• Title/Summary/Keyword: Smoke source

Search Result 123, Processing Time 0.036 seconds

Smoke Detection Based on RGB-Depth Camera in Interior (RGB-Depth 카메라 기반의 실내 연기검출)

  • Park, Jang-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.2
    • /
    • pp.155-160
    • /
    • 2014
  • In this paper, an algorithm using RGB-depth camera is proposed to detect smoke in interrior. RGB-depth camera, the Kinect provides RGB color image and depth information. The Kinect sensor consists of an infra-red laser emitter, infra-red camera and an RGB camera. A specific pattern of speckles radiated from the laser source is projected onto the scene. This pattern is captured by the infra-red camera and is analyzed to get depth information. The distance of each speckle of the specific pattern is measured and the depth of object is estimated. As the depth of object is highly changed, the depth of object plain can not be determined by the Kinect. The depth of smoke can not be determined too because the density of smoke is changed with constant frequency and intensity of infra-red image is varied between each pixels. In this paper, a smoke detection algorithm using characteristics of the Kinect is proposed. The region that the depth information is not determined sets the candidate region of smoke. If the intensity of the candidate region of color image is larger than a threshold, the region is confirmed as smoke region. As results of simulations, it is shown that the proposed method is effective to detect smoke in interior.

Characterization of Volatile Organic Compounds associated with Environmental Tobacco Smoke

  • Baek, Sung-Ok;Roger A. Jenkins
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.E
    • /
    • pp.41-58
    • /
    • 1998
  • In this study, a wide range of volatile organic constituents of environmental tobacco smoke (ETS) were determined using an environmental chamber, where ETS is the sole source of target compounds. ETS was generated in an environmental chamber by a number of different cigarettes, including the Kentucky reference cigarette and eight different commercial brands. More than 30 compounds were measured simultaneously for a total of twelve experimental runs. The target compounds are classified into three major classes, i.e. vapor phase ETS markers including 3-ethnylpyridine (3-EP) and nicotine, carbonyl compounds including formaldehyde, and volatile organic compounds (VOCs). The results from the chamber study were used to generate characterized ratios of selected VOCs to 3-EP, a vapor phase ETS marker. Emission factors for VOCs associated with ETS were also estimated. The characteristic ratios appeared to be generally in good agreement with published data obtained by environmental chamber studies similar to this study. This implies that the ratios may be useful for identifying and quantifying the impact of ETS as a source of target compounds in 'real world' indoor environments, which is affected by a complex mixture of multi-sources. The environmental chamber method described here provides a direct and reliable method to compare the ETS generated by different cigarettes. The method can also be applied to the simultaneous determination of many different ETS components.

  • PDF

A Study on Fire Characteristics in a Tall and Narrow Atrium

  • Sugawa, Osami;Takahashi, Wataru;Ohtake, Masanori;Satoh, Hiroomi
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.353-360
    • /
    • 1997
  • The modeling on fire safety assessment for a tall and narrow atrium is carried out using a reduced and full scale atrium models based on the performances of flow behavior in and near comer fire and smoke ventilation system. The comer (or wall) effects on the flame behavior considering air entrainment into a flame was evaluated theoretically and experimentally. Temperature, upward velocity, inlet air velocity, and pressure difference between the atrium space and atmosphere were measured systematically in a reduced scale model. The performance of the modeling to estimate temperature rise and natural air ventilation volume was verified based on the experimental results. Smoke filling rate from a model fire source set at the center of a tall and narrow atrium is fastest in the other cases in which fire source set in or near a corner. This suggested that the centering of the fire source is acceptable as the fire source position to assess the fire safety design for a tall and narrow atrium.

  • PDF

A Study of Smoke Movement in an Enclosed Corridor. (밀폐된 복도 공간내의 연기 거동에 관한 연구)

  • 김성찬;유홍선;정진용;김충익
    • Fire Science and Engineering
    • /
    • v.13 no.2
    • /
    • pp.18-25
    • /
    • 1999
  • There are a lot of works for predicting smoke movement in a building experimentally and m numerically. It is Vel${\gamma}$ important to predict a smoke movement in a corridor which is c connected to adjacent spaces. A numerical analysis of smoke movement in an enclosed c corridor is perlormed by a field model. The used field model is develo야d with 3-D u unstructured meshes, PISO Algorithm and buoyant plume model. In this study, tern야~ature a and flow field, some important p하ameters such as smoke spread time, hot layer temperature, c ceiling jet velocity were compared with experimental data which were perlormed in Korea I Ins디tute of Machinery and Materials. And average velocity of ceiling jet by this study is c compared with Hinkley's formula. This paper shows a flow characteristic around the soffit a and average velocity of ceiling jet is i따luenced by geometry of corridor, heat output, and d distance from the fire source.

  • PDF

A Study on the Auto Closing Systems Motion Analysis of Door in Smoke Control Zone (제연구역 출입문의 자동폐쇄장치 운동해석에 관한 연구)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.106-112
    • /
    • 2010
  • This study carried out the motion analysis of auto closing systems as basis study for development of auto closing systems for door in smoke control zone. This study established process of auto closing systems and analysis theory based on kinematics mechanism thesis and mechanism modelling of auto closing control units. And this study established engineering data construction and a source technology that can design each element of auto closing control units that choose closing force units through motion analysis simulation based on analysis theory. Therefore, it can give flexibility and elasticity of auto closing units development from this study. Also, it sees that can ready control means and technological countermeasure of smoke by development of auto closing units and secure high reliancity and stability of smoke control systems.

Evaluation of Smoke Control Performance of Ventilation System Using by Hot Smoke Test (Hot Smoke Test를 이용한 주차장 환기설비의 제연 성능평가)

  • Joung, Suckhwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.2
    • /
    • pp.47-56
    • /
    • 2019
  • Recently, in order to overcome the difficulty of entering a fire source due to the occurrence of a large amount of smoke in the event of a fire in a parking lot, it has used that a method of discharge smoke using air supply, exhaust fans and jet fans installed for ventilation of parking lots. In this study, the variation of flow in the smoke layer was observed using CCTV under two conditions, in which only the air supply fan operates and the manned fan operates together, and the temperature around the plume was compared to Albert eq. to assess its suitability as a parking lot ventilation performance evaluation method. As a result, it was found that the smoke layer could be disturbed if the Jet Fan was operated at the same time, which could lead to the possibility of an initial evacuation disturbance. However, the additional operation of the Jet Fan has been confirmed by the observation CCTV that the emission performance is improved, which is believed to help conduct the suppression operation. The temperature around the plume was measured and compared to Alpert eq, and was analyzed to be about $2^{\circ}C$ lower at the center axis of the plume and $9.0^{\circ}C$ higher at 8 m in the direction of the discharge of smoke. The results of temperature measurements around the plume were lower than the maximum temperature expected in AS 4391 and did not exceed the expected temperature risk caused by the experiment. As with these results, the temperature risk from the progression of hot smoke tests is foreseeable, so it will be available as one of the general evaluation methods for assessing smoke control performance in a parking lot without relevant criteria.

A Numerical Study of Smoke Movement In Atrium Space (아트리움 공간에 있어서 연기 유동에 관한 수치해석적 연구)

  • 노재성;유홍선;정연태;김충익;윤명오
    • Fire Science and Engineering
    • /
    • v.11 no.4
    • /
    • pp.3-14
    • /
    • 1997
  • The smoke filling process for the atrium space containing a fire source is simulated using two types of deterministic fire model : Zone model and Field model. The zone model used is the CFAST(version 1.6) model developed at the Building and Fire Research Laboratories, NIST in the USA. The field model is a self-developed frie field model based on Computational Fluid Dynamic (CFD) theories. This article is focused on finding out the smoke movement and temperature distribution in atrium space which is cubic in shape. For solving the liked set of velocity and pressure equation, the PISO algorithm, which strengthened the velocity-pressure coupling, was used. Since PISO algorithm is a time-marching procedure, computing time si very fast. A computational procedure for predicting velocity and temperature distribution in fire-induced flow is based on the solution, in finite volume method and non-staggered grid system, of 3-dimensional equations for the conservation of mass, momentum, energy, species and so forth. The fire model i.e Zone model and Field model predicted similar results for clear heights and the smoke layer temperature.

  • PDF

A Numerical Study of an Effect of the Aspect Ratio on Smoke Movement in funnel Fires (터널 화재시 종횡비에 따른 연기 거동에 관한 수치해석적 연구)

  • 이성룡;김충익;유홍선
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.1-6
    • /
    • 2004
  • In this study, numerical simulations were conducted to analyze an effect of the aspect ratio on smoke movement in tunnel fires using FDS 3.0. It was confirmed an application for tunnel fires in comparison with experimental results. The results showed relatively good agreement with experimental data within 1$0^{\circ}C$. Clear height of CFD by velocity distribution was about 3% higher than that of experiment. Smoke movement was confirmed by the analysis of temperature and velocity field. Results from variation of the aspect ratio showed good agreement with experimental data. The temperature at the vicinity of the fire source became lowly with the increase of the aspect ratio. But, decrease rate of the temperature was reduced by the decrease of the heat loss to the width direction.

A Study of Smoke Movement in a Short Tunnel (짧은 터널 내의 연기거동에 관한 연구)

  • Kim, Sung-Chan;Ryou, Hong-Sun;Kim, Chung-Ik;Hong, Ki-Bae
    • Tunnel and Underground Space
    • /
    • v.12 no.1
    • /
    • pp.31-36
    • /
    • 2002
  • This paper concerns smoke propagation in tunnel fires with various size of fire source. Experiments carried out in model tunnel and those results were compared with numerical results. The Froude scaling law was used to scale model tests for comparison with larger scale tests. In order to validate for numerical analysis, temperature distribution of predicted data was compared with measured data. Examining the temperature distribution, we found that smoke layer does not come down under 50% of tunnel heights for a short tunnel heights for a short tunnel firs without ventilation. Front velocity of smoke layer is proportional to the cube root of heat release rate. And it is in good agreement with existing empirical expression and numerical prediction. In a short tunnel fire, horizontal propagation of smoke layer is more important than vertical smoke movement for evacuation plan.

The Characteristics of Exhaust Gas in Diesel Engine by Corana Discharge-EGR System (코로나 방전-EGR 조합시스템에 의한 디젤기관의 배기 가스 특성)

  • Park, Jae-Yoon;Jung, Jang-Gun;Kim, Jong-Suk;Ha, Hyun-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.39-44
    • /
    • 2005
  • A great part of flint fuel is Hydrogen and carbon's combination, they should be generated steam and carbon gas when combine with oxygen for perfect combustion in the inside of engine but, the pollutive material are discharged, even though perfect combustion condition especially $NO_x$ and Smoke. they are really harmful for health. In this paper was shown the result of discharging gas' reduction quality. which used combination of corona discharge using the high voltage source of common frequency with EGR. $NO_x$ is increased in entire load erea in proportion to increasing of EGR rate and impression voltage. Smoke is increased slowly under 75[%] in load rate but it is increased rapidly in entire load erea and the reduction rate of Smoke is increased in proportion to increasing of impression voltage.