• Title/Summary/Keyword: Small-sized buildings

Search Result 48, Processing Time 0.022 seconds

A Study on the Safety Analysis and Safety Improvement of Domestic Small Sized Buildings (국내 소규모 건축물의 현황분석 및 안전성 향상 방안 연구)

  • Kim, Dong-Il;Kang, Hwi-jin
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.2
    • /
    • pp.43-47
    • /
    • 2017
  • There is no safety accident of the class 1 and 2 facilities that have been managed by the 'Special Act on Safety Management of Facilities' in the last 22 years. Safety accidents of the small sized facilities are increasing every year because of the lack of systematic management of the facilities. The government plans to enact a small portion of small sized buildings into the class 3 facilities, enabling them to enact a safety check. In this paper, we analyze the safety management status of the class 3 facilities of buildings and propose a plan for improving the safety of small sized buildings.

Experimental Study on Seismic Performance Enhancement of Exposed Column-base Plate Strong-axis Connections for Small-Sized Steel Buildings (소규모 철골조건축물 강축방향 노출형 주각부의 내진성능 향상을 위한 실험 연구)

  • You, Young-Chan
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.12
    • /
    • pp.11-20
    • /
    • 2018
  • The purpose of this study is to investigate the seismic performance of exposed column-base plate strong-axis connections for small-sized steel buildings. Even though the seismic design for small-sized buildings became mandatory since Dec.2017, the arbitrary connection details in steel structure have been applied at the construction site, which is considered to be very insufficient to secure structural safety and stability considering the increased seismic risk. Therefore, a series of experimental test programs had been carried out to develop enhanced connection details in order to ensue the adequate seismic safety of small buildings. The hysteretic behavior of the exposed column-base plate connections commonly used in Korea seem to be very pure poor due to the "Rocking" phenomena between anchor plate and concrete by the residual plastic deformation of anchor bolts. A series of hysteretic tests were conducted to find the solution to overcome the "Rocking" phenomena of the exposed column-base plate connections, finally the stable seismic behavior was obtained by uisng at least 8 anchor bolts with good bonding strength to the protptype specimen.

A Study on the Energy Consumption Characteristics for Use and Operation Period in Office Buildings (업무용 건물의 용도 및 운전 기간별 에너지 소비 특성 연구)

  • Park, Byung Hun;Kim, Si Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.11
    • /
    • pp.605-611
    • /
    • 2017
  • The purpose of this study is to calculate the energy consumption rate based on data regarding energy use in office buildings, and to confirm the general characteristics of energy consumption. The energy consumption rate of the building is calculated by dividing the energy consumption by the floor area. The energy consumption rate of small-sized office buildings was calculated as $101.48{\sim}201.55kWh/m^2{\cdot}year$ and in the case of medium-sized buildings, the range was $92.77{\sim}177.89kWh/m^2{\cdot}year$. In the case of small buildings, it was found that the energy consumption was $73.24kWh/m^2{\cdot}year$ in electronic device, $34.31kWh/m^2{\cdot}year$ in hot water supply, and $18.37kWh/m^2{\cdot}year$ in heating. In the case of medium-sized buildings, electronic devices was $73.08kWh/m^2{\cdot}year$, lighting was $18.35kWh/m^2{\cdot}year$ and heating, $15.37kWh/m^2{\cdot}year$. In all of the study buildings, the peak heating energy use was observed from 8:00 a.m. to 10:00 a.m during the winter, and the peak power management was required. Energy use at and around the midnight hour is confirmed to be 40~60% of weekly working hours, so it is necessary to manage power use at night time as well as during the day. In order to improve the accuracy of future studies, it is necessary to make efforts to secure the data with standardized energy measuring units for the various type of buildings.

A Study of Rent Determinants of Small and Medium-Sized Office Buildings in Seoul Using a Dynamic Panel Model: Focusing on CBD and GBD Comparison (동적패널모형을 활용한 서울시 중소형 오피스 빌딩 임대료 결정 요인 연구: CBD(도심권)와 GBD(강남권) 비교를 중심으로)

  • NaRa Kim;JinSeok Yu;Jongjin Kim
    • Land and Housing Review
    • /
    • v.14 no.4
    • /
    • pp.47-62
    • /
    • 2023
  • Using the dynamic panel model, this study investigates rent determinants for small and medium-sized office buildings in Korea's CBD and Gangnam areas, key business districts. The results reveal that rents for small and medium-sized office buildings in CBD and Gangnam areas are influenced by macroeconomic fluctuations and characteristics of buildings and locations, suggesting a market with both spatial consumer and investment goods attributes. There are several investment implications as follows. First, even if the location in the CBD area is advantageous, the practical limitations in renovating aging small and medium-sized office buildings must be taken into account when investing. Second, parking conditions are a key factor influencing rent prices in CBD areas, so evaluating the parking facilities and improvement potential of small and medium-sized office buildings is essential for investors. Finally, due to the high sensitivity of Gangnam's small and medium-sized office market to macroeconomic trends, it's vital to prioritize monetary policy shifts as a key factor in investment decisions.

An Analysis for Price Determinants of Small and Medium-sized Office Buildings Using Data Mining Method in Gangnam-gu (데이터마이닝기법을 활용한 강남구 중소형 오피스빌딩의 매매가격 결정요인 분석)

  • Mun, Keun-Sik;Choi, Jae-Gyu;Lee, Hyun-seok
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.7
    • /
    • pp.414-427
    • /
    • 2015
  • Most Studies for office market have focused on large-scale office buildings. There is, if any, a little research for small and medium-sized office buildings due to the lack of data. This study uses the self-searched and established 1,056 data in Gangnam-Gu, and estimates the data by not only linear regression model, but also data mining methods. The results provide investors with various information of price determinants, for small and medium-sized office buildings, comparing with large-scale office buildings. The important variables are street frontage condition, zoning of commercial area, distance to subway station, and so on.

RC Short Column Effects on Seismic Performance of Small-Sized Buildings in Korea (국내 소규모 건축물의 단주효과에 대한 내진성능검토)

  • Kim, Kyungtae;Yoo, Chang-Hwan;Park, Kyunghoon;Kim, Taejin
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.7_spc
    • /
    • pp.545-551
    • /
    • 2016
  • This paper investigates seismic performance of a small-sized single story building in Korea. Nonlinear pushover anlaysis is performed to verify shear failure of RC short columns eventually led to performance degradation. Also, nonlinear time history analysis is performed using the same earthquakes from Gyeongju. Similar failure mode was obtained as in the report where a sudden rupture of the RC columns happened.

Seismic Performance Enhancement of Exposed Column-base Plate Weak-axis Connections for Small-Sized Steel Buildings (소규모 철골조건축물을 위한 약축방향 노출형 주각부의 내진성능 향상)

  • You, Young-Chan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.1-12
    • /
    • 2019
  • The purpose of this study is to enhance the seismic performance of exposed column-base plate weak-axis connections for small-sized steel buildings. According to the site inspection for the small-sized building construction, the arbitrary connection details in steel buildings have been applied at the job site, which is considered to be insufficient to guarantee structural safety and stability considering the increased seismic risk in Korea. Therefore, a series of test programs had been done to develop enhanced connection details in order to ensue the adequate seismic stability and safety of small-sized steel buildings. From the test results, It was found that the exposed column-base plate weak-axis connections commonly used in Korea shows very poor seismic behavior due to the "Rocking" phenomena caused by the residual plastic deformation of anchor bolts between anchor plate and concrete. A series of hysteretic tests for finding that solution were conducted to reduce the "Rocking" phenomena of the column-base plate connections, and local buckling of webs in H-column. Finally the enhanced stable seismic behavior was obtained by reinforcing at least 8 anchor bolts with good bonding strength and stiffeners to the webs in H-column.

A Study on the Image of the Private Hospital Buildings in Small and Medium-Sized Cities (중소도시 개인병원 건축물의 이미지에 관한 연구)

  • Lee, Woong-Gu
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.14 no.4
    • /
    • pp.107-116
    • /
    • 2012
  • This study aims to investigate what degree do the hospital buildings carry out their role in regional scenery. To carry out this study the existing theoretical and field survey was conducted to the 44 private hospitals in small and medium-sized cities - Jeonju city, Kunsan city and Iksan city in Jeonlabukdo district. The contents of the survey are the general aspect of the polled, the image of the buildings, that of medical treatment parts, the relations to the regional scenery. And they are questionnaire surveyed to the 44 private hospital buildings. In questionnaire survey, the 35 professional architects who major architecture and related design and 118 citizens who doesn't major architecture are participated. The results of this study are as follows: 1. Those surveyed who answered those private hospital buildings which have their functional images are barely 20%. Some of 27% answered they have images of the commercial building. Especially in professional architects, 5% of them answered thet have their hospital images. It showed that they don't have their identity in the architectural expression in the processof architectural design. 2. The architectural facade elements that express their images in surveyed buildings are answered that architectural building form is 62%, architectural color is 27% and architectural material is 10% in turn. And the architectural elements that express their images in surveyed buildings are answered that building wall is 56%, architectural decoration is 32%. In this article, the reason why the ratio of the architectural decoration is high is that they don' have their identity in building itself. And they expressed their identity by their decoration, sign system not their buildings. 3. As the preference level for their images, some of the 49% of the total surveyed answered common. The general surveyed answered a little preference. But the architect professional group answered preference is 14%, not preference is 29%. The reason of this article is that the general surveyed are familiar with their buildings. So the questionnaire of the harmony with the surrounding scenery, 25% of the general surveyed answered that they are in harmony with surrounding but 22% of them answered that they are not in them. But In professional group, they answered 6% oh them are positive 37% of them are negative. This results suggests that the identity of the private hospital buildings are established in the process of archiectural design.

Proposal of the Energy Retrofit in a Small Sized Office Building and its Application (기존 건물의 에너지 개수방법의 제안 및 사례연구)

  • Jeong, Hee-Gyu;Park, Jun-Won;Lee, Young-Jae;Song, Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.9
    • /
    • pp.663-670
    • /
    • 2012
  • Recently, energy saving in building sector is of great important to meet national $CO_2$ reduction goals in Korea. In this sense, it is crucial to improve the energy performance for existing building. The energy efficiency investments, ESCO business, can be beneficial to expand the chance of energy retrofit for existing building. However, ESCO business hardly expand in Korea because it has many limitations in guarantee for energy saving. Also, it is more difficult to apply the energy retrofit measures in existing building than new building. Therefore, the retrofitting methods for existing small-and medium-sized buildings should be improved to initiate ESCO business and expand it in Korea. In this study, the energy retrofit methods for small sized office building were suggested and the case study for a small sized office building located in Suwon was accomplished.

A Study on Energy Use Monitoring and Analysis Case for Small and Medium-Sized Buildings (중소형 건물에 적합한 에너지사용량 모니터링 및 분석 사례 연구)

  • Lee, Hye-Jin;Kim, Myung-Jin;Kim, Jin-Ho;Lee, Dongho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.5
    • /
    • pp.499-509
    • /
    • 2019
  • This paper discusses energy use monitoring and analysis as part of a study on a low-cost energy supply management system that links an existing database with weather information with no real-time monitor for energy demand of buildings using renewable energy, generator and energy storage systems. This study is targeted at small and medium-sized buildings and aims to monitor energy use with a small number of sensors at low cost by applying an energy management system (EMS). The present study can help overcome the limitations of high-cost EMS applied to large commercial and public buildings. We developed current, indoor temperature and human motion sensors and installed them in an office of a company in a sample building. Through these sensors, we analyzed energy use patterns and the effects of weather information and human motion on the energy use. Furthermore, we analyzed the correlations between the total KEPCO energy use of the sample building and weather by comparing these two data. The results showed that the office energy use of a company was more affected by human motions than by weather information. The comparison between the total energy use of the Building and weather information found that external temperature had an effect on the energy use.