• 제목/요약/키워드: Slow-wave factor

검색결과 21건 처리시간 0.032초

수면과 시토카인 (Sleep and Cytokine)

  • 신재공
    • 수면정신생리
    • /
    • 제12권2호
    • /
    • pp.87-92
    • /
    • 2005
  • Cytokines are the main regulatory molecules of not only immune system but also sleep system. Research on the role of cytokines on sleep has greatly been expanding since the first report of sleep-promoting effects of interleukin-1, the first cytokine molecule. Interleukin-1 and tumor necrosis factor are most widely studied among various cytokines. Studies over about twenty years demonstrate that most cytokines promote sleep but several cytokines inhibit sleep. Slow wave sleep is the main part that cytokines have effects on. Besides normal sleep physiology, cytokines have more major roles on pathophysiology of various sleep disorders. Obstructive sleep apnea is the representative sleep disorder that shows how deeply cytokines are involved in their pathophysiologic mechanisms of sleep disorders. Though there are many controversial issues on this topic, more mysterious part of normal sleep physiology and sleep disorders will be revealed in near future through thorough studies on sleep and cytokine.

  • PDF

The effect of typhoon translation speed and landfall angle on the maximum surge height along the coastline

  • Qian, Xiaojuan;Son, Sangyoung
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.153-153
    • /
    • 2021
  • Storm Storm event is one of major issues in South Korea due to devastating damage at its landfall. A series of statistical study on the historical typhoon records consistently insist that the typhoon translation speed (TS) is on slowdown trend annually, and thus provides an urgent topic in assessing the extreme storm surge under future climate change. Even though TS has been regarded as a principal contributor in storm surge dynamics, only a few studies have considered its impact on the storm surge. The landfall angle (LA), another key physical factor of storm surge also needs to be further investigated along with TS. This study aims to elucidate the interaction mechanism among TS, LA, coastal geometry, and storm surge synthetically by performing a series of simulations on the idealized geometries using Delft3D FM. In the simulation, various typhoons are set up according to different combinations of TS and LA, while their trajectories are assumed to be straight with the constant wind speed and the central pressure. Then, typhoons are subjected to make landfall over a set of idealized geometries that have different depth profiles and layouts (i.e., open coasts or bays). The simulation results show that: (i) For the open coasts, the maximum surge height (MSH) increases with increasing TS. (ii) For the constant bed level, a typhoon normal to the coastline resulted in peak MSH due to the lowest effect of the coastal wave. (iii) For the continental shelf with different widths, the slow-moving typhoon will generate the peak MSH around a small LA as the shelf width becomes narrow. (iv) For the bay, MSH enlarges with the ratio of L/E (the length of main-bay axis /gate size) dropping, while the greatest MSH is at L/E=1. These findings suggest that a fast-moving typhoon perpendicular to the coastline over a broad continental shelf will likely generate the extreme storm surge hazard in the future, as well as the slow-moving typhoon will make an acute landfall over a narrow continental shelf.

  • PDF

쾌적제어를 위한 수면 초기 실내온도 변동이 인체 생리에 미치는 영향 (The Effect of Indoor Temperature Change on Human Physiology for Comfort Control during Sleep Early Stage)

  • 신효준;김동규;정석권;금종수;김형철
    • 동력기계공학회지
    • /
    • 제11권3호
    • /
    • pp.29-34
    • /
    • 2007
  • Existent researches about indoor thermal environment have been focused on to seek human's comfort in daytime. Also researches about thermal comfort during the sleeping time that is important for resting and recharging to modern people have been seldom existed. At present, as global warming phenomenon is being continued, most people are going through inconvenience by sultriness during the sleeping hours in sweltering summer night. Therefore we need another control method of an air conditioner to keep human's thermal comfort. Ambient temperature is a common factor of the environment, but analysis of its effect on human body physiology is still unknown. The effect of ambient temperature on human sleep has been increasingly studied in the last decade. This research investigated about optimal indoor temperature to maintain proper skin temperature and comfortable sleep when indoor air is cooled by an air conditioner in sweltering summer night.

  • PDF

연조직-골 모사 팬텀에서 피질골 두께에 대한 유도초음파 위상속도의 의존성 (Dependencies of phase velocities of ultrasonic guided waves on cortical thickness in soft tissue-bone mimicking phantoms)

  • 이강일
    • 한국음향학회지
    • /
    • 제40권6호
    • /
    • pp.587-592
    • /
    • 2021
  • 노화 및 골다공증으로 인해 긴 뼈에서 발생하는 피질골의 두께 변화는 골절의 위험인자로 알려져 있다. 본 연구는 200 kHz의 중심주파수 및 12.7 mm의 직경을 갖는 한 쌍의 트랜스듀서와 함께 축방향 전파법을 이용하여 윗면이 2 mm 두께의 실리콘 고무층으로 덮인(1 mm부터 4 mm까지의 두께를 갖는) 아크릴판으로 제작된 7개의 연조직-골 모사 팬텀에서 피질골 두께에 대한 유도초음파 위상속도의 의존성을 고찰하였다. 모든 연조직-골 모사 팬텀에서 서로 다른 속도를 갖는 First Arriving Signal(FAS) 및 Slow Guided Wave(SGW)가 전파하는 것으로 일관되게 관찰되었다. FAS의 위상속도는 피질골 두께가 증가함에 따라 약간 감소하는 반면 SGW의 위상속도는 피질골 두께가 증가함에 따라 크게 감소하는 것으로 나타났다. FAS 및 SGW의 위상속도는 각각 실리콘 고무층을 갖지 않는 아크릴판에서 전파하는 S0 및 A0 램 모드의 위상속도와 거의 일치하는 것으로 나타났으며, 이는 아크릴판의 윗면을 덮고 있는 연조직 모사 물질(2 mm 두께의 실리콘 고무층)의 존재가 위상속도 측정에 큰 영향을 미치지 않는다는 것을 의미한다.

질량-스프링 모델을 이용한 해수 중 오탁방지막 거동해석 (Behavioral Analysis of Silt Protectors in Seawater Using the Mass-Spring Model)

  • 이춘우;김옥삼;신현출;황두진
    • 해양환경안전학회지
    • /
    • 제23권2호
    • /
    • pp.194-199
    • /
    • 2017
  • 오탁방지막이 바닷물 속에 설치되어 있을 때 조류와 파도가 변할 때 움직임과 앵커 파주력을 초과하는 유체력이 작용할 경우의 이동 메카니즘을 질량-스프링법으로 해석하였다. 설치 위치는 전남 진도군 임회면 굴포리 동령개 포구 해역이다. 앵커의 파주력을 초과하는 장력은 0.05 m/s에서는 318초 후에 도달하였고, 0.15 m/s에서는 77초, 0.25 m/s에서는 43초, 0.3 m/s에서는 37초 후에 앵커가 움직이기 시작하여, 조류 속도가 0.01 m/s로 증가함에 따라서 평균 11.2 초 정도, 앵커 이동시작 시간이 단축되고 있었다. 조류만 작용할 때와 파랑이 추가될 때의 차이점은 유속이 느릴 경우, 앵커의 이동이 시작되는 시간의 차이가 7.6 % 정도 발생하였으나, 유속이 빠른 경우는 4.3 % 미만으로 큰 차이가 없이 앵커 이동이 시작되는 것을 알 수 있었다. 조류 속도가 0.13 m/s를 초과하고 파도의 방향이 일치하면 주변의 해저 구조물과의 충돌로 인해 오탁방지막 성능이 정상적으로 작동하지 않을 수 있으니, 오탁방지막을 바다에 설치할 때 해수의 흐름 상황 등을 질량-스프링 방법으로 면밀하게 검토해야 한다.

Effects of Single Treatment of Anti-Dementia Drugs on Sleep-Wake Patterns in Rats

  • Jung, Ji-Young;Roh, Moo-Taek;Ko, Kyung-Kyun;Jang, Hwan-Soo;Lee, Seong-Ryong;Ha, Jeoung-Hee;Jang, Il-Sung;Lee, Ho-Won;Lee, Maan-Gee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제16권4호
    • /
    • pp.231-236
    • /
    • 2012
  • We studied the effects of acetylcholinesterase inhibitors, donepezil and galantamine, and an N-methyl-D-aspartate (NMDA) receptor blocker, memantine, on sleep-wake architecture in rats. Screw electrodes were chronically implanted into the frontal and parietal cortex for the electroencephalography (EEG). EEG was recorded with a bio-potential amplifier for 8 h from 09:30 to 17:30. Vibration was recorded to monitor animal activity with a vibration measuring device. Sleep-wake states such as wake (W), slow-wave sleep (S) and paradoxical or rapid eye movement sleep (P), were scored every 10 sec by an experimenter. We measured mean episode duration and number of episode to determine which factor sleep disturbance was attributed to. Donepezil and memantine showed a significant increase in total W duration and decreases in total S and P duration and delta activity. Memantine showed increases in sleep latency and motor activity. Changes of S and P duration in memantine were attributed from changes of mean episode duration. Galantamine had little effect on sleep architecture. From these results, it is showed that galantamine may be an anti-dementia drug that does not cause sleep disturbances and memantine may be a drug that causes severe sleep disturbance.

생체전기자율반응 측정기와 한방진단시스템 및 맥진기 검사 해석의 상관성 연구 (A Study about Correlations between the Interpretations of Autonomic Bioelectric Response Recorder (ABR-2000) and Diagnosis System of Oriental Medicine (DSOM) / 3D Blood Pressure Pulse Analyzer (3D-MAC))

  • 옥진유;이인선
    • 대한한방부인과학회지
    • /
    • 제31권2호
    • /
    • pp.31-48
    • /
    • 2018
  • Objectives: This study was performed to observe the correlations between the results of ABR-2000 and DSOM / 3D-MAC to evaluate the feasibility of ABR-2000 as a oriental medical diagnostic criteria. Methods: We studied 547 women visiting ${\bigcirc}{\bigcirc}$ hospital from December 2012 to June 2015. The subjects were categorized in two groups, 'Hypotonia' and 'Non-Hypotonia' by the result of ABR-2000 and assessed the result of DSOM, 3D-MAC for each group. The differences of pulse wave factors by group also studied. Results: 1. There was no significant difference between two groups about the output frequency of pathogenic factors in DSOM while the result showed the higher correlation in Hypotonia group in terms of the companion tendency of pathogenic factors and syndromes formed by the combination of pathogenic factors. 2. The pulse waves of Hypotonia group were mostly slow, weak, tense and stiff than Non-Hypotonia group. Conclusions: 1. In Hypotonia group, yin deficiency (陰虛) factor was frequently accompanied and consumption (虛損) of various organs based on the yin deficiency (陰虛) was observed. It means chronic and severe condition of exhaustion syndrome (虛勞). 2. The result of 3D-MAC also means pathological feature of yin syndrome (陰 證) and consumption (虛損). Besides, lower scores of Body Surface Area (BSA), body weight, and Body Mass Index (BMI) were associated with body weakness (體瘦), a symptom of exhaustion syndrome (虛勞).

맴돌이형 결함접지구조를 이용한 마이크로파 증폭기의 소형화 방법 (A Technique for Reducing the Size of Microwave Amplifiers using Spiral-Shaped Defected Ground Structure)

  • 임종식;정용채;안달;남상욱
    • 한국전자파학회논문지
    • /
    • 제14권9호
    • /
    • pp.904-911
    • /
    • 2003
  • 맴돌이형 결함접지구조(spiral-shaped defected ground structure, Spiral-DGS)를 이용하여 증폭기의 크기를 줄이는 새로운 방법이 제시되었다. 접지면에 Spiral-DGS를 지니는 마이크로스트립 선로는 동일한 물리적 길이의 표준형 마이크로스트립 선로에 비하여 더 큰 전파지연상수와 전기적 길이를 갖는다. 또한 대역저지여파기와 같이 특정한 대역에서 우수한 차단 특성을 갖는다. 이 차단 대역이 증폭기의 하모닉을 차단하는데 사용된다. 입,출력 정합회로 내에서 Spiral-DGS가 삽입된 선로의 길이는 원래의 선로 길이의 39 %와 44 %에 불과하다. 그러나 소형화된 증폭기의 측정된 S-파라미터는 원증폭기의 S-파라미터와 잘 일치한다. 소형화된 증폭기의 측정된 2차 하모닉의 크기는 원증폭기보다 최소한 10 dB 이상 더 작다. 3차 하모닉 제거를 위한 Spiral-DGS가 같은 방법으로 증폭기 소형화에 적용되는데, 25 dB 이상의 3차 하모닉 차단 효과를 보인다.

비행시차와 일중리듬 (Jet Lag and Circadian Rhythms)

  • 김인
    • 수면정신생리
    • /
    • 제4권1호
    • /
    • pp.57-65
    • /
    • 1997
  • 누구나 시차가 큰 여행을 할 때 몇일 간 비행시차증이라고 불리우는 증상을 경험하게 된다. 비행시차증은 수면박탈, 비행요인, 지연요인의 복합적인 원인으로 인해 생기는 하나의 증상군이라고 말할 수 있다. 특히 빠른 시차변화로 인한 생리적 지연효과(Jet lag)는 외적 비동조화, 내적 비동조화, 그리고 수면상실의 결과를 낳는다. 인간의 수면을 조절하는 기전에 있어 일중체계가 중요하다. 즉, 평균적인 수면-각성주기는 중심체온의 주기와 내적 비동조화가 일어나더라도 수면경향, 졸리움, 자발적 수면 기간, 그리고 렘수면 경향은 중심체온의 내인성 일중주기에 따라 통제된다. 수면의 구성요소중에서 서파수면은 중심체온의 주기보다는 수면시작시간에 따라 나타나며 이전에 깨어있었던 기간이 길수록 강력하게 나타난다. 따라서 수면은 일중체계와 항상성 기전의 상호작용으로 조절된다. 비행시차 후에 변화되는 수면양상을 이해하는데 있어 일중 체계 이외에 도항상성 기전을 고려하여야한다. 수면에 대한 일중리듬체계의 영향과 수면의 항상성 과정이 비행시차후 도착지에서의 수면양상을 설 명할 수 있을 것이다. 도착지에서의 적응은 통과한 시간대 수, 여행 방향, 일주기 리듬의 부조화에 적응 할 수 있는 개인별 능력에 따라 다르다. 도착지의 시간적 단서에 빨리 노출되어 일중체계의 위상반응곡선에 의한 재동조화를 촉진시키고 수면의 항상성 과정을 고려하여 도착지의 밤 이전까지 충분히 깨어 있는 것이 Jet Lag를 극복하고 적응하는 지름길일 것이다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF