibroblast-like morphology. The change of population doubling time levels (PDLs) showed that the primary dental cells have growth potential and could be expanded under our culture conditions without reduction of growth rate. Immunocytochemical and flow cytometric analyses were performed to characterize the primary dental cell populations from both of fetus (E14.5) and neonate. Alpha smooth muscle actin (${\alpha}-SMA$), vimentin, and von Willebrand factor showed strong expression, but desmin positive cells were not detected in the primary dental cells. Most of the markers were not uniformly expressed, but found in subsets of cells, indicating that the primary dental cell population is heterogeneous, and characteristics of the populations were changed during culture period. And mesenchymal stem cell markers were highly expressed. Gene expression profile showed Wnt family and its related signaling molecules, growth factors, transcription factors and tooth specific molecules were expressed both fetal and neonatal tissue. The tooth specific genes (enamelin, amelogenin, and DSPP) only expressed in neonate and adult stage. These expression patterns appeared same as primary fetal and neonatal cells. In this study we isolated primary cells from whole mandible of fetal and neonatal mice. And we investigated the characteristics of the primary cells and the profile of gene expressions, which are involved in epithelial-mesenchymal interactions during tooth development. Taken together, the primary dental cells in early passages or fetal and neonatal mandibles could be useful stem cell resources.

Safety Accident Prevention Activities & Actual Conditions According to Physical Education Teacher's Value Orientation (체육교사의 가치정향에 따른 안전사고 예방활동 및 실태)

  • Jeong, Suk-Bum;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.4
    • /
    • pp.79-95
    • /
    • 2003
  • This dissertation aims to analyze various safety accidents taking place during physical education class according to physical education teacher's value orientation, to identify teacher's value orientation that can minimize safety accidents, and to provide basic materials for safe and smooth class management. For this purpose, data have been collected from 261 physical education teachers at some middle and high schools in G City in Kyung-Ki Province and Busan Metropolitan City. The materials were treated as follows: The variables on demographic characteristics of physical education teachers are determined by t-test ; The analysis of one-way ANOVA and relationship between value orientation and safety accident prevention activities was conducted through Pearson's linear correlation analysis and multiple regression; The analysis of the relationship between value orientation and actual conditions of safety accidents was conducted through logistic regression. First, there is almost no awareness difference of physical education teachers' value orientation according to demographical variables. The value orientation physical education teachers consider to be the most important is, however, mainly 'mastery of disciplinary lesson.' There is a statistically significant difference in safety accident prevention activities according to demographical variables. Teachers' focuses in class contents showed a significant difference according to teaching experience and working area, while the dependency on facility has a significant difference according to teaching experience and school type. Second, there is no correlation between physical education teacher's value orientation and safety accident prevention activities because there is virtually no statistically significant difference between them. It means that safety accident prevention activities are not related with on which teachers place emphasis among mastery of disciplinary lesson, social reconstruction, self-realization, ecological integration and value orientation on learning process. Third, the analysis of safety accident prevention activities according to physical education teachers' value orientation revealed that the lower value orientation in social reconstruction is, the more safety accidents teachers experience. It is also found that crashes among students, ball games and leg injuries are inter-related with social reconstruction in value orientation, over-motivation and unskilled motor function ; athletic sports with value orientation on learning process and safety prevention training ; unskilled motor functions with value orientation in ecological integration and disobedience to teacher's directions ; winter accidents with mastery of disciplinary lesson in value orientation. In conclusion, the research indicates that physical education teacher's value orientation according to demographical variables didn't show any significant difference, while one according to safety accident prevention activities showed significant difference. Besides, physical education teachers' value orientation is not related to safety accident prevention activities, but the relationship between value orientation and actual conditions of safety accidents showed correlations according to each variable. Especially, teachers with lower value orientation in social reconstruction experienced more safety accidents. Therefore, physical education teachers can manage physical education class more safely with more emphasis on value orientation in social reconstruction.

  • PDF

CORRECTION OF POSTTRAUMATIC DIPLOPIA AND ENOPHTHALMOS USING AUTOGENOUS COMPOSITE CONCHAL CARTILAGE AND TEMPORAL FASCIAL;A CASE REPORT (이개연골과 측두근막의 자가복합이식술에 의한 외상성 복시현상과 안구함몰의 치험례)

  • Kim, Il-Kyu;Lee, Seong-Jun;Ha, Soo-Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.12 no.1
    • /
    • pp.114-120
    • /
    • 1990
  • This is a case report of correction of posttraumatic diplopia and enophthalmos using autogenous composite conchal cartilage and temporal fascia. The results are as follows. 1. Diplopia and enophthalmos may be persistent complications in zygomatic complex fracture. 2. The concha is a reservior of autogenous cartilage which leaves no cosmetic and functional deformity in reconstruction of orbital floor. 3. Warpping the cartilage in temporal fascia may serve to increase implant stability and get graft with smooth edge. 4. Donor incision lines are well hidden within the scalp and in auriculocephalic fold.

  • PDF

High-Performance Spatial and Temporal Error-Concealment Algorithms for Block-Based Video Coding Techniques

  • Hsu, Ching-Ting;Chen, Mei-Juan;Liao, Wen-Wei;Lo, Shen-Yi
    • ETRI Journal
    • /
    • v.27 no.1
    • /
    • pp.53-63
    • /
    • 2005
  • A compressed video bitstream is sensitive to errors that may severely degrade the reconstructed images even when the bit error rate is small. One approach to combat the impact of such errors is the use of error concealment at the decoder without increasing the bit rate or changing the encoder. For spatial-error concealment, we propose a method featuring edge continuity and texture preservation as well as low computation to reconstruct more visually acceptable images. Aiming at temporal error concealment, we propose a two-step algorithm based on block matching principles in which the assumption of smooth and uniform motion for some adjacent blocks is adopted. As simulation results show, the proposed spatial and temporal methods provide better reconstruction quality for damaged images than other methods.

  • PDF

Shape Recognition of 3-D Object Using Texels (텍셀을 이용한 3차원 물체의 형상 인식)

  • Kim, Do-Nyun;Cho, Dong-Sub
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.460-464
    • /
    • 1990
  • Texture provides an important source of information about the local orientation of visible surfaces. An important task that arises in many computer vision systems is the reconstruction of three-dimensional depth information from two-dimensional images. The surface orientation of texel is classified by the Artificial Neural Network. The classification method to recognize the shape of 3D object with artificial neural network requires less developing time comparing to conventional method. The segmentation problem is assumed to be solved. The surface in view is smooth and is covered with repeated texture elements. In this study, 3D shape reconstruct using interpolation method.

  • PDF

Automatic Generation of the Input Data for Rapid Prototyping from Unorganized Point Cloud Data (임의의 점 군 데이터로부터 쾌속조형을 위한 입력데이터의 자동생성)

  • Yoo, Dong-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.11
    • /
    • pp.144-153
    • /
    • 2007
  • In order to generate the input data for rapid prototyping, a new approach which is based on the implicit surface interpolation method is presented. In the method a surface is reconstructed by creating smooth implicit surface from unorganized cloud of points through which the surface should pass. In the method an implicit surface is defined by the adaptive local shape functions including quadratic polynomial function, cubic polynomial function and RBF(Radial Basis Function). By the reconstruction of a surface, various types of error in raw STL file including degenerated triangles, undesirable holes with complex shapes and overlaps between triangles can be eliminated automatically. In order to get the slicing data for rapid prototyping an efficient intersection algorithm between implicit surface and plane is developed. For the direct usage for rapid prototyping, a robust transformation algorithm for the generation of complete STL data of solid type is also suggested.