• Title/Summary/Keyword: Small Arm

Search Result 296, Processing Time 0.026 seconds

Heavy Metal Pollution and Management Direction of Small Arms Firing Ranges (소화기 사격장의 중금속 오염 특성 및 관리방향 제시)

  • Kim, Hong-Hyun;Jeong, Sangjo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.724-734
    • /
    • 2019
  • This study selected a representative small arm firing range and analyzed the distribution of heavy metal pollutants such as Pb, Cu, Zn, etc. For this the concentrations of heavy metals in soils, roots and leaves of plants, and water of the small arm firing range were measured. The concentrations of heavy metals in the effluent were also checked during precipitation. The concentration of lead in the samples collected from the top soil(0-5 cm) and sub soil(5-50 cm) near the target in the small arm firing range exceeded the concern level of the Soil Environment Conservation Act of Korea, but not in other soil samples. Plants that grow in soil heavily contaminated with lead showed a high lead concentration, especially in roots. However, the concentration of lead in effluent from the small arm firing range was less than 0.02 ppm. The concentration of copper and zinc in the small arm firing range did not surpass the concern level of the Soil Environment Conservation Act of Korea. Through this study more accurate information on the distribution of heavy metal pollution in the soil of the small arm firing range was obtained. Based on this research, we can conclude that some facility improvements can reduce the spreading of pollutants in the currently used small arm firing range and contribute to the design and operation of advanced small arm firing ranges.

Ergonomic studies of arm shapes and sleeve: Classification of arm shapes (상지형태와 의복소매에 관한 인간공학적 연구 (제1보))

  • 함옥상;조경애
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.29-45
    • /
    • 1997
  • This study aims at designing sleeves which are suitable for arm shapes and arm movements. With the samples of of ordinary 24 women aged from 20 to 22, the arm shapes and movements were measured 3-dimensionally using a motion analyzer and a sonic digitizer, and then clasified into three characteristic types (A, B, and C). Our analysis leads to the following conclusion. The factors classifying arm shapes are the length from acromion to posterior armpit point, arm hole length, the cap height, difference in height between anterior and posterior armpit points, armhole circumference, upper arm circumferemce, armhole depth, and underarm circumference. The characteristics of arm type A is that the armhole depth and the length from acromion to posterior armpit point are the largest, while the circumference inbe- tween upper arm and elbow is the smallest among the three arm types. Thus, the large circumference difference between upper and lower arms is the most notable in arm type A. The factors classifying arm shapes for arm type B are the smallest except for the circumference inbetween upper arm and elbow which is larger than that for arm type A. The circumference difference betweemn upper and lower arms is small for arm type B. Arm type C has the smallest armhole depth, while other factors are similar to those for arm type B. In type C, the size of upper arm is comparatively small on the frontal plane, while it is the largest on the sagital plane.

  • PDF

An Ergonomic Study of the Sleeve Pattern According to Arm Movement -on Expansion and Contraction of the Skin Surface of the Arm- (팔의 동작에 따른 소매 원형의 인간공학적 연구 -팔의 피부면 신축을 중심으로-)

  • 함옥상
    • Journal of the Korean Home Economics Association
    • /
    • v.19 no.3
    • /
    • pp.21-32
    • /
    • 1981
  • Clothing must have the individual beauty and the function that one can do one's body movement freely. therefore, from the human engineering view point, the exact measurement of the human body and the analysis of it's results must be applied to clothing because the arm works most. In this study, the skin surface of arm was investigated by shell made of Alginate of each movement. And by sometic method the rate of expansion and contraction of each section, inter-relation among the bust girth, axillary arm girth and scye girth and between the shoulder length right and the under axilla waist length were calculate4d. With these results, cap height, breadth of a sleeve and arm hole girth of existing sleeve pattern have been compared and analysed. The results are as follows; 1) According to the developmental figures of shell, the whole area change was small but that of shape was remarkable in M 4, 9, 13. The change of the Block 1 was particular. 2) Over arm length was contracted in all movements except M6 and under arm length expanded. The changes of sections a, b, c are large, while those of sections d, e are small. 3) In terms of latitudes, change of fore-arm region was small. The rate of scye girth varied from 14.3% of M13 to-5.6% of M2. The breadth of a sleeve expanded in all movements, and especially the front region expanded more than the back. 4) The relation between the shoulder length right and under axilla waist length, in all occasions, was contracted mutually, and one contracted, the other expanded. Therefore, in clothing construction when we consider the function of the arm it is better to widen the arm hole and the breadth of a sleeve at the same time than no widen the shoulder length by lowering the upper part of the upper side seam line.

  • PDF

Structural design of small form factor swing arm type actuators with thermal stability (열안정성을 고려한 초소형 정보저장기기용 액추에이터 구조설계)

  • Park, Chul;Yoo, Jeong-Hoon;Park, No-Cheol;Park, Young-Pil;Shimano, Takeshi;Nakamura, Shigeo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.3
    • /
    • pp.208-213
    • /
    • 2006
  • The present state of the design of swing arm actuators for optical disc drives is to obtain the high efficient dynamic characteristics within a very compact volume. As a necessary consequence, the need of the small form factor (SFF) storage device has been arisen as major interests in the information storage technology. In this paper, we suggest the miniaturized swing arm type actuator that has high efficient dynamic characteristics for SFF optical disk drive (ODD). For the operating mechanism, it uses a tracking electromagnetic (EM) circuit for a focusing motion together. Moreover, due to the size constraint, the thermal stability of optical head is important. Therefore, the actuator is designed to emit the heat, which is generated by optical pick-up, along the actuator body easily. Initial model is designed based on the topology optimization method considering the thermal conductivity. Then, the structural parts of the actuator are modified to maintain the high sensitivity and to have wide control bandwidth by the design of experiments method (DOE) and new concept of decreasing mass and inertia. Finally, a swing arm type actuator for SFF ODD is suggested and its dynamic characteristics are verified.

  • PDF

Design of a Small Form Factor Swing Arm type Actuator using Design of Experiments (실험계획법을 이용한 초소형 스윙암 액추에이터의 설계)

  • Park Chul;Yoo Jeong-Hoon;Park No-Ceol
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.813-819
    • /
    • 2006
  • The state of the art for the design of swing ann actuators for optical disc drives is to obtain the high efficient dynamic characteristics, especially for the small size for the mobile information devices, It is affected by the need of consumers who wants the portable digital storage devices maintaining highly functional and removable characteristics of the optical disk drive (ODD). As a necessary consequence, the need of the small form factor (SFF) storage device has been considered as an important part in the information storage technology. In this paper. we suggest a new conceptual miniaturized swing arm type actuator that has high efficient dynamic characteristics as well as satisfies the sensitivity and the heat emission requirements for the SFF-ODD. It also uses a tracking electromagnetic (EM) circuit for a focusing motion. Due to the size constraint, the thermal problem of optical head arises; therefore, we design an efficiently heat emitted structure for the actuator.

  • PDF

Study of 7 Degree of Freedom Desktop Master Arm (7자유도 탁상식 마스터 암의 설계 연구)

  • Choi, Hyeungsik;Lee, Dong-Jun;Ha, Kyung-Nam
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.6
    • /
    • pp.59-65
    • /
    • 2012
  • In this research, a novel mater arm was studied as a teaching device for an underwater revolute robot arm used as a slave arm. The master arm was designed to be a seven-degree-of-freedom (DOF) structure, with a structure similar to that of the slave arm, and to be desktop size to allow it to be worn on a human arm. The master arm with encoders on the joints was used as an input device for teaching a slave robot arm. In addition, small electric magnets were installed at the joints of the master arm to generate the haptic force. A control system was designed to sense excessive force and torque in the joints of the master arm and protect it by controlling the position and velocity of the slave arm through the encoder signal of the master arm.

Revision of Lateral Arm Free Flap; Can It be a Substituete for Radial Forearm Free Flap? (외측상박 유리피판의 유용성에 관한 재조명; 전박부 유리피판을 대체할 수 있는가?)

  • Ahn, Hee-Chang
    • Archives of Reconstructive Microsurgery
    • /
    • v.6 no.1
    • /
    • pp.80-86
    • /
    • 1997
  • The lateral arm flap was reported first by Song et al. in 1982, and Katsaros and colleagues described an anatomic study and clinical cases in 1984. This flap is thin, has relatively constant vascular anatomy, and provides relatively acceptable scar at the donor site. Despite its many advantages its wide application has been limited by its short vascular pedicle with small diameter of lumen, and its small skin paddle. We studied its anatomical structure to get longer length of vascular pedicle, wide diameter and thinner part of flap beyond the lateral condyle through 6 fresh cadaver dissection and dye injection study. We experienced 21 cases of lateral arm free flaps and 26 cases of forearm free flaps from May, 1992 to January, 1996. We compared its usefulness with forearm free flaps in the aspects of donor morbidity, operative factors, quality of flap, and versatility. In conclusion, lateral arm flap can replace the role of forearm flap in most cases so that patient's donor morbidity can be reduced especially in the women.

  • PDF

ANALYSIS OF THREE-ARM PWM UPS

  • Uematsu, Takeshi;Hirano, Noriyuki;Ninomiya, Tamotsu;Syoyama, Masahito
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.818-823
    • /
    • 1998
  • A three-arm PWM UPS is realizable low price and small size UPS. In this UPS configuration, the center arm operates in both PWM converter mode and PWM inverter mode. Therefore, the operation of this UPS differs from the conventional UPS. In this paper, the three-arm PWM UPS is analyzed and a trial product is realized.

  • PDF

Design of a Torque Arm Pin and Elastomeric Bushings for the Three-point-Suspension Gearbox of a Wind Turbine (풍력발전기용 3점 지지 기어박스의 토크암 핀 및 탄성중합체 부싱 설계)

  • Shim, Sung Bo;Nam, Ju Seok
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.2
    • /
    • pp.199-204
    • /
    • 2017
  • In this study, analytical methods for designing a torque arm pin and elastomeric bushings of a conventional-type three-point-suspension gearbox of a wind turbine are investigated. The design loads for the torque arm were derived by considering the effects of the transmitted torque and self-weight of the gearbox. Based on the design loads, design methods for the torque arm pin and elastomeric bushings were introduced in the terms of material and size selection. Finally, a small-scale conventional-type gearbox was designed by applying the derived design methods. This study is an elementary and analytical study for the design of the torque arm pin and elastomeric bushings. It is necessary to verify and supplement the results further through extensive experimentation.

A Comparative Study of Blood Pressure According to Cuff Size and Measurement Site (커프크기와 측정부위에 따른 혈압측정치 비교 연구)

  • Song, Mi-Ryeong;Kim, Eun-Kyung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.16 no.1
    • /
    • pp.6-13
    • /
    • 2009
  • Purpose: The purpose of this study was to identify differences in blood pressure according to cuff size and measurement sites of the participants. Method: The participants consisted of 50 women and 50 men whose upper arm circumference was $26\sim30cm$. They had no chronic illness and gave consent to participate. Blood pressure of the wrist was measured in the sitting position, the upper arm with a standard cuff, large and small cuffs were used for measurement in supine position and the thigh in prone position. The data were analyzed with paired t-test using SPSS 12.0 program. Result: The data for the upper arm showed a difference in systolic and diastolic blood pressure depending on the site of measurement. There was a significant difference between measurements with a standard cuff and measurements with large and small cuffs. The systolic blood pressure of the wrist and the thigh were significantly lower than that of the upper arm. Conclusion: These results suggest that the selection of an appropriate cuff is an essential element in ensuring accuracy when measuring blood pressure and differences in systolic blood pressure for the upper arm, wrist and thigh indicate the need to record the measuring site when measuring blood pressure.

  • PDF