• Title/Summary/Keyword: Smoke Particle

Search Result 79, Processing Time 0.026 seconds

Vortex Particle Turbulence for Fluid Simulation (유체 시뮬레이션의 격자 내 상세도 향상을 위한 와류 입자 혼합 기법)

  • Yoon, Jong-Chul;Hong, Jeong-Mo;Kim, Chang-Hun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.14 no.4
    • /
    • pp.1-5
    • /
    • 2008
  • In this paper, we propose an efficient technique for improving the grid based fluid simulation by sub-grid visuals. The detailed turbulency generated efficiently by Vortex Particle Method are blended with the flow fields coming from the traditional incompressible Navier-Stokes solver. The algorithm enables large- and small- scale detail to be edited separately.

  • PDF

Particle System Graphics Library for Generating Special Effects

  • Kim Eung-Kon
    • International Journal of Contents
    • /
    • v.2 no.2
    • /
    • pp.1-5
    • /
    • 2006
  • The modeling and animation of natural phenomena have received much attention from the computer graphics community. Synthetic of natural phenomena are required for such diverse applications as flight simulators, special effects, video games and other virtual realty. In special effects industry there is a high demand to convincingly mimic the appearance and behavior of natural phenomena such as smoke, waterfall, rain, and fire. Particle systems are methods adequate for modeling fuzzy objects of natural phenomena. This paper presents particle system API(Application Program Interfaces) for generating special effects in virtual reality applications. The API are a set of functions that allow C++ programs to simulate the dynamics of particles for special effects in interactive and non-interactive graphics applications, not for scientific simulation.

  • PDF

A Study on the interface of information processing system on Human enhancement fire fighting helmet (휴먼 증강 소방헬멧 정보처리 시스템 인터페이스 연구)

  • Park, Hyun-Ju;Lee, Kam-Yeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.497-498
    • /
    • 2018
  • In the fire scene, it is difficult to see 1m ahead because of power failure, smoke and toxic gas, even with thermal imaging camera and Xenon searchlight. Analysis of the smoke particles in the fire scene shows that even if the smoke is $5{\mu}m$ or less in wavelength, it is difficult to obtain a front view when using a conventional thermal imaging camera if the visual distance exceeds 1 meter. In the case of black smoke with a particle wavelength of $5{\mu}m$ or more, a space permeation sensor technology using various sensors other than a single sensor is required because chemical materials, gas, and water molecules are mixed. Firefighters need a smoke detection technology for smoke detection and spatial information visualization for forward safety view.In this paper, we design the interface of the information processing system with 32bit CPU core and peripheral circuit. We also implemented and simulated the interface with Lidar sensor. Through this, we provide interface that can implement information processing system of human enhancement fire helmet in the future.

  • PDF

Characterization of fine organic aerosols from biomass burning emissions using FTIR method (분광학적 방법을 이용한 바이오매스 연소 배출 유기 입자의 화학적 특성)

  • Son, Se-Chang;Park, Tae-Eon;Park, Seungshik
    • Particle and aerosol research
    • /
    • v.17 no.4
    • /
    • pp.125-132
    • /
    • 2021
  • Fresh PM2.5 smokes emitted from combustion of four biomass materials (pellet, palm fruit fiber (PFF), PKS, and sawdust) in a laboratory-controlled environment were characterized using an attenuated total reflectance-fourier transform infrared (ATR-FTIR) technique. In smoke samples emitted from combustion of pellets, PFF and PKS, which is being used as boiler fuels for greenhouses in rural areas, the organic carbon/elemental carbon (OC/EC) ratios in PM2.5 were very high (14.0-35.5), whereas in sawdust smoke samples they were significantly low (<4.0) due to the combustion method close to flaming combustion. ATR-FTIR analysis showed that OH(3400-3250 cm-1), CH3(2958-2840 cm-1), CH2(2910 cm-1 and 2850 cm-1), ketone(1726-1697 cm-1), C=C(1607-1606 cm-1 and 1515-1514 cm-1), lignin (1463-1462 cm-1 and 1430-1428 cm-1) and -NO2(1360-1370 cm-1) peaks were identified in all biomass burning (BB) smoke samples. However, additional peaks appeared depending on the type of biomass. Among the four types of biomass materials, an additional peak of the methylene group CH3(2872-2870 cm-1) appeared only in PFF and PKS smoke samples, and a peak of C=O(1685 cm-1) was also confirmed. And in the case of PKS smoke samples, a peak of aromatic C=C(1593 cm-1 and 1476 cm-1) that did not appear in other BB samples was also observed. This indicates that the molecular structure of organic compounds emitted during BB differs depending on the type of biomass materials. The results of this study are expected to provide valuable information to more specifically reveal the effect of BB on PM2.5 collected in the atmospheric environment.

Smoke Characteristics of a Small Scale Pool Eire (작은 풀화재에서의 연기 특성)

  • Lee Eui-Ju;Ahn Chan-Sol;Shin Hyun-Joon;Oh Kwang-Chul;Lee Uen-Do
    • Fire Science and Engineering
    • /
    • v.19 no.3 s.59
    • /
    • pp.58-63
    • /
    • 2005
  • Experimental measurements of flames and the product properties were performed for small kerosene pool fires. which is widely used as a fire source of laboratory scale experiments with scaling modeling. The flame length and flickering frequency were investigated for the flame structures, and compared with the theory. Three measurement methods were introduced to clarify the smoke characteristics, i.e. various gas concentrations, smoke density and thermophoretic sampling with transmission electron microscopy (TEM). The yield of carbon dioxide and the consumption of oxygen were proportional to the heat release rate of pool fires, but there is no trend on carbon monoxide emission. Smoke density of turbulent flames was exponentially increased with the heat release rate. The morphology of the soot particle was investigated to address the degree of soot maturing. The results show that the similar smoke morphology between an inverse jet flame and a pool fire exists despite of different combustion controlling mechanisms.

PREVENTION OF CIGARETTE SMOKE INDUCED LUNG CANCER BY LOW LET IONIZING RADIATION

  • Sanders, Charles L.
    • Nuclear Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.539-550
    • /
    • 2008
  • Lung cancer is the most prevalent global cancer, ${\sim}90%$ of which is caused by cigarette smoking. The LNT hypothesis has been inappropriately applied to estimate lung cancer risk due to ionizing radiation. A threshold of ${\sim}1\;Gy$ for lung cancer has been observed in never smokers. Lung cancer risk among nuclear workers, radiologists and diagnostically exposed patients was typically reduced by ${\sim}40%$ following exposure to <100 mSv low LET radiation. The consistency and magnitude of reduced lung cancer in nuclear workers and occurrence of reduced lung cancer in exposed non-worker populations could not be explained by the HWE. Ecologic studies of indoor radon showed highly significant reductions in lung cancer risk. A similar reduction in lung cancer was seen in a recent well designed case-control study of indoor radon, indicating that exposure to radon at the EPA action level is associated with a decrease of ${\sim}60%$ in lung cancer. A cumulative whole-body dose of ${\sim}1\;Gy$ gamma rays is associated with a marked decrease in smoking-induced lung cancer in plutonium workers. Low dose, low LET radiation appears to increase apoptosis mediated removal of $\alpha$-particle and cigarette smoke transformed pulmonary cells before they can develop into lung cancer.

Deflective Behavior of Charged Particles in a Two-Stage Electrostatic Precipitator

  • Lim, Hun-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.83-91
    • /
    • 2011
  • Even if smoke, fumes, mist or dust particles are removed by electrostatic precipitators (ESPs), the occurrence of ozone, which is harmful to human body, has to be severely restricted in the indoor environments of hospitals, offices, and workshops. Therefore, the two-stage ESP generating positive corona at the ionizer is typically used because it creates less ozone than the two-stage ESP generating negative corona at the ionizer. In order to predict the collection performance and the optimal design of the two-stage ESP applied to positive high-voltage, particle concentration is experimentally investigated in this paper. In addition, particle motion within the collector section is also numerically analyzed. The positive corona discharge current of the ionizer is found to be affected by the applied voltage in the collector section but less so by the particle concentration. Particle concentration shows a minimum near the high voltage electrode of the collector section. The minimum value of the collection efficiency is almost proportional to gas velocity. When the collector length decreases, the minimum value of the collection efficiency increases. Charged particles entering the collector region are linearly deflected towards the grounded plate by an electric field. From the above experimental and numerical results, two empirical equations on the concentration ratio and the collection efficiency are derived, and are in good agreement with the experimental data.

Efficiency of the Hybrid-type Air Purifier on Reducing Physical and Biological Aerosol (복합식 공기청정기의 물리적 및 생물학적 입자상 물질의 제거 효과)

  • Kim, Ki-Youn;Kim, Chi-Nyon;Kim, Yoon-Shin;Roh, Young-Man;Lee, Cheol-Min
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.478-484
    • /
    • 2006
  • There was no significant difference in the CADR (Clean Air Delivery Rate) between physical aerosols, NaCl and smoke, and biological aerosols, airborne MS2 virus and P. fluorescens, which implicate that the hybrid-type of air purifier, applying the unipolar ion emission and the radiant catalytic ionization, imposed identical reduction effect on both physical aerosol and bioaerosol. Ventilation decreases the efficiency of air cleaning by unipolar ionization because high ventilation diminishes the particle concentration reduction effect. The particle removal efficiency decreases with increase in the chamber volume because of the augmented ion diffusion and higher ion wall loss rate. Particle size affects the efficiency of air ionization. The efficiency is high for particles with very small diameter because reduction of charge increases with particle size. If there is no increasing supply of ions, the efficiency of air cleaning by unipolar ionization increases with respect to initial concentration of particles because of the large space charge effect at high particle concentration and amplified electric field.

A Review on Swirling Flow by Using Flow Visualization Techniques in the Circular Tubes (원형관 내에서 유동가시화 기법을 이용한 선회유동에 관한 연구고찰)

  • Chang, Tae-Hyun;Doh, Deog-Hee;Lee, Kwoon-Soo
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.3
    • /
    • pp.12-21
    • /
    • 2010
  • Swirling flows are found in very wide range of applications, for examples, cyclone separators, spraying machines, heat exchangers and jet pumps, ect. Relatively, little work has been done on the swirl flow using flow visualization techniques. This study deals with many visualization techniques to study on swirling flow. These techniques are related to oil films methods, smoke, dye liquids, liquid crystal, stroboscope light, smoke wire, white light, naphthalene sublimation, LDV(lase doppler Velocimetry) and PIV(particle image velocimetry). The present work has handled single, annular, carved tube, swirl expansion and swirl wake using several visualization methods in the vertical and horizontal circular tube.

A Study on the Performance Improvement of Diesel Automobile Engine with Ultrasonic Fuel Feeding System(II)-On the Spray Characteristics and Engine Performance- (초음파 연료분사장치용 디젤자동차의 성능향상에 관한 연구(II)-분무특성과 기관성능에 대하여-)

  • Yang, J.K.;Jung, J.D.;Ryu, J. I.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.6
    • /
    • pp.50-56
    • /
    • 1994
  • This is an experimental study on the performance characteristics of Diesel Automobile with ultrasonic fuel feeding system. For this purpose, ultrasonic fuel feeding system was made and atomization characteristics was measured. Base on this result, carried out engine dynamometer test to investigate the performance characteristics of diesel automobile with ultrasonic fuel feeding system in comparison with conventional diesel fuel injector. The results are as follows. 1) In the spray characteristics test, fuel particle sizes were decreased about 11%~21%. 2) In engine dynamometer test, -The power was increased about 5%~11%. -The thermal efficiency was improved about 6%~11%. -The specific fuel consumption was improved about 6%~19%. -The smoke concentration was decreased about 11%~50%.

  • PDF