• Title/Summary/Keyword: Small reverberation chamber

Search Result 8, Processing Time 0.039 seconds

A Study to Estimate Transmission Loss of HST using a Small Scale Reverberation Chamber (소형잔향실을 이용한 고속철도 차량 구조재의 투과손실 연구)

  • Kim, Tae-Min;Kim, Jeung-Tae
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.1
    • /
    • pp.19-23
    • /
    • 2011
  • The method to reduce interior noise of train was being studied. To improve transmission loss of train is one of the best way to reduce interior noise. But, the estimate to transmission loss requires lots of the commercial costs. In this study, the method to estimate transmission loss of high speed train is proposed using a scale reverberation chamber. The result shows that a transmission loss estimated using small scale reverberation is similar to that using huge reverberation chamber. The transmission loss estimated based on small scale reverberation chamber can be optimal with respect to the commercial coasts.

Study of Sound Transmission Characteristics of using a Scale Reverberation Chamber and vibro acoustic FEM (투과손실 예측을 위한 유한요소 해석과 소형 잔향실 실험의 비교에 검증에 관한 연구)

  • Lee, Jun-Heon;Kim, Bum-Soo;Kim, Kwan-Ju
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.92-95
    • /
    • 2011
  • The walls of modern train cars are required to have higher transmission loss since modern train have had high speed and light weight. The method based on Reverberation Chamber like KS F 2808 could be used to measure transmission loss. However, this method has difficulty in that constrained Standard of it requires extremely large facilities. Recently, the method based on Scale Reverberation Chamber is used as an alternative to Reverberation Chamber. The method of Scale Reverberation Chamber is known to be small and economical but it provides standing wave that directly influences measurement error. Therefore, this research is focus on predicting standing waves based on method of FFM and reducing measurement error by changing shape of chamber.

  • PDF

Comparison Study of Sound Transmission Loss in High Speed Train

  • Kim, Tae-Min;Kim, Jeung-Tae
    • International Journal of Railway
    • /
    • v.4 no.1
    • /
    • pp.19-27
    • /
    • 2011
  • Many studies for improving the railway vehicle's performance and comfort such as speed, weight and noise are currently in progress. Improving the structural characteristics of the vehicle for greater noise insulation is considered important for reducing disturbance due to noise, but measuring transmission loss entails large costs. This study explores an alternative method for estimating and measuring the railway vehicle's transmission loss that involves on applying the numerical analysis coupled with scaled reverberation chamber measurement. The transmission loss measurement using scaled reverberation chamber was performed after the compensation value was found through 1mm thickness(1t) specimen. For numerical analysis, a commercially available acoustics solver VA ONE was used. The proposed method is found to lead to transmission loss measurement comparable to the measurements based on large-scale reverberation chamber. Thus, it can be argued that a reliable method has been developed for measuring railway vehicle's transmission loss.

Transmission Loss Estimation of HST using a Small Scale Reverberation Chamber (소형 잔향실을 이용한 동력 분산형 고속철도 차량의 투과손실 측정)

  • Kim, Tae-Min;Son, Chang-Hoon;Kim, Jeung-Tae;Kim, Jung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.302-307
    • /
    • 2010
  • Development of light-weight high speed train (HST) based on distributed motor control with the top speed of 350 km/hr has engendered a need for abatement of the interior noise of the train cabin. The development of noise abatement measures is crucial at the design stage of the train car since the noise transmission characteristics of the car structure directly influences the cabin interior noise. Since the transmission loss measurement using the entire car structure is often not feasible, especially at the initial stages of the train development, investigation of transmission characteristics using small-scale reverberation chamber can furnish useful alternative source of predicting the noise level. In the present study, white noise is generated at source and transmission loss estimated by performing measurement of a specimen in a scaled reverberation chamber. Comparison of measured values with the previously derived numerical values show good agreement in the overall trend but appreciable quantitative differences still remain.

  • PDF

The Study on Correction Factor of a Small Scale Reverberation Chamber to Estimate Transmission Loss (소형 잔향실의 확산 음장 보정 계수 측정 연구)

  • Kim, Tae Min;Kim, Da Rae;Kim, Jeung Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.960-965
    • /
    • 2014
  • Transmission loss of specimen is calculated by measuring energy of incident and transmission and using reverberant room of large size. But normal measurement of transmission loss has trouble because it is actually demanded that large area and specimen of certain size is satisfied with condition of diffused sound field. Especially, in case of mechanical component, interested frequency band is mid-frequency band between 500 ~ 2k Hz, and it is used to be available to minimize a reverberation chamber under conditions satisfying acoustic one because production of specimen for transmission loss measurement has limit. But, as in semi-reverberation room, it is difficult to satisfy condition of diffuse sound field and modification factor is applied to complement that. Correction factor when measuring transmission loss using semi-reverberation chamber is required accuracy because it works as main factor determining reliability of reuslts on transmission loss. In this study, it is analyzed that an effect on correction factor based on varying materials and sizes of specimens in order to deduction of it. Also It is confirmed that applied by elicited correction factor with actual railway vehicle's floor has reliability.

  • PDF

Improvements of Reverberation Chamber's Performance by using Active Noise Control (능동 소음제어를 이용한 잔향실의 저주파 특성 개선 가능성)

  • K. Kim, Young-Key;Oh, Shi-Whan;Moon, Sang-Mu;Im, Jong-Min;Kim, Hong-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.857-861
    • /
    • 2004
  • An active method that improves low frequency characteristics of a reverberation chamber has been proposed. Spatial uniformity of sound pressure at low frequency has been increased by applying active noise control system. The system acts as frequency selective damping materials, which decreases resonance at low frequency and leave high frequency sound field as it is. Linearity of the chamber, which is essential for sound power measurement in the chamber, is guaranteed since fixed control logic has been adopted. Simple application and tests have been done in a small sized rectangular reverberation chamber which has 400Hz cutoff, Loud speakers were used to simulate a noise source and to construct an active noise control system. The spatial distribution of a sound field at 250Hz, 315Hz and 400Hz bands has been measured before and after control. The standard deviation of sound field has been decreased from 3.4dB to 2.5dB. The results show the possibility of active control system as a sound diffuser.

  • PDF

Calculation of Coupling Loss Factor for Small reverberation cabin using Statistical Energy Analysis (통계적 에너지 해석법을 이용한 소형 잔향실의 연성손실계수 측정)

  • 김관주;김운경;윤태중;김정태
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.797-801
    • /
    • 2003
  • The Statistical Energy Analysis is based on the power flow and the energy conservation between sub-systems, which enable the prediction of acoustic and structural vibration behavior in mid-high frequency ranges. This paper discusses the identification of SEA coupling loss factor parameters from experimental measurements of small reverberation chamber sound pressure levels and structural accelerations. As structural subsystems, steel plates with and without damping treatment are considered. Calculated CLFs were verified by both transmission loss values for air-borne CLF case and running SEA commercial software As a result, CLFs have shown a good agreement with those computed by software. Acoustical behavior of air-borne noise and structure-borne noise has been examined. which shows reasonable results, too.

  • PDF

Floor Impact Sound Pressure Level Characteristics by the Change of Reverberation Time in Mock-up Test Rooms (수음실 잔향시간 변화에 따른 중량 충격음 레벨 특성 - 실험실 환경을 중심으로 -)

  • Jeong, Jeong Ho;Lee, Byung Kwon;Yeon, Jun Oh;Jeon, Jin Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.4
    • /
    • pp.339-347
    • /
    • 2014
  • Floor impact sound in high-rise apartment building became one of social problems. A lot of civil complaints on floor impact sound occur continuously and the number of disputes between neighbors in small and aged apartment buildings is increasing. Interests on heavy-weight impact sound pressure level measurement and evaluation method is increased. Previous study reported that heavy-weight impact sound level was changed by the sound field condition of receiving reverberation chamber. In this study, heavy-weight impact sound pressure level change by the receiving sound field condition was measured in standard test facility and mock-up test room. These two experimental conditions were designed to simulate averaged living room of common apartment units. By the change of sound absorption power in receiving room, heavy-weight impact sound pressure level in most of frequency bands were changed in standard test facility and mock-up room. Normalized maximum sound pressure level regulated in ISO 16032 showed wider range of heavy/soft impact sound pressure level. Heavy/soft impact sound pressure level change was became smaller by the application of standardized maximum sound pressure level and ISO/CD 10140-3 Amd 2 method. In the case of standardized maximum sound pressure level, absolute sound pressure level changed. From these results, receiving sound field correction method regulated in ISO/CD 10140-3 Amd 2 is needed for the precision measurement and evaluation of heavy-weight impact sound.