• Title/Summary/Keyword: Small tank scale

Search Result 89, Processing Time 0.027 seconds

Development of Combined Septic Tank for Middle-Small Scale Sewage Treatment (중·소규모 생활오수 처리를 위한 합병정화조 개발)

  • Rim, Jay-Myoung;Han, Dong-Joon
    • Journal of Industrial Technology
    • /
    • v.17
    • /
    • pp.73-77
    • /
    • 1997
  • This study aims to develop the combined septic tank for middle-small scale sewage treatment. The developed process were circular and separate type. The circular combined septic tank was controlled sludge discharge and could be modified the advanced treatment system. The separate combined septic tank was could be applicated wastewater that discharge flow was varied, and was could be maintained F/M ratio constantly. The optimum hydraulic retention time was about 16 hours.

  • PDF

Longitudinal Modal Analysis of a LOX-filled Tank Using the Virtual Mass Method

  • Lee, SangGu;Sim, JiSoo;Shin, SangJoon;Kim, Youdan
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.4
    • /
    • pp.807-815
    • /
    • 2017
  • For liquid rocket engine(LRE)-based space launch vehicles, longitudinal instability, often referred to as the pogo phenomenon in the literature is predicted. In the building block of system-level task, accurate dynamic modeling of a fluid-filled tank is an essential. This paper attempts to apply the virtual mass method that accounts for the interaction of the vehicle structure and the enclosed liquid oxygen to LOX-filled tanks. The virtual mass method is applied in a modal analysis considering the hydroelastic effect of the launch vehicle tank. This method involves an analysis of the fluid in the tank in the form of mass matrix. To verify the accuracy of this method, the experimental modal data of a small hemispherical tank is used. Finally, the virtual mass method is applied to a 1/8-scale space shuttle external tank. In addition, the LOX tank bottom pressure in the external tank model is estimated. The LOX tank bottom pressure is the factor required for the coupling of the LOX tank with the propulsion system. The small hemispherical tank analysis provides relatively accurate results, and the 1/8-scale space shuttle external tank provides reasonable results. The LOX tank bottom pressure is also similar to that in the numerical results of a previous analysis.

Development of Optimal Septic Tank in the Countries of Water Shortages (물 부족국가에서 활용가능한 정화조의 최적모형 개발)

  • Lim, Bong-Su;Jing, Hai-Long
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.4
    • /
    • pp.418-427
    • /
    • 2015
  • This study was carried out to evaluate the performance of a lab-scale novel septic tank system for improving the conventional septic tank in the developing countries of water shortages. The lab-scale novel septic tank system consists of sepetic tank, aeration tank with HBC-ring, and sand filter. Optimum HRT was reguired about 1.5days to get a total COD removal efficiency of 90%, COD, BOD and SS removal efficiency was about 70%, 60%, and 85% in sepetic tank only. The structure of sepetic tank with two stages results in the high removal efficiency of organic matter. When sepetic tank, aeration tank, and sand filter were more than HRT 1.5days, 18hrs, and 12hrs, respectively, final effluent was less than 20 mg/L of BOD, 14 mg/L of SS, so that there is a high potential of its use for reusing water in flush toilet. There is no significant effect of HRT change on nutrient removal. Total nitrogen removal efficiency was about 40%, final effluent was 30~40 mg/L of TN, total phosphorus removal efficiency was about 11~25%, final effluent was 9~12 mg/L of TP. Because there is very small amounts of organic nitrogen and phosphorus in effluent, it was possible to reuse water for agricultural use.

Experimental investigation on small scale siphon breaker (소규모 사이펀 차단기에 대한 실험적 연구)

  • Ji, Dae-Yun;Kim, Sung hoon;Lee, Kwon-Yeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.1-8
    • /
    • 2018
  • In this study, a small-scale siphon breaker experimental facility was designed to examine the validity of the Siphon Breaker Simulation Program (SBSP). To design the experimental facility, the simulation results of the C factor, Chisholm B coefficient, and Undershooting Height (UH) were obtained by SBSP. The major parts of the experimental facility were the upper tank, lower tank, downcomer, and Siphon Breaker Line (SBL). The area of the Upper tank was $0.09-m^2$ with a height of 0.65-m. The height of the downcomer was 1.6-m. Pressure transmitters and an electronic scale were used to obtain the experimental results. The experimental variables were the sizes of Loss of Coolant Accident (LOCA) and SBL. The experimental results were analyzed by UH. The SBSP well predicted the UH with an error of 2.5%. Overall, it is possible to design siphon breakers with various scales using SBSP.

Scale Model Testing of a two-boat midwater trawl net (2척식 중층트롤 모형실험)

  • Jang, Ji-Won;Kim, Chun-Duk;Kim, Tae-An
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.5 no.1
    • /
    • pp.14-20
    • /
    • 1969
  • A scale model net test of the operation of a small two-boat midwater trawl net was performed in the circulating water tank at Pusan Fisheries College. The 1/32 scale model net was constructed after the modelling law of M. Tauti. This type of net is used in Europe for catching sprat like Hering. The net used was 1/32 the actual size. This scale was chosen with consideration for the water tank size. In this experiment, the transfomation of the net shape was observed especially inregard to variations in the height and breadth of the net mouth. These dimensions were varied by changing the breadth of the towing line and the connenting spread.

  • PDF

Wind pressure and buckling of grouped steel tanks

  • Portela, Genock;Godoy, Luis A.
    • Wind and Structures
    • /
    • v.10 no.1
    • /
    • pp.23-44
    • /
    • 2007
  • Wind tunnel experiments on small scale groups of tanks are reported in the paper, with the aim of evaluating the pressure patterns due to group effects. A real tank configuration is studied in detail because one tank buckled during a hurricane category 3. Three configurations are studied in a wind tunnel, two with several tanks and different wind directions, and a third one with just one blocking tank. The pressures were measured in the cylindrical part and in the roof of the tank, in order to obtain pressure coefficients. Next, computational buckling analyses were carried out for the three configurations to evaluate the buckling pressure of the target structure. Finally, imperfection-sensitivity was investigated for one of the configurations, and moderate sensitivity was found, with reductions in the maximum load of the order of 25%. The results help to explain the buckling of the tank for the levels of wind experienced during the hurricane.

A Study on the Characteristics of Small-scale Sewage Treatment Plants in Mountain Area and Operation Plan for Winter Season (산악지역 소규모하수처리시설의 특성 및 동절기 운영방안에 관한 연구)

  • Chae, Heejun;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.23 no.2
    • /
    • pp.183-188
    • /
    • 2021
  • In the case of small-scale sewage treatment plants, it is reported that the amount of inflow fluctuates and it is difficult to operate the sewage treatment due to the inflow of unknown water due to the aging of sewage pipes. In particular, there are many overall operational problems due to the decrease in water temperature in winter. In this study, the operation status of small-scale sewage treatment facilities located in mountainous areas and water quality changes according to temperature were analyzed. It was found that the concentration of BOD, COD, and SS in effluent water was greatly changed depending on the temperature, and it was found that COD was particularly affected. Accordingly, the water level of the bioreactor was raised by 0.4m in order to temporarily apply measures to lower the water temperature in winter. As a result of comparing and analyzing the results when the bioreactor was covered and operated, a significant improvement effect occurred. In addition, a plan to improve the treatment efficiency of the bioreactor in winter is to extend the residence time of the bioreactor, a plan to expand the bioreactor specification, a new flow control tank and transport it to the outside, and an oxygen-free air diffuser to be used as an aerobic tank in case of an emergency in winter. The improvement plan was suggested. The results of this study are expected to be used as basic data for the operation plan of small-scale sewage treatment facilities in winter.

Development of a special thermal-hydraulic component model for the core makeup tank

  • Kim, Min Gi;Wisudhaputra, Adnan;Lee, Jong-Hyuk;Kim, Kyungdoo;Park, Hyun-Sik;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1890-1901
    • /
    • 2022
  • We have assessed the applicability of the thermal-hydraulic system analysis code, SPACE, to a small modular reactor called SMART. For the assessment, the experimental data from a scale-down integral-test facility, SMART-ITL, were used. It was conformed that the SPACE code unrealistically calculates the safety injection flow rate through the CMT and SIT during a small-break loss-of-coolant experiment. This unrealistic behavior was due to the overprediction of interfacial heat transfer at the steam-water interface in a vertically stratified flow in the tanks. In this study, a special thermal-hydraulic component model has been developed to realistically calculate the interfacial heat transfer when a strong non-equilibrium two-phase flow is formed in the CMT or SIT. Additionally, we developed a special heat structure model, which analytically calculates the heat transfer from the hot steam to the cold tank wall. The combination of two models for the tank are called the special component model. We assessed it using the SMART-ITL passive safety injection system (PSIS) test data. The results showed that the special component model well predicts the transient behaviors of the CMT and SIT.

A Study on Safety Distance for Small Scale LNG Storage facility (소규모 LNG 저장시설의 안전거리 기준 연구)

  • Oh, Shin-Kyu;Jo, Young-Do
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.185-191
    • /
    • 2014
  • In this study safety distance was investigated for small-scale LNG storage facilities in order to provide basic data for safety. The results are as follows; (1) For explosion pressure criteria, current criteria are reasonable, but water spray system should be recommended to LNG storage tank to ensure safety. (2) For criteria based on the results of the quantitative risk assessment, criteria applied to people are $5kW/m^2$ for radiation, LFL for dispersion, and 7kPa for explosion pressure. And criteria applied to facility are $37.5kW/m^2$ for radiation and 20 kPa for explosion pressure.

Development of Guidelines for Physical Security Systems of Small-scale Water Supplies (소규모수도시설의 보안시설 설치지침 개발)

  • Kim, Youngil;Yi, Sangjin;Lee, Doojin;Lee, Wontae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.723-730
    • /
    • 2013
  • Due to the event of hazardous chemical injection into a water storage tank in Hongseong, Chungcheongnam-do in 2012, the Korean Ministry of Environment has revised the enforcement rules of the Water Supply and Waterworks Installation Act to install surveillance equipments such as closed-circuit television(CCTV). However, the enforcement rules still do not provide concrete provision for installation of physical security equipments. Thus we studied vulnerability of small-scale water supplies in Korea and developed guidelines for the physical security system of the facilities. The guidelines include selection and recommendation of the physical security approaches and measures to detect, delay and response to the presence of an intruder in small-scale water supplies. The security features include protection utilities(e.g., fencing and fence topping), exterior intrusion detectors and alarms, locks and padlocks, surveillance utilities(e.g., CCTV), and others.