• 제목/요약/키워드: Smart transformer

검색결과 66건 처리시간 0.019초

단상 NPC Module- 3직렬 Cascade 구성 방식의 75KVA급 단상 지능형 변압기 개발 (Single Phase NPC Module - Development of 75KVA Single Phase Smart Transformer with 3 Serial Cascade Configuration)

  • 박주영;니이테게카;조경식;김명룡;박가우
    • 전력전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.118-125
    • /
    • 2017
  • In this paper, we propose a smart transformer for a smart transformer miniature model, which can replace a 60 [Hz] single-phase transformer installed in an electric vehicle. The proposed smart transformer is lighter than a conventional transformer, can control instantaneous voltage, and can be expected to improve power quality through harmonic compensation. The proposed intelligent transformer consists of an incoming part, an AC/DC converter, and a dual active bridge. Only the incoming part and the AC/DC converter are described in this paper. The proposed intelligent transformer has 75 kVA 3.3 kV input and 750 V DC output, which are verified by simulation and experiment.

A High-Efficiency CMOS Power Amplifier Using 2:2 Output Transformer for 802.11n WLAN Applications

  • Lee, Ockgoo;Ryu, Hyunsik;Baek, Seungjun;Nam, Ilku;Jeong, Minsu;Kim, Bo-Eun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권2호
    • /
    • pp.280-285
    • /
    • 2015
  • A fully integrated high-efficiency linear CMOS power amplifier (PA) is developed for 802.11n WLAN applications using the 65-nm standard CMOS technology. The transformer topology is investigated to obtain a high-efficiency and high-linearity performance. By adopting a 2:2 output transformer, an optimum impedance is provided to the PA core. Besides, a LC harmonic control block is added to reduce the AM-to-AM/AM-to-PM distortions. The CMOS PA produces a saturated power of 26.1 dBm with a peak power-added efficiency (PAE) of 38.2%. The PA is tested using an 802.11n signal, and it satisfies the stringent error vector magnitude (EVM) and mask requirements. It achieves -28-dB EVM at an output power of 18.6 dBm with a PAE of 14.7%.

Incorporating BERT-based NLP and Transformer for An Ensemble Model and its Application to Personal Credit Prediction

  • Sophot Ky;Ju-Hong Lee;Kwangtek Na
    • 스마트미디어저널
    • /
    • 제13권4호
    • /
    • pp.9-15
    • /
    • 2024
  • Tree-based algorithms have been the dominant methods used build a prediction model for tabular data. This also includes personal credit data. However, they are limited to compatibility with categorical and numerical data only, and also do not capture information of the relationship between other features. In this work, we proposed an ensemble model using the Transformer architecture that includes text features and harness the self-attention mechanism to tackle the feature relationships limitation. We describe a text formatter module, that converts the original tabular data into sentence data that is fed into FinBERT along with other text features. Furthermore, we employed FT-Transformer that train with the original tabular data. We evaluate this multi-modal approach with two popular tree-based algorithms known as, Random Forest and Extreme Gradient Boosting, XGBoost and TabTransformer. Our proposed method shows superior Default Recall, F1 score and AUC results across two public data sets. Our results are significant for financial institutions to reduce the risk of financial loss regarding defaulters.

Three-Level H-Bridge 컨버터를 이용한 철도차량용 지능형 변압기의 구조 및 제어 (Structure and Control of Smart Transformer with Single-Phase Three-Level H-Bridge Cascade Converter for Railway Traction System)

  • 김성민;이승환;김명룡
    • 한국철도학회논문집
    • /
    • 제19권5호
    • /
    • pp.617-628
    • /
    • 2016
  • 본 논문은 철도차량의 추진용 유입식 변압기 및 AC/DC 컨버터를 대체하기 위한 지능형 변압기의 구조를 제안한다. 제안된 지능형 변압기는 반도체 스위칭 소자 및 고주파 변압기를 사용한 양방향 전력 변환 컨버터의 형태로써, 기존 변압기에 비해 경량화 되고, 역률 제어 등의 능동적인 제어 성능으로 인해 단상 계통 전원의 효율적인 활용을 가능하게 한다. 제안하는 지능형 변압기는 60Hz 교류 고전압을 직류 고전압으로 변환하기 위한 정류단으로 Neutral point clamped type 의 H-bridge 컨버터를 여러 개 직렬 연결해 구성했다. 직류로 변환된 입력단 전력은 고주파 변압기와 Neutral point clamped type H-bridge 컨버터 2개로 구성된 Dual-Active-Bridge 컨버터를 이용해 출력측에 필요한 저전압을 공급할 수 있도록 했다. 또한, 본 논문에서는 다수의 컨버터 모듈 내부 직류단 전압을 균형제어하며, 단상 교류 전원에서 직류 출력 전원간의 양방향 전력 제어를 가능하게 하는 제어 알고리즘을 제안한다. 제안한 지능형 변압기의 구조 및 제어 시스템은 75kVA 급 3.3kVrms 입력, 750VDC 출력의 지능형 변압기를 설계 및 회로 시뮬레이션 결과를 통해 검증했다.

Steady State Analysis for Power System of HSR with Active Transformer

  • Kim, Wook-Won;Kim, Hyung-Chul;Shin, Seung-Kwon;Kim, Jin-O
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.257-264
    • /
    • 2016
  • In this paper, new electric railway feeding system which has active transformer is modeled for evaluating the steady state analysis using PSCAD/EMTDC. Equivalent models including power supply, feeder, train and transformers are proposed for simplifying the model of the feeding system in high speed electric railway. In case study, simulation results applied to proposed model are compared with the conventional and new systems through the catenary voltage, three-phase voltage of PCC (Point of Common Coupling) and the efficiency of regenerative braking energy.

A Study on the Effective Downscaling Methodology for Design of a Micro Smart Grid Simulator

  • Ko, Yun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1425-1437
    • /
    • 2018
  • In this paper, a methodology was proposed to reduce the electrical level and spatial size of the smart grid with distributed generations (DGs) to a scale in which the electrical phenomena and control strategies for disturbances on the smart grid could be safely and freely experimented and observed. Based on the design methodology, a micro smart grid simulator with a substation transformer capacity of 190VA, voltage level of 19V, maximum breaking current of 20A and size of $2{\times}2m^2$ was designed by reducing the substation transformer capacity of 45MVA, voltage level of 23kV and area of $2{\times}2km^2$ of the smart grid to over one thousandth, and also reducing the maximum breaking current of 12kA of the smart grid to 1/600. It was verified that the proposed design methodology and designed micro smart grid simulator were very effective by identifying how all of the fault currents are limited to within the maximum breaking current of 20A, and by confirming that the maximum error between the fault currents obtained from the fault analysis method and the simulation method is within 1.8% through the EMTP-RV simulation results to the micro smart grid simulator model.

The Coordinate Control Method of LTC Transformer and Capacitor Banks at Distribution Substation

  • Choi, Joon-Ho;Ahn, Seon-Ju;Nam, Hae-Kon;Kim, Jae-Chul;Moon, Seung-Il;Jung, Won-Wook;Song, Il-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.320-329
    • /
    • 2012
  • The Load Tap Changing (LTC) transformer and Shunt Capacitor (SC) bank are major devices for voltage and reactive power control in a distribution substation. Thus, the coordination operation of a LTC transformer and a SC bank is required to achieve better voltage and reactive power compensation at a distribution substation in the same time. This paper proposes coordinate control method of LTC transformer and SC bank to achieve better voltage and reactive power compensation and operation times of these two devices in the same time. The mathematical formulations of the proposed coordinate control method are introduced. Sample case studies are shown to verify the effectiveness of the proposed coordinate control method.

철도차량용 지능형 변압기 손실 저감을 위한 Dual Active Bridge 컨버터의 Modulation 기법 연구 (Modulation Technique of Dual Active Bridge Converter to Improve Efficiency of Smart Transformers in Railroad Traction System)

  • 김성민;이승환;김명룡
    • 한국철도학회논문집
    • /
    • 제19권6호
    • /
    • pp.727-735
    • /
    • 2016
  • 철도차량용 구동 시스템의 주 변압기를 지능형 변압기로 대체하는 것은 철도차량의 효율을 높이기 위한 효과적인 방법이다. 지능형 변압기는 고전압 입력단을 저전압 직류단으로 변환하는 정류단 모듈과, 변환된 복수의 저전압 직류단 전압을 직/병렬로 연결하여 저전압 직류 출력 전압을 제어하는 Dual Active Bridge (DAB) 컨버터 모듈로 구성된다. DAB 컨버터는 고주파 변압기를 사이에 두고 양 측 Full-Bridge 컨버터의 전압 합성 방법에 따라 전력이 양방향으로 전달될 수 있다. 이 때, 양 측 Full-Bridge 컨버터의 전압 합성 방법에 따라 고주파 변압기로 흐르는 전류의 형태가 달라지게 되며, 이는 효율에 직접적인 영향을 미치게 된다. 본 논문은 중/저 전력 조건에서 DAB 컨버터의 효율을 개선하기 위한 새로운 modulation 방법을 제안한다. 제안하는 modulation 방법은 DAB 컨버터 내에 발생할 수 있는 무효 전력을 0으로 제어하도록 하며, 출력단 컨버터를 다이오드 정류기와 유사한 동작을 하도록 함으로써, 스위칭 손실을 최소화하도록 하였다. 제안된 modulation 방법을 통한 손실 저감은 900Vdc의 직류단 전압을 갖는 DAB 컨버터에 대한 시뮬레이션 결과를 통해 검증하였다.

태양광 계통연계형 하이브리드 변압기의 해석 및 성능시험 (Analysis and Performance Test of Hybrid Transformer used in the Grid-Connected Photovoltaic Generation System)

  • 김지호;박훈양;손진근
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.333-338
    • /
    • 2014
  • This paper concerns the development of the transformer that can reduce harmonics supplied to the system if the output of photovoltaic inverter in the photovoltaic system is grid-connected, and suggests that problems of harmonics and power factor degradation in the grid-connected photovoltaic system can be improved. In this study, the burden of increasing the investment in new facilities and securing their installation space due to harmonics has been substantially eased through the development of a hybrid transformer possessing unbalanced function and harmonics reduction function using zig-zag coils, and most of all, it is expected that the development of such high efficiency hybrid transformer possessing functions of transformation and reducing harmonics can improve the power quality as well as prevent damages caused by harmonics, leading to suppress unnecessary loss of electric power and thereby contribute to energy savings.

Vision Transformer를 이용한 UAV 영상의 벼 도복 영역 진단 (Diagnosis of the Rice Lodging for the UAV Image using Vision Transformer)

  • 명현정;김서정;최강인;김동훈;이광형;안형근;정성환;김병준
    • 스마트미디어저널
    • /
    • 제12권9호
    • /
    • pp.28-37
    • /
    • 2023
  • 쌀 수확량 감소에 크게 영향을 주는 것은 집중호우나 태풍에 의한 도복 피해이다. 도복 피해 면적 산정 방법은 직접 피해 지역을 방문하는 현장 조사를 기반으로 육안 검사 및 판단하여 객관적인 결과 획득이 어렵고 많은 시간과 비용이 요구된다. 본 논문에서는 무인 항공기로 촬영된 RGB 영상을 Vision Transformer 기반 Segformer을 활용한 벼 도복 영역 추정 및 진단을 제안한다. 제안된 방법은 도복, 정상, 그리고 배경 영역을 추정하고 종자관리요강 내 벼 포장 검사를 통해 도복률을 진단한다. 진단된 결과를 통해 벼 도복 피해 분포를 관찰할 수 있게 하며, 정부 보급종 포장 검사에 활용할 수 있다. 본 연구의 벼 도복 영역 추정 성능은 평균 정확도 98.33%와 mIoU 96.79%의 성능을 나타내었다.