• 제목/요약/키워드: Small Flows

검색결과 494건 처리시간 0.03초

원형 제트 충돌 열전달과 유동 특성에 관한 실험적 연구 : 노즐 벽 두께와 노즐 출구 압력의 영향 (An Experimental Study on Heat Transfer and Flow Characteristics of a Circular Impinging Jet on a Flat Plate : Effects of Nozzle Wall Thickness and Nozzle Exit Pressure)

  • 윤상헌;양근영;손동기;최만수
    • 대한기계학회논문집B
    • /
    • 제23권10호
    • /
    • pp.1285-1295
    • /
    • 1999
  • An experimental study on heat transfer and flow characteristics of a circular impinging jet on a flat plate has been carried out. Of particular interests are the effects of nozzle wall thickness and nozzle exit pressure. Experimental apparatus has been designed to view heating plate coated by TLC from the opposite side of the nozzle in order to measure heat transfer rates for cases of very small nozzle to plate spacings. A visualization study of jet flows has also been performed. As the nozzle wall thickness increases at small nozzle to plate spacings, the effect of mixing is inhibited due to the confinement caused by the finite nozzle wall, consequently, heat transfer rates have been decreased. At small nozzle to plate spacings, heat transfer rates and nozzle exit pressures are increased together, therefore, enhancement of heat transfer at small nozzle to plate spacings should be considered in conjunction with the need of more fan power to generate the same Reynolds numbers.

신차단방식 SF$_{6}$ 가스 차단기의 소전류 차단성능 연구 (Investigation of Small Current Interruption Performance for New Type of Interrupting Chamber in SF$_{6}$ Gas Circuit Breaker)

  • 송원표;권기영;이재성;송기동;김맹헌;고희석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권11호
    • /
    • pp.519-526
    • /
    • 2005
  • This paper presents computer simulation results for developing new type of SF$_{6}$ Circuit Breaker in terms of cold gas flow after small current interruption. This cold gas flows down a nozzle into the chamber of a circuit breaker. There are many difficult problems in analyzing the gas flow due to complex geometry, moving boundary, shock wave and so on. When predicting the dielectric capability of a gas circuit breaker after interruption, the gas pressure and density distributions due to the cold gas must be considered in addition to the electrical field imposed across the gas. A self-coded computational fluid dynamics (CFD) program is used for the simulation of cold gas flow in order to evaluate the electrical field characteristic across open contacts and transient characteristics of insulations after small current interruption.

산업체 부설연구소의 정보기능에 관한 연구 (A Study on the Information Gathering Function of Research and Development Laboratories Established within Industrial Firms)

  • 조인숙
    • 한국문헌정보학회지
    • /
    • 제16권
    • /
    • pp.281-327
    • /
    • 1989
  • This dissertation is presented in two major parts. The first part presented in Chapter 3 attempts to verify the major hypothesis of the present study that the research and development laboratories(hereafter referred to R&D laboratories), establishd withine industrial firms to develop new technologies needed for their own industrial activities, may have another but very important functions to bring information on the externally generated technologies to attention of their respective management decision makers, eventually resulting in the transfer of technology; and such information functions of the R&D laboratories may be better performed by well-organised laboratories than by poorly-organised ones. The second part presented in Chapters 4, 5, 6 and 7 discusses, after the preceding hypotheses has been verified, some desirable situations of the R&D laboratories in facilitating the flow of information on new technologies developed in the world into their industrial firms, centering on the organisational positions and the major fields of interest of the person in charge of the R&D centers, services of the library and technological information office supporting the R&D laboratories, and frequencies of direct contacts of research and development workers with experts in the world and of participation in various conferences, seminars, workshops, exhibitions, etc. Now that there is no recognised instrument and method available for direct measurement of volume of technological information transfered into a particular industrial firm, the number of technologies introduced into a given firm is employed in the present study as an analogous parametre indicating volume of technological information transfered into the firm during a particular period of time. A logical attempt to justify the use of the indirect paramentre is made in Chapter two. vidences needed to verify the hypotheses of the present study are collected through the various publications of the Korea Industrial Research Institutes and other agencies and institutions related to industrial research activities, and through responses to the questionnaire posted to a sample of the 66 R&D laboratories on 6 May 1987 and returned by 30 August of the same year. Some findings and conclusions made in the study are summarised as follows: (1) More information on externally developed technologies flows into the industrial firm with a R&D laboratory of its own than into the industrial firm without one, and naturally, more chances of transfer of technologies are given to the former than to the latter (see 3. 2) (2) After establishing an R&D laboratory, more technological information flows into the industrial firm than before establishing one (see 3. 3) (3) More technological information flows into the industrial firm with a well-organised R&D laboraory than into the firm with a poorly-organised one (see 3. 4) (4) More technological information flows into the ndustrial firm where the director of its R&D laboratory has status qualified to participate in the highest managerial decision making processes of the firm than into the industrial firm where the director does not have such status (see 4. 2) (5) More technological information flows into the industrial firm where the director of R&D laboratory does not hold other positions within the firm than into the industrial firm where the director holds other positions (see 4.3) (6) There is evidence showing that quantities of technological information transfered into industriali firms vary with the case that the major background of the director of the R&D laboratory is the same as the main field of R&D activities of his or her laboratery, the case that the director's background is partly related to the field of R&D activities of the laboratory, and the case that the director's major background is different from the field of R&D activities of the laboratory (see 4.4) (7) More technological information flows into the industrial firm with the director of its R&D laboratory appointed from among professional research and development workers than into the industrial firm with the director of its R&D laboratory appointed from among general managers (see 4.5) (8) More technological information flows into the industrial firm with its R&D laboratory which has established a library service unit within its own jurisdiction than into the industrial firm with its R&D laboratory which has established a library service unit within its own jurisdiction than into the industrial firm with its R&D laboratory which uses a library within the firm but outside the laboratory (see 5. 1) (9) More echnological information flows into the industrial firm with a technological information office of its own than into the industrial firm without such an office (see 5. 2) (10) More technological information flows into the industrial firm with a large research and development staff in its R&D laboratory than into the industrial firm with a small staff in its R&D laboratory (see 5. 2) (11) More technological information flows into the industrial firm with its R&D laboratory whose staff members more frequently contact experts in the conferences, seminars, symposiums, and workshops held in foreign countries and novelties in the world's major exhibitions than into the industrial firm with its R&D laboratory whose staff members less frequently contact such experts and novelties (see 6. 2 ; 6. 3)

  • PDF

입사각이 고선회 터빈 동익 하류에서의 3차원 유동 및 압력손실에 미치는 영향 (Effects of Incidence Angle on the Three-Dimensional Flow and Aerodynamic Loss Downstream of a High-Turning Turbine Rotor Blade)

  • 채병주;이상우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2591-2596
    • /
    • 2007
  • The effect of incidence angle on the three-dimensional flow and aerodynamic loss in the downstream region of a high-turning turbine rotor blade has been investigated with a straight miniature five-hole probe. The incidence angle is changed to be +10, +5, 0, -10, -20, -30 and -40 degrees. The results show that the positive incidence reinforces the three-dimensional vortical flows within the turbine passage including the passage vortex, but the negative incidence weaken them significantly. A small increment in the positive incidence angle results in a remarkable aerodynamic loss increase, while increasing the incidence angle in the negative range leads to a very small change in the aerodynamic loss.

  • PDF

Multiscale method and pseudospectral simulations for linear viscoelastic incompressible flows

  • Zhang, Ling;Ouyang, Jie
    • Interaction and multiscale mechanics
    • /
    • 제5권1호
    • /
    • pp.27-40
    • /
    • 2012
  • The two-dimensional incompressible flow of a linear viscoelastic fluid we considered in this research has rapidly oscillating initial conditions which contain both the large scale and small scale information. In order to grasp this double-scale phenomenon of the complex flow, a multiscale analysis method is developed based on the mathematical homogenization theory. For the incompressible flow of a linear viscoelastic Maxwell fluid, a well-posed multiscale system, including averaged equations and cell problems, is derived by employing the appropriate multiple scale asymptotic expansions to approximate the velocity, pressure and stress fields. And then, this multiscale system is solved numerically using the pseudospectral algorithm based on a time-splitting semi-implicit influence matrix method. The comparisons between the multiscale solutions and the direct numerical simulations demonstrate that the multiscale model not only captures large scale features accurately, but also reflects kinetic interactions between the large and small scale of the incompressible flow of a linear viscoelastic fluid.

PIV Measurement of Inlet and Outlet Flow of Contra-Rotating Small-Sized Cooling Fan

  • Shigemitsu, Toru;Fukuda, Hiroaki;Fukutomi, Junichiro
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권2호
    • /
    • pp.175-181
    • /
    • 2016
  • Contra-rotating rotors have been adopted for some of the cooling fans to meet the demand for the high pressure and large flow rate. Therefore, it is important to clarify its inlet and outlet flows by experiments for the high performance and stable operation. PIV measurements were conducted at the design and partial flow rates. In the present paper, the inlet and outlet flow conditions of the contra-rotating small-sized cooling fan with a 40mm square casing are studied by using PIV measurement. Furthermore, improvements of the flow condition and design guideline to increase the performance were discussed based on the experimental results.

정전기에 의한 CMOS DRAM 내부 회오의 파괴 Mechanism과 입력 보호 회로의 개선 (ESD damage mechanism of CMOS DRAM internal circuit and improvement of input protection circuit)

  • 이호재;오춘식
    • 전자공학회논문지A
    • /
    • 제31A권12호
    • /
    • pp.64-70
    • /
    • 1994
  • In this paper, we inverstigated how a parricular internal inverter circuit, which is located far from the input protection in CMOS DRAM, can be easily damaged by external ESD stress, while the protection circuit remains intact. It is shown in a mega bit DRAM that the internal circuit can be safe from ESD by simply improving the input protection circuit. An inverter, which consists of a relatively small NMOSFET and a very large PMOSFET, is used to speed up DRAMs, and the small NMOSFET is vulnerable to ESD in case that the discharge current beyond the protection flows through the inverter to Vss or Vcc power lines on chip. This internal circuit damage can not be detected by only measuring input leakage currents, but by comparing the standby and on operating current before and after ESD stressing. It was esperimentally proven that the placement of parasitic bipolar transistor between input pad and power supply is very effective for ESD immunity.

  • PDF

태양광 및 소단위 풍력발전용 변압기 없는 인버터 (Transformer-less Inverter for Photovoltaic and small unit Windturbine System)

  • 박영산;김윤식;이성근;안병원;배철오
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 추계종합학술대회
    • /
    • pp.333-336
    • /
    • 2003
  • 태양광발전 및 소단위 풍력발전에 사용할 수 있는 변압기 없는 인버터를 설계하였다. 멀티 스위칭 방법에 의한 승압쵸퍼회로와 단상 풀브리지 인버터로 구성하였으며 소형화, 저 비용화를 위하여 변압기 없는 방식으로 설계하였다. 변압기 없는 시스템에서 문제가 될 수 있는 접지누설전류의 저감을 위해서는 스압쵸퍼의 스위칭기법 및 인버터 스위칭 등을 통하여 해결하였다.

  • PDF

분사압력변화가 충돌분무특성에 미치는 영향에 관한 수치적 고찰 (Numerical Analysis of the Effect of Injection Pressure Variation on Impaction Spray Characteristics)

  • 김승철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권1호
    • /
    • pp.47-53
    • /
    • 1999
  • Small compression-ignition direct injection engines have been developed as a measure to improve a fuel efficiency and reduce harmful exhaust gases. Those small engines generally employ high injection pressure increase on the spray impacting on a wall is discussed in this paper. The gas phase is modelled by the Eulerian continuum conservation equations of mass momentum energy and fuel vapour fraction. The liquid phases is modelled following the discrete droplet model approach in Lagrangian form and the droplet wall interaction is modelled as a func-tion of the velocity normal to impaction lands. The droplet distributions vapor fractions and gas flows are analyzed in various injection pres-sure cases. The penetrations of wall spray and vapor increase and the Sauter mean diameter decreases with increasing injection pressure.

  • PDF

다수의 주상체들의 저진폭 동위상 진동에 의한 2차 정상유동 해석 (Secondary Steady Flows Due to the Small-Amplitude In-Phase Oscillation of Multi-Cylinders)

  • 김성균
    • 대한기계학회논문집B
    • /
    • 제20권2호
    • /
    • pp.649-658
    • /
    • 1996
  • Small-amplitude harmonic oscillations of multi-cylinders are considered both experimentally and theoretically. For the theoretical model, the flow regime is separated into inner and outer regions. In the inner region, the flow is governed by the generalized Stokes boundary layer equation. In the outer region, the full Navier-Stokes equation for the steady streaming flow is solved numerically by using ADI scheme and FVM coupled with the boundary integral method. Flow visualization experiments are conducted by using the Laser Sheet Image Technique. The case of two circular cylinders and square cylinders with variable distances are chosen as a typical example. Although experimental results are based on the flow in the finite domain, both experimental and numerical results agree well qualitatively. As the separation of cylinders is increased, a numerical result shows the asymptotic convergence to a single cylinder case.