• Title/Summary/Keyword: Small Fan

Search Result 247, Processing Time 0.023 seconds

A Study on the Structure of Instantaneous Flow Fields of a Small-Size Axial Fan by Large Eddy Simulation (대규모 와 모사에 의한 소형축류홴의 순간유동장 구조에 대한 연구)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.22 no.6
    • /
    • pp.28-35
    • /
    • 2018
  • The large-eddy simulation (LES) was carried out to evaluate the instantaneous vector and vorticity profiles of a small-size axial fan (SSAF) at the operating point of full-flowrate. The downstream flow of the SSAF exhibits a shorter axial flow when not fully developed, especially the stronger vortex appears at the edge near the flow end. On the other hand, the downstream flow of the SSAF exhibits a longer axial flow, and the weaker vortex appears at the edge near the flow end when the flow is sufficiently developed. Moreover, in the downstream of the SSAF, a periodic and intermittent flow pattern appears at the edge showing the axial flow, and the instantaneous vorticity contour lines showing the form of a circle group are distributed at specific intervals from the downstream region of the blade tip, which is considered to be the result of the intermittency phenomenon influenced by the number of blades and the number of revolutions.

A study on the ventilation control method of road tunnel for small vehicles (소형차 전용 도로터널의 환기기 제어방안에 대한 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young;Chang, Ji-Don
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.749-762
    • /
    • 2019
  • In recent years, in urban areas, underground of roads are being promoted in order to resolve traffic congestion and to secure green spaces, and due to the low ratio of large vehicles, they are planned or constructed as road tunnels for small cars only. In addition, the tunnels being built in the city is a tendency to be enlarged to play the role of main roads. Accordingly, the capacity of the ventilation system is increasing and various ventilation methods are required, and the importance of maintenance after the completion of the tunnel such as the operating cost of the ventilation system is emphasized. Therefore, the need for optimization of the operation stage for reducing the power consumption of the ventilation system and the study of the ventilation system operation control logic is increasing. In this study, the study on the necessity of the optimization of operation stage and control logic of the ventilation system was carried out to realize the energy-saving operation for the small car only passing through tunnels which is applied of ① jet fan and combination ventilation system (② jet fan + air purifying equipment, ③ jet fan + vertical shaft, ④ jet fan + supply air semi-transverse). As a result of this study, there can be various operating combinations in the case of the combined ventilation system, and even though the amount of ventilation air is the same, the operating power varies greatly according to the operating combinations. It was found that operating the axial fan first rather than the jet fan first operation method has an effect on power saving.

Implementation of Automation System for the Fluid Analysis of Axial Fan Using Supercomputer (슈퍼컴퓨터 활용 축류팬 유동해석 자동화 시스템 개발)

  • Kim, Myung-Il;Lee, Seung-Min;Lee, Sang-Min
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.288-291
    • /
    • 2008
  • Recently, the importance and necessity of engineering analysis has shown a steady growth. However, researchers working in small and medium enterprises know little about the usefulness of engineering analysis and suffer from lack of technical knowledge. Axial fan is air fluid machinery in various fields of industry such as automobile, electric appliance, and heavy machinery. It is also a time and budget consuming equipment to develop the axial fan through physical experiments. In order to overcome this problem, we have designed and developed a web-base automated simulator for axial fan's fluid analysis using supercomputer. Automated simulator means that all of processes for engineering analysis including pre-process, solving, and post-process can be performed automatically without user intervention after transferring fan model(CAD files) made by user. After executing the simulator with some parameters, user can receive the report including pressure P and flow rate Q. In this paper, we introduce the architecture of our easy and efficient automated engineering analysis simulator, related techniques and result of development.

  • PDF

Experimental Study of a Small Desalination Device Using Engine Waste Heat (엔진 폐열을 이용한 소형담수화장치의 실험적 연구)

  • Lee, Imkyeong;Ko, Gwang Soo;Park, Youn Cheol
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.1
    • /
    • pp.12-19
    • /
    • 2022
  • Desalination has the advantage of being easy to supply water resources. However most desalination devices are developed mainly for large plants and it is not common to use desalination system for a small fishing ship. More than 50% of the input fuel energy of the small shipbuilding's engine is wasted without reused in a ship, and it is necessary to improving the fuel efficiency of the small fishing ship. In this study, a desalination device using waste heat from engine of the ships was developed. As results, it was found that if the condensing chamber uses a fan to circulate the water vapor, the freshwater production was up to 40.0% higher, and the freshwater production efficiency was up to 30.1% increased when the fan was operated.

A study on the Design and Analysis of 300W BLDC motor for a cooling fan (Cooling Fan 구동용 300W BLDC motor 설계 및 특성해석에 관한 연구)

  • Ahn, Young-Il;Park, Chang-Soon;Maeng, Kyung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.104-106
    • /
    • 2003
  • In recent years for propulsion of cooling fan in cars are more used electrical motors than the engine direct coupled type. But the electrical motor which is now used has the brush and the commutator. Because of the brush and the commutator the electrical motor has short life time, low efficiency and mechanical- electrical noise. Therefore it is tried to develope brushless dc motor. The motor is located in the hot air from the radiator. The motor temperature increases high and the increasing of the motor temperature rolls big in its character. The cooling fan motor has relative small in size and input voltage is low. For 300 w output power must be the current of the motor high which causes high copper loss. In this paper will be tested and analysed characteristics of a dc motor which is now used for cooling fan and a BLDC motor will be designed with same character of the brushed motor and with considering of improvement of the efficiency. After design the motor should be analysed and tested.

  • PDF

The Survey of Fire Hazard of Fan in Manufacturing Industries (제조 사업장의 환풍기 화재위험성 조사)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.21-29
    • /
    • 2013
  • The short circuit and overload is presented by main cause of electrical fire. However, 85% of the fan directly connected the outlet box without switch in total 110 fans as a research in manufacturing industries. In installation direction of vertical type fans which was placed on the horizontal surface, only 39 vertical type fans were placed on vertical surface and 71 fans were placed on the horizontal type. The installation direction of the fans warns of the risk of the fire hazard due to the motor stall to the user manual of the maker. However, it is the representative nonconformity example of construction which the people or builder disregards. In addition, the condition of ground connection with the earth leakage prevention was investigated in grounding of 5 fans, non-grounding of 105 fans. The double insulation structure is generally used for small fan and it can't connect ground wire as electric plug of non-grounding type. However, industrial iron fan needs ground wire for electric leakage and to protect against electric shock.

Experimental Study on the Aerodynamic Interaction of the Rotor and Stator for the Ducted fan UAV (덕티드 팬 무인기의 동익과 정익 공력상호작용에 대한 실험적 연구)

  • Ryu, Min-Hyoung;Cho, Lee-Sang;Cho, Jin-Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.387-391
    • /
    • 2009
  • The experimental study on the ducted fan for the propulsion system of a small UAV has been performed. In this paper, to investigate the three-dimensional unsteady flow field characteristics of the ducted fan, it was measured by using a $45^{\circ}$ inclined hot-wire from hub to tip at inlet, behind the rotor and outlet of the ducted fan. The hot-wire signal data was acquired at fixed yaw angle. The data was averaged by using the PLEAT (Phase Locked Ensemble Averaging Technique), and then three of non-linear equations were solved simultaneously by using the Newton-Rhapson numerical method. Flow characteristics such as tip vortex, secondary flow and tip leakage flow were confirmed through axial, radial and tangential contour plot.

  • PDF

A numerical study on the noise reduction methods of centrifugal impeller (원심형 임펠러의 저소음화에 대한 연구)

  • Jeon, Wan-Ho;Chung, Phil-Joong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.129-136
    • /
    • 2000
  • Centrifugal fans are widely used and the noise generated by these machines causes one of the most serious problems. In general, the centrifugal fan noise is often dominated by tones at BPF(blade passage frequency) and its higher harmonics. This is a consequence of the strong interaction between the flow discharged from the impeller and the cutoff in the casing. However, only a few researches have been carried out on predicting the noise because of the difficulty in obtaining detailed Information about the flow field and casing effects on noise radiation. The objective of this study is to develop a prediction method for the unsteady flow field and the acoustic pressure field of a centrifugal fan, and to calculate the effects of small vanes that are attached in original impeller - Splitter impeller. We assume that the impeller rotates with a constant angular velocity and the flow field around the impeller is incompressible and inviscid. So, a discrete vortex method (DVM) is used to model the centrifugal fan and to calculate the flow field. The force of each element on the blade is calculated by the unsteady Bernoulli equation. Lowson's method is used to predict the acoustic source. The splitter impeller changes the acoustic characteristics as well as performance. Two-splitter type impeller and splitter impeller which splitter locates in jet region are good for acoustic characteristics.

  • PDF

Design Optimization by the Correlation between the Design Parameter and the Sound Quality of Small Turbo-fan (소형 터보홴 설계인자와 음질의 상관관계에 의한 설계 최적화)

  • Kim, Hooi-Joong;Jung, Young-Gyu;Lee, Jung-Soo;Lee, Seung-Bae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.5 s.110
    • /
    • pp.485-494
    • /
    • 2006
  • The state-of-the-art of low-noise fan design usually includes the consideration of optimal sound level and sound quality. The influential design parameters of the noise level by the centrifugal fan were selected based on the preliminary test. The centrifugal fans were designed according to the experiment plan method by specifying the selected design parameters. The experiment with these machined mock-up's of centrifugal impellers suggested the major design parameters among many, having impacts upon the indices of sound quality (e.g. loudness, sharpness, roughness and fluctuation strength) at the same operation point. With the response surface method, the major design parameters selected thereafter were analyzed to estimate each contribution upon the sound quality of the centrifugal fan, and the optimal values were drawn by the consideration of the sound quality levels and their regression equations. In addition, the validity of the regression equations was numerically verified by means of the coefficient of determination. Furthermore, the mechanism by which the centrifugal fan impeller influences the determinants of its sound quality was suggested.

Survey of Geomorphological Resources of 'Daegu Innovation Town' Development Plan Area (대구 혁신도시 개발예정지의 지형자원 조사)

  • Son, Myoung-Won
    • Journal of the Korean association of regional geographers
    • /
    • v.14 no.2
    • /
    • pp.173-188
    • /
    • 2008
  • In order to make comparative analysis of geomorphological changes caused by urban development, I surveyed the distribution of geomorphological resources of 'Daegu Innovation Town' development plan area. The results are as follow: (1) At the front of small valleys of back-mountains are formed small alluvial fans, and at the side of small valleys are distributed hills connected with back-mountains. (2) As small valley erode laterally hills, vertical bluffs and planner bedrock riverbed are formed, and in some riverbed are appeared mud cracks and ripple marks. (3) The depth of valley in alluvial fan of 'Sinseo District' is 7m. In Sinseocheon valley dissecting alluvial fan, fluvial terraces 2m high above riverbed are distributed. Those terraces were formed while alluvial fan was dissected after last glacial period.

  • PDF