• Title/Summary/Keyword: Smoke Simulation

Search Result 256, Processing Time 0.025 seconds

Vortex Particle Turbulence for Fluid Simulation (유체 시뮬레이션의 격자 내 상세도 향상을 위한 와류 입자 혼합 기법)

  • Yoon, Jong-Chul;Hong, Jeong-Mo;Kim, Chang-Hun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.14 no.4
    • /
    • pp.1-5
    • /
    • 2008
  • In this paper, we propose an efficient technique for improving the grid based fluid simulation by sub-grid visuals. The detailed turbulency generated efficiently by Vortex Particle Method are blended with the flow fields coming from the traditional incompressible Navier-Stokes solver. The algorithm enables large- and small- scale detail to be edited separately.

  • PDF

Simulation study of smoke spread prevention using air curtain system in rescue station platform of undersea tunnel (해저터널 구난역 플랫폼 화재연기확산 방지를 위한 에어커튼 시스템 차연성능 시뮬레이션 연구)

  • Park, Sang-Heon;An, Jung-Ju;Han, Sang-Ju;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.257-266
    • /
    • 2015
  • This study introduce that we studied optimization and possibility of smoke spread prevention with air-curtain system in undersea tunnel named from Ho-Nam to Jeju line in domestic if a fire break out in train. To verify performance, air-curtain system is installed between rescue station platform and each door of passenger car to provide safety route to evacuator and we studied simulation model of various cases about 15 MW fire severity considering domestic specifications. As a result we verified the fact that CASE1(air jet with 15degree toward passenger car) and CASE 5 (air jet with 15degree toward passenger car and pressure air blast from cross passage) is best Smoke Spread Prevention and less inflow carbon monoxide. Through above results, we expect that air-curtain system is one of the facilities for fire safety and provide us safety platform route in undersea tunnel.

Realtime Fire Simulation and Rendering on Mobile Environment (모바일 환경에서 불꽃의 실시간 시뮬레이션과 렌더링)

  • Woo, Sang-Hyuk;Jo, Mi-Ri-Na;Park, Dong-Gyu
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.7
    • /
    • pp.934-943
    • /
    • 2007
  • This paper presents a real-time fire simulation on the mobile phone using stable fluid animation techniques. Stable and fast fluid simulation methods are developed in PC and console games, but fluid simulation and interactive fluid models require too much system resources for applying on mobile environment. We studied and implemented physics-based models for fluids like fire and smoke effects using billboard and stable fluids simulation method on mobile 3D system. The mobile platform of our system is WIPI, which is the standard mobile platform in Korea, also we adopted NF3D API for our 3D programming API. We implemented real-time fire simulation and added it in mobile 3D game, "Rupee Story".

  • PDF

Wind flow over sinusoidal hilly obstacles located in a uniform flow

  • Lee, Sang-Joon;Lim, Hee-Chang;Park, Ki-Chul
    • Wind and Structures
    • /
    • v.5 no.6
    • /
    • pp.515-526
    • /
    • 2002
  • The wind flow over two-dimensional sinusoidal hilly obstacles with slope (the ratio of height to half width) of 0.5 has been investigated experimentally and numerically. Experiments for single and double sinusoidal hill models were carried out in a subsonic wind tunnel. The mean velocity profiles, turbulence statistics, and surface pressure distributions were measured at the Reynolds number based on the obstacle height(h=40 mm) of $2.6{\times}10^4$. The reattachment points behind the obstacles were determined using the oil-ink dot and tuft methods. The smoke-wire method was employed to visualize the flow structure qualitatively. The finite-volume-method and the SIMPLE-C algorithm with an orthogonal body-fitted grid were used for numerical simulation. Comparison of mean velocity profiles between the experiments and the numerical simulation shows a good agreement except for the separation region, however, the surface pressure data show almost similar distributions.

A Study on the Arson Fire Char-acteristics based on Computer Simulation (컴퓨터 시뮬레이션에 의한 방화화재 특성에 관한 연구)

  • Choi, Jin
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2007.11a
    • /
    • pp.239-253
    • /
    • 2007
  • With the development of the Korean economy, the number of arson fire has been radically increased and become a huge problem and issue in Korea Society for last several decades. This study is to establish the fire life safety strategy regarding the arson fire through performing the computer simulation based on fire scenarios with researching domestic fire statistics and cutting edge techniques and methods for fire characteristics and fire dynamic. In addition, to design the fire life safety strategy depending on the arson fire pattern, the flow and characteristics of fire flames and smoke is analyzed by the computer modeling.

  • PDF

A study on the rescue design of passengers for railway tunnel fire accidents by using simulation program (터널 화재발생시 시뮬레이션 프로그램을 통한 승객대피계획)

  • Kwon, Soon-Sub;Lee, Jong-Sun;Lee, Kwan-Ho;Kwon, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1770-1773
    • /
    • 2007
  • Fire accident in tunnel is one of the most critical railway accidents, together with overturning of train by derailment and train crash. Tunnel structures contribute to minimize the cost and time of transport, but in case of railway fire accident occurring bring serious damages of human life caused by narrowness of shelter, poisonous smoke and high temperature raised at the inside of tunnel. For that reason, at the beginning of plan of tunnel, the optimum design for rescue of passengers is needed. For the detail and most suitable design for rescue of passengers, many tunnel designer substituted simulation program for mock examination by its high cost and effort. In this study, simulation program techniques, such as Fluent and Simulex, are applied for verifying the rescue design of passengers reduced the risk when fire accident occurred at tunnel utilizing of case study for planned railway tunnels shows 1,245m length in Iksan-Sili area.

  • PDF

A study of evacuation time in a subway carriage fire (지하철 객차 화재발생시 피난 시간에 대한 연구)

  • Kim, Seong-Ryul;Roh, Jae-Seong;Ro, Kyoung-Chul;Ryou, Hong-Sun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1313-1318
    • /
    • 2007
  • Recently, the terror frequently has taken place for unspecified individuals as modern society is complicated. Especially, in case of a subway carriage fire as Daegu subway fire, because smoke spread path usually coincide with passenger's evacuation path, it will reduce visibility and can cause fatalities by asphyxiation. This study performs not only fire simulation with CFAST V6 but also evacuation simulation with EXODUS V4 for the purpose of taking measures for passengers's life safety in subway fire. As a result of evacuation simulation without fire, evacuation times are 36 s for EXODUS V4 and simple hand calculation, and when fire is occurred fire, 101 persons evacuated in 32 s. Therefore, a countermeasure of evacuation in subway carriage fire is required to repression of fire and emergency exit.

  • PDF

A Study on the Arson Fire Characteristics based on Domestic Fire Statistics and Computer Simulation (국내화재통계 및 컴퓨터 시뮬레이션에 의한 방화화재 특성에 관한 연구)

  • Choi, Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • With the development of the Korean economy, the number of arson fire has been radically increased and become a huge problem and issue in Korea Society for last several decades. This study is to establish the fire life safety strategy regarding the arson fire through researching domestic fire statistics and performing the computer simulation based on fire scenarios with cutting edge techniques and methods for fire characteristics and fire dynamic. In addition, to design the fire life safety strategy depending on the arson fire pattern, the flow and characteristics of fire flames and smoke are analyzed by the computer modeling.

A Study on Securing Safety for High Rise Building Fires - Applying Active Fire Escape Systems -

  • Myung Sik, Lee;Sung Jae, Han
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.3
    • /
    • pp.227-240
    • /
    • 2022
  • Under the Korean Enforcement Decree of the Building Act, all high story apartment houses more than 5 stories high are mandated to install a fire evacuation system to ensure safe evacuation from fire accidents and providing quick and easy bidirectional escape route when main entrance is blocked by flame or toxic smoke. However, the current fire evacuation system shows a lack of understanding from residents and thus is widely ignored for having insufficient safety functions, especially vis-à-vis fire emergencies. Studies have found that an alternative evacuation method, the escapable fire evacuation system, has been analyzed for safety evaluation compared with the conventional passive fire escape system and can bring efficient and safer solutions, providing high rise residents escape from fire accidents. Evaluation for safety evacuation has been performed by the Fire Dynamics Simulation and applying Pathfinder simulation. This resulted in providing appropriate escape routes within the safety escape time and allowed for people in high rise building fires to get to safety.

Examination on Numerical Simulation Using Reduced-scale Model of Theater Fire: Influences of Fire Curtain and Stage Natural Vent (공연장 화재 축소모형을 이용한 전산시뮬레이션 검토: 방화막 및 무대부 자연배출구 영향)

  • Yang, Ji Hyun;Baek, Seon A;Lee, Chi Young;Kim, Duncan
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.37-47
    • /
    • 2019
  • In the present study, the influences of the fire curtain and natural vent in a theater fire were investigated through the numerical simulation of a reduced-scale model of a theater fire using the Fire Dynamics Simulator (FDS). Based on a previous experimental study using the reduced-scale model, the 1/14 reduced-scale model and its conditions were constructed according to the law of similarity with a real-scale theater. Through a series of numerical simulations, the smoke movements were visualized, and the temperatures in the stage and auditorium, mass flow rate of the outflow through natural vent, and time at which smoke started moving toward the auditorium were measured and analyzed. The general trends on the effects of the fire curtain and natural vent during the theater fire predicted by the present numerical simulation were similar to the previous experimental results. For quantitative comparison of the present numerical simulation and previous experimental results, the mean percentage errors of temperatures in the stage and auditorium, and the mass flow rate of outflow through the natural vent were calculated. The present numerical simulation results showed good agreement with previous experimental results with reasonable accuracy.