• Title/Summary/Keyword: Small chamber

Search Result 623, Processing Time 0.032 seconds

Retention of Endothelial Cells adhered on Polyurethane Surface under Flow Condition

  • Chang, Jun-Keun;Chang, Hyun-A;Kim, Jin-Hee;Kim, Jong-Won;Han, Dong-Chul;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.3
    • /
    • pp.355-364
    • /
    • 1996
  • Construction of the stable monolayer of endothelial cells onto physicochemically modified polymeric surFace is one of the appropriate method to develop the small caliber vascular graft with the long-term patency. In this study, we constructed the monolayer of endothelial cells on the fibronectin rind the extracellular matrix-coated polyurethane surface derived from human fibroblast cells. To elucidate the adhesion strength of endothelial cells on the extracellular matrix-coated polyurethane, a laminar flow chamber apparatus was developed to exposure the shear stress on the apical membrane of ondothelial cells. Endothelial cells show the strongest adhesion after two days of seeding onto the fibronectin-coated polyurethane surface, whereas endothelial cells on the extracellular matrix derived from the human flbroblast cells show the minimal doubling time of cellular growth.

  • PDF

Performance Improvement of an Integrated-type Fully-Hydraulic Breaker by Sensitivity Analysis (일체형 순수유압식 브레이커의 민감도해석에 의한 성능 향상)

  • Choi, S.;Chang, H.W.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.1
    • /
    • pp.17-24
    • /
    • 2009
  • The performance improvement of a small-size integrated-type fully hydraulic breaker is studied in this paper. Mathematical modeling of the breaker is established and verified by experiment. Through sensitivity analysis using AMESim, the key design parameters are selected and nearly optimized to maximize the impact energy as well as to improve the dynamic characteristics such as the piston upper chamber pressure, piston and valve displacements. As a result, the impact energy, blows per minute(bpm) and output power are increased by 52.9%, 1%, and 55.6%, respectively compared with the current design. The dynamic characteristics of the piston upper chamber pressure, piston and valve displacements are also improved by the design change.

  • PDF

The Interaction of Vortex Shedding Behavior in Hybrid Rocket Combustion (와류간섭에 의한 하이브리드로켓 연소 특성)

  • Park, Kyung-Soo;Lee, Chang-Jin;Shin, Kyung-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.244-248
    • /
    • 2012
  • A series of hybrid rocket combustion experiments were carried out with PMMA/GOx changing diameter and length of the disk installed at pre-chamber. The disk can generate vortex shedding flow and change flow conditions prior to entering the fuel grain which could also alter the combustion characteristics and pressure oscillations. The interaction of vortex shedding in the pre-chamber and small-scale vortices adjacent to burning surfaces by using combustion test.

  • PDF

Gas Flow Rate Dependency of Etching Result: Use of VI Probe for Process Monitoring (가스 유량 변화에 따른 식각 공정 결과: VI Probe 활용 가능성 제안)

  • Song, Wan Soo;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.27-31
    • /
    • 2021
  • VI probe, which is one of various in-situ plasma monitoring sensor, is frequently used for in-situ process monitoring in mass production environment. In this paper, we correlated the plasma etch results with VI probe data with the small amount of gas flow rate changes to propose usefulness of the VI probe in real-time process monitoring. Several different sized contact holes were employed for the etch experiment, and the etched profiles were measured by scanning electron microscope (SEM). Although the shape of etched hole did not show satisfactory relationship with VI probe data, the chamber status changed along the incremental/decremental modification of the amount of gas flow was successfully observed in terms of impedance monitoring.

Small Scaled Laboratory Test of Eco-Friendly Backfill Materials with Bottom Ash (바톰애쉬를 이용한 환경친화적 뒤채움재의 실내모형실험)

  • Lee, Kwan-Ho;Lee, Kyung-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1889-1894
    • /
    • 2012
  • A small-scale chamber test laboratory for controlled low strength materials with bottom ash and recycled in-situ soil have been carried out. Laboratory test which was simulated during construction stage was conducted. The vertical deflection of 4.43mm to 6.6mm, and the horizontal deflection of 5.49mm to 15.9 mm were measured during backfilling. In case of loading, the vertical deflection of 2.41mm to 8.69mm, and the horizontal deflection of 1.66mm to 2.53mm were measured. Its residual deflections were 1.40mm to 5.93mm for vertical and 1.66mm to 2.53mm for lateral. The vertical and horizontal deflecto of controlled low strength materials were smaller than that of sand backfill. Also, it was same trend for the measured surface settlement.

Analysis of cementation effects on Small-strain Shear Modulus of Sand (모래의 미소변형 전단탄성계수에 대한 고결영향 분석)

  • Lee, Moon-Joo;Choo, Hyun-Wook;Lee, Jong-Sub;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1431-1437
    • /
    • 2008
  • The small-strain shear modulus ($G_{max}$) of uncemented sand is affected by the the mean principal stress and void ratio, and it has been known that the cementation and aging also affect to $G_{max}$ of sand. For extensive understanding about the effect of cementation on the $G_{max}$ of sand, a series of bender element tests was conducted on the cemented specimens prepared in a large calibration chamber by pluviation of the sand-gypsum mixture. It was observed from the experimental results that the $G_{max}$ of cemented sand is higher above 10 times than value of uncemented one, and it increases exponentially with the gypsum content increases. Whereas, the increase of the vertical stress from 50kPa to 200kPa and the relative density from 40% to 80% result in 20~30% and 2 times increase of $G_{max}$, respectively. It means that the gypsum content, that is cementation level, is the most influential factor on the $G_{max}$ of cemented sand. In addition, the effect of relative density on $G_{max}$ was more apparent on cemented sand than uncemented one.

  • PDF

Evaluation of the combustion chamber for burning candle and measuring the emission factor of its’ combustion products (양초 연소 시 발생되는 오염물질 방출계수 측정을 위한 연소실 제작과 평가)

  • Lim, Hyung-Jin;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.236-245
    • /
    • 2015
  • Recently, candles have been widely used to create a romantic atmosphere and to heat tea. In this study, a small combustion chamber for candle was designed using an 0.008 m3 bell jar. The emission factors of combustion products were then measured. The combustion chamber includes a glass dish, which prevents candle flame from affecting the composition of the gas emitted through the exhaust outlet. The outlet in the combustion chamber was designed as a cone shape, and it was lengthened to prevent flow from the outside, which could affect the homogeneous composition of the exhaust gas. The temperature at the outlet of the chamber was 34 ℃~41℃. The major combustion products of the candle, such as such aldehydes and acids, contained oxygen. The mass specific emission rates of benzene, toluene, ethylbenzene, and TVOC were 0.04 μg/g, 0.01 μg/g, 0.02 μg/g, and 3.81, respectively. The mass specific emission rates of formaldehyde, acetaldehyde and benzaldehyde were 4.48 μg/g, 1.09 μg/g, and 0.67 μg/g, respectively. Considering the different compositions of the candle samples, their mass specific emission rates were similar to those obtained by using a large chamber 0.17 m3~50 m3 in size.

Real-Time Small Exposed Area $SiO_2$ Films Thickness Monitoring in Plasma Etching Using Plasma Impedance Monitoring with Modified Principal Component Analysis

  • Jang, Hae-Gyu;Nam, Jae-Uk;Chae, Hui-Yeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.320-320
    • /
    • 2013
  • Film thickness monitoring with plasma impedance monitoring (PIM) is demonstrated for small area $SiO_2$ RF plasma etching processes in this work. The chamber conditions were monitored by the impedance signal variation from the I-V monitoring system. Moreover, modified principal component analysis (mPCA) was applied to estimate the $SiO_2$ film thickness. For verification, the PIM was compared with optical emission spectroscopy (OES) signals which are widely used in the semiconductor industry. The results indicated that film thickness can be estimated by 1st principal component (PC) and 2nd PC. Film thickness monitoring of small area $SiO_2$ etching was successfully demonstrated with RF plasma harmonic impedance monitoring and mPCA. We believe that this technique can be potentially applied to plasma etching processes as a sensitive process monitoring tool.

  • PDF

Design of Small CRPA Arrays with Circular Microstrip Loops for Electromagnetically Coupled Feed

  • Hur, Jun;Byun, Gangil;Choo, Hosung
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.2
    • /
    • pp.129-135
    • /
    • 2018
  • This paper proposes a design of small controlled reception pattern antenna (CRPA) arrays using circular microstrip loops with frequency-insensitive characteristics. The proposed array consists of seven identical upper and lower circular loops that are electromagnetically coupled, which results in a frequency-insensitive behavior. To demonstrate the feasibility of the proposed feeding mechanism, the proposed array is fabricated, and its antenna characteristics are measured in a full-anechoic chamber. The operating principle of the proposed feeding mechanism is then interpreted using an equivalent circuit model, and the effectiveness of the circular loop shape is demonstrated by calculating near electromagnetic fields in proximity to the radiator. The results confirm that the proposed feeding mechanism is suitable to have frequency-insensitive behavior and induces strong electric and magnetic field strengths for higher radiation gain in extremely small antenna arrays.

Load Transfer Characteristics of Pile Foundation for Lightweight Pavement in Sand Soil using Laboratory Chamber Test (모형챔버시험을 이용한 사질토 지반의 경량포장체용 기초의 하중전달 특성)

  • Shin, Kwang-Ho;Hwang, Cheol-Bi;Jeon, Sang-Ryeol;Lee, Kwan-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4588-4594
    • /
    • 2014
  • In this study, small scaled (1/30) laboratory chamber tests of the pile foundation for a lightweight concrete pavement system were carried out to evaluate the safety of a pile foundation on sandy soil. The testing ground was simulated in the field and a standard pile-loading test was conducted. The test piles were divided into 3 types, Cases A, B and C, which is the location from the center of the slab by applying a vertical load. The interval between the piles was set to 8 cm. As a result of the pile foundation model test, the pavement settled when the vertical load was increased to 12kg from 1.5kg in sandy soil ground, particularly the maximum settlement of 0.04mm. Judging from the model chamber test, Case A showed compressive deformation, whereas Case B represented the compression and tensile forces with increasing vertical load. Case C showed an increase in tensile strain.