• Title/Summary/Keyword: Sludge Volume Index

Search Result 41, Processing Time 0.018 seconds

Biological Treatment of Livestock Wastewater using Aerobic Granular Sludge (호기성 그래뉼 슬러지를 이용한 축산폐수의 생물학적 처리에 관한 연구)

  • Hyun-Gu Kim;Dae-Hee Ahn
    • Journal of Environmental Science International
    • /
    • v.32 no.7
    • /
    • pp.483-492
    • /
    • 2023
  • In this study, the treatment of livestock wastewater using an aerobic granular sludge based sequencing batch reactor was investigated. The reactor operation was carried out by general injection and split injection methods. The average removal efficiency of organic matter after the adaptation period was 71.5 and 87.4%, respectively. Some untreated organic matter was attributed to recalcitrant organic matter. The average removal efficiency of total nitrogen was 65.6 and 88.4%, respectively. These results indicate that the denitrification reaction by split injection was carried out smoothly. As for the solids, the ratio of aerobic granular sludge/mixed liquor suspended solid can be determined as the main factor of the process operation, and the ratio increased gradually and finally reached 86.0%. Correspondingly, the sludge volume index (SVI) was also improved, reaching 54 mL/g at the end of operation, and it is believed that the application of a short settling time contributed to the improvement of settleability.

Effect of Sludge Characteristics on the Thickening of Bulking Sludge using DAF (Dissolved Air Flotation) (슬러지의 성상이 DAF(Dissolved Air Flotation)를 이용한 팽화 슬러지 농축에 미치는 영향)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.97-103
    • /
    • 2006
  • Excess sludge treatment and disposal currently represent a rising challenge for domestic or wastewater treatment plants due to economic, environmental and regulation factors. Conventional gravity sedimentation process has been widely used in sludge thickening. The operation method of the process is very simple, but the process requires long detention time for sludge thickening, uses polymers, and shows low sludge thickening efficiency. To solve the problems, we studied on DAF (Dissolved Air Flotation) system. We use bulking sludge of a paper manufacturing plant. The effects of parameters such as SVI (Sludge Volume Index), storage time, initial concentration and wet density of excess sludge were examined. The results showed that the more SVI was low, the more sludge was thickened. As storage time goes by, SVI was increased and thickening performance was deteriorated. In order to improve flotation performance at high concentration, high recycling ratio and pressure did not increase the concentration due to thickening limitation. The addition of 0.8 g/L of loess was increased flotation efficiency of 1.41 times.

THE MONITORING OF AEROBIC FLOC-LIKE SLUDGE INFLUENCED BY CALCIUM IONS

  • Yoon, Young H.;Park, Jae-Ro;Kim, In-S.
    • Environmental Engineering Research
    • /
    • v.11 no.3
    • /
    • pp.127-133
    • /
    • 2006
  • Aerobic floc-like sludge was formed in a batch reactor and the effect of cations on the formation of aerobic floc-like sludge was studied. In order to enhance the formation (rate) of aerobic floc-like sludge, cations such as $K^+$, $Na^+$, $Ca^{2+}$, and $Mg^{2+}$ were added to the seed sludge. It was found that $Ca^{2+}$ had positive effect on the formation of floc-like sludge, as measured by sludge volume index (SVI) for settle ability. The formation of floc-like sludge was confirmed by the microscopic observation after DAPI staining. The scattered forms of sludge samples at the initial stage became aggregated to form floes after $Ca^{2+}$ addition. To ensure the functions of sludge floes in a treatment plant, the gradient of ionic species around the surfaces of floc-like sludge was monitored by ion selective microelectrodes for ${NH_4}^+,\;{NO_3}^-$, and pH. The effective concentration of $Ca^{2+}$ ion to form floc-like sludge was determined to be 750 mg/L (0.15 mg $Ca^{2+}/mg$ MLSS). Under the effective $Ca^{2+}$ condition, the SVI value was the lowest and large distribution of nitrifying bacteria at the outer surface was observed in the aerobic floc-like sludge. From the results, it was found that the calcium ion functioned as an agent for the formation of aerobic floc-like sludge, resulting in the enhanced nitrification.

Effects of Aerobic/non-aerobic Starvation Periods on the Physical Characteristics of Activated Sludge and Organic Removal Efficiency in SBR (폭기/비폭기 상태의 기근기간이 활성슬러지의 물리적 특성 및 유기물 제거에 미치는 영향)

  • Oh, Hye-Ran;Kim, Sang-Soo;Moon, Byung-Hyun;Yoon, Cho-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.2
    • /
    • pp.343-348
    • /
    • 2010
  • The objective of this study was to investigate the effects of starvation periods with aerobic or non-aerobic conditions on the organic removal efficiencies and physical characteristics of activated sludge for treating saline and non-saline wastewater. During the experiment, MLSS, MLVSS, sludge volume index (SVI), floc size and fractal dimension, $COD_{Mn}$ removal efficiencies were monitored. The reductions of MLSS, MLVSS and SVI with maintaining the sludge under a non-aerobic condition during starvation periods were smaller than those under a aerobic condition. Floc size, fractal dimension and $COD_{Mn}$ removal efficiencies were less decreased under non-aerobic condition than under aerobic condition. And SVI were strongly correlated with floc size and fractal dimension. Consequently, the result showed that maintaining the activated sludge under non-aerobic starvation conditions was better strategy than that under aerobic starvation conditions as it adapted and resisted to starvation.

Effects of Sludge SVI and Chemical Conditioning on Activated Sludge Flotation Thickening (슬러지 SVI와 화학적 개량이 슬러지부상농축에 미치는 영향)

  • Lee, Ki Yong;Kim, Shin Jo;Kwon, Oh Sang;Yeom, Ick Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.2
    • /
    • pp.349-355
    • /
    • 2010
  • Electroflotation (EF) was conducted for activated sludge thickening to investigate the effects of sludge SVI (sludge volume index) and chemical conditioning. Return sludge samples were used for the experiment, which were collected from municipal wastewater treatment plants. The performance of sludge thickening was significantly dependent on sludge SVI. For the sludges with SVI values in a range from 50 to about 150 mL/g, the maximum float content decreased rapidly from 8.4 to 3.5% and flotation compressibility followed the same pattern. In cases of sludges with SVI higher than 150 mL/g, those results showed low content levels without large changes. Gas/solids ratio tended to increase with an increase in SVI. When polyelectrolyte was added into sludges for the conditioning, compressibility increased up to 75% and gas/solids ratio was reduced up to about 35% under the condition of microbubble production rate of 530 mL/h, however, there was no consistent effect of chemical conditioning on the maximum float solids content; some cases were positive but the others negative. It was expected that the optimum dose of electrolyte depends on sludge SVI and an excessive chemical dose causes a performance deterioration of flotation thickening.

Fuzzy Expert System for Bulking Prediction and Mitigation in the Activeated Sludge Process

  • Nam, Sung-Woo;Kim, Jung-Hwan-;Sung, U-Kyung;Lee, Kwang-Soon-
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.1102-1105
    • /
    • 1993
  • A fuzzy expert system for prediction and mitigation of sludge bulking was developed for an activated sludge process which treats waste water from a food industry. The developed system is able not only to infer the degree of progress of sludge bulking but also to generate remedial operation guides which may be sent to the local controllers as remote set points. One of the important consequences through this study is the BI (Bulking Index) inferred by the bulking prediction expert system was found to have a close correlation with the SVI (Sludge Volume Index) which is a practical measure of degree of bulking but needs tedious chores for its measurement.

  • PDF

The effect of zeolite addition on floc in activated sludge process (제올라이트 주입이 활성슬러지 플럭에 미치는 영향)

  • Lee, Hyung Sool;Park, se Jin;Yoon, Tae Il
    • Clean Technology
    • /
    • v.7 no.1
    • /
    • pp.35-42
    • /
    • 2001
  • This study was performed to evaluate the effect of zeolite addition on biofloc in aictvated sludge process. Two units were compared each other, in which one was operated as control unit (CU) and the other was managed by adding zeolite into aeration basin to sustain 4,000 mg/l (ZU). It was observed that flocs of both units were enduringly increased in medium size by extending SRT (Solid Retention Time), although their effect size of ZU was smaller than theirs of CU. Zeolite application excessively improved sludge settling property and ZU presented sludge settling velocity of 3.4 to 11 m/h regardless of SRT variation. The sludge volume index (SVI) was in the range of 50 and 108 ml/g. Conversely, the sludge settling velocity of CU seriously depended on SRT increase, and sludge sedimentation was not achieved at a 40 days of SRT due to Sphaerotilus appeared predominantly in reactor.

  • PDF

Chlorine Inhibition on the Denitrifying Activity of Activated Sludge Microorganisms (활성슬러지 미생물의 탈질 활성에 대한 염소의 저해)

  • Choi, Jin-Taek;Nam, Se-Yong
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.338-343
    • /
    • 2007
  • Chlorine inhibition on the denitrifing activity of activated sludge treating dairy wastewater was investigated in this study. Filamentous bulking was caused artificially by a sudden load of feed and monitored by measuring sludge volume index. In cases of the activated sludge and bulking sludge which were contacted with chlorine as $7.5\;mgCl_2/gVSS/day$ for bulking control, the decreases of specific denitrification of $32.2{\sim}40.4%\;and\;43.5{\sim}46.5%$ were shown in comparison to the control group which was not reacted with chlorine, respectively. In continuous operation, it was observed that the removal efficiency of total nitrogen was more susceptible to chlorine than the removal efficiency of total phosphorus.

Changes of physico-chemical properties of the activated sludges with anaerobic storage time (혐기화 시간에 따른 활성슬러지의 물리ㆍ화학적 특성변화)

  • 이창한;나영수;김도한;이송우;송승구
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.339-346
    • /
    • 2002
  • Physico-chemical properties of the activated sludges(Suyoung and Changlim treatment plant), such as SVI(sludge volume index), absorbance, specific surface area, and specific resistance using Buchener funnel test were investigated with changing anaerobic storage time. This experimental condition was found that it was possible to estimate a linear relationship between their parameters such as specific surface area specific resistance, and sludge volume index(SVI). The specific surface area and the specific resistance to filtration of the activated sludges of Suyoung and Changlim treatment plant were found as 123.6~136.6$m^2$/gDS and 41.5~44.9$m^2$/gDS(dry solid), and 1.09$\times$10$^{14}$ ~5.48$\times$10$_{14}$ m/kg and 1.05$\times$10$^{14}$ ~2.48$\times$10$^{14}$ m/kg, respectively. The results gave a good linear relationship between the specific surface area and the specific resistance, r=2.25$\times$10$^{12}$ s-8.10$\times$10$^{13}$ ($R^2$=0.8885) at Suyoung treatment plant and r=1.26$\times$10$^{13}$ s-4.75$\times$10$^{14}$ ($R^2$=0.8756) at Changlim treatment plant.

Development of SV30 Detection Algorithm and Turbidity Assumption Model using Image Analysis Method (이미지 분석기법을 이용한 SV30 자동감지방법 및 탁도 추정 모델 개발)

  • Choi, Soo-Jung;Kim, Ye-Jin;Yoom, Hoon-Sik;Cha, Jae-Hwan;Choi, Jae-Hoon;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.168-174
    • /
    • 2008
  • Diagnosis on setteability based on human operator's experimental knowledge, which could be established by long term operation, is a limit factor to construction of automation control system in wastewater treatment plant. On-line SVI(Sludge Volume Index) analyzer was developed which can measure SV30 automatically by image capture and image analysis method. In this paper, information got by settling process was studied using On-line SVI analyzer for better operation & management of WWTPs. First, SV30 detection algorithm was developed using image capture and image analysis for settling test and it showed that automatic detection is feasible even if deflocculation and bulking was occurred. Second, turbidity assessment model was developed using image analysis.