• 제목/요약/키워드: Smoke Spread

검색결과 124건 처리시간 0.023초

철도차량 및 지하철 불연 내장재 페놀 SMC 개발 (Development of Phenolic SMC for The Rail)

  • 김영근;신동혁;김영민;박종욱;민재준
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 춘계학술발표대회 논문집
    • /
    • pp.55-58
    • /
    • 2004
  • Phenolin resin, prepared form phenol and formaldehyde, is one of the oldest thermosetting resins available. Phenolic resins are cured via condensation polymerization with evolution of water, which in molding process is a big problem. The use of phenolic resins in glass fiber composites is growing, primarily due to their low flame spread, low smoke generation and low smoke toxicity properties. SMC of phenolics has been rearched since the 1986. The technology challenge was to match resin viscosity, handling and cure with those for the polyester SMC to avoid any special processing for fabricators and end users. Phenolic SMC was chosen because of the ease of molding to the required shape with light- weight, thin wall structure and with excellent fire protection.

  • PDF

화재시뮬레이션(FDS)을 이용한 Double Skin 연소확대 위험에 관한 고찰 (Analysis for Fire Spread through Double Skin Facade System with FDS)

  • 허윤택;박창복;성준식;윤명오
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.110-116
    • /
    • 2009
  • 본 연구는 Double Skin System의 화재 전파 위험성을 전산유체역학모델인 FDS를 이용하여 평가하였다. 화재모델링을 구현하기 위해 오피스 용도의 단위 구획공간을 화재지역으로 선정하였으며, 화재시나리오는 외창으로의 연소확대 위험 분석을 위하여 일반적으로 많이 설치되는 시스템조건들을 Case로 선정하여 분석하였다. 본 연구의 목적은 일반적으로 많이 사용되는 Double Skin System의 설치 간격에 따른 건물상층부로의 화재확대 위험성을 평가하고, 이에 따른 방화대책 등을 수립하는데 있다. 해석 결과, 더블스킨 중간층 간격이 넓을수록 상부층으로 연소확대 영향이 작은 것을 확인할 수 있었으며, 중간층 간격이 1m 미만인 경우는 발화층 상부 2개층으로 연소확대가 예상되므로 층간연소 확대 방지 시스템이 요구됨을 알 수 있다.

외장재에 의한 동시다발적인 화재의 피난위험성에 관한 연구 (A Study on the Evacuation Risk of Simultaneous Fires from Exterior)

  • 민세홍
    • 한국화재소방학회논문지
    • /
    • 제26권4호
    • /
    • pp.48-54
    • /
    • 2012
  • 외장재의 수직화재에 의한 동시다발적인 화재 발생 시 피난위험성을 확인하기 위하여 시나리오에 의한 피난시뮬레이션을 수행하였다. 피난시뮬레이션 결과, 가연성 외장재가 연소하면서 수직화재로 확대되어 개구부를 통해 유입되는 화재에 의해 층 대부분이 550초에서 650초 사이에 허용피난안전시간에 도달하였고, 특히 1층은 358초에, 6층과 10층은 490초와 473초에 피난한계에 도달하였다. 또한, 1층과 26층, 28층~30층의 총 5개 층에서 피난위험성이 나타나는 것으로 분석되었다. 동시다발적인 화재성상으로 인해 모든 재실자가 전관 피난을 하여 15층 이상의 고층 부분에서 병목현상이 심하게 발생하여 피난계단으로 진입이 어렵다는 것을 확인하였다. 특히, 1층의 경우는 발화지점과 가까워서 358초에 허용안전피난시간에 도달하여 상부층에 있는 699명의 피난이 난해한 것으로 분석되었다. 외장재 화재의 위험성 대책으로 불연성 외장재의 사용과 연소 확대를 방지하기 위한 적극적인 진압방법의 도입이 요구된다.

종류식 환기 시스템에서 임계속도 도달 전 스모크 확산 영역에 관한 실험적 연구 (An experimental study on the smoke-spread region before reaching the critical velocity for the case of fires in tunnels employing longitudinal ventilation system)

  • 김영민;윤성욱;윤찬훈;김진
    • 터널과지하공간
    • /
    • 제16권6호
    • /
    • pp.526-535
    • /
    • 2006
  • 본 연구에서는 장대터널 화재 시 발생하는 스모크의 거동특성을 파악하기 위해 축소모형실험을 실시하였다. Froude 상사를 기초로 실제 터널을 1/50로 축소한 20 m 의 아크릴 터널 모형을 제작하였으며, 파라핀 기체로 만든 스모크를 터널 내부에 주입시킴으로써 20MW의 실제 화재를 모사하였다. 실험에서 화재 발생 약 2분 후에 스모크는 부력효과의 감소로 아래로 하강하였으며, 제트팬 가동 전까지 4분 동안 스모크는 약 90 m를 이동하였다. 제트팬이 가동되고 기류속도가 임계속도 (도로터널 화재 중 발생하는 스모크의 역기류를 제압하기 위한 최소 공기속도)에 가까워질수록 스모크의 제어가 효율적으로 이루어지며, 스모크의 분포는 화원에서 약 3 m 정도로 더 이상 탈출 방향으로의 스모크 전파가 이루어지지 않았다. 하지만, 제트팬 가동 초기에 스모크의 제어가 거의 이루어지지 않음을 보였고 오히려 이 단계에서 탈출자의 호흡선 차단 등의 위험요소가 내재되어 있음을 알 수 있었다.

해저터널 열차 화재 시 구난역 에어커튼 시스템의 성능에 관한 실험 연구 (Experimental study on applicability of Air-Curtain system in train fire at subsea tunnel rescue station)

  • 박병직;신현준;유용호;박진욱;김휘성;김양균
    • 한국터널지하공간학회 논문집
    • /
    • 제20권1호
    • /
    • pp.1-9
    • /
    • 2018
  • 터널 화재는 밀폐된 공간에서 발생하기 때문에 시야 확보가 매우 어려우며, 빠른 속도로 연기가 차오르기 때문에 대형재난사고로 이어질 수 있다. 본 연구에서는 해저터널 열차 화재 시 구난역을 안전하게 사용하기 위하여 에어커튼 및 가압송풍기를 구난역 플랫폼에 설치하고 실물화재실험을 통하여 에어커튼 시스템의 적용성을 확인하였다. 실제 규모의 구난역에 에어커튼 시스템을 설치하였으며, 화원으로 사용한 액체 햅탄이 전소될 때까지 약 2분 동안 실험을 진행하였다. 에어커튼 시스템이 작동한 경우에는 구난역 플랫폼의 온도와 외부의 온도는 약 $160^{\circ}C$ 차이가 발생하였으며, 에어커튼 시스템이 작동한 경우에 구난역 플랫폼 내부의 일산화탄소는 작동하지 않은 경우의 구난역 플랫폼 내부와 비교하여 약 160 ppm 적게 일산화탄소가 측정되었다. 따라서 본 실물화재 실험을 통하여 해저터널 구난역 에어커튼 시스템이 화재로부터 발생한 열기와 유독가스를 차단할 수 있음을 확인하였다.

지하철 역사 및 전동차 광고물의 연소특성 조사 (Flammability case study of the subway investing materials)

  • 이덕희;이철규;정우성;김선옥;백민;조희기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.132-137
    • /
    • 2005
  • In this study we investigated the materials which locate in the subway station and train cars. We checked the flammability of the materials such as the signboard, newspaper, wide color film etc. We reported some kind of the data such as oxygen index, optical smoke density, surface flame spread speed for that materials. We hope this data will be help to decide the guideline for such materials.

  • PDF

방화Damper의 성능기준 고찰 (Investigation of Performent Standards for the Fire Damper)

  • 조중달
    • 방재기술
    • /
    • 통권12호
    • /
    • pp.10-17
    • /
    • 1992
  • Dampers which being installad in air duct are Valume damper, fire damper, leakage rated damper, but among them fire damper and leakage rated damper are used for preventing the spread of flame, hot gas and smoke through the duct. this report is aimed to intorduce the test example of the multiple fire damper which was conducted F.I.L.K, simuetaneously to investigate the performent standards and Structure of the fire damper which settled in several countries.

  • PDF

철도차량용 FRP 내장재의 화재안전성 평가 (Fire Safety Characteristics of the FRP composites for railcar)

  • 이덕희;정우성;김용기;김선옥
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(II)
    • /
    • pp.962-968
    • /
    • 2002
  • In this study we reported the Smoke Density, the Toxicity, the Flame Spread Characteristics and the Oxygen Index of the FRP composite interior panels for raicars. Also investigated the test codes of the concerning items of other countries. We made some samples to the variance of resin types, surface finishing methods and panel shapes. It's not the really used ones but may help us effectively to guess the fire safety characteristics of railcars.

  • PDF

공간적 특성에 따른 화재 확산 예측 및 실시간 대피 시스템 연구 (Prediction of Fire Spread and Real-Time Evacuation System according to Spatial Characteristics)

  • 안남기;이건희;김민정;김규호
    • 문화기술의 융합
    • /
    • 제9권4호
    • /
    • pp.617-623
    • /
    • 2023
  • 지난 10년간 우리나라에서 발생한 화재 사건 중 건물 화재가 가장 많고 재산과 인명 피해가 가장 많다. 하지만 기존 소방 시스템은 비상구 위치만 알려주고 안전한 경로를 안내해 사상자들이 원활하게 대피할 수 있도록 도와주지는 않는다. 공간적 특성을 이용하여 수직적 특성과 수평적 특성을 구분하여 성공적인 대피를 돕는 시스템을 제안하였다. 본 연구에서는 온도 감지 센서와 연기 센서 값을 이용하여 화재를 예측하고, Dijkstra 알고리즘을 통해 최적의 대피 경로를 계산하여 효과적인 대피 시스템을 제안하였다.

터널 화재시 연기확산 차단을 위한 양방향 토출 에어커튼 시스템에 대한 연구 (The Study on the Bi-directional Ejection Air Curtain System for Blocking Smoke Diffusion in case of Tunnel Fire)

  • 양상호;최영석;김정엽;김남구;김경엽
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.43-53
    • /
    • 2014
  • This paper presents a the study on air curtain system of top and bottom bi-directional jet air discharge for blocking the spread of smoke in case of tunnel fire. The five kinds different air curtains of A, B, C, D, and E of models for various performance tested after manufactured. A results of the various performance test obtained the best efficiency from E model air curtain. And optimize the injection angle of the air curtain nozzle through the three-dimensional computational fluid dynamics (CFD) analysis and analyzed the effects of external pressure of tunnel. and also single factor design have been applied. At present, our attention is focused on the velocity distribution(flow width and flow position) of 1.5m on the ground in tunnel. Also, analyzed the influence of draft in the tunnel. Detailed effects of discharge angle of air curtain and velocity at nozzle exit are discussed.