• 제목/요약/키워드: Sludge Reduction

검색결과 314건 처리시간 0.02초

Reduction Behavior of Self-Reducing Pellets of Chromite and Si Sludge with and without Carbon

  • Jung, Woo-Gwang;Hossain, Sakib Tanvir;Kim, Jong-Ho;Chang, Young-Chul
    • 한국재료학회지
    • /
    • 제29권10호
    • /
    • pp.592-602
    • /
    • 2019
  • Feasibility is investigated for reduction of chromium ore by Si sludge with mixed silicothermic and carbothermic reaction. The reduction behavior of chromium ore using Si sludge is investigated precisely to determine the effects of carbon addition, reaction time, and reaction temperature. The pellets are dropped into the furnace after temperature stabilized. As the amount of C addition increases, the amounts of CO and $CO_2$ gas generation increase. After the dropping of the pellets, the pellets are heated and the reaction starts at about 1,573 K or higher. The pellets maintain their shape until 10 min after the drop, and then melted. As the holding time increased, the size of the reduced metal particles increased. The chromium ore is rapidly reduced by the Si sludge, and the slag penetrated into the chromium ore and reduction progressed inside. As the reduction temperature increased, the reaction initiation time is shortened and the reaction fraction of the reduction reaction increased. As the reaction temperature increased, agglomeration of reduced ferrochrome metal is promoted.

PVA-gel 미생물 고정화 담체를 이용한 고도하수처리 및 슬러지 감량화 운전조건 연구 (A Study on the Operation Condition for Carbon-Nitrogen Removal in Wastewater and Sludge Reduction using PVA-gel Immobilized Microorganism)

  • 이진숙;박형완;남덕현;박철휘;정인호;유영관
    • 상하수도학회지
    • /
    • 제20권6호
    • /
    • pp.875-883
    • /
    • 2006
  • The carbon and nitrogen removal process using PVA-gel (Polyvinyl Alcohol) immobilized microorganisms was studied. The process has been operated under diverse process conditions for 12 months. The process consists of denitrification with internal recycle of 300%, nitrification, aerobic digestion reactors and settling tank. Nitrificatoin and nitrogen removal efficiency according to gel packing ratio and temperature were studied. Yield for Heterotrophs ($Y_H$), decay coefficient for Heterotrophs($b_H$) in aerobic digestion reactor were determined to seize sludge reduction mechanism and compared with typical data of activated sludge process. Then SRT in aerobic digestion reactor was determined on an experimental basis and sludge reduction efficiency was calculated. The process was implemented successfully with sludge reduction efficiency of 92.0~98.5% on a basis of biomass.

SAPS의 탄소원 공급을 위한 유기물 연구

  • 이지은;고주인;김선준;유상희
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.231-234
    • /
    • 2004
  • The experiments on some organic materials used in SAPS are carried out for the better sulfate reduction efficiency and the longer lifetime. Organic materials include spent mushroom compost, sewage sludge, oak chip compost and the combination of there. Reactors with mushroom compost, sewage sludge, the mixture of mushroom compost and sewage sludge, and the mixture of mushroom compost and oak chip compost maintained pH higher than 6.0. Reactors with mushroom compost, the mixture of mushroom compost and sewage sludge, and the mixture of mushroom compost and oak chip compost maintained reduction condition. Reactors with sewage sludge, oak chip compost and the mixture of sewage and oak chip compost produced COD less than 2,000ppm. Reactors with sewage and the mixture of mushroom compost, sewage sludge, oak chip compost showed about 60% of sulfate removal ratios.

  • PDF

오존을 이용한 하수슬러지의 감량화와 안정화 (Reduction and Stabilization of Sewage Sludge by Ozonation)

  • 이창근;황은주;강성재;빈정인;이병헌
    • 한국물환경학회지
    • /
    • 제20권3호
    • /
    • pp.290-295
    • /
    • 2004
  • In this study, ozone was adopted for the reduction and stabilization of waste sludge from the municipal sewage treatment plant. The waste sludge used in the experiments was primary sludge, excess sludge and a mixture of the two. The sludge cells and flocs were disrupted by ozonation resulting in the reduction of TSS and VSS concentrations. In the case of the primary sludge with a concentration of 20 gTS/L, the TSS and VSS concentrations were reduced 28%, 33% and the TCOD concentration was reduced 20% respectively. The consumption of ozone was $0.18gO_3/gSS$. In the case of the excess sludge with a concentration of 7.5 gTS/L, the TSS and VSS concentrations were reduced 37%, 41%, and the TCOD concentration was reduced 19% respectively. The consumption of ozone was $0.33gO_3/gSS$. In the case of the mixed sludge of 9.3 gTS/L, the TSS and VSS concentrations were reduced by 45%, 53%, and the TCOD was reduced 26% respectively. The desirable consumption of ozone was $0.27gO_3/gSS$. As ozonation proceeded, the level of SCOD increased due to the release of intracellular materials. However TCOD was reduced due to mineralization resulting from the transformation of organic materials to inorganic materials.

폐슬러지 감량화 및 재활용을 위한 오존 처리시 하수슬러지내의 미생물 군집구조의 변화 (Change of Microbial Community on Ozonation of Sewage Sludge to Reduce Excess Sludge Production)

  • 홍준석;임병란;안규홍;맹승규
    • 상하수도학회지
    • /
    • 제18권1호
    • /
    • pp.59-65
    • /
    • 2004
  • The change of the microbial community structure in excess sludge of different sewage treatment plants by ozone treatment was investigated by quinone profiles. The resulting ozone dosage ranged from 0.1 to $0.4gO_3/gTS$. In terms of overall sludge reduction, more than 50% reduction of the total sludge mass could be achieved by ozone treatment at $0.4gO_3/gTS$. Quinone concentration and type in sludge of different treatment plants were remarkably decreases with increasing ozone dose. Ubiquinones(UQs)-8, -10 and MK-8 were still remained in the ozonized sludge at $0.4gO_3/gTS$. The results of this study showed that the remaining microorganisms belong to UQs-8, -10 and MK-8 were difficult to destruct cell membrane or wall by ozonation. Fecal Streptococci and Salmonella were not detected at ozone dose of $0.2gO_3/gTS$, but Fecal Coliform was not detected at ozone dose of $0.4gO_3/gTS$.

전기펜톤공정을 이용한 석유화학공장 폐활성슬러지의 감량화 가능성 평가 (A study on reduction of excess sludge in activated sludge system from a petrochemical plant using electro fenton process)

  • 정종민;김경일;심나타리아;박철희;이상협
    • 상하수도학회지
    • /
    • 제23권5호
    • /
    • pp.669-678
    • /
    • 2009
  • The reduction of excess activated sludge from petrochemical plant was investigated by the electro fenton (E-Fenton) process using electrogenerated hydroxyl radicals which lead to mineralization of activated sludge to $CO_2$, water and inorganic ions. Factors affecting the disintegration efficiency of excess activated sludge in E-Fenton process were examined in terms of five criteria: pH, $H_2O_2/Fe^{2+}$ molar ratio, current density, initial MLSS (mixed liquid suspended solids) concentration, $H_2O_2$ feeding mode. TSS total suspended solid and $TCOD_{cr}$ reduction rate increased with the increasing $H_2O_2/Fe^{2+}$ molar ratio and current density until 42 and $6.7 mA/cm^2$, respectively but further increase of $H_2O_2/Fe^{2+}$ molar ratio and current density would reduce the reduction rate. On the other hand, as expected, increasing pH and initial MLSS concentration of activated sludge decreas TSS and $TCOD_{cr}$ reduction rate. The E-Fenton process was gradually increased during first 30 minutes and then linearly proceed till 120 minutes. The optimal E-Fenton condition showed TSS reduction rate of 62~63% and $TCOD_{cr}$ (total chemical oxygen demand) reduction rate of 55~56%. Molar ratio $H_2O_2/Fe^{2+} = 42$ was determined as optimal E-Fenton condition with initial $Fe^{2+}$ dose of 5.4 mM and current density of $6.7{\sim}13.3 mA/cm^2$, initial MLSS of 7,600 mg/L and pH 2 were chosen as the most efficient E-Fenton condition.

음식물쓰레기의 호기성 퇴비화에 있어서 볏짚과 하수슬러지케이크가 미치는 영향에 관한 비교 연구 (Comparison of Effects of Rice Straw and Sewage Sludge Cake on Aerobic Composting of Food Wastes)

  • 박석환
    • 한국환경보건학회지
    • /
    • 제29권1호
    • /
    • pp.43-50
    • /
    • 2003
  • This study was performed to compare the effects of rice straw and towage sludge cake as bulking materials on temperature, pH, weight and volume reduction, porosity, C/N ratio, salinity, and conductivity in aerobic composting of food wastes. Volume ratios of food wastes to rice straw in reactor control, RS-1, RS-2, RS-3 and RS-4 were 4:0, 4:1, 4:2, 4:3 and 4:4, respectively. Weight ratios of food wastes to sewage sludge rake in reactor control, SL-1, SL-2, SL-3 and SL-4 were 4:0, 4:1, 4:2, 4:3 and 4:4, respectively. Reactors were operated for 24 days with 1 hour stirring by 1 rpm and 2 hours aeration per day. The values of pH of food waters, rice straw and sewage sludge cake were 4.39, 7.40 and 5.79, respectively. The lowering of the volume ratio of food wastes to rice straw resulted in the high reaction temperature and the fast weight and volume reduction rates. The lowering of the weight ratio of food wastes to sewage sludge cake resulted in the slow weight and volume reduction rates. C/N ratio in control was larger than that in rice straw containing reactors, and that in rice straw containing reactors was larger than that in sewage sludge cake containing reactors. Salinity and conductivity in reactors were condensed and increased by reaction days.

Effects of ultrasound coupled with potassium permanganate pre-treatment of sludge on aerobic digestion

  • Demir, Ozlem
    • Advances in environmental research
    • /
    • 제5권4호
    • /
    • pp.251-262
    • /
    • 2016
  • The biodegradability and decomposition efficiencies increase with the pre-treatment of sludge in a digestion process. In this study, the feasibility of ultrasound coupled with potassium permanganate oxidation as a disintegration method and digestibility of aerobic reactor fed with disintegrated sludge with ultrasound coupled potassium permanganate were investigated. The first stage of the study focused on determining the optimum condition for ultrasonic pre-treatment for achieving better destruction efficiency of sludge. The second part of the study, the aerobic digestibility of sludge disintegrated with ultrasound and potassium permanganate oxidation alone and combined were examined comparatively. The results showed that when 20 min of ultrasonic pre-treatment applied, the specific energy output was 49384 kJ/kgTS with disintegration degree of 58.84%. During the operation of aerobic digester, VS/TS ratios of digesters fed with disintegrated sludge decreased indicating that disintegration methods could obviously enhance aerobic digestion performance. The highest reduction in volatile solids was 75% in the digester fed with ultrasound+potassium permanganate disintegrated sludge at the end of the operation compared to digester fed with raw sludge. Total Nitrogen (TN) and Total Phosphorus (TP) levels in sludge supernatant increased with this combined method significantly. Besides, it promoted the production of ${\bullet}OH$, thus enhancing the release of Carbon (C), Nitrogen (N) and Phosphorus (P) from the sludge. Disintegration with all methods used in this study could not improve Capillary Suction Time (CST) reduction in disintegrated digesters during the operation. The results demonstrated that the combined ultrasound treatment and potassium permanganate oxidation method improves the biodegradability compared to control reactor or their single application.

하수 일차슬러지의 세정산발효 특성에 대한 Microwave 전처리의 영향 (Effects of Microwave Irradiation for Elutriated Acid Fermentation of Sewage Primary Sludge)

  • 권구호;이원식;민경석
    • 한국물환경학회지
    • /
    • 제23권4호
    • /
    • pp.498-503
    • /
    • 2007
  • The performance of elutriated acid fermentation to evaluate the effects of microwave irradiation and pH control as pretreatment was investigated. The MW pH 7 reactor which was used the pretreated primary sludge as microwave irradiation was operated at pH 7 and $35^{\circ}C$. The EAF pH 9 reactor was operated at pH 9 and $35^{\circ}C$ without pretreatment. The SCOD and VFAs production rate were 0.17 gSeOD/gVSrem. and 0.27 gVFAs as COD/gVSrem. in MW pH 7 reactor, 0.16 gSCOD/gVSrem. and 0.24 gVFAs as COD/gVSrem. in EAF pH 9 reactor, respectively. VS and Volume reduction were 54% and 48% in MW pH 7 reactor, 54.6% and 36% in EAF pH 9 reactor, respectively. A comparison of the microwave irradiation and controlled pH in elutriated acid fermentation showed that the former is more efficient in SCOD and VFAs production and it rises to slightly higher reduction in the volume of the sludge. In addition, E. coli. was not detected in the wasting sludge of MW pH 7 reactor. Based on the results, microwave irradiation appeared to be one of the viable options for generating class A sludge. According to the batch tests, sequencing batch test which was used the pretreated primary sludge as microwave was performed at pH 7 and $35^{\circ}C$, SCOD production was 0.16 gSCOD/gVSrem., VS reduction and volume reduction were 64% and 63%, respectively.

저온 플라즈마와 활성슬러지 복합 공정에서 체류시간 변화가 악취 저감 및 슬러지 가용화에 미치는 영향 (Effects of Retention Time on the Simultaneous of Odor Removal and Sludge Solubilization Using a Non-Thermal Plasma System)

  • 남궁형규;황현정;송지현
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.815-824
    • /
    • 2011
  • In this study, a non-thermal plasma system was employed to simultaneously remove odorous compounds and organic sludge. The system consisted of two reactors; the first one was the non-thermal plasma reactor where ozone was produced by the plasma reaction and the ozone oxidized hydrogen sulfide, the model odorous compound, and then the ozone-laden gas stream was introduced to the second reactor where wasted sludge was disintegrated and solubilized by ozone oxidation. In this study, the gas retention time (GRT) and the hydraulic retention time (HRT) were changed in the two-reactor system, and the effects of GRT and HRT on reduction efficiencies of odor and sludge were determined. As the GRT increased, the ozone concentration increased resulting in an increasing efficiency of hydrogen sulfide removal. However, the overall ozone loading rate to the second sludge reactor was the same at any GRT, which resulted in an insignificant change in sludge reduction rate. When HRTs in the sludge reactor were 1, 2, 4 hours, the sludge reduction rates were approximately 30% during the four-hour operation, while the rate increased to 70% at the HRT of 6 hours. Nevertheless, at HRTs greater than 4 hours, the solubilization efficiency was not proportionally increased with increasing specific input energy, indicating that an appropriate sludge retention time needs to be applied to achieve effective solubilization efficiencies at a minimal power consumption for the non-thermal plasma reaction.