• 제목/요약/키워드: Small Flows

검색결과 493건 처리시간 0.04초

남강댐 유역의 네 가지 하천유량자료 확장방법 비교 및 평가 (Evaluation and Comparison of Four Streamflow Record Extension Techniques for Namgang Dam Basin)

  • 김경훈;정강영;윤종수;천세억
    • 한국물환경학회지
    • /
    • 제30권1호
    • /
    • pp.60-67
    • /
    • 2014
  • In this study, four methods for calculation of continuous daily flow was suggested using short-term or partial recording station of streamflow including missing data. Using these methods, standard flows at the outlet of unit/small basins for the management of total maximum daily loads (TMDLs) in Namgang dam basin were estimated from full-period flow duration curve (FDC). Four methods of extension are described, and their properties are explored. The methods are regression (REG), regression plus noise (RPN), and maintenance of variance extension types 1 and 2 (MOVE.1, MOVE.2). In these methods, the continuous daily flow was calculated using extension equation based on correlation analysis, after conducting the correlation analysis between historic record of streamflow and long-term recording station (a base station). Finally the best optimal method was selected as the MOVE.2, and the standard flows in the abundant, ordinary, low and drought flow estimated from FDC was evaluated using MOVE.2 in unit/small basins.

지형학적순간단위도를 이용한 미계측 소유역의 한계유출량 산정 검증 (Verification about Threshold Discharge Computation using GIUH on ungauged small basin)

  • 최현;이상진
    • Spatial Information Research
    • /
    • 제14권1호
    • /
    • pp.15-27
    • /
    • 2006
  • 본 연구는 지형학적 단위도(geomorphoclimatic unit hydrograph, GIUH)로 미계측 소유역의 한계유출량을 산정에 관한 연구이다. GIUH는 수문특성예측에 많이 이용된다. 연구대상지역인 경북 감포지역에 대한 $5km^2$의 소유역으로 수문특성인자, 제방월류유량 및 합성단위도(Clark Nakayasu, S.C.S)에 의한 유출량도 함께 분석하였다. 그리고 지리정보시스템으로 지형인자를 추출하고 지형학적순간단위도에서 산정된 첨두유량을 감포지점의 실측자료와 비교함으로써 지형학적순간단위도의 타당성을 검증하였고, 이와 NRCS(Natural Resources Conservation Service)방법을 이용하여 돌발홍수 기준우량을 제시하기위한 한계유출량을 산정하였다.

  • PDF

Angiotensin Ⅱ의 이뇨작용(利尿作用) (Diuretic Action of Angiotensin II in Dog)

  • 고석태;이민재;허영근
    • 약학회지
    • /
    • 제33권3호
    • /
    • pp.183-190
    • /
    • 1989
  • Angiotensin II, adminstered (infused or injected) intravenously, elicited the antidiuretic action with the decreased parameters of renal function at a small dose ($0.01\;{\mu}g/kg/min$), whereas, at a large dose (0.03, $0.1\;{\mu}g/kg/min$ and $5.0\;{\mu}g/kg$), it produced the diuretic action accompanied the increased amounts of sodium and potassium excreted in urine ($E_{Na}\;and\;R_K$). At this time, glomerular filtration rates (GFR) were weakened slightly and renal plasma flows (RPF) were reduced markedly, and then filtration fractions (FF) were increased. Angiotensin II, infused into a renal artery, exhibited antidiuretic action at a small dose ($0.003\;{\mu}g/kg/min$), and diuretic action at a large dose ($0.01\;{\mu}g/kg/min$), only in infused (experimental) kidney. The mechanism of the action was similar to the cases of the intravenous angiotensin II. The above results suggest that angiotensin II of a large dose produced diuretic action due to mechanism inhibiting reabsorption of electrolytes in renal tubules, mainly in proximal tubule in dog.

  • PDF

상수도 관망 유량관측 자료의 주성분 분석을 위한 분석기간의 설정 (Identifying an Appropriate Analysis Duration for the Principal Component Analysis of Water Pipe Flow Data)

  • 박수완;전대훈;정소연;김주환;이두진
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.351-361
    • /
    • 2013
  • In this study the Principal Component Analysis (PCA) was applied to flow data in a water distribution pipe system to analyze the relevance between the flow observation dates, which have the outliers of observed night flows, and the maintenance records. The data was obtained from four small size water distribution blocks to which 13 maintenance records such as pipe leak and water meter leak belong. The flow data during four months were used for the analysis. The analysis was carried out to identify an appropriate analysis period for a PCA model for a water distribution block. To facilitate the analyses a computational algorithm was developed. MATLAB was utilized to realize the algorithm as a computer program. As a result, an appropriate PCA period for each of the case study small size water distribution blocks was identified.

벽면에서의 입자 고찰에 의한 열전달 수치 모델 (Numerical Modeling of Heat Transfer Due to Particle Impact on a Wall)

  • 권오붕
    • 수산해양기술연구
    • /
    • 제31권3호
    • /
    • pp.296-305
    • /
    • 1995
  • 보일러 및 연소로 등에서의 부유체 환경에서 입자와 벽면 사이의 열전달 현상을 규명하기 위한 수치적인 모델링을 행하였다. 본 연구에서는 벽면에 수직 충돌하는 입자에 의한 열전달 현상을 알아보기 위해 2차원 모델을 사용하였다. 입자표면에서 단열된 경계조건과 등온의 경계조건을 사용한 결과를 비교함으로써, 입자가 벽면에 충돌할 때 유체를 매개로한 전도와 입자에 의해 야기된 대류 현상을 비교할 수 있었다. 계산 결과, 입자가 벽면에 충돌하기 직전에는 입자 크기의 반정도의 거리에 도달할 때까지는 입자의 영향이 별로 없고, 충돌하고 난 후에 영향이 많았다. 또한, Pe 수가 작을 때는 유체를 매개로 한 전도가 지배적이며, Pe 수가 증가할수록 야기된 대류의 효과가 점차 증가하였다

  • PDF

소형터보압축기 볼류트 내부의 3차원 점성 유동장 해석 (An Analysis on Three-dimensional Viscous Flow Fields in the Volute Casing of a Small-size Turbo-compressor)

  • 김동원;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.777-782
    • /
    • 2000
  • The flow fields in the volute casing of a small-size turbo-compressor at different flowrate (design point ${\pm}20%$) are studied by numerical analysis. The governing equations for three-dimensional steady viscous flow are solved using SIMPLE algorithm with commercial code of STAR-CD. Numerical results show that the three-dimensional flow pattern inside the volute casing of a small-size turbo-compressor is strongly influenced by secondary flows that are typically created by the curvature or the casing passages. The flow pattern in the casing also affects the performance of the turbo-compressor. In order to elucidate the loss mechanism through the volute, we prepared the secondary flow, velocity magnitude, and static pressure distribution at the four cross-sectional planes of the casing.

  • PDF

Motion-Based Background Subtraction without Geometric Computation in Dynamic Scenes

  • Kawamoto, Kazuhiko;Imiya, Atsushi;Hirota, Kaoru
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2003년도 ISIS 2003
    • /
    • pp.559-562
    • /
    • 2003
  • A motion-based background subtraction method without geometric computation is proposed, allowing that the camera is moving parallel to the ground plane with uniform velocity. The proposed method subtracts the background region from a given image by evaluating the difference between calculated and model Hows. This approach is insensitive to small errors of calculated optical flows. Furthermore, in order to tackle the significant errors, a strategy for incorporating a set of optical flows calculated over different frame intervals is presented. An experiment with two real image sequences, in which a static box or a moving toy car appears, to evaluate the performance in terms of accuracy under varying thresholds using a receiver operating characteristic (ROC) curve. The ROC curves show, in the best case, the figure-ground segmentation is done at 17.8 % in false positive fraction (FPF) and 71.3% in true positive fraction (TPF) for the static-object scene and also at 14.8% in FPF and 72.4% In TPF for the moving-object scene, regardless if the calculated optical flows contain significant errors of calculation.

  • PDF

차가운 물에 잠겨있는 수직운동 벽면주위의 자연대류에 관한 안정성 (Hydrodynamic Stability of Buoyancy-induced Flows Adjacent to a Vertical Isothermal Surface in Cold Pure Water)

  • 황영규
    • 대한기계학회논문집
    • /
    • 제15권2호
    • /
    • pp.630-643
    • /
    • 1991
  • The hydrodynamic stability equations are formulated for buoyancy-induced flows adjacent to a vertical, planar, isothermal surface in cold pure water. The resulting stability equations, when reduced to ordinary differential equation by a similarity transformation, constitute a two-point boundary-value(eigenvalue) problem, which was numerically solved for various values of the density extremum parameter R=( $T_{m}$ - $T_.inf./) / ( $T_{o}$ - $T_.inf./). These stability equations have been solved using a computer code designed to accurately solve two-point boundary-value problems. The present numerical study includes neutral stability results for the region of the flows corresponding to 0.0.leq. R. leq.0.15, where the outside buoyancy force reversals arise. The results show that a small amount of outside buoyancy force reversal causes the critical Grashof number $G^*/ to increase significantly. A further increase of the outside buoyancy force reversal causes the critical Grashof number to decrease. But the dimensionless frequency parameter $B^*/ at $G^*/ is systematically decreased. When the stability results of the present work are compared to the experimental data, the numerical results agree in a qualitative way with the experimental data.erimental data.

자영업부문(自營業部門)을 중심(中心)으로 한 노동력(勞動力)의 유동(流動) (Labor Market Dynamics in the Self-employed Sector in Korea)

  • 류재우;최호영
    • 노동경제논집
    • /
    • 제23권1호
    • /
    • pp.137-165
    • /
    • 2000
  • 본 연구는 자영업부문을 중심으로 한 노동력의 유동 패턴을 분석하였는데, 실업 및 비경제활동을 경유하는 노동력 유동이 중요한 비중을 차지하기는 하지만 그것은 일부의 한계적 노동자에게 집중된 현상인 것임을 보였다. 그러나 자영업주 중에서의 이들 한계적인 노동자의 비중은 적어도 외환위기 전까지는 지속적으로 축소됨으로 해서 자영업주의 평균적인 질과 취업 안정성은 높아져 온 것으로 나타난다. 한편 자영업에 종사한 경험이 있는 자의 비용, 자영업을 장기간 지속할 확률 등은 1990년을 기점으로 감소세에서 증가세로 반전된 것으로 나타난다. 이는 취업자 중의 자영업주 비중의 시계열적인 변화와 일치하는 것으로서 이들 자영업 경험률 및 지속기간의 변화가 자영업주 비중의 시계열상의 변화를 일정부분 설명할 수 있음을 보여준다.

  • PDF

초음속 유동장에서 기저 유동의 Detached Eddy Simulation (DETACHED EDDY SIMULATION OF BASE FLOW IN SUPERSONIC MAINSTREAM)

  • 신재렬;원수희;최정열
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.104-110
    • /
    • 2008
  • Detached Eddy Simulation (DES) is applied to an axisymmetric base flow at supersonic mainstream. DES is a hybrid approach to modeling turbulence that combines the best features of the Reynolds-averaged Navier-Stokes RANS) and large-eddy simulation (LES) approaches. In the Reynolds-averaged mode, the model is currently based on either the Spalart-Allmaras (S-A) turbulence model. In the large eddy simulation mode, it is based on the Smagorinski subgrid scale model. Accurate predictions of the base flowfield and base pressure are successfully achieved by using the DES methodology with less computational cost than that of pure LES and monotone integrated large-eddy simulation (MILES) approaches. The DES accurately resolves the physics of unsteady turbulent motions, such as shear layer rollup, large-eddy motions in the downstream region, small-eddy motions inside the recirculating region. Comparison of the results shows that it is necessary to resolve approaching boundary layers and free shear-layer velocity profiles from the base edge correctly for the accurate prediction of base flows. The consideration of an empirical constant CDES for a compressible flow analysis may suggest that the optimal value of empirical constant CDES may be larger in the flows with strong compressibility than in incompressible flows.

  • PDF