• Title/Summary/Keyword: Small Mass Measurement System

Search Result 35, Processing Time 0.022 seconds

Influence of Refrigeration Oil on Evaporation Heat Transfer Characteristics of R-290 Inside Micro Fin Tube (마이크로 휜 증발관내 냉매 R-290의 열전달 특성에 미치는 냉동유의 영향)

  • Park, Cheol-Min;An, Young-Tae;Lee, Wook-Hyun;Kim, Jeung-Hoon;Kim, Jong-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.7
    • /
    • pp.938-944
    • /
    • 2000
  • Recently, micro fin tube is widely used to heat exchanger for high performance. And, as the alternative refrigerants for R-22, hydrocarbons such as R-290, R-600 and R-600a are very promising because of their low GWP and ODP. Thus, R-290 was used as working fluid in this study. Most design of heat exchanger had been based on heat transfer characteristics of pure refrigerant although refrigerant oil exists in the refrigeration cycles. So, the influence of oil on heat transfer characteristics have to be considered for investigating exact evaporation heat transfer characteristics. But, this is an unresolved problem of refrigeration heat transfer. Therefore the influence of the refrigeration oil to the evaporation heat transfer characteristics of R-290 were conducted in a horizontal micro tin tube. The mineral oil was used as refrigeration oil. The experimental apparatus consisted of a basic refrigeration cycle and a system for oil concentration measurement. Test conditions are as the follows; evaporation temperature $5^{\circ}C$, mass velocity 100 $kg/m^2s$, heat flux 10 $kW/m^2$, oil concentration 0, 1.3, 3.3, 5.7 wt.%, and quality $0.07{\sim}1.0$. When refrigeration oil was entered, oil foaming was observed at the low quality region. And, very small bubbles were observed as quality was increased. Pressure drop and heat transfer coefficient increased as the concentration of refrigeration oil increased to 5 wt.%.. The performance index of heat exchanger was the highest near 3.3 wt.%.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

Acoustic Channel Formation and Sound Speed Variation by Low-salinity Water in the Western Sea of Jeju during Summer (여름철 제주 서부해역의 저염분수로 인한 음속변화와 음파채널 형성)

  • Kim, Juho;Bok, Tae-Hoon;Paeng, Dong-Guk;Pang, Ig-Chan;Lee, Chongkil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.1-13
    • /
    • 2013
  • Salinity does not generally affect sound speed because it shows very small variations in the ocean. However, low salinity water appears in the Western Sea of Jeju Island every summer so that sound speed and sound propagation can change near sea surface. We calculated Sound Speed Profile (SSP) using vertical profiles of temperature and salinity, which were averaged over years of normal salinity and low salinity (<28 psu) from 30 years (1980~2009) at 3 sites of Korea Oceanographic Data Center (KODC). As a result, sound speed variation by low salinity alone was -5.36 m/s at sea surface and -1.35 m/s at 10m depth for low salinity environments. Gradient of SSP was positive down to 5 m depth due to decrease of sound speed near surface, leading formation of haline channel. Simulation of acoustic propagation using a ray model (Bellhop) confirmed the haline channel. Haline channel has formed 4 times while hydrostatic channel controlled by only pressure has formed 9 times for 30 years. The haline channel showed larger critical angles of rays than hydrostatic channel. Haline channel was also formed at some sites among 20 measurement sites in low salinity water mass which appeared on August $1^{st}$ 2010.

Development of Auto-spray system to improve the quality of 3D Scanning Quality (3D 스캔 시 품질향상을 위한 스프레이 도포 자동화 장비 개발)

  • Kim, Wonseop;Jo, Jae Heung;Kim, Dongsu;Kim, Donggyoo;Hong, Seokmoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.100-105
    • /
    • 2016
  • The use of 3D scanners has increased gradually according to increasing 3D printer applications. The precision inspection of car parts or electronic components is an important issue not only in the field of mass production, but also in small-scale production. Recently, 3D scanner equipment efficiency and recognition technology has been improved continuously. On the other hand, the spraying time to prepare 3D scanning is time-consuming and has environmental problems. Therefore, an automatic spray system has been in demand by the manufacturing industry. Automatic spray equipment was newly developed for the preparation of a 3D scanner. In this research, the automatic spray system guarantees uniform spray operation. To determine the optimal spray parameters, various spraying methods, solutions and conditions were tested and compared with the experiments. The preparation time for 3D scanning was reduced to 1/10 compared to the manual spraying time, and indicates the optimal spraying conditions through a comparison of various spray coating conditions.

Comparative study between proportional method and directional method in locating acupoints at forearm (전완부(前腕部) 경혈(經穴) 취혈(取穴)에서 골도분촌법(骨度分寸法)과 일부법(一夫法)의 비교(比較) 연구(硏究))

  • Park, Hi-Joon;Chae, Youn-Byoung;Cha, Wung-Seok;Park, Jong-Bae;Lee, Hye-Jung;Lee, Hyang-Sook;Yin, Chang-Sik;Koh, Hyung-Kyun;Kim, Su-Young;Choe, Il-Hwan;Kim, Kang-Sik;Moon, Jung-Bae;Bae, Ki-Tae;Rheu, Kyoung-Hwan;Yook, Keun-Yung;Jeong, Byeong-Ju;Sohn, In-Chul;Lim, Sabina
    • Korean Journal of Acupuncture
    • /
    • v.21 no.4
    • /
    • pp.31-41
    • /
    • 2004
  • Background : The cun measurement system, an essential and convenient method in locating acupoints, has been widely used in the practice of acupuncture. However, traditional cun measurement has been criticized for its lack of reliability. Objectives : The purposes of this study are to determine if one cun measured by the directional methods have a consistency with that of proportional methods and to investigate which factors are related with these differences, especially in forearm. Methods : The distance between the elbow crease and the wrist crease of forearm was compared to a reference value of one cun obtained by the directional method. In this method, one cun is one third of the distance between index finger and small finger of a subject, measured at proximal interphalangeal joint. In addition, to investigate the factors influencing the differences between these two methods, we measured the height and body weight and calculated body mass index (BMI). Finally we analyzed the factors correlated with these lengths by linear regression test. Results : The results showed that one cun obtained by the directional methods were significantly different from one cun by the proportional methods in forearm. It was demonstrated that the length acquired with the directional method was more correlated with body weight and body mass index, while the length obtained by the proportional method was more correlated with the height. Conclusion : These findings suggest that the directional method is less likely dependable in locating acupoints than the proportional method because the influencing factors are different.

  • PDF