• Title/Summary/Keyword: Slow design

Search Result 490, Processing Time 0.026 seconds

A Design of 3 dB Power Divider using Slow-wave Characteristic (Slow-wave 특성을 이용한 3 dB 전력 분배기 설계)

  • Kim, Chul-Soo;Park, Jun-Seok;Ahn, Dal;Kim, Geun-young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.5
    • /
    • pp.694-700
    • /
    • 1999
  • In this paper, we studied the design of power divider using the slow-wave effect of Photonic Bandgap structure, which is etched on the ground plane. The proposed PBG structure can provides the changing of the characteristic impedance of the transmission line and the group delay velocity characteristic. Therefore we can make wider width than the width of conventional transmission line and decrease the length of transmission line. We presented the application for power divider using the characteristic impedance and electrical length extracted from scattering parameter. As adding proposed defect units, the effect of defect is studied. The experimental results show good agreements with the simulated results.

  • PDF

The effect of different cooling rates and coping thicknesses on the failure load of zirconia-ceramic crowns after fatigue loading

  • Tang, Yu Lung;Kim, Jee-Hwan;Shim, June-Sung;Kim, Sunjai
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.152-158
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the influence of different coping thicknesses and veneer ceramic cooling rates on the failure load of zirconia-ceramic crowns. MATERIALS AND METHODS. Zirconia copings of two different thicknesses (0.5 mm or 1.5 mm; n=20 each) were fabricated from scanning 40 identical abutment models using a dental computer-aided design and computer-aided manufacturing system. Zirconia-ceramic crowns were completed by veneering feldspathic ceramics under different cooling rates (conventional or slow, n=20 each), resulting in 4 different groups (CONV05, SLOW05, CONV15, SLOW15; n=10 per group). Each crown was cemented on the abutment. 300,000 cycles of a 50-N load and thermocycling were applied on the crown, and then, a monotonic load was applied on each crown until failure. The mean failure loads were evaluated with two-way analysis of variance (P=.05). RESULTS. No cohesive or adhesive failure was observed after fatigue loading with thermocycling. Among the 4 groups, SLOW15 group (slow cooling and 1.5 mm chipping thickness) resulted in a significantly greater mean failure load than the other groups (P<.001). Coping fractures were only observed in SLOW15 group. CONCLUSION. The failure load of zirconia-ceramic crowns was significantly influenced by cooling rate as well as coping thickness. Under conventional cooling conditions, the mean failure load was not influenced by the coping thickness; however, under slow cooling conditions, the mean failure load was significantly influenced by the coping thickness.

Feasibility Study of Intermittent Slow Sand Filtration for Agricultural Reuse of Reclaimed Water (농업적 용수재이용을 위한 간헐분사 완속모래여과 하수재처리 효율 평가)

  • 윤춘경;정광욱;함종화;황하선
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.5
    • /
    • pp.160-170
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of intermittent slow sand filtration for agricultural reuse of reclaimed water. The effluent of biofilter for 16-unit apartment was used as influent to the slow sand filtration system at 0.6 $m^3$/day loading rate using 15 seconds spray in every 10 minutes on the about 1 $m^2$ surface area and 0.5 m depth. The influent concentrations of total coliform (TC), fecal coliform (FC) and E. coli were in the range of 10.000 MPN/100 mL. and they were reduced to less than 1,000 MPN/100 mL after filtration with average of 320, 270, and 154 MPN/100 mL, respectively, showing over 95 % removal. Turbidity and SS were improved effectively and their average concentration was reduced to 0.8 NTU and 1.7 mg/L, respectively, and removal rate was about 50 %. Average BOD and COD concentrations were also reduced substantially to 2.6 and 25.8 mg/L with about 55 and 21 % removal rate, respectively. Nutrients removal was relatively low and removal rate for T-N and T-P was low however, remaining nutrients might be beneficial and less concerned in case of agricultural reuse. The concentration of biofilter effluent used in this experiment was in the range of secondary treatment effluent but slightly stronger than the one from existing wastewater treatment plants (WWTPs). Therefore, intermittent slow sand filtration might be also applicable to the effluent from WWTPs as long as its agricultural reuse is available. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, the intermittent slow sand filtration was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water. This paper is a preliminary result from pilot study and further investigations are recommended on the optimum design parameters before full scale application.

Psycho-physicological Effects of the Dynamic lighting on VDT workers (조명환경의 변동이 작업자에게 미치는 심리.생리적 영향)

  • 엄기수;박근상
    • Proceedings of the ESK Conference
    • /
    • 1998.04a
    • /
    • pp.194-199
    • /
    • 1998
  • The purpose of this study is conducted to evaluate the psycho-physiological effects of the dynamic lighting on VDT workers and to establish the dynamic lighting design guides. The main experimental factors are changes of illuminance. There were five conditions including 1) ripid change, 2) slow change at 300lx .approx. 500lx, 3) a static illuminance level at 300lx, and 4) rapid chante, 5) slow change at 200lx .approx. 300lx. The ranges of change were set typical illuminance level for the simple visual task requirement and reasonable to a VDT task ; 200-300-500lx. The psycho-physiological measurements used were EEG, R-R interval, CFF, near point accommodation, feeling perceived fatigue, and work performance. Analysis of psycho-physiological factors shows that higher illumination level conditions are more affirmative effects than lower on VDT workers under 500lx except for the results of feeling perceived fatigue. And about the speed of changes of illuminance level. The conditions of slow change were better than the others in terms of the work performance as well as psycho-physiological results.

  • PDF

Fabrication and Identification of Marx Generator for the Design of High Power Backward Wave Oscillator (대 전력 후진파 발진기의 설계를 위한 마르크스 발생기의 제작 및 검증)

  • Kim, Won-Seop;Hwang, Nak-Hun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.8
    • /
    • pp.391-399
    • /
    • 1999
  • We have designed the backward wave oscillator, a power-pulsed generator oscillated at 20 GHz has higher frequency than current one. An absolute instability linear analysis was used for the purpose of designing the slow wave structure. A large diameter (D/$\lambda$=4.8) of the slow wave structure was adopted to prevent the breakdown brought about by the increase of power density. We have fabricated a marx generator, pulse forming line and diode. And the development of a compact pulsed power generator with short period and low amplitude is expected.

  • PDF

A Study on Efficient Simple Water Supply System in Rural Areas (농촌지역의 효율적인 간이 상수처리에 관한 연구)

  • 이홍근;백남원;백도현
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.3
    • /
    • pp.103-115
    • /
    • 1996
  • The purpose of this study was to establish acceptable criteria for the design of simple water treatment plant in rural areas. To develop efficient simple water treatment methods for rural areas, water quality in the study areas was investigated and rapid and slow filtrations in pilot-scale were tested under various conditions. The main results of this study are as follows. It was found that the water qualities of the study areas exceed the drinking water standards, which implies that some treatments are required in rural areas. Treatment efficiencies of both rapid sand and dual-media (sand and anthracite) filtration without pre-treatment such as flocculation and sedimentation are very low, which were turned out to be unadequate for the rural areas. Treatment efficiencies of both vertical and horizontal slow filtration without chlorination are very high for consumed $KMnO_4, NH_3-N, NO_3-N$, turbidity, and very low for coliform and bacteria. Treatment efficiencies of both vertical and horizontal slow filtration with chlorination are very high over the most pollutants. A slow filtration with chlorination is efficient for the rural areas. An adequate depth of sand layer is over 60 cm. A horizontal filtration is more economical than a vertical filtration. A horizontal filtration can be operated for a relatively long periods of time without sand washing or replacement because clogging is removed by simple back-washing.

  • PDF

Design and Implementation of Distributed Charge Signal Processing Software for Smart Slow and Quick Electric Vehicle Charge

  • Chang, Tae Uk;Ryu, Young Su;Song, Seul Ki;Kwon, Ki Won;Paik, Jong Ho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.3
    • /
    • pp.1674-1688
    • /
    • 2019
  • As environmental pollution and fossil fuel energy problems from fuel vehicle have occurred, the interest of electric vehicle(EV) has increased. EV industry and energy industry have grown dynamically in these days. It is expected that the next generation of primary transportation will be EV, and it is necessary to prepare EV infra and efficient energy management such as EV communication protocol, EV charge station, and smart grid. Those EV and energy industry fields are now on growth. Also, the study and development of them are now in progress. In this paper, distributed charge signal processing software for smart slow and quick EV charge is proposed and designed for dealing with EV charge demand. The software consists of smart slow and quick EV charge schedule engine and EV charge power distribution core. The software is designed to support two charge station types. One is normal EV charge station and the other is bus garage EV charge station. Both two types collect the data from EV charge stations, and then analyze the collected data. The software suggests optimized EV charge schedule and deliveries EV charge power distribution information to power switchboard system, and the designed software is implemented on embedded system. It is expected that the software provides efficient EV charge schedule.

Effects of Musculoskeletal Disease Prevention and Treatment Customized Exercise Program according to Various Music Tempo on the Pain, Posture, and Function of Auto Parts Manufacturing Workers

  • Kim, Ho;Shin, Wonseob
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.1
    • /
    • pp.48-54
    • /
    • 2021
  • Objective: The purpose of this study is to investigate the effect of exercise programs according to various music tempo on pain, posture, and function of automobile parts manufacturing workers. Design: Two-group pretest-posttest design. Methods: This study was an exercise program tailored to the prevention and treatment of musculoskeletal diseases were performed for a total of 4 weeks and 3 times a week for 60 minutes. The exercise program consisted of customized exercises according to the characteristics of the subject's musculoskeletal system. The subject provided music during the exercise program, and the group who applied the fast tempo music listened to the music of 120~140 bpm, and the group who applied the slow tempo music listened to the music of the low tempo of 60~80 bpm. Results: Significant differences were found in pain and physical function before and after the fast tempo music group and the slow tempo music group (p<0.01). However, there was a significant difference in posture characteristics only in the fast tempo music group (p<0.01). In terms of pain, physical function, and posture characteristics, the fast tempo music group showed significant improvement compared to the slow music tempo group (p<0.05). Conclusions: A customized exercise program using fast-tempo music and slow-tempo music to workers in the automobile parts manufacturing industry, significant differences in pain, physical function, and posture characteristics applied with fast-tempo music were found. In the future, applying an exercise program with a fast tempo is expected to help improve musculoskeletal disorders.

Influence of polymer-coated slow-release urea on total tract apparent digestibility, ruminal fermentation and performance of Nellore steers

  • Gardinal, R.;Calomeni, G.D.;Consolo, N.R.B.;Takiya, C.S.;Freitas, J.E. Jr;Gandra, J.R.;Vendramini, T.H.A.;Souza, H.N.;Renno, F.P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.1
    • /
    • pp.34-41
    • /
    • 2017
  • Objective: Two experiments were performed to evaluate the effects of coated slow-release urea on nutrient digestion, ruminal fermentation, nitrogen utilization, blood glucose and urea concentration (Exp 1), and average daily gain (ADG; Exp 2) of steers. Methods: Exp 1: Eight ruminally fistulated steers [$503{\pm}28.5kg$ body weight (BW)] were distributed into a d $4{\times}4$ Latin square design and assigned to treatments: control (CON), feed grade urea (U2), polymer-coated slow-release urea A (SRA2), and polymer-coated slow-release urea B (SRB2). Dietary urea sources were set at 20 g/kg DM. Exp 2: 84 steers ($350.5{\pm}26.5kg$ initial BW) were distributed to treatments: CON, FGU at 10 or 20 g/kg diet DM (U1 and U2, respectively), coated SRA2 at 10 or 20 g/kg diet DM (SRA1 and SRA2, respectively), and coated SRB at 10 or 20 g/kg diet DM (SRB1 and SRB2, respectively). Results: Exp 1: Urea treatments (U2+SRA2+SRB2) decreased (7.4%, p = 0.03) the DM intake and increased (11.4%, p<0.01) crude protein digestibility. Coated slow-release urea (SRA2+-SRB2) showed similar nutrient digestibility compwared to feed grade urea (FGU). However, steers fed SRB2 had higher (p = 0.02) DM digestibility compared to those fed SRA2. Urea sources did not affect ruminal fermentation when compared to CON. Although, coated slow-release urea showed lower (p = 0.01) concentration of $NH_3-N$ (-10.4%) and acetate to propionate ratio than U2. Coated slow-release urea showed lower (p = 0.02) urinary N and blood urea concentration compared to FGU. Exp 2: Urea sources decreased (p = 0.01) the ADG in relation to CON. Animals fed urea sources at 10 g/kg DM showed higher (12.33%, p = 0.01) ADG compared to those fed urea at 20 g/kg DM. Conclusion: Feeding urea decreased the nutrient intake without largely affected the nutrient digestibility. In addition, polymer-coated slow-release urea sources decreased ruminal ammonia concentration and increased ruminal propionate production. Urea at 20 g/kg DM, regardless of source, decreased ADG compared both to CON and diets with urea at 10 g/kg DM.

Multirate and Composite Control of Two-Time-Scale Stochastic Discrete-Time Systems (두개의 시간스케일 추계 이산시간 시스템의 다중표본화 복합제어기)

  • Park, Jong-Wook;Hong, Jae-Keun;Kim, Soo-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1225-1228
    • /
    • 1987
  • It is shown that the singularly perturbed continuous-time system is led to two different discrete versions according to slow or fast sampling rates. The design of stabilizing feedback control of singularly perturbed discrete-time stochastic system is decomposed into the design of slow and fast controllers, which is combined to form the composite control. Composite control law is derived for the case of both single rate measurement and multirate measurement.

  • PDF