• Title/Summary/Keyword: Sludge reuse

Search Result 83, Processing Time 0.028 seconds

Characteristics of water treatment plant sludges on raw water source (취수원별 정수장 슬러지의 물리화학적 특성)

  • Moon, Yong-Taik;Kim, Byung-Goon
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.3 s.61
    • /
    • pp.37-43
    • /
    • 2006
  • Recently, needs for reuse of sludge produced from WTP(water treatment plant) have been increased with shortage of landfill sites and difficulties of the treatment and disposal processes. Therefore, Reusing is becoming an Increasingly popular waste management alternative to divert waste from landfills. In order to research the characteristics of WTP sludges, we used the sludges of C WTP which intake the lake Dae-Cheong and the sludges of S WTP which intake Keum river, The specific surface area of C and S WTP sludges were $0.9986m^2/cc\;and\;1.874m^2/cc$, respectively. The gravity was about $2.0{\sim}2.4$ which are scope of peat or loamy clay. The major minerals of C WTP sludges were kaolinite(48.4%), muscovite(19.5%), and quartz(16.7%). Also, muscovite(31.6%), quartz(30.3%), and kaolinite(17.3%) in S WTP sludges were major minerals.

A study on the composition validity of performance indicators for public sewage treatment plant by using factor analysis (요인분석기법을 활용한 공공하수처리시설 성과평가 지표의 구성 타당성 연구)

  • Yoon, Cheon-Yeo;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.5
    • /
    • pp.583-590
    • /
    • 2015
  • Evaluation and comparison for the performance on the contracting-out became possible after the introduction of the performance indicators(PIs) in 2012 in Korea, And local governments and private companies are utilizing them as evaluation data to enhance the performance of the contracting-out. Several revisions on performance indicator were carried out by expert group on contents validity of PIs, But the review of the composition validity of PIs was not sufficient. In this study, the applicability, distinction ability and composition validity of PIs is evaluated by statistical method. From the results, Improvement of indicator is required in order to increase the interrelationship among indicators to enhance the compostion validity of indicators related with operation, sludge and water reuse.

The Study on Ozone Treatment of Wasting Activated Sludge for VFA Production and Reuse as Carbon Source for Phosphorus Release (잉여슬러지의 오존분해에 따른 VFA의 생성 및 인 방출을 위한 탄소원으로의 재이용 가능성에 관한 연구)

  • Ko, Eun-Taek;Cho, Jin-Woo;Park, Eun-Young;Ahn, Kyu-Hong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1052-1057
    • /
    • 2005
  • Recently, the ozone treatment of wasting activated sludge has become one of the effective and feasible process for the sludge reduction. The objective of this study is to investigate the availability of ozonized wasting sludge on external carbon sources 13r phosphorus release. Experiment results showed that the ozone treatment of activated sludge could produce a large amount of VFA such as acetic acid and isobutyric acid. For example, 50.24 mg/L acetic acid was produced with the ozone dose of 0.05 g $O_3/g$ SS, and 123.56 mg/L acetic acid with 0.5 g $O_3/g$ SS. The higher ozone dose was applied, the more VFA was produced from sludge reduction into a limited point. Finally, using ozonated sludge as only carbon source, the batch experiment, to measure phosphorus release rate in anaerobic condition were performed. The specific phosphorus release rates were investigated as 0.94, 1.37, 1.48, 1.68 mg P/g VSS/hr with ozone dose of 0.05, 0.1, 0.2, 0.5 g $O_3/g$ SS, respectively. Considering the degree of mineralization, VFA production, phosphorus release rate, and economical aspect, the optimal ozone dose for sludge reduction and using carbon sources ranged from 0.05 to 0.1 g $O_3/g$ SS.

Study of Trace Element and PAHs Distribution for Extensive Regulation Establishment in Raw Material of Compost on Organic Resource (퇴비원료기준 확대설정을 위한 유기성자원의 미량원소 및 PAHs 분포 연구)

  • Lim, Dong-Kyu;Lee, Seung-Hwan;Kwon, Soon Ik;Seong, Ki-Seog;Lee, Jeong-Taek;Song, Beom-Heon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.6
    • /
    • pp.339-344
    • /
    • 2006
  • A lot of organic wastes have been produced from diverse industries, they must be tested by the regulation of fertilizer control act if reuse the organic wastes for agricultural utilization. The regulation has had only two criteria; the content of organic matter and 8 heavy metals. This study was conducted to evaluation trace element (boron, cobalt, molybdenum, and selenium) and distribution of organic compounds with different classification for complement the regulation in 16 organic waste materials(62 samples) collected from different regions and industries. Contents of boron(leather industry sludge, $154.2mg\;kg^{-1}$; food company sludge, $57.1mg\;kg^{-1}$), cobalt(industrial area sewage sludge, $95.2mg\;kg^{-1}$; metropolitan sewage sludge, $22.9mg\;kg^{-1}$), molybdenum(metropolitan sewage sludge, $40.1mg\;kg^{-1}$; food company sludge, $16.8mg\;kg^{-1}$), selenium (fiber industry sludge, $28.1mg\;kg^{-1}$; leather industry sludge, $16.9mg\;kg^{-1}$; food company sludge, $15.9mg\;kg^{-1}$) were highest compare to the other organic wastes. Total PAHs contents were the highest in paper-mill manufacture($3,462ug\;kg^{-1}$), and among the 16 PAHs, naphthalene, phenanthrene, pyrene, fluoroanthene, Anthracene and acenaphthene were detected more clearly than others in all kinds of organic resources.

Trends of Technology Development through Investigation and Analysis of Domestic Patent Related to Wastewater Treatment Technology including Membrane, Sludge Treatment and Advanced Treatment Technology and Equipment (분리막 및 슬러지 처리와 고도처리 기술·장비를 포함한 하·폐수 처리기술의 특허 조사·분석을 통한 기술개발 동향)

  • Yoo, Ho Sik;Kim, Ji Tae
    • Membrane Journal
    • /
    • v.27 no.5
    • /
    • pp.375-388
    • /
    • 2017
  • Wastewater treatment (WWT) technology has been developing from simple pollutant treatment to energy and resource-saving advanced technology, and various technologies combined with IT and BT are developed to minimize the amount of pollutant and toxic substance discharge to the public water areas and to improve operational efficiency. To examine the development trend of domestic wastewater treatment technology, the registered patent technologies were surveyed, classified and analyzed by year and sector. This paper considers the status of patent registration related to WWT from 2010.1 to 2017.5 in terms of the number of specific technical areas, and the trends are analyzed based on the 10 categorization field such as biological and physicochemical treatment process, equipment and device, material, sludge treatment, membrane, process control and 42 specific technical areas. A total of 3,356 patents have been registered since 2010, and the number of patents has been decreasing since the peak at 2013 and maintains 3~400 per year. The total number of patents has not yet been less than other countries, but the number of patents of more advanced technologies, which can lead the global market, such as process monitoring, new concept processing and equipment technologies is still insufficient compared to developed countries.

Treatment of Organic Wastes and Reuse of Bio-energy from the Anaerobic Digestion - Thermophilic Oxic Precess (혐기성 소화-고온 호기법에 의한 유기성폐기물의 처리와 생성열의 재활용 검토)

  • Yang, Jae-Kyung;Choi, Kyung-Min
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.1
    • /
    • pp.79-89
    • /
    • 2001
  • Anaerobic Digestion - Thermophilic Oxic Process(ADTOP) has been known to be one way reducing and composting of organic wastes without draining or forming excess sludge. It could be completely performed by the evaporation of water using the bio-energy from the microbial degradation of organic. In the present study the complete treatment of Chinese restaurant wastes was conducted and utility of bio-energy produced from the ADTOP was estimated. Base on results, it could be concluded as follows; 1) chinese restaurant wastes could be completely treated using the TOP without draining or excess sludge. Maximum volumetric loading rate was determined as $55.0kg-garbage/m^3$. Input water was almostly evaporated and 90.5% of carboneous organic wastes was conversed to carbondioxide. 2)The optimum volumetric loading rate which is acceptable to maintain over $55^{\circ}C$ in the anaerobic digester was determined as $45kg-garbage/m^3{\cdot}d$. 3) The optimum HRT was at least over 10 days in order to maintain about $50^{\circ}C$ in the anaerobic digester using bio-energy produced from TOP. Therefore the utilization of bio-energy produced from TOP could be used in the process which had long HRT such as the anaerobic digestion. 4) The efficiency of anaerobic digester rate were over 90% by the ADTOP under the organic loading rate of $1.1kg-COD/m^3{\cdot}d$, 50kg-Chinese restaurant garbage and $250{\ell}/m^3{\cdot}min$ of the aeration rate.

  • PDF

A Study on the Characteristics and Utilization of Ash from Sewage Sludge Incinerator (하수(下水)슬러지 소각재의 특성(特性) 평가(評價) 및 재활용(再活用)을 위한 기초연구(基礎硏究))

  • Lee, Hwa-Young
    • Resources Recycling
    • /
    • v.17 no.3
    • /
    • pp.3-9
    • /
    • 2008
  • The measurement of physicochemical properties and chemical composition of SSA(sewage sludge ash) has been carried out and the preparation of lightweight material has also been performed using SSA for reuse as building or construction materials. For this aim, lightweight material has been prepared by forming the mixture of SSA, lightweight filler and inorganic binder followed by calcination at elevated temperature and characterized in terms of density and compressive strength. The pH of fly ash was found to be slightly alkaline, pH 8.69, due to the addition of caustic soda in order to neutralize the acidic gas while the pH of bottom ash was 6.48 Heavy metal leachability based on the standard leach test was also found to be below the detection limit for Cd, Cu, Pb, As and Cr of SSA. As far as the compressive strength of lightweight material was concerned, the compressive strength of lightweight material using fly ash was higher than that of lightweight material using bottom ash.

Water Reuse of Sewage Discharge Water Using Fertilizer Drawn Forward Osmosis - Evaluating the Performance of Draw Solution - (비료 유도용액의 정삼투를 이용한 하수처리수의 재이용 - 유도용액의 성능 평가 -)

  • Kim, Seung-Geon;Lee, Ho-Won
    • Membrane Journal
    • /
    • v.26 no.2
    • /
    • pp.108-115
    • /
    • 2016
  • This study is to evaluate the performance of draw solutions in the water reuse of sewage discharge water using fertilizer drawn forward osmosis. Feed water used in all experiments was the effluent from secondary sedimentation tank in activated sludge process. Considering osmotic pressure, solubility, and pH, $NH_4H_2PO_4$, KCl, $KNO_3$, $NH_4Cl$, $(NH_4)_2HPO_4$, $NH_4NO_3$, $NH_4HCO_3$, and $KHCO_3$ were screened from a comprehensive lists of fertilizer. Their performances were evaluated in terms of water permeate flux and reverse solute flux. KCl showed the highest average water flux followed by $NH_4Cl$, $NH_4NO_3$, $KNO_3$, $KHCO_3$, $NH_4HCO_3$, $NH_4H_2PO_4$, and $(NH_4)_2HPO_4$. Using KCl as draw solution, the average water permeate flux was 13.49 LMH. There was no big difference in osmotic pressure between the effluent from secondary sedimentation tank and deionized water. $NH_4H_2PO_4$ showed the lowest reverse solute flux followed by $NH_4Cl$, $(NH_4)_2HPO_4$, $KNO_3$, $NH_4HCO_3$, and $NH_4NO_3$. Using $NH_4H_2PO_4$ as draw solution, the reverse solute flux was $4.96{\times}10^{-3}mmol/m^2{\cdot}sec$.

A study about treatment for water treatment residual sludge using submerged membrane system (침지식 막여과 공정을 이용한 정수장 배출수 처리에 관한 연구)

  • Kim, Jun-Hyun;Lee, Ju-Hyung;Moon, Baek-Su;Kwak, Young-Ju;Jang, Jung Woo;Kim, Jinho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.2
    • /
    • pp.181-193
    • /
    • 2014
  • Various treatment system for residuals have applied to save water resources, but most of them were not be satisfied with legal standard consistently. In this study, submerged membrane treatment system was operated to treat water treatment plant residuals and operation parameters was evaluated. Result of this experiment, high concentration organic matters contributed to high increase Transmembrane pressure(TMP) of membrane system(from 0.05 bar to 0.35 bar). And backwash process was effective to stabilize membrane system operation. After Cleaning-In-Place(CIP), permeability was recovered about 100 % from first operation condition. Inorganic matters (Fe, Mn, Al, Ca, Mg) were not effective membrane filtration performance. The quality of residual treatment was satisfied with drinking water quality standard and a treated water from that system was suitable for water reuse.

A Fundamental Study on the Application of Cast for Removal of VOCs Produced in the Oil-contaminated Soil (유류오염 토양에서 발생되는 VOCs 제거를 위한 분변토의 활용 가능성에 관한 기초연구)

  • Son, Hee-Jeong;Chun, Mi-Hee;Kim, Chul
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.5
    • /
    • pp.456-461
    • /
    • 2007
  • This study was carried out two point view that reuse of sludge and adsorption of benzene, toluene and o-xylene of VOCs in cast, carbonized cast and activated carbon. The cation exchange capacity of cast and carbonized cast were 59.2, 112 meq/100g, respectively. The specific surface were 560, $800m^2/g$, respectively. The average removal rates of benzene by 50g cast of 50% hydrous cast, anhydrous cast, carbonized cast, activated carbon were 15.0, 41.2, 88.2, 99.4% in 60min of retention time. The average removal efficiency of toluene by 50 g cast of 50% hydrous cast, anhydrous cast, carbonized cast, activated carbon were 12.5, 34.2, 88.2, 99.5% in 60 min of retention time. The average removal rates of o-xylene 50 g cast of 50% hydrous cast, anhydrous cast, carbonized cast, activated carbon were 8.8, 28.5, 84.8, 98.1% in 60min of retention time. The adsorption efficiency of test absorbent was in order of Activated Carbon > Carbonized Cast > Cast.