• Title/Summary/Keyword: Smoke material

Search Result 112, Processing Time 0.024 seconds

Smoke Density Values to the variance of test conditions (시험조건 변화에 따른 연기밀도 특성 조사)

  • Lee Duck-Hee;Lee Cheul Kyu;Jung Woo-Sung;Kim Sun-ok
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.339-345
    • /
    • 2004
  • In this study we reported the Smoke Density values of interior materials of railroad passenger car and investigated the specific smoke density(Ds) by NBS smoke chamber to the variance of some test conditions. First we compared the result of Ds from ISO 5659-2 with that from ASTM E 662 for same material. Secondary studied the Ds value to the variance of specimen shape and thickness and to the variance of other conditions.

  • PDF

Comparison of GC-Profile on Tobacco Smoke Components (담배 연기성분의 GC-Profile 특성비교)

  • 나효환;한상빈;복진영;이운철;백순옥;장기철;양광규
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.16 no.2
    • /
    • pp.152-162
    • /
    • 1994
  • This study was designed to establish an analytical method for the properties of leaf tobacco smoke. Lyophilized TPM from leaf tobacco smoke was extracted with MeOH, dried under reduced pressure, and trimethyl-silylated(TMS). Gas chromatography of the material using SPB-5 column showed 120 quantifiable peaks. Among those, 26 compounds including a hydrocarbons, Neophytadiene. and Levulinic acid could be identified through GC-MS. Smoke properties of 5 manufacturing grades and 2 oriental cultivars of domestic and imported leaf tobacco including AB3O-1 were analyzed. For flue-cured tobacco, content of the compounds in the smoke was generally higher in American leaf tobacco except for glycerol compounds. For burley tobacco, domestic leaves were found to have much higher amount of smoke compound than imported leaves. Among oriental tobacco, Izmir contained slightly higher amount of smoke compounds than Basma. Key words : GC - profile. TPM. TMS. Leaf tobacco.

  • PDF

Smoke density comparison for composite and single materials of train seat (철도차량 시트재료의 개별 및 조립체 시험에 대한 연기특성 비교)

  • Lee, Eun-Kyoung;Lee, Duck-Hee;Cho, Hee-Ki;Lee, Cheul-Kyu;Jung, Woo-Sungg
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.196-201
    • /
    • 2006
  • Due to the damage which is caused by with the smoke, in the analysis statistics of a fire accident smoke is becoming the important evaluation index of fire quality. We must follow the procedures to use interior material for railway car as stated the Safety regulation for the urban railway car. In this study, we compared the Smoke Density of the train seat by test between Cone-Calorimeter and Smoke Density-Chamber. The results showed that the smoke density by test between Cone-Calorimeter and Smoke Density-Chamber is visible a similar tendency.

  • PDF

A Study on the Analysis of Smoke Density Characteristics for Wood-Plastic Composites (합성목재의 연기밀도특성 분석에 관한 연구)

  • Shin, Baeg-Woo;Song, Young-Ho;Rie, Dong-Ho;Chung, Kook-Sam
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.119-124
    • /
    • 2011
  • In this study, we measured the smoke density characteristics to find the fire risk of Wood-Plastic composites (WPCs) which are one of spotlighting materials for landscape architecture and residential construction material with the cone calorimeter tester (by ISO 5660-2) and the smoke density tester (by ASTM E 662). In addition, the identical test was implemented to compare the smoke density characteristics between the red pine and the antiseptic wood. The result of cone calorimeter test showed that emissions of carbon monoxide, carbon dioxide and total smoke production rate of WPCs were higher than those of red pine and antiseptic wood. And the result of smoke density test showed that maximum specific optical smoke density(Dm) of WPCs was higher than that of red pine and antiseptic wood as well.

Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant (난연성 폴리 올레핀 케이블 절연재료의 내화특성)

  • Yoon, Hun-Ju;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analyzed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC 600[V] wire. Messurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflaming pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of $2.5{\pm}0.04[w/cm^{2}]$ for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomplete combustion of FR-PVC which has high content of carbon in compound.

  • PDF

Fire Resistance Characteristics of Polyolefin cable Insulating Materials for Flame Retardant (난연성 폴리 올레핀 케이블 절연재료의 내화특성)

  • 윤헌주;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.251-254
    • /
    • 2001
  • In this paper, we analysed the properties change of electric wire when the thermal stress was applied to NFR-8 and FR-PVC [600] wire. Measurement is made of the attenuation of a light beam by smoke accumulating with in a closed chamber due to nonflamining pyrolytic decomposition and flaming combustion. Results are expressed in terms of specific optical density which is derived from a geometrical factor and the measured optical density a measurement characteristic of the concentration of smoke. Referenced documents were ASTM E662 standard test method for specific Ds generated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of 2.5${\pm}$0.04[w/$\textrm{cm}^2$] for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 7.2 to 77.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. The amount of carbon monoxide generated was found to be much higher in FR-PVC decomposition than in NFR-8 due to incomp1ete combustion of FR-PVC which has high content of carbon in compound.

  • PDF

Experimental Study on Smoke Production and Smoke Generation in Thermoplastic Resins Based on PP, PMMA, and PVC (열가소성 수지(PP, PMMA, PVC)의 연기생성 및 발생에 관한 실험적 연구)

  • Hwang, Euy-Hong;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.1-7
    • /
    • 2020
  • Due to the complexity and large size of buildings, plastic resin is widely used as a building material. Accordingly, the occurrence of fires caused by plastics is increasing. Due to the nature of plastic resin fires, the amount of damage to properties and human life caused by combustion products such as smoke are large, and these damages are related to smoke production and smoke generation. Therefore, this study reviews smoke measurement methods and laws on domestic buildings and fire services. Experiments were conducted based on three smoke-related test standards (ISO 5660-1, ISO 12136, ASTM E 662). The experiment results indicate a total smoke production and generation by PP, PVC, and PMMA of 43.27, 32.83, and 12.33 ㎡, and 27.855, 9.599, and 6.975 g, respectively.

Study on the Smoke Density Characteristics of Flame Retardant Sol Manufactured by a Sol-gel Method (졸-겔법으로 제조된 방염제졸의 연기밀도 특성에 관한 연구)

  • Cho, Kyeong-Rae;Lee, Chun-Ha;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.11-18
    • /
    • 2017
  • In this study, a non-halogen type organic-inorganic hybrid flame retardant sol, which can impart flame resistance to synthesize silicate of inorganic material and silane coupling agent of organic material by a sol-gel method, were newly manufactured. The addition of flame retardant will prevent loss of life in a fire because smoke from the flammability of interior finishing materials used as the construction materials poses a major danger. The smoke density measurement standard based on flame retardant performance standards, experiments were conducted according to the test equipment and procedures of ASTM E 662. The non-flaming mode experiment and the flaming mode experiment were conducted to confirm the performance of the manufactured flame retardant sol. As a result, the manufactured flame retardant sol improved the physical properties and heat resistance of existing flame retardants, and decreased the smoke production of the fire. Therefore, it may be possible to reduce the damage caused by smoke and expand the applications to various interior finishing materials.

Smoke Detection Using the Ratio of Variation Rate of Subband Energy in Wavelet Transform Domain (웨이블릿 변환 영역에서 부대역 에너지 변화율의 비를 이용한 연기 감지)

  • Kim, JungHan;Bae, Sung-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.3
    • /
    • pp.287-293
    • /
    • 2014
  • Early fire detection is very important to avoid loss of lives and material damage. The conventional smoke detector sensors have difficulties in detecting smoke in large outdoor areas. The video-based smoke detection can overcome these drawbacks. This paper proposes a new smoke detection method in video sequences. It uses the ratio of variation rate of subband energy in the wavelet transform domain. In order to reduce the false alarm, candidate smoke blocks are detected by using motion, decrease of chromaticity and the average intensity of block in the YUV color space. Finally, it decides whether the candidate smoke blocks are smokes or not by using their temporal changes of subband energies in the wavelet transform domain. Experimental results show that the proposed method noticeably increases the accuracy of smoke detection and reduces false alarm compared with the conventional smoke detection methods using wavelets.

A Study on the Toxic Gases and Smoke Hazard of PASCON Trough (파스콘 트로프의 연기유독성에 관한 연구)

  • Lee, Chang-Woo;Hyun, Seong-Ho;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.1-7
    • /
    • 2006
  • The aim of the research is to estimate the effect of smoke and combustion gases on humane body indirectly through measuring the toxicity of those. For this purpose, the toxic index of smoke and combustion gases was investigated by smoke hazard test and analysis of smoke which were conducted by KS F 2271 and NES 713 method respectively. It i s proved by KS F 2271 method that PASCON trough is suitable to the testing standard of interior material and construction of building. In addition, it is identified by NES 713 method that combustion gases occurring in PASCON product were only carbon dioxide and carbon monoxide, and the smoke index of those was 0.944. This value means that the hazard effect of smoke gases on humane ! body can possibly happens when exposed to the smoke gases for more than 30 min. In aspect of the domestic situation that have not regulated the hazard estimation and the emissions of smoke when the flame retarding ability of the products have been requested, the toxic indexes of PASCON products are comparatively low.