Browse > Article
http://dx.doi.org/10.5322/JES.2002.11.4.339

Changes of physico-chemical properties of the activated sludges with anaerobic storage time  

이창한 (부산대학교 화학공학과)
나영수 (부산대학교 화학공학과)
김도한 (부산대학교 화학공학과)
이송우 (부산대학교 화학공학과)
송승구 (부산대학교 화학공학과)
Publication Information
Journal of Environmental Science International / v.11, no.4, 2002 , pp. 339-346 More about this Journal
Abstract
Physico-chemical properties of the activated sludges(Suyoung and Changlim treatment plant), such as SVI(sludge volume index), absorbance, specific surface area, and specific resistance using Buchener funnel test were investigated with changing anaerobic storage time. This experimental condition was found that it was possible to estimate a linear relationship between their parameters such as specific surface area specific resistance, and sludge volume index(SVI). The specific surface area and the specific resistance to filtration of the activated sludges of Suyoung and Changlim treatment plant were found as 123.6~136.6$m^2$/gDS and 41.5~44.9$m^2$/gDS(dry solid), and 1.09$\times$10$^{14}$ ~5.48$\times$10$_{14}$ m/kg and 1.05$\times$10$^{14}$ ~2.48$\times$10$^{14}$ m/kg, respectively. The results gave a good linear relationship between the specific surface area and the specific resistance, r=2.25$\times$10$^{12}$ s-8.10$\times$10$^{13}$ ($R^2$=0.8885) at Suyoung treatment plant and r=1.26$\times$10$^{13}$ s-4.75$\times$10$^{14}$ ($R^2$=0.8756) at Changlim treatment plant.
Keywords
Anaerobic storage time; Specific surface area; Specific resistance; Activated sludge;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Allen, T., 1990, Particle Size Measurement, Chapman & Hall, 597-610pp
2 SORENSEN, B. L. et al., 1996, Filtration Characterisation and Specific Surface Area Measurement of Activated Sludge by Rhodamine B Adsortion, Wat. Res., 30(1), 115-121   DOI   ScienceOn
3 한태성 외 2 명, 1998, 산성염료폐수 처리에서 염료물성에 따른 응집 탈색효율에 관한 연구, 화학공학, 36(1), 20-26
4 井伊谷鋼, 1995, 분체공학개론, 일본분체공학연구회, 9pp
5 Smith, P. G., and P. Coackley, 1984, Diffusivity, Tortuosity and Pore Structure of Activated Sludge, Wat. Res., 18(1), pp. 117-122   DOI   ScienceOn
6 Standard Methods, 1995, APHA, A WWA .WEF, 19th edition
7 이창한, 1998, 흡광도를 이용한 활성슬러지의 농도 측정, 부산대학교 공학석사학위 논문
8 Andreadakis, A. D., 1993, Physical and Chemica1 Properties of Activated Sludge Floc, Wat. Res., 27(12), 1707-1714   DOI   ScienceOn
9 Smith, P. G., and P. Coackley, 1983, A method for Determining Specific Surface Area of Activated Sludge by Dye Adsorption, Wat. Res., 17(5), 595-598   DOI   ScienceOn
10 Sezgin, M., 1982, Variation of Sludge Volume Index with Activated Sludge Charateristics, Wat. Res., 16, 83-88   DOI   ScienceOn
11 윤준섭, 2001, 응집현상이 슬러지 탈수에 미치는 영향, 부산대학교 공학석사학위 논문
12 Bruus, J. H. et. al., 1993, Anarobic Storage of Activated sludge : Effects on Conditioning and Dewatering Performance, Wat. Sci. Tech., 28(1), 109-116