• Title/Summary/Keyword: Sludge thickener

Search Result 19, Processing Time 0.024 seconds

Effect of Ozone Injection on Dewaterability and Thickening of Sewage Sludge (하수 슬러지 농축 및 탈수성에 미치는 오존의 영향)

  • Hwang, Kyeoung-Sa;Kim, Moon-Ho;Bae, Yoon-Sun;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.800-808
    • /
    • 2005
  • It is required to propose an alternatives for appropriate sludge treatment owing to persistent construction of sewage treatment plant and increase of sewage sludge quantity. In order to treat sludge more efficiently, the methods which reduce the cost of sludge treatment have been studied such as sludge reduction and conditioning. Especially ozone treatment reduces solid quantity and improves separation of solid-liquid at the same time. Therefore ozone treatment have a positive effect on reduction and stabilization of sludge. So, this study applied ozone to sewage sludge and induced cell destruction of sludge. By comparing with the correlation between thickening and dewatering, and evaluating moisture content and solubilization of cake, this study verificates the effect of process improvement for ozone pre-treatment. In J-STP case, according to ozone dose solid flux increased about 12 times from $1kg/m^2{\cdot}h$ to $12kg/m^2{\cdot}h$. Also this plant were capable to shorten thickening time from 40 minutes to 6~7 minutes. Thus it is expected to reduce volume and retention time of thickener. On pH effect factor, dewatering at pH4 was more than at pH11, $3.05{\times}10^{11}$ and $3.82{\times}10^{11}(m/kg)$. But effect of pH was analogous to ozone, $2.81{\times}10^{11}(m/kg)$. The effect of pH on thickening was similar to law sludge, $0.68(kg/m^2{\cdot}h)$, and the effect of ozone injection on thickening was the biggest, $3.45(kg/m^2{\cdot}h)$. The COD solubilization rate improved from about 5 to 30%. So it is judged that we are able to utilize most solubilized sludge to another sewage treatment plants.

Settling Characteristics of Water Treatment Plant Sludges by Pretreatment Methods (정수장슬러지의 전처리에 의한 침전특성)

  • Moon, Yong-taik;Lee, Sun-ju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.6
    • /
    • pp.627-632
    • /
    • 2008
  • It is necessary to investigate methods for improvement by diagnosing sludge settling characteristics on inflow of slurry to thickener. The results of the settling tests are correlated to determine zone settling velocities at the various sludge solids concentrations. Conditioning of WTP residuals is generally done by either chemical or physical treatment. The settling test was conducted with 1m columns dosing polymer to WTP residuals at various solids concentration. The estimated results for dosing to WTP residuals for a sludge of 2,100 ~ 16,012 mg/L solids concentration were the zone settling velocities of 48.38 ~ 6.8 m/day, supernatant solid concentration of 3.2 ~ 19 mg/L and solid flux of $101.6{\sim}317.61kg/m^3{\cdot}day$. The values for non-polymer treatment were the zone settling velocities of 28.37 ~ 0.12 m/day, supernatent solid concentration of 8.5 ~ 108 mg/L and solid flux of $59.58{\sim}1.92kg/m^2{\cdot}day$. The limiting solid flux value by Yoshioka methods was $4.0kg\;TS/m^3{\cdot}day$ for Non-polymer and $228.0kg\;TS/m^3{\cdot}day$ for dosing polymer. These results are to indicate a possibility of improvement on the thickening characteristics and the quality of supernatant as increasing the settling velocities by dosing polymer to WTP residuals.

Papermill Wastewater Treatment by Indirect aerated Sebmerged Biofilter (간접포기식 침지여상에 의한 제지페수처리)

  • 원찬희
    • Journal of Environmental Science International
    • /
    • v.2 no.2
    • /
    • pp.135-144
    • /
    • 1993
  • The purpose of this experimental research was focused to improve the quality of the effluent and the yielded sludge when the papermill wastewater was treated by the indirect aerated submerged biofilter as a second treatment method of papermill wastewater. Changing the various experimental factors (Nutrient additions or not, HRT, Fh ratio, recirculation ratio, etc) with indirect aerated submerged biofilter, the results are as follows. 1) because of the microbes concentration could be sustained to 9, oho man in submerged biofilter and then the volumetric organic loads could be increased to 2.7 kg-BOD/$m^3$<\TEX>/day, the reactor volume can be reduced. 2) Because of the yield coefficient(Y) and the endogenous decay coefficient(kd) were revealed 0.4 and 0.07/d, the yielded sludge volume was reduced. 3) The concentration of the sloughed sludge in the reactor was 2.62~4.01 %, so the thickener could be omited in the papermill wastewater sludge treatment process. 4) When the operating was conducted at HRT of 4hrs, the treatment efficiencies of BOD and COD were obtained 80% and 70%. 5) The range of the theoretical recirculation ratios of this reactor was 14~26. According to those ratios, at the low loads ( BOD volumetric loads is less than 0.79 kg-BOD/$m^3$<\TEX>/day, FM ratio is less than 2.0/d) the results were fitted to the theoretical recirculation ratios (14 ~26) and at the high loads the efficiency were increased to the rise of recirculation ratios.

  • PDF

Impact of Irradiation Time on the Hydrolysis of Waste Activated Sludge by the Dielectric Heating of Microwave

  • Byun, Imgyu;Lee, Jaeho;Lim, Jisung;Lee, Jeongmin;Park, Taejoo
    • Environmental Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.83-89
    • /
    • 2014
  • The effects of initial solid concentration and microwave irradiation (MWI) time on the hydrolysis of waste activated sludge (WAS) were investigated. MWI time strongly influenced WAS hydrolysis for all initial solid concentrations of 8.20, 31.51, and 52.88 g VSS/L. For all WAS, the volatile suspended solids (VSS) solubilization degree ranged from 35.6% to 38.4% during a total MWI time of 10 min. Soluble chemical oxygen demand (SCOD) concentration increased at a rate proportional to the decrease of VSS during the MWI. However, the clearly different VSS solubilization patterns that were observed during the MWI were explained by the 2-step hydrolysis of WAS, consisting of the initial disintegration of the easily degradable part of the sludge, followed by the subsequent disintegration of the hardly degradable part of the sludge. WAS hydrolysis rates for 3 to 6 min of MWI were significantly lower than those for less than 3 min, or more than 6 min. From these results, 3 min MWI time and WAS of 31.51 g VSS/L (centrifugal thickener WAS) showed the most efficient hydrolysis of WAS at 36.0%. The profiles of total nitrogen (T-N) concentrations corresponded well to the SCOD increases in terms of the empirical formula of bacterial cell mass ($C_5H_7O_2N$). The negligible T-N increase and pH decrease during WAS hydrolysis by MWI will allow the application of this process to subsequent biological processes, such as anaerobic digestion.

Application of upflow multi-layer bioreactor (UMBR) for domestic wastewater treatment in HCMC

  • Cao, Duc Hung;Nguyen, Ngoc Han;Nguyen, Phuoc Dan;Bui, Xuan Thanh;Kwon, J.C.;Shin, H.S.;Lee, E.T.
    • Membrane and Water Treatment
    • /
    • v.3 no.2
    • /
    • pp.113-121
    • /
    • 2012
  • Up-flow multi-layer bioreactor (UMBR) is a hybrid system using dual sludge that consists of an up-flow multi-layer bioreactor as anaerobic/anoxic suspended growth microorganisms followed by an aeration tank. The UMBR acts as a primary settling tank, anaerobic/anoxic reactor, thickener which requires low energy due to mixing by up-flow stream. This study focused on using a pilot UMBR plant with capacity of 20-30 $m^3$/day for domestic wastewater in HCMC. HRTs of UMBR and aeration tank were 4.8 h and 7.2 h, respectively. The average MLSS of UMBR ranged from 10,000-13,600 mg/l SS. Internal recycle rate and sludge return were 200-300% and 150-200%, respectively. The results obtained from this study at flow rate of 20 $m^3$/day showed that removal of COD, SS, TKN, N-$NH_4$, T-N, and color were 91%, 87%, 86%, 80%, 91% and 91%, respectively.

Application of tubular membrane to thickening process as a pre-treatment of anaerobic digester (관형막을 이용한 혐기소화조의 전처리 농축공정으로써 적용가능성 연구)

  • Kang, Hee-Seok;Park, Ki-Tae;Park, Jung-Woo;Kim, Hyung Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.203-209
    • /
    • 2015
  • The purpose of this study is to estimate the applicability of a stable anaerobic digester using a separator membrane to the preprocessing thickening process. The results of the experiments showed about a 47.16% weight loss rate for the sludge under anaerobic condition, and about 41.17% under intermittent aeration condition. The concentrations of rejection water were $SCOD_{Cr}$ 25 mg/L, T-N 16.6 mg/L, and T-P 1.4 mg/L on the average under the intermittent aeration condition, which were lower than the concentrations of rejection water under an anaerobic condition. As for the factors affecting the reduction of the flux, correlation analyses of TTF, MLSS, $SCOD_{Cr}$, and $EPS_{Protein}$, $EPS_{Polysacchride}$ resulted in -0.97, -0.95, -0.84 and -0.86, -0.95, respectively, which showed that TTF had the highest correlation to the reduction of the flux. In addition, it was concluded that MLSS, $SCOD_{Cr}$ and $EPS_{Protein}$, $EPS_{Polysacchride}$ also have close correlations. The results are considered to show that, in the case of the process using a tubular membrane in the preprocessing process of an anaerobic digester, an intermittent aeration condition of the thickener considering the contamination of the membrane and load of rejection water is appropriate for the stable preprocessing process.

Odorous Gas Removal in Biofilter with Powdered Activated Carbon and Zeolite Coated Polyurethane Foam (분말활성탄 및 제올라이트 담지 폴리우레탄 담체를 이용한 바이오필터에서의 악취가스 제거)

  • Lee, Soo-Chul;Kim, Dong-Jin
    • Clean Technology
    • /
    • v.18 no.2
    • /
    • pp.209-215
    • /
    • 2012
  • The performance and removal efficiencies of a pilot scale biofilter were estimated by using ammonia and hydrogen sulfide as the odorous gases. Expanded polyurethane foam coated with powdered activated carbon and zeolite was used as a biofilm supporting medium in the biofilter. Odorous gases from the sludge thickener of a municipal wastewater treatment plant were treated in the biofilter for 10 months and the inlet ammonia and hydrogen sulfide concentrations were 0.1-1.5 and 2-20 ppmv, respectively. The removal efficiencies reached about 100% at the empty bed retention time (EBRT) of 3.6-5 seconds except for the adaptation periods. The pressure drop of the biofilter caused by the gas flow was also low that the maximum attained was 31 mm $H_2O$ during the operation. Its stability was confirmed in the long term due to the fact that the biofilter and the polyurethane medium had a minimum plugging and compression. The microbial community on the medium is critical for the performance of the biofilter especially the distribution of ammonia oxidizing bacteria (AOB) and sulfur oxidizing bacteria (SOB). The distribution of Nitrosomonas sp. (AOB) and Thiobacillus ferroxidans (SOB) was confirmed by FISH (fluorescence in situ hybridization) analysis. The longer the operation time, the more microbial population observed. Also, the medium close to the gas inlet had more microbial population than the medium at the gas outlet of the biofilter.

The Study of the Need to Remove Soluble nitrogen ($NH_3-N$) Generated from Anaerobic digestor Retrofitted in Municipal Wastewater Treatment Plants (하수처리장 에너지자립화사업에서 혐기성소화공정으로부터 용출되는 용존성질소($NH_3-N$)의 처리 필요성 연구)

  • Ahn, Seyoung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.3
    • /
    • pp.68-75
    • /
    • 2014
  • Soluble nitrogen produced from anaerobic digestor is able to have a strong influence on the effluent water quality of municipal wastewater treatment plants during a winter season in particular. The modeling results using the GPS-X simulation software shows that the soluble nitrogen concentration generated from the anaerobic digestor is 214.1 mg/L in the return flow and 6.2 mg/L in the inflow of the primary settler higher than those in nonexistence of the anaerobic digestor, respectively. In the case of using a separation process (flotation thickener) in order to treat the return flow from the sludge treatment system, the soluble nitrogen concentration in the effluent from the separation process and in the inflow of the primary setter could be 6.0 mg/L higher and 0.7 mg/L lower than those of nonexistence of the process, respectively. The modeling results propose the need of the equipments to be able to remove the soluble nitrogen ($NH_3-N$) produced from the digestor in the improvement projects of anaerobic digestor in municipal wastewater treatment plants.

Empirical Study on Applicability of Phosphorus Recovery Process in Wastewater Treatment Plant (하수처리시설에서 인 회수공정의 도입 가능성에 대한 실증적 검토)

  • Park, Na-ri;Chang, Hyang-Youn;Lim, Hyun-Man;Ahn, Kwang-Ho;Kim, Weon-Jae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.1
    • /
    • pp.40-49
    • /
    • 2017
  • In this study, we have made the annual total phosphorus (TP) mass balance diagrams for I wastewater treatment plant by utilizing the data of flow rate and TP of each process and tried to choose the optimum unit process empirically for phosphorus recovery. For the applicability evaluation, we have suggested several quantitative indices of flow rate, TP concentration, TP load and SS. Based on the analyses of TP mass balance, it became clear for reducing TP load of the wastewater treatment plant that it is efficient to recover phosphorus from the side stream in which the amount of flow rate is just 1/16, but TP concentration and load are 78 and 4.8 times larger than those of the influent of the plant. After the detailed applicability evaluation for the side stream, it could be concluded that the unit process of waste activated sludge thickener supernatant or dehydration filtrate are appropriate. Meanwhile, we did fundamental experiments utilizing the dewatering filtrate with TP concentration of 141.5 mg/L. After adjusting pH 10 and $Ca^{2+}$ concentration 250, 500, 1000 mg/L, it was stirred slowly. As a result, the $PO_4-P$ and TP removal efficiencies were above 95 percent; the results of the experiment imply the applicability of phosphorus recovery process in a wastewater treatment plant strongly.