• Title/Summary/Keyword: Smoke layer

Search Result 119, Processing Time 0.02 seconds

The Flow Characteristics around Circular Cylinder of Pressure Interference with Slits (표면압력이 상호 간섭되는 슬릿을 가진 원주의 후류 유동 특성)

  • 부정숙;김진석;류병남
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.736-744
    • /
    • 2003
  • This study is conducted to investigate aerodynamic forces and wake structures about the pressure interference of a circular cylinder with slits. An experimental investigation of a circular cylinder with slits is carried out in uniform flow in the range of Reynolds number from 8,000 to 32,000 using X-type hot wire. Flow visualization is executed by smoke-wire method to understand the mechanism of these vortex formation process. Inspection in the wake at X/D=5.5 of the cylinder with the slits suggested that a strong vortex-shedding pattern for these cylinders is revealed compare with a circular cylinder without slits. It is found that the rolling up position of shear layer of the cylinder with slits is shorten compare with a circular cylinder without slits.

A Study on the Fire Suppression Characteristics Using a Water Mist (물분무에 의한 화재제어 특성에 관한 연구)

  • 김성찬;유홍선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.261-267
    • /
    • 2003
  • The present study investigates the fire suppression characteristics using a water mist fire suppression system. Numerical simulations of fire suppression with water mist are performed with considering the interaction of fire plume and water droplet, droplet evaporation, and combustion of pool fire. The predicted temperature fields of smoke layer are compared with that of measured data. Numerical results agree with the experimental results within 5$^{\circ}C$ in the case without water mist In the case of fire suppression with water mist, numerical results dose not predict well lot temperature field in the gradual cooling region after water mist injection. But the predicted results of initial fire suppression are in good agreement with that of measured data. The reason of the discrepancy between predicted and measured data is due to the variation of turning rate during the injection of water mist. The effect of burning rate on the fire suppression is left as future study.

An Experimental Study of Fire Suppression Using a Water Mist in a Compartment (물분무를 이용한 화재제어에 관한 실험적 연구)

  • Kim, Sung-Chan;Park, Hyun-Tae;Ryou, Hong-Sun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.367-373
    • /
    • 2003
  • The present study investigates the fire suppression characteristics using a water mist fire suppression system. The fire extinguishing times are measured for various fire sources, fuel types, and different total flooding rates of water mist. Pool fire with hydrocabon fuel is successfully extinguished within a minute under the operating conditions of the water mist system. Two different regimes of the smoke layer cooling are observed, such as rapid and slow cooling processes. The regimes are divided by threshold time which is calculated with auto-correlation function. The threshold time for the initial cooling decreases with increasing water flow-rates and fire sources. These initial cooling effects play an important role in preventing the occurance of flashover fire by the initial fire suppression.

The Effect on Wake Flow and Vortex Shedding Frequency by Vortex Stabilizer in Karman Vortex Type Air Flow Sensor (칼만와류식 공기유량센서의 와안정판이 후류유동장과 와유출주파수에 미치는 영향)

  • 임성원;류병남;이종춘;부정숙
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.846-856
    • /
    • 2001
  • An experimental study has been made to investigate the effect on wake flow and vortex shedding frequency by vortex stabilizer in Karman vortex type air flow sensor. The conditions investigated include 3 types of shapes and 3 types of separation distances of the vortex stabilizer. The phase averaged technique and smoke-wire flow visualization method are used to understand the detail information. The rolling up position of shear layer is fixed by the influence of the vortex stabilizer. Especially, the convex type vortex stabilizer has shown the more stable repeatability and linearity regarding the vortex shedding frequency compared to the other types.

  • PDF

A Numerical Study of Fire Development Characteristics on a Ro/Ro Ferry Vehicle Deck. (Ro/Ro 여객선 차량갑판의 화재 특성에 관한 수치 해석 연구)

  • Kim, Sung-Chan;Ryou, Hong-Sun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.41 no.5
    • /
    • pp.48-54
    • /
    • 2004
  • The present study investigates the fire development characteristics on a Ro-Ro ferry vehicle using the modified FDS code considering droplet break-up. Numerical simulations are compared with model-scale tests for validation of field model. The predicted results such as smoke layer temperature and oxygen concentration are in good agreement with model-scale tests. Also, it is shown that water spray systems are very effective to control the fire development on a vehicle deck. These numerical simulations using a field model may be helpful in accomplishing the fire safety for marine vehicle.

Growth Characteristics and Hydrocarbon Patterns of Flammable Liquid on a Vinyl Layer (비닐장판 위에서 연소된 인화성 액체의 성장 특성과 탄화 패턴)

  • Joe, Hi-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.15-21
    • /
    • 2018
  • This study examined the growth characteristics and carbonization pattern when a fire occurs due to a flammable liquid sprinkled on a vinyl floor. When acetone was sprinkled on a floor, the flame reached its peak in approximately 0.2 s after it was ignited. The lower part of the flame showed a laminar pattern while the upper part showed a turbulent pattern. The pattern showed a turbulent pattern and generated white smoke. The combustion completed floor surface showed carbonization of a dim pore pattern. In the case of benzene, an intense flame was formed in approximately 0.6 s after ignition. The flame length was measured to be approximately 50 mm. When the flame became weak, a significant amount of black smoke was generated due to incomplete combustion. The combustion completed floor surface showed carbonization of a pour pattern and splash pattern. In the case of alcohol, an intense flame was formed in approximately 1.1 s after ignition. In addition, the depth of carbonization was significant where the flammable liquid was collected and a trace of carbonization was observed at the boundary of the flow path of the flammable liquid.

Study on Flow Structure of Turbulent Boundary Layer Over Semi-Circular Riblets (반원형 리블렛 상부 난류경계층의 유동 구조 연구)

  • Lee, Sang Hyun;Lee, Sang Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.7
    • /
    • pp.937-944
    • /
    • 1999
  • The near-wall flow structures of turbulent boundary layer over riblets having semi-circular grooves were investigated experimentally for the drag decreasing ($s^+=25.2$) and drag increasing ($s^+=40.6$) cases. The field of view used for tho velocity field measurement was $6.75{\times}6.75mm^2$ in physical dimension, containing two grooves. One thousand instantaneous velocity fields over the riblets were extracted for each case of drag increase and decrease. For comparison, five hundreds instantaneous velocity fields over a smooth flat plate were also obtained under the same flow conditions. To see the global flow structure qualitatively, the flow visualization was also performed using the synchronized smoke-wire technique. For the drag decreasing case ($s^+=25.2$), most of the streamwise vortices stay above the riblets, interacting with the riblet tips. The high-speed in-rush flow toward the riblet surface rarely influences the flow inside tho riblet valleys submerged in the viscous sublayer. The riblet tips seem to impede the spanwise movement of the longitudinal vortices and induce secondary vortices. The turbulent kinetic energy in the riblet valley is sufficiently small to compensate the increased wetted area of the riblets. In addition, in the logarithmic region, the turbulent kinetic energy are small or almost equal to that of a smooth flat plato. For the drag increasing case ($s^+=40.6$), however, the streamwise vortices move into the riblet valley freely, interacting directly with the riblet inner surface. The penetration of the high-speed in-rush flow on the riblets increases tho skin-friction. The turbulent kinetic energy is increased in the riblet valleys and even in the outer region compared to that over a flat plate.

Fire Simulation for Vent Flow and Temperature in Engine Room of Small Ship: Effects of Ceiling Duct Location and Side Vent Size (소형선박 기관실의 개구부 유동 및 온도에 대한 화재시뮬레이션: 천장 통풍통 위치 및 측면 개구부 크기 영향)

  • Jeong, Lee-Gyu;Lee, Chi Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.454-465
    • /
    • 2020
  • Fire simulations were performed using the Fire Dynamics Simulator (FDS) software to examine the vent flow and temperature in the engine room of a small ship. A diesel fire with a heat release rate of 10 kW was targeted, and the effects of the ceiling duct location, side vent existence and nonexistence, and side vent size were investigated. The existence or nonexistence of the side vent and its size considerably affected the smoke behavior, mass flow rate through the vent, and temperature. When the side vent was not installed or was small, the smoke layer reached the floor in the engine room. In addition, as the side vent size increased, the mass flow rate through the vent increased with decreasing temperature value. However, the effects of the ceiling duct location on the smoke behavior, mass flow rate through the vent, and temperature seemed to be relatively minor compared to those of the side vent size. Therefore, to improve the fire safety of the engine room in a small ship, the side vent size is considered to be a more important design factor than the ceiling duct location.

Experimental Study on the Effect of the Area Ratio between Shaft and Tunnel and Heat Release Rate on the Plug-holing Phenomena in Shallow Underground Tunnels (저심도 도로터널에서 터널과 수직환기구의 단면적 비와 열방출률이 Plug-holing 현상에 미치는 영향에 관한 실험연구)

  • Hong, Kibea;Na, Junyoung;Ryou, Hong Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.619-625
    • /
    • 2019
  • It is difficult to design because of the plug-holing phenomenon in which the amount of smoke discharged from the vertical vent is smaller than the designed amount of smoke. In this study, the effect of cross-sectional area ratio of tunnel and natural ventilation and heat release rate of fire source on plug-holing phenomenon occurring in natural ventilation system was experimentally analyzed. In the experiment model reduced to 1/20 size, the aspect ratio of the tunnel and the vertical vent was fixed, and the influence on the plug-holing phenomenon was confirmed by varying the sectional area ratio of the tunnel and the vertical vent. Experimental results show that the plug-holing phenomenon is caused by the comparison of the smoke boundary layer temperature with the temperature in the vertical vents, and the flow and temperature distribution characteristics under the vertical vents are changed as the cross-sectional area ratio of the tunnel and vertical vents increases. The plug-holing phenomenon is affected by the cross-sectional area ratio between the tunnel and the vertical ventilation. The greater the cross-sectional area ratio, the greater the probability of plug-holing.

Assessment of the Habitability for a Cabinet Fire in the Main Control Room of Nuclear Power Plant using Sensitivity Analysis (민감도 분석을 이용한 원전 주제어실의 케비닛 화재에 대한 거주성 평가)

  • Han, Ho-Sik;Lee, Jae-Ou;Hwang, Cheol-Hong;Kim, Joosung;Lee, Sangkyu
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.52-60
    • /
    • 2017
  • Numerical simulations were performed to evaluate the habitability of an operator for a cabinet fire in the main control room of a nuclear power plant presented in NUREG-1934. To this end, a Fire Dynamics Simulator (FDS), as a representative fire model, was used. As the criteria for determining the habitability of operator, toxic products, such as CO, were also considered, as well as radiative heat flux, upper layer temperature, smoke layer height, and optical density of smoke. As a result, the probabilities of exceeding the criteria for habitability were evaluated through the sensitivity analysis of the major input parameters and the uncertainty analysis of fire model for various fire scenarios, based on V&V (Verification and Validation). Sensitivity analyses of the maximum heat release rate, CO and soot yields, showed that the habitable time and the limit criterion, which determined the habitability, could be changed. The present methodology will be a realistic alternative to enhancing the reliability for a habitability evaluation in the main control room using uncertain information of cabinet fires.