• 제목/요약/키워드: Sludge Oil

검색결과 111건 처리시간 0.023초

Isolation of a Lipolytic and Proteolytic Bacillus licheniformis from Refinery Oily Sludge and Optimization of Culture Conditions for Production of the Enzymes

  • Devi, Sashi Prava;Jha, Dhruva Kumar
    • Microbiology and Biotechnology Letters
    • /
    • 제48권4호
    • /
    • pp.515-524
    • /
    • 2020
  • With the increasing demand for enzymes in industrial applications there is a growing need to easily produce industrially important microbial enzymes. This study was carried out to screen the indigenous refinery bacterial isolates for their production of two industrially important enzymes i.e. lipase and protease. A total of 15 bacterial strains were isolated using Soil Extract Agar media from the oil-contaminated environment and one was shown to produce high quality lipase and protease enzymes. The culture conditions (culture duration, temperature, source of nitrogen, carbon, and pH) were optimized to produce the optimum amount of both the lipase (37.6 ± 0.2 Uml-1) and the protease (41 ± 0.4 Uml-1) from this isolate. Productivity of both enzymes was shown to be maximized at pH 7.5 in a medium containing yeast extract and peptone as nitrogen sources and sucrose and galactose as carbon sources when incubated at 35 ± 1℃ for 48 h. Bacterial strain SAB06 was identified as Bacillus licheniformis (MT250345) based on biochemical, morphological, and molecular characteristics. Further studies are required to evaluate and optimize the purification and characterization of these enzymes before they can be recommended for industrial or environmental applications.

Characteristics of organic pollutants in discharged industrial waste in Korea - Focuse on metallic and plastic manufacturing processes and wastewater treatment plants - (국내 사업장 폐기물 중 유기오염물질의 배출특성 연구 - 금속과 플라스틱 제조공정 및 폐수처리시설 중심으로 -)

  • Yeon, Jin-Mo;Kang, Young-Yeul;Kim, Woo-Il;Shin, Sun-Kyoung;Jeong, Seong-Kyeong;Cho, Yoon-A;Kim, Na;Kim, Min-Sun
    • Analytical Science and Technology
    • /
    • 제25권6호
    • /
    • pp.421-428
    • /
    • 2012
  • In this study, PCDD/PCDFs, PAHs and PCBs in wastes from metal, plastic and wastewater treatment facilities were analyzed. The concentrations of PCDD/PCDFs ranged from 7.37~432.20 ng-TEQ/kg in fly ash, 0.51~855.01 ng-TEQ/kg in incinerated ash and 0.37~385.81 ng-TEQ/kg in dust. Dioxin content was lower, compared to data in foreign countries. PAHs concentration was in the range of 0.0075~2.9225 mg/kg for process sludge and 0.0035~1.6716 mg/kg for wastewater sludge, which satisfied all of the two standards (Nap, Ant, B(a)F:4/0.8, Phen, B(a)A:5/1, Flt:10/2.5, B(a)P:4.5/0.9) of the Marine Environment Management Act. PAHs concentration in process sludge and wastewater sludge were slightly lower than those abroad. According to the analysis of seven types of PCBs (in comparison with the first standard, 0.15 mg/kg), concentration was found in the range of 0.0~0.65 mg/kg, while PCB-52, PCB-101, PCB-138, PCB-153 and PCB-180 isomers were detected in excessive value in some machine oil and hydraulic fluid.

Integrated Eco-Engineering Design for Sustainable Management of Fecal Sludge and Domestic Wastewater

  • Koottatep, Thammarat;Polprasert, Chongrak;Laugesen, Carsten H.
    • Journal of Wetlands Research
    • /
    • 제9권1호
    • /
    • pp.69-78
    • /
    • 2007
  • Constructed wetlands and other aquatic systems have been successfully used for waste and wastewater treatment in either temperate or tropical regions. To treat waste or wastewater in a sustainable manner, the integrated eco-engineering designs are explained in this paper with 2 case studies: (i) a combination of vertical-flow constructed wetland (CW) with plant irrigation systemfor fecal sludge management and (ii) integrated CW units with landscaping at full-scale application for domestic wastewater treatment. The pilot-scale study of fecal sludge management employed 3 vertical-flow CW units, each with a dimension of $5{\times}5{\times}0.65m$ (width ${\times}$ length ${\times}$ media depth) and planted with cattails (Typha augustifolia). At the solid loading rate of 250 kg total solids (TS)/$m^2.yr$ and a 6-day percolate impoundment, the CW system could achieve chemical oxygen demand (COD), TS and total Kjeldahl nitrogen (TKN) removal efficiencies in the range of 80 - 96%. The accumulated sludge layers of about 80 - 90 cm was found at the CW bed surface after operating the CW units for 7 years, but no clogging problem has been observed. The CW percolate was applied to 16 irrigation Sunflower plant (Helianthus annuus) plots, each with a dimension of $4.5{\times}4.5m$ ($width{\times}length$). In the study, the CW percolate were fed to the treatment plots at the application rate of 7.5 mm/day but the percolate was mixed with tap water at different ratio of 20%, 80% and 100%. Based on a 1-year data of 3-crop plantation were experimented, the contents of Zn, Mn and Cu in soil of the experimental plots were found to increase with increasing in CW percolate ratios. The highest plant biomass yield and oil content of 1,000 kg/ha and 35%, respectively, were obtained from the plots fed with 20% or 50% of the CW percolate, whereas no accumulation of heavy metals in the plant tissues (i.e. leaves, stems and flowers) of the sunflower is found. In addition to the pilot-scale and field experiments, a case study of the integrated CW systems for wastewater treatment at Phi Phi Island (a Tsunami-hit area), Krabi province, Thailand is illustrated. The $5,200-m^2$ CW systems on Phi Phi Island are not only for treatment of $400m^3/day$ wastewater from hotels, households or other domestic activities, but also incorporating public consultation in the design processes, resulting in introducing the aesthetic landscaping as well as reusing of the treated effluent for irrigating green areas on the Island.

  • PDF

Effect of Initial Concentration on Pilot-Scale Composting of Diesel-Contaminated Soil (초기농도가 파일럿 규모의 디젤 오염토양 콤포스팅 처리에 미치는 영향)

  • 임재량;박준석;황의영;남궁완
    • Journal of Environmental Health Sciences
    • /
    • 제28권5호
    • /
    • pp.35-41
    • /
    • 2002
  • This study was conducted to evaluate the effect of initial concentration on pilot-scale composting of diesel-con-laminated soil. Sandy soi] was used in this study. Target contaminant, diesel oil, was spiked. at about 10,000, 25,000, and 50,000 mg TPH/kg of dry roil. Mit ratio of soil to sludge was 1:0.5 as wet weight basis. Removal efficiencies for initial concentrations of 12,966,23,894 and 51,042 mg TPH/kg were 90, 93 and 54%, respectively, during 33 days of composting. Normal alkanes in TPH ranged from 15 to 22% in initial soils. Volatilization of individual normal alkane in 1,999 mg n-alkanes/kgwas completed within 4 days, while n-alkane compounds of Cl1-Cl4 in 5,270 and 9,836 mg n-alkanes/kg were volatilized continuously during 33 days of composing operation. The first order degradation rate con-stants for 12,966, 23,894, and 51,042 mg TPH/kg were 0.058, 0.076, and 0.022/day, and those for 1,997 5,270, and 9,836 mg n-alkanes/kg were 0.093, 0.100, and 0.019/day, respectively. Considering TPH removal rate, $CO_2$porduction rate, and dehydrogenase activity, the concentration of 51,042 mg TPH/kg inhibited biodegradation of diesel-composting.

Treatment of cutting-oily wastewater by electrocoagulation-flotation (ECF) process: Modeling approach

  • Chawaloesphosiya, Nattawin;Mongkolnauwarat, Jittrapa;Prommajun, Chayanin;Wongwailikhit, Kritchart;Painmanakul, Pisut
    • Environmental Engineering Research
    • /
    • 제20권4호
    • /
    • pp.392-396
    • /
    • 2015
  • This work aims to investigate the oily wastewater treatment by the electrocoagulation-flotation (ECF) and propose a mathematical model for the efficiency prediction. Cutting oil was used to prepare the synthetic oily wastewater with submicron droplet sizes. The chemical coagulation by aluminium sulfate was firstly tested following by the electrocoagulation-flotation with aluminium electrodes. Both processes gave the effective treatment performance with the efficiencies higher than 90%. However, the ECF consumed less aluminium dosage as well as produced less sludge, which were its advantage on the chemical coagulation. The performance of the ECF was found to be affected by the current density, oil concentration, and reaction time according to the analysis by the design of experiment (DOE). Finally, the prediction model was proposed by two approaches, including linear and logarithm function. The latter model gave more accuracy prediction results in terms of treatment efficiency and duration in the lag and stable stages.

A Fundamental Study on the Application of Cast for Removal of VOCs Produced in the Oil-contaminated Soil (유류오염 토양에서 발생되는 VOCs 제거를 위한 분변토의 활용 가능성에 관한 기초연구)

  • Son, Hee-Jeong;Chun, Mi-Hee;Kim, Chul
    • Journal of Environmental Health Sciences
    • /
    • 제33권5호
    • /
    • pp.456-461
    • /
    • 2007
  • This study was carried out two point view that reuse of sludge and adsorption of benzene, toluene and o-xylene of VOCs in cast, carbonized cast and activated carbon. The cation exchange capacity of cast and carbonized cast were 59.2, 112 meq/100g, respectively. The specific surface were 560, $800m^2/g$, respectively. The average removal rates of benzene by 50g cast of 50% hydrous cast, anhydrous cast, carbonized cast, activated carbon were 15.0, 41.2, 88.2, 99.4% in 60min of retention time. The average removal efficiency of toluene by 50 g cast of 50% hydrous cast, anhydrous cast, carbonized cast, activated carbon were 12.5, 34.2, 88.2, 99.5% in 60 min of retention time. The average removal rates of o-xylene 50 g cast of 50% hydrous cast, anhydrous cast, carbonized cast, activated carbon were 8.8, 28.5, 84.8, 98.1% in 60min of retention time. The adsorption efficiency of test absorbent was in order of Activated Carbon > Carbonized Cast > Cast.

A Study on the Combustion Characteristics of Atomized Bunker oil by Homogenizer (균질기에 의해 미립화된 벙커유의 연소 특성 연구)

  • Han, Sanggoo;Choi, Jung-Sik;Yoon, Seok Hoon;Park, R.S.;Kim, D.H.;Song, Y.M.;Choi, Jae-Hyuk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 한국마린엔지니어링학회 2012년도 전기공동학술대회 논문집
    • /
    • pp.188-190
    • /
    • 2012
  • 고전단력을 갖도록 개발된 Homogenizer를 이용해 IFO 380cst Bunker-C 시료를 미립화 및 균질화하는 전처리를 시행하였다. 전처리된 시료의 슬러지 저감효과를 확인하기위하여 유청정기(oil purifier)를 이용하였고, 실험결과 약 13% 가량 슬러지 생성이 감소하는 것을 확인하였다. 또한, 전처리 후 유청정기를 통과한 시료를 실제 보일러 시스템에서 연소시켜 연소 성능 특성을 확인한 결과 CO가 감소하는 경향을 확인하였다. 선박운항비용 분석을 통해 U.L.C.C 기준 연 8,800만원 가량의 연료비 절감 효과가 있을 것으로 추정된다.

  • PDF

A Study on the Washing Effect Biodegradation of Natural Fat Soap - On Based Biodegradation - (계면활성제 혼합 천연지방산유지 고형 비누의 세척성 및 생분해성 연구 - 생분해성을 중심으로 -)

  • Lee, Bong-Yeon;Ryu, Duck-Hwan;Lee, Tae-Gwan
    • Fashion & Textile Research Journal
    • /
    • 제5권3호
    • /
    • pp.289-294
    • /
    • 2003
  • The purpose of the study was to get the valuable data for developing the new natural fat soaps which have an excellent biodegradation performance. Thus, natural fat soaps mixed with the two types of detergents (AOS and LAS) on the various concentrations were made and the biodegradation of the samples were analysed by Dissolved Oxygen method using active sludge. Also, the results were compared with the commercial synthetic detergents and market soaps. The results from the study were the followings: 1. The plant fat soap and the wasted oil soap with the concentration of 5 mg/l and 15 mg/l had an excellent biodegradation rather than animal fat soap. 2. There was little difference among samples with the concentration of 5 mg/l, but there was much difference among them with the concentration of 15 mg/l. 3. The periods for consuming oxygen of wasted oil soap mixed AOS and LAS was the fastest.

New Technology Development for Production of Alternative Fuel Oil from Thermal Degradation of Plastic Waste (폐플라스틱의 열분해에 의한 대체 오일 생산의 신기술 개발)

  • Lee Kyong-Hwan;Roh Nam-Sun;Shin Dae-Hyun
    • Resources Recycling
    • /
    • 제15권1호
    • /
    • pp.37-45
    • /
    • 2006
  • For treating a huge amount of plastic waste with the environment problem, pyrolysis of plastic waste into alternative fuel oil is one or important issue in recycling methods. This study was introduced over the trend or generation of plastic waste, in Korea pyrolysis technology in domestic and foreign countries, basic technology in pyrolysis process and new technology of pyrolysis developed in KIER (Korea Institute of Energy research). The characteristics of process developed in KIER are the continuous loading treatment or mixed plastic waste with an automatic control system, the minimization of wax production by circulation pyrolysis system in non-catalytic reactor, the reuse of gas produced and the oil recovery from sludge generated in pyrolysis plant, which have greatly the advantage economically and environmetally. The experiment result data in 300 ton/yr pilot plant showed about $81\;wt\%$ liquid yield for 3 days continuous reaction time, and also the boiling point distribution of light oil (LO) and heavy oil (HO) produced in distillation tower was a little higher than that of commercial gasoline and diesel, respectively.

New Technology Development for Production of Alternative Fuel Oil from Thermal Degradation of Plastic Waste (폐플라스틱의 열분해에 의한 대체 오일 생산의 신기술 개발)

  • Lee, Kyong-Hwan;Roh, Nam-Sun;Shin, Dae-Hyun
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 한국자원리싸이클링학회 2005년도 추계정기총회 및 제26회 학술발표대회 고분자리싸이클링기술 특별심포지엄
    • /
    • pp.34-46
    • /
    • 2005
  • For treating a huge amount of plastic waste with the environment problem, pyrolysis of plastic waste into alternative fuel oil is one of important issue in recycling methods. This study was introduced over the trend of generation of plastic waste, pyrolysis technology in domestic and foreign countries, basic technology in pyrolysis process and new technology of pyrolysis developed in KIER (Korea Institute of Energy Research). The characteristics of process developed in KIER are the continuous loading treatment of mixed plastic waste with an automatic control system, the minimization of wax production by circulation pyrolysis system in non-catalytic reactor, the reuse of gas produced and the oil recovery from sludge generated in pyrolysis plant, which have greatly the advantage economically and environmetally. The experiment result data in 300 ton/yr pilot plant showed about 81 wt% liquid yield for 3 days continuous reaction time, and also the boiling point distribution of light oil (LO) and heavy oil (HO) produced in distillation tower was a little higher than that of commercial gasoline and diesel, respectively.

  • PDF