• Title/Summary/Keyword: Slug

Search Result 240, Processing Time 0.023 seconds

Effect of Various Shapes of Mixer Geometry on Two-Phase Flow Patterns in a Micro-Channel (마이크로 채널 내 혼합부 형상이 2상 유동 양식에 미치는 영향에 대한 연구)

  • Lee, Kwan Geun;Lee, Jun Kyoung;Park, Taehyun;Kim, Gyo Nam;Park, Eun Ju
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.75-80
    • /
    • 2015
  • The effect of inlet mixer geometries on the two-phase flow patterns in square micro-channel with $600{\times}600{\mu}m$ was investigated experimentally in this paper. The 4 different mixer configurations based on the Y, Impacting, and two T types (gas and liquid inlets were switched) were used. The test fluids were nitrogen and water. The liquid and gas superficial velocities were 0.01~10 m/s and 0.1~100 m/s, respectively. Several distinctive flow patterns, namely, annular, slug-annular, slug, slug-bubbly, bubbly, and churn flow could be seen. The flow pattern maps for each mixer were suggested, and it can be concluded that two-phase flow patterns are not very sensitive to the mixer geometries. But the mixing behaviors of gas and liquid for each mixer were different for slug and bubbly flow. Thus, the characteristics of slug and bubble for each case were not same.

Study on the Characteristics of Bubble and Liquid Slugs for Gas-Liquid Taylor Flow in a Rectangular Micro-channel (사각 마이크로 채널 내 Taylor Flow의 기포 및 액체 슬러그 유동 특성에 대한 연구)

  • Lee, Jun Kyoung;Lee, Kwan Geun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.520-526
    • /
    • 2015
  • The characteristics of gas-liquid Taylor (Slug) flow in a square micro-channel of $600{\sim}600{{\mu}m}$ were investigated experimentally in this paper. The test fluids were nitrogen and water. The liquid and gas superficial velocities were 0.01~3 m/s and 0.1~3 m/s, respectively. Bubble and liquid slug length, bubble velocity, and frequency were measured by analyzing optical images using a high speed camera. Bubble length decreased with higher liquid flow rate, which increased dramatically with higher gas flow rate. However, slug length did not vary with changes in inlet liquid conditions. Additionally, bubble velocities and frequencies increased with higher liquid and gas flow rates. It was found that measured bubble lengths were in good agreement with the empirical models in the existing literature, but slug lengths were not.

Numerical study on pressure drop with moving contact lines of dry slug flow in a hydrophobic minichannel (소수성 미니채널 내 움직이는 접촉선을 가진 액체슬러그의 압력 강하에 대한 수치해석)

  • Jeon, Jun Ho;Park, Su Chung;Yu, Dong In;Kim, Tae Hun;Lee, Yeon Won
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.3
    • /
    • pp.116-121
    • /
    • 2020
  • In this study, a single-phase analysis of droplet slug with different contact angles was performed based on the visualization of experimental results. Droplet slug - flowing between gases in a hydrophobic mini channel - moves with a triple contact line without a gas liquid film on the wall. The results show that the rotational flow inside the droplet occurred; this was compared and verified with the results of two-phase analysis. The pressure field shows pressure rise at the front and rear ends. The effective length - the section that satisfies the laminar flow condition - became shorter as the droplet velocity increased. The Choi's correlation for the effective length agrees with this analysis results with a slight difference. This difference is judged as the difference in the contact angle of the slug model.

Multiple Slug and Pumping Tests for Quality Enhancement of Hydraulic Parameter Estimates (순간수위변화 및 양수시험을 통한 수리상수 추정의 문제점 분석)

  • 이진용;이강근;정형재;배광옥
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.1
    • /
    • pp.14-22
    • /
    • 1999
  • Slug and pumping tests have been widely used to obtain hydraulic parameter estimates in the field. Although a variety of sources of error and uncertainty can be involved in the course of the test performance and data analysis, serious considerations on these sources are often neglected. In this study these various sources of error and uncertainty are analyzed or discussed using repeated slug and pumping test data and some guide lines are suggested to improve quality of parameter estimates from the slug and pumping tests.

  • PDF

Use of the Modified Linear Curve Fitting Method in Analyzing Slug Tests to Evaluate Hydraulic Conductivity of Vertical Cutoff Walls (순간 변위시험 (Slug Test)을 이용한 연직차수벽의 투수계수 산정시 수정된 Linear Curve Fitting 방법의 적용)

  • Choi, Hang-Seok;Daniel David E.
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.338-347
    • /
    • 2006
  • 연직차수벽은 오염지역이나 폐기물 매립장에서 오염된 지하수 (때로는 오염된 수증기) 흐름을 차단하거나 또는 오염지역의 정화처리시 효율을 높이기 위하여 외부로부터 지하수 흐름을 막기 위해 설치된다. 이 논문에서는 연직차수벽의 가장 중요한 설계요소인 차수벽체의 현장 투수성을 평가하는 방법들중 가장 보편적으로 사용되는 단공식 순간 변위시험 (slug test)을 소개한다. 연직차수벽에서 실행된 단공식 순간 변위시험 결과를 해석하기 위해서, 연직차수벽의 압축성과 기하학적인 특성을 고려한 수정된 linear curve fitting 방법을 제안하고 그 적용성을 case study를 통해 평가한다. 기존의 대수층 투수계수 산정에 이용된 curve fitting 방법들에 비하여 수정된 linear curve fitting 방법은 보다 정확한 연직차수벽체의 투수성을 평가하도록 한다.

  • PDF

A Real-Time Measurement of Slug Flow Using Electromagnetic Flowmeter with High frequency Triangular Excitation (고주파 삼각파 여자법을 사용한 실시간 슬러그 유동 측정용 전자기유량계)

  • Ahn, Yeh-Chan;Cha, Jae-Eun;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1570-1577
    • /
    • 2002
  • In order to investigate the characteristics of two-phase slug flow, an electromagnetic flowmeter with 240Hz triangular AC excitation was designed and manufactured. The signals and noise from the flowmeter were obtained, and analyzed in comparison with the observations with a high speed CCD camera. The uncertainty of the flowmeter under single-phase flow was $\pm$ 2.24% in real-time. For two-phase slug flow, electromagnetic flowmeter provided real-time simultaneous measurements of the mean film velocity around Taylor bubble and the relative location and the length of the bubble. Besides, it is an easier and cheaper method for measuring mean film velocity than others such as photochromic dye activation method or particle image velocimetry.

Identification of Two-Phase Flow Patterns in a Inclined Duct Based upon a Statistical Analysis of Instantaneous Pressure Drop (순간압력강하치의 통계적 해석을 통한 경사관내 2상유동양식의 판별)

  • Lee, S.C.;Lee, J.P.;Kim, J.Y.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.5
    • /
    • pp.590-597
    • /
    • 1988
  • Characteristics of flow regime transitions in inclined upwards gas-liquid two-phase flow have been investigated based upon a statistical analysis of instantaneous pressure drop curves through an orifice. The probability density functions of the curves indicate distinct patterns depending upon two-phase flow regime, which are very similar to those of horizontal two-phase. The dimensionless intensity of fluctuations of the pressure drops sharply change as the flow transitions such as plug-slug, pseudo slug-slug and annular-slug take place. The effects of inclination angle on the flow regime transitions have been also investigated. The results show that the method to identify the flow pattern based upon the statistical analysis of instantaneous pressure drops is suitable for inclined flow as well as horizontal flow.

  • PDF

A Calculation Model for Fuel Constituent Redistribution and Temperature Distribution on Metallic U-10Zr Fuel Slug of Liquid Metal Reactors

  • Nam, Cheol;Hwang, Woan
    • Nuclear Engineering and Technology
    • /
    • v.30 no.6
    • /
    • pp.507-517
    • /
    • 1998
  • Unlike conventional fuel types, fuel constituent redistribution and sodium intrusion into the fuel slug are the unique phenomena of the irradiated metallic fuel. A thermal calculation model on metallic U-10 wt.%Zr fuel rod for LMRs is developed with considerations given to these phenomena. The amount of constituent redistribution is estimated based on the thermotransport process. The temperature profile of fuel slug is predicted by taking into account of Zr redistribution, porosity formation and sodium logging effects. A sample calculation is performed and compared to experimental data in literature. As a result, the predicted redistribution and temperature profile are well agreed with experimental data, assuming that 15 times increment of ex-reactor diffusivity, $Q_{r}$ $^{*}$ is -50 kJ/mole and sodium is infiltrated only outside of the fuel slug. Furthermore, the redistribution effects on fuel integrity and fuel temperature profile are discussed.d.

  • PDF

Flow Near the Meniscus of a Pressure-Driven Water Slug in Microchannels

  • Kim Sung-Wook;Jin Song-Wan;Yoo Jung-Yul
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.710-716
    • /
    • 2006
  • Micro-PIV system with a high speed CCD camera is used to measure the flow field near the advancing meniscus of a water slug in microchannels. Image shifting technique combined with meniscus detecting technique is proposed to measure the relative velocity of the liquid near the meniscus in a moving reference frame. The proposed method is applied to an advancing front of a slug in microchannels with rectangular cross section. In the case of hydrophilic channel, strong flow from the center to the side wall along the meniscus occurs, while in the case of the hydrophobic channel, the fluid flows in the opposite direction. Further, the velocity near the side wall is higher than the center region velocity, exhibiting the characteristics of a strong shear-driven flow. This phenomenon is explained to be due to the existence of small gaps between the slug and the channel wall at each capillary corner so that the gas flows through the gaps inducing high shear on the slug surface. Simulation of the shape of a static droplet inside a cubic cell obtained by using the Surface Evolver program is supportive of the existence of the gap at the rectangular capillary corners. The flow fields in the circular capillary, in which no such gap exists, are also measured. The results show that a similar flow pattern to that of the hydrophilic rectangular capillary (i.e., center-to-wall flow) is always exhibited regardless of the wettability of the channel wall, which is also indicative of the validity of the above-mentioned assertion.

Consideration of Bentonite Cake Existing on Vertical Cutoff Wall in Slug Test Analysis (벤토나이트 케익을 고려한 연직차수벽의 순간변위시험(slug test) 해석)

  • Lim, Jeehee;Nguyen, The-Bao;Lee, Dongseop;Ahn, Jaeyoon;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.6
    • /
    • pp.5-17
    • /
    • 2013
  • Slug tests can be adopted to estimate hydraulic conductivity of the slurry trench wall backfill for its abilities to reflect the in-situ performance of the construction. A comprehensive three-dimensional numerical model is developed to simulate the slug test in a slurry trench wall considering the presence of bentonite cake on the interface boundaries between the wall and the surrounding soil formation. Influential factors such as wall width (i.e., proximity of wall boundary), well deviation, vertical position of well intake section, compressibility of wall backfill, etc. are taken into account in the model. A series of simulation results are examined to evaluate the bentonite cake effect in analyzing practical slug test results in the slurry trench wall. The results show that the modified line-fitting method can be used without any correction factor for the slug test in the slurry trench wall with the presence of bentonite cake. A case study is reanalyzed with the assumption of existing bentonite cake. The results are compared with the previously reported results by the approaches assuming no bentonite cake (constant-head boundary) or upper-bound solution (no-flux boundary). The case study demonstrates the bentonite cake effect and the validity of the modified line-fitting method in the estimation of the hydraulic conductivity of the slurry wall backfill.